A) DURING STRUCTURE WORKS During casting of the sunken portions, concrete to be properly compacted so as to avoid any honeycombing and voids in RCC slab.
The specified sunken depth mentioned in the relevant drawings to be maintained during casting so as to avoid any cutting or chiseling of RCC slab during laying of plumbing pipes.
If any honey combing in RCC is noticed, it is to be treated properly with water proofing chemicals/ injection grouting.
One number 50mm dia, 30-35 cm long medium grade GI/ UPVC pipe spout on downstream side towards shaft with Geo fabric filter on inside mouth to be provided in each sunken portion.
Unitech, Gurgaon
Filling of sunken by sand and laying PCC over the same at the earliest after water proofing treatments.