Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

Monitoring Criteria Alarm Class Description 7706 For Site Down 7767 For cell/Sector down 4000-4016 BSC

power alarms 7604; VSWR issues 7745; Channel Failure rate 7789; No GPRS 7710; Lock/Unlock Details

Commands ZEEI:BCF="BCF NO"; ZEOL:"BCF NO"; ZEOH::BCF="BCF NO"; ZEOH:"YYYY-MM-DD,"HH-MM-SS":BCF="BCF NO"; ZAHO; ZAHO:ET,"PCM NO"; ZYMO:ET,"PCM NO"; ZUSC:ET,"PCM NO":BL; ZUSC:ET,"PCM NO":WO; ZAHP:ET,"PCM NO"; ZDTI:::PCM="PCM NO"; ZDTC:"NAME":WO; ZEFR:"BCF NO"; ZEFR:"BCF NO":OMU; ZEQS:BTS="BTS NO":L; ZEQS:BTS="BTS NO":U; ZERS:BTS="BTS NO",TRX="TRX NO":L; ZERS:BTS="BTS NO",TRX="TRX NO":U; ZEWV:"BCF NO":BU; ZQNS; ZEOR:"BCF NO":"ALARM NO";

BSC Commands
ZEOL::NR=7706; ZEOL::NR=7767; ZEOL::NR=7606; ZEOL::NR=8060; ZEOL::NR=8066; 7604; 7745; 7789; 7710;

Description Status of site including Type of BTS, status of OMU, BTS,TRX, FREQ, PCM NO& TRAFFIC Shows the active alarms of site including internal and external both with time Displays alarm history since start of the day Displays alarm history since input date and time Displays alarms of BSC Displays alarm on ET Displays slips or error on ET To reset ET slips Displays history of ET To change state of ET devices in WO mode only if it is in UAD State To reset BCF For OMU reset (Only for Ultra BTS) Sector block/deblock TRX block deblock For software back up/reset Displays the logged users To delete a false alarm Site down in a BSC Cell/Sector down TRX down No incoming Radio signal AIS received VSWR issues Channel Failure rate No GPRS Lock/Unlock Details

Commands

Commands rlcrp:cell="Moname"; allip:alcat=ext; allip:acl=all; allip:acl=a1; allip:acl=a2; dtstp:dip='dipname'; dtstp:dip=all,state=abl; dtqup:dip=dip name; dtqsr:dip=dip name,unacc,degr,sf; rxtcp:moty=rxotg,cell=moname; rxcdp:mo=rxotg-"TG"; rxbli:mo=rxotg-"TG",subord,force; rxese:mo=rxotg-"TG",subord; rxesi:mo=rxotg-"TG",subord; rxble:mo=rxotg-"TG",subord; rlstp:cell=all,state=halted; rxmfp:moty=rxocf,faulty;

Description Site status Displays external alarms Displays all alarms Displays class1 alarms Displays class2 alarms Digital path status All dip down of BSC displays errors on dip Error reset To find TG of a site Site status Site Reset/ Full loading To find halted sites of a BSc Displays CF faults of a BSC