Preliminary Estimation for reinforcement for Building Works

Sl.No.

Member

Qty. in Kg/m3

Size of steel required


10mm or 12mm For footing size upto 2.0m use 10mm and above 2.0m use 12 mm. 12, 16mm 85% Stirrups 8mm 15% 8mm Dia 85%, Stirrups 6mm 15% 16,20, 25 mm 90% Ties 8 mm dia 10% 12, 16mm Dia 85% Stirrups 8mm 15% 8mm Dia 75% Distributor 6 mm 25% 10mm dia 80% Distributor 8mm 20% 12 or 16mm dia 85% Distributor 8mm dia 15% 8mm dia 70% Distributor 6mm 30% 8mm dia 100%

1 2 3 4 5 6 7 8 9 (a) (b) (c) 10

Column footings Grade beams Plinth beams Columns Lintel Beam Sunshades Canopy slab up to 2.0 m span Staircase waist slab Roof slab One way Two way Square slab 4 to 6m size Main beams above 6m

75 100 125 225 125 60 125 150

80 100 150 250

10 - 12mm dia 100% 20, 16, 12 mm 80% to 85%, Stirrups 8mm 15 to 20%

Note : All rods mentioned above are RTS rods only.

Reinforcement Based on % of Steel

Reinforcement %( of c.s. of concrete) 0.5 % 0.8% 1.0 % 1.20% 1.50% 2.0 % 2.5 % 3.0 % 3.5 % 4.0 % 4.5 % 5.0 %

Quantity of Steel in Kg / m3 39 63 78 94 117 158 196 235 274 313 352 392

Note:
20 % should be added in these values to take in to account laps, bends, wastage etc., while computing Kg / m3.