Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

80 PLUS Verification and Testing Report

TYPICAL EFFICIENCY (50% Load): AVERAGE EFFICIENCY : 80 PLUS COMPLIANT:

85.71% 83.87% YES

Voltage (V)

50 0 -50 0 -100 0.003 0.006 0.009 0.012 0.015

0 -5 -10 -15 Time (s) Voltage Current

Rated Specifications
Input Voltage Input Current Input Frequency Rated Output Power

Value
100-240 15 50-60 1200

Units
Volts Amps Hz Watts

-150 -200

Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.

Input AC Current Waveform (ITHD = 8.7%, 50% Load)

IRMS A 2.61 6.17 12.63

PF 0.95 0.99 0.99

ITHD (%) 17.7% 8.7% 5.4%

Load (%) 20% 50% 100%

Fraction Input of Load Watts Light Typical Full 285 699 1446

DC Terminal Voltage (V)/ DC Load Current (A) 3.3V 5V* -12V 12V (cumulative of 12V1, 12V2, etc.) 12/0.1 3.4/4.4 5.1/4.4 12.2/16.4 12.1/0.4 3.2/10.9 5/10.9 12/40.9 12.3/0.8 3/21.7 4.7/21.9 11.7/81.8

5VSB 5.1/1.2 5/2.9 4.7/5.8

Output Watts 244 599 1161

Efficiency % 85.56% 85.71% 80.33%

Input and Output Power 1600 1400 80% 1200 Power (Watts) 1000 800 600 400 200 0 20% Output Watts 40% Input Watts Efficiency (%) 70% 60% 50% 90%

Efficiency of the Power Supply

Efficiency % 30% 50% Loading (% of Rated Output Power) 100% 0% 25% 50% 75% 100% Loading (% of Rated Output Power) 125%

These tests were conducted as a part of the 80 PLUS program. 80 PLUS is a computer buy-down program to promote high-efficiency power supplies (greater than 80% efficiency in the active mode) in desktop computers and desktop-derived servers.

Tested by Electric Power Research Institute, Knoxville, TN.

Current (A)

Ecos ID # Manufacturer Model Number Serial Number Year Type Test Date

464.1 CHIEFTEC CFT-1200-DF NA 2008 ATX12V 2/13/2008

Input Current and Voltage Waveforms 200 150 100 5 15 10