Technical Data - O240708CBSJ

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Format No.

OWCPL/QS/MTC/S

Technical Data Sheet


Village-Saidpur, Tehsil-Kharkhoda, DistSonipat, 131402, Haryana, India Item Name Description Item Code Spec. Ref. Customer Sr. No. 1

T.D.S. No. Issue No & Date Rev. No & Date Ref. CR No. Cust. Enq./PO No.

OWCPL/TDS/S 07/06/12 00/00 OWC/CR/.../12-13 dtd ......

PTFE Insulated Multicore cable, AWG 24/7/32, Silver plated copper, Type ET+ (300 V AC), 4 Pair twisted (White/Brown, White/Green, White/Blue, White/Orange), PTFE Cushion, AWG 3801 Silver Plated Copper Braid, Black PTFE Jacket PTFE Insulated Multicore cable, AWG 24/7/32, Silver plated copper, Type ET+ (300 V AC), 4 Pair twisted (White/Brown, White/Green, White/Blue, White/Orange), PTFE Cushion, AWG 3801 Silver Plated Copper Braid, Black PTFE Jacket O240708CBSJ GTP/ Customer Specs. No.

Description Conductor

Parameter Material Diameter of Strand No of strands Conductor Diameter Cross-Sectional Area Conductor Resistance (max) Elongation Material Insulation Type Thickness Dia of core Lay of Twist (For Pair) Twisted OD of Pair Lay of Twist (For all the Twisted Pair) OD of all the Twisted Pair OD Over PTFE Cushion Material Number of Carriers OD of Strand Number of Strands Pricks/Inches OD Over Copper Armour/Braid Shield

Unit mm (nom) nos mm (nom) Sqmm (max) /km at 20deg.oC % (min) PTFE, Tape Wrapped & Sintered Type/V AC mm (nom) mm (nom) mm (Approx.) mm (nom) mm (Approx.) mm (nom) mm (nom) mm (nom) Unit mm (nom) -

Insulation

Twisting

4 5

PTFE Cushion Braiding

Specified Value Silver Plated Copper 0.203 7 0.61 0.23 79.1 15 (before stranding) Core complies with the requirements of U.S. Military Specification MIL-W16878/21 ET+/300 0.18 0.99 16.85 1.69 40.82 4.08 4.24 Silver Plated Copper 16.0
0.10

9.0 12.0 4.64

Outer Sheath

Material Thickness Outer Diamteter


Gauge/Size Conductor Diameter Number of Strands Strand Diameter Core Insulation Core Diameter at Final Stage Color Sequence & Lay Spark Test Dielectric Test

mm (nom) mm (Approx)
mm (nom) mm (nom) Unit mm (nom) mm (nom) mm (nom) 1 Second at 2.5 KV 1 Minute at 1.5 KV 1 Meter from each end of Wires /km at 20deg.oC 1 Second at 1/2 KV 1 Second at 500 V /km at 20deg.oC

Polyurethane 0.25 5.14


OK OK OK OK OK OK OK Passed - OK Passed - OK Passed - OK Passed - OK Passed - OK Passed - OK Passed - OK Page No. 1 of 1

Physical Test

Electrical Test (Before Twisting on Cores, 100% Length in Water BDV on Cores Tank)

DC Resistance at 20 C Electrical Test (Test on Spark Test, Core to Core Finished Cable) Spark Test, Jacket DC Resistance at 20C, Shield

Prepared & Checked by :

Checked & Approved By Manoj Agarwal

You might also like