NetApp FAS3210 System Configuration Data ONTAP 8.0.

2 7-Mode Software

NetApp FAS3210 Memory

Each FAS3210 system module comes standard with 4 GB of SDRAM with one DIMM bank being battery backed-up to provide nonvolatile NVMEM memory. The SDRAM subsystem on the FAS3210 combines system memory with nonvolatile memory (NVMEM) with 512 MB of the SDRAM on the FAS3210 providing nonvolatile memory for NVMEM functionality in Data ONTAP 8.0.2 7-Mode. A dual-controller FAS3210 HA has a total of 8 GB of SDRAM with two DIMM banks being battery backed-up to provide nonvolatile NVMEM memory. 1 GB of the SDRAM is dedicated to nonvolatile NVMEM memory in Data ONTAP 8.0.2 7-Mode.

Last updated: February 23, 2011

NetApp FAS3210 Disk Shelf Support

The following table lists the supported types of disk storage shelves and disk drives on the FAS3210. Caution: DiskShelf14mk2 AT must not be on the same loop as the Fibre Channel disk shelves. Note 1: All NetApp HA pair systems now require the use of MPHA cabling with just one exception. (HA pair FAS2040 configurations only have a single SAS port and as such only support single path connectivity to SAS storage shelves.) All NetApp single-controller systems are required to use dual-path connectivity with the exception of the FAS2040 using SAS storage shelves (due to the single SAS data port on the system). Note 2: You can add disk drives of the same type with different capacities within the same disk shelf. However, disk drives must be of the same type (FC, SAS, or SATA) within a single disk shelf. Standard power Notes supply/optional RPS AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required. Fibre Channel DiskShelf14mk2 FC shelves are available in any orderable configurations. Empty shelves: With AC power supplies: PN: X550 Without power supplies: PN: X551 Rack mount kit: PN: X5515A-R6 ESH2 module PN: X5511A Optical SFP PN: X6529 ESH4 module PN: X5512AR5 Optical SFP PN: X6539 FC SFP-to-SFP Patch Cable PN: X6530

Disk shelf

Disk drives

DiskShelf14mk2 FC

144-GB Fibre Channel (PN: X274B-R5/X275AR5/X278A-R5) 300-GB Fibre Channel (PN: X276A/X279A-R5) 450-GB Fibre Channel (PN: X291A-R5) 600-GB Fibre Channel (PN: X292A-R5)
q

Maximum of 14 per shelf

Note: X275, X278, X279, X291, and X292 are 15,000 RPM drives.

Note: When the disk shelf has ESH2s/ESH4s, the maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules. Note: Systems with more than two loops (112 disks) must also include a system cabinet. DiskShelf14mk4 FC 144-GB Fibre Channel (PN: X274B-R5/X275AR5/X278A-R5) 300-GB Fibre Channel (PN: X276A/X279A-R5) 450-GB Fibre Channel (PN: X291A-R5) 600-GB Fibre Channel (PN: X292A-R5)
q

AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required.

Fibre Channel DiskShelf14mk4 FC shelves are available in any orderable configurations. Empty shelves: With AC power supplies: PN: X553A With DC power supplies: PN: X553A-DC Rack mount kit: PN: X5515A-R6 ESH4 module PN: X5512AR5 Optical SFP PN: X6539 FC SFP-to-SFP Patch Cable PN: X6530 Note: The maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules. Note: Systems with more than two loops (112 disks) must also include a system cabinet.

Maximum of 14 per shelf

Note: X275, X278, X279, X291, and X292 are 15,000 RPM drives.

DS42431 With 24 drives: PN with 300-GB SAS drives: DS4243-1507-24S-QS-R5 PN with 450-GB SAS drives: DS4243-1511-24S-QS-R5 PN with 600-GB SAS drives: DS4243-1514-24S-QS-R5 PN with 500-GB SATA drives: DS4243-0712-24A-QS-R5 PN with 1-TB SATA drives: DS4243-0724-24A-QS-R5 PN with 2-TB SATA drives: DS4243-0748-24A-QS-R5 PN with 3-TB SATA drives: DS4243-0772-24A-QS-R5 With 12 drives: PN with 300-GB SAS drives: DS4243-1504-12S-QS-R5 PN with 450-GB SAS drives: DS4243-1505-12S-QS-R5 PN with 600-GB SAS drives: DS4243-1507-12S-QS-R5 PN with 500-GB SATA drives: DS4243-0706-12A-QS-R5 PN with 1-TB SATA drives: DS4243-0712-12A-QS-R5 PN with 2-TB SATA drives: DS4243-0724-12A-QS-R5 PN with 3-TB SATA drives: DS4243-0736-12A-QS-R5

