Powersafe HomeUPS Backup Time Chart*

Load Watts Load 18AH 25AH 40AH 65AH watts Load 65AH 80AH 100AH 120AH 150AH 190AH watts Load 65AH 80AH 100AH 120AH 150AH 190AH 100 Half 1h20m 2h15m 4h 7h 150 4h 5h 7h 9h 11h 15h 150 9h 13h 17h 20h 27h 35h 200 Full 30m 50min 1h30m 3h 300 1h30m 2h15m 3h 4h 5h 7h 300 4h 5h 7h 9h 11h 15h 450 55min 1h20m 1h45m 2h 3h 4h 450 2h 3h 4h 5h30 8h 10h 600 38min 55min 1h12min 1h30m 2h15m 3h 600 1h30m 2h15m 3h 4h 5h 7h 720 Full 30min 42min 57min 1h12m 1h45m 2h20m 720 Half 1h12m 1h45m 2h20m 3h 4h15m 5h30m 900 55min 1h20m 1h45m 2h 3h 4h 1200 38min 55min 1h12min 1h30m 2h15m 3h 1440 Full 30min 42min 55min 1h12m 1h45m 2h20m

PS-400i
Battery: 12V x 1 DC Bus: 12V Charger: 3 Amp Load

PS-1200i
Battery: 12V x 1 DC Bus: 12V Charger: 10 Amp Load

PS-2400i
Battery: 12V x 2 DC Bus: 24V Charger: 10 Amp

* Notes (Very Important):1. All HomeUPS are having 10 Amps Charger, except 400i which is having 3A charger. 2. We recomand from 65 to 200AH battery with 1200i & 2400i, 18 to 65AH with 400i. 3. The backup time is calculated with thick palate Inverter grade fully charged battery. 4. Automotive and Local Make batteries are not designed for such applications and may not give you propper backup. 5. Back-up time is purely battery dependent & may vary with type & condition of batterries, battery maintenance, change 6. The load consideration is a typical load & can vary with brand, type & capacity of the equipements.

Tube Light Tube Light (Elec. Choke) Fan CFL PL Tubes Computer System TV 25" to 29"

75W 40W 75W Calc Double (0.55pf) Calc Double (0.55pf) 250W 250W onwards

7. Following Equipment (and similar other euipments) not supported on above models. Air Conditioner, Room Heater, Water Heater, Boiler, Motor, Grill Oven, Microwave Oven, Electric Iron, Refrigerators