Professional Documents
Culture Documents
Datasheet UK PowerMan
Datasheet UK PowerMan
PowerMan-1 series: the high power Multi/MultiPlus bypass The maximum feedthrough current of a Multi/MultiPlus is 16 A. When Multis are paralleled the maximum allowable feedthrough current increases accordingly, however to a maximum of 32 A. When the required feedthrough current exceeds 16 A with 1 Multi, or 32 A with 2 or more Multis a PowerMan-1 Multi bypass switch is needed. The PowerMan-1 has a current limit panel (similar to the Multi Control Panel) to set the maximum AC current. The PowerMan-1 is intended for a single AC source. 2 Models: . PowerMan 230/40-1: input rated at 40 A and with 0 to 40 A current limit panel (300x380x210 mm, 11kg) . PowerMan 230/80-1: input rated at 80 A and with 0 to 80 A current limit panel (500x500x210 mm, 22kg)
Victron Energy B.V. / De Paal 35 / 1351 JG ALMERE / The Netherlands Phone: (+31) (0)36 535 97 00 / Fax: (+31) (0)36 535 97 40 / www.victronenergy.com / e-mail: sales@victronenergy.com
PowerMan-2 series The PowerMan-2 is a transfer switch and a Multi/MultiPlus bypass in one. It comes with 2 current limit panels to independently set the maximum AC current from both AC sources. The internal current limit panel is used to set the maximum generator current, and the external PowerMan Control Panel can be used to set the current of the alternative source, e.g. shore power. 2 Models: . PowerMan 230/40-2: shore 16 A and generator 40 A and with an internal 0 to 40 A current limit panel
(h x w x d: 600x380x210 mm, 22 kg)
. PowerMan 230/80-2: shore 16 A and generator 80 A and with an internal 0 to 80 A current limit panel
The second external current limit panel can be specified for 0 to 16 A, or 0 to 32 A. This PowerMan Control Panel is very similar to, but not interchangeable with the Multi Control Panel.
Filax: the ultra fast transfer switch The Filax has been designed to switch sensitive loads, such as computers or modern entertainment equipment from one AC source to another. The priority source typically is the mains, a generator or shore power. The alternate source typically is an inverter. With its switching time of less than 20 ms sensitive loads will continue to operate without disruption. The Filax is not intended to supply high power household equipment like washing machines or electric motors. Because it is a fast switch, the Filax will transfer the load to the alternate source even in case of short voltage dips (4 to 12 ms) or unstable frequency. Operating the Filax with a generator can therefore result in transfer of the load to the alternate source whenever a sudden load variation occurs. The feedthrough switch in the Multi/MultiPlus is equally fast. We therefore recommend to use a Multi or MultiPlus instead of an inverter and a Filax whenever the load exceeds 700 W / 800 VA. The PowerMan transfer switch is not fast. In case of the PowerMan uninterrupted AC supply is achieved thanks to one or more Multi/MultiPlus units which will carry the load through an AC break.
Victron Energy B.V. / De Paal 35 / 1351 JG ALMERE / The Netherlands Phone: (+31) (0)36 535 97 00 / Fax: (+31) (0)36 535 97 40 / www.victronenergy.com / e-mail: sales@victronenergy.com