300-GB SAS (PN: X410A-R5) 450-GB SAS (PN: X411A-R5) 600-GB SAS (PN: X412A-R5) 500-GB SATA (PN: X310A-R5) 1-TB SATA (PN: X302AR5) 2-TB SATA (PN: X306AR5) 3-TB SATA (PN: X308AR5)
q

AC power supply: 110/220V PN: X518A-R6

IOM3,SAS,3Gb,DS4243 PN: X5712A-R6 HDD CARR BLANK,EMI,DS4243 PN: X5051-R6 SAS,QSFP-QSFP,CU,100 OHM,0.5M PN: X6557-R6 SAS,QSFP-QSFP,CU,100 OHM,2M PN: X6558-R6 SAS,QSFP-QSFP,CU,100 OHM,5M PN: X6559-R6 SAS,QSFP-QSFP,CU,100 OHM,10M PN: X6590-R6 SAS,QSFP-QSFP,CU,100 OHM,20M PN: X6591-R6 ENETACP,RJ45,CAT6,CU,0.5M PN: X6560-R6 ENETACP,RJ45,CAT6,CU,2M PN: X6561-R6 ENETACP,RJ45,CAT6,CU,5M PN: X6562-R6 ENETACP,RJ45,CAT6,CU,10M PN: X6592-R6 ENETACP,RJ45,CAT6,CU,20M PN: X6593-R6 Note: A maximum of ten DS4243 disk shelves are supported per stack.

Maximum of 24 per shelf

DS22461 With 24 drives: PN with 450-GB SAS drives: DS2246-1011-24S-QS-R5 PN with 600-GB SAS drives: DS2246-1014-24S-QS-R5 With 12 drives: PN with 450-GB SAS drives: DS2246-1005-12S-QS-R5 PN with 600-GB SAS drives: DS2246-1007-12S-QS-R5

450-GB SAS (PN: X421A-R5) 600-GB SAS (PN: X422A-R5)


q

AC power supply: 110/220V PN: X519A-R6

IOM6,SAS,6-Gb,DS2246 PN: X5713A-R6 BLANK,DSK DRV FILLER,DS2246,R6 PN: X5054-R6 SAS,QSFP-QSFP,CU,100 OHM,0.5M PN: X6557-R6 SAS,QSFP-QSFP,CU,100 OHM,2M PN: X6558-R6 SAS,QSFP-QSFP,CU,100 OHM,5M PN: X6559-R6 SAS,QSFP-QSFP,CU,100 OHM,10M PN: X6590-R6 SAS,QSFP-QSFP,CU,100 OHM,20M PN: X6591-R6 ENETACP,RJ45,CAT6,CU,0.5M PN: X6560-R6 ENETACP,RJ45,CAT6,CU,2M PN: X6561-R6 ENETACP,RJ45,CAT6,CU,5M PN: X6562-R6 ENETACP,RJ45,CAT6,CU,10M PN: X6592-R6 ENETACP,RJ45,CAT6,CU,20M PN: X6593-R6> Note: A maximum of ten DS2246 disk shelves are supported per stack.

Maximum of 24 per shelf

DiskShelf14mk2 AT PN with 250-GB drives:DSX3.5TB-R5-C PN with 320-GB drives: DSX4.5TB-R5-C PN with 500-GB drives: DSX7.0TB-R5-C PN with 750-GB drives: DSX10.5TB-R5-C PN with 1-TB drives: DSX14TB-R5-C PN with 2-TB drives: DSX28TB-R5-C

250-GB SATA (PN: X262B-R5) 320-GB SATA (PN: X266B-R5) 500-GB SATA (PN: X267A-R5) 750-GB SATA (PN: X268A-R5) 1-TB SATA (PN: X269AR5) 2-TB SATA (PN: X294AR5)
q

AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required.

AT-FCX module PN: X5612A-R5 Rack mount kit: PN: X5515A-R6 Optical SFP PN: X6529 FC SFP-to-SFP Patch Cable PN: X6530 Note: The maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules.

Maximum of 14 per shelf

These disk shelves are not supported for MetroCluster configurations in the Data ONTAP 8.0.2 release.

Last updated: October 26, 2011

NetApp FAS3210 System Capacity

The following table lists the maximum system capacity and full system capacity supported by a FAS3210: NOTE: Full system capacity is the resulting system capacity of a storage system when populated with the maximum number of disk drives of a specific capacity point. This is the achievable system capacity of a storage system when using disk drives of a specific type and capacity point. Configuration rules common to a single FAS3210 or a FAS3210A in an HA environment

Size

32-bit Maximum raw aggregate/traditional volume size (in TB) 64-bit Minimum root FlexVol volume size (in GB) Default Using FC drives Maximum RAID4 Using SATA drives RAID Group Size (in number of disks) Default Using FC drives Maximum RAID-DP Using SATA drives Default Maximum Default Maximum

16 50 100 8 14 7 7 16 28 14 20

Configuration rules for a single dual-pathed FAS3210 and a multipathed FAS3210A2

Size

Maximum system capacity (in TB) Using 600-GB FC drives3 Full system capacity1 (in TiB) Using 3-TB SATA drives3 Using 600-GB SAS drives3

720 Up to 128 Up to 582 Up to 128

Maximum number of drives


1

240

Full system capacity varies depending on the type, size, and number of drives, where type can be FC drives only, SATA drives only, or a mixed storage solution. A mixed storage solution is configured with one loop dedicated to disk shelves that use FC drives and another loop dedicated to disk shelves that use SATA drives. The FAS3210A capacity is the sum of the capacity of both nodes. Do not exceed this sum. Disk drive capacity listed is the largest shipping disk drive supported on the date of the last update to this page.

2 3

Last updated: October 10, 2011

NetApp FAS3210 and FAS3210A Expansion Slot Assignments

The FAS3210 and FAS3210A have the following onboard ports: Two 10Base-T/100Base-TX/1000Base-T copper interfaces Two auto-sensing 4/2/1-Gb loop speed onboard optical Fibre Channel interfaces that can function as initiatormode interfaces or FCP target-mode interfaces. q Two auto-sensing 6/3-Gb loop speed onboard optical SAS interfaces. q A 10/100 Mb Ethernet port for Management, also known as the wrench port. q A 10/100 Mb Ethernet interconnect port for Private management, also known as the padlocked wrench port.
q q

Note: The following table lists the recommended top to bottom load order for adapters into storage systems. The following table lists the types of expansion adapters, part numbers, maximum number of each type of expansion adapter that you can install in the storage system, and slots in which you can install the adapters. Maximum number of adapters

Expansion slot 1 2

Expansion adapter MetroCluster adapter Dual-port 8-Gb VI-MetroCluster

PN

X1927A-R6

E1

High Performance Network and Block Access adapters Dual-port 10GbE SFP+ with copper or fiber Dual-port 8-Gb VI for SnapMirror over Fibre Channel Dual-port 10-GbE Unified Target Adapter with fiber (supports FCoE/10GbE/iSCSI/NFS/CIFS) Dual-port 10-GbE Unified Target Adapter with copper (supports FCoE/10GbE/iSCSI/NFS/CIFS) Dual-port 8/4/2-Gb FCP target-mode interface X1107A-R64, 6 X1142A-R65 X1139A-R6 2 E1 E2 2 1 E1 E2 E1

X1140A-R6 X1131A-R6

Performance Acceleration Module I (PAM I) and Flash Cache modules X1937A-R52 Flash Cache 256 GB X1970A-R522 Disk Shelf Storage adapters 1 E1 E2

Quad-port 4/2/1-Gb Fibre Channel optical Quad-port 3/6-Gb SAS QSFP Dual-port 4/2/1-Gb Fibre Channel optical Standard Performance Block Access adapters Dual-port 4-Gb FCP target-mode interface Quad-port 4/2/1-Gb FCP target-mode interface Standard Performance Network adapters

X2054A-R61 X2065A-R63, 4 X2055A-R6 2 E1 E2

X1128A-R6 2 X1130A-R6 E1 E2

X1049A-R6 Quad-port GbE with copper X1049B-R6 Dual-port optical GbE Tape Storage adapters Quad-port 4/2/1-Gb Fibre Channel optical Dual-port SCSI-LVD/SE Dual-port 4/2/1-Gb Fibre Channel optical
1 2 3 4 5

E1

E2

X1038A-R6

X2054A-R61 X2028A-R6 X2053A-R6 2 E1 E2

See the documentation that comes with this adapter or with the storage controller for rules of usage. Flash Cache was previously known as Performance Acceleration Module II (PAM II). Total Flash Cache may not exceed 256 GB. This adapter cannot be used in MetroCluster configurations. This adapter is supported in Data ONTAP 8.0 RC3 and later. Source and destination systems do not need to have the same SnapMirror over Fibre Channel (SMoFC) SMoFC card type. While only the X1142 is supported on this platform, if the source or destination controller is a different platform supporting X1124 or X1142 SMoFC cards those may be used for connecting to the X1142 on this platform. This adapter requires the SFP+ PN X6563-R6 or a twinax cable for connectivity.

Last updated: August 30, 2011