Professional Documents
Culture Documents
Vol02 Tab01
Vol02 Tab01
1.1
Safety Switches
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . . . . . . . . . . . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . . . . . . . . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . . . . . . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch . . . . . . . . . . . . . . Quick Connect Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . . . . . . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch. . . . . . . . . . . . . . . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedFixed Depth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1.2
1.3
Learn Online
www.eaton.com
V2-T1-1
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-2 Description Type Fuse type Fusible
Switching Devices
Safety Switches
Contents
Description
Product Overview Standards and Certifications. . . . . . . . . . . . . . . . . Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . Options and Accessories . . . . . . . . . . . . . . . . . . . ModificationsFlex Center . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-5 V2-T1-6 V2-T1-14 V2-T1-15 V2-T1-17 V2-T1-21 V2-T1-21 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Product Overview
Product Selection Guide
Safety Switch
Non-fusible
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1
General-Duty H
Heavy-Duty H L
Rotary Switches
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
30 30600
30600 301200
30200
301200 2, 3 and 4
30200 6
301200 2 and 3
16125 0
Non-fusible Enclosure types NEMA 1 Fusible Non-fusible NEMA 3R Fusible Non-fusible NEMA 12 Fusible Non-fusible NEMA 4 painted steel Fusible Non-fusible NEMA 4X stainless steel Fusible Non-fusible NEMA 4X non-metallic Fusible Non-fusible NEMA 7/9 Fusible Non-fusible
2 and 3
2, 3 and 4
2, 3, 4 and 6
3 and 4
Yes, up to 1200A Yes Yes, up to 1200A Yes Yes, up to 1200A 1 Yes, up to 1200A 1 Yes, 400800A Yes, 400800A Yes, up to 1200A Yes, up to 1200A Yes, up to 200A Yes, up to 200A Yes, up to 200A Yes, up to 200A 2
Notes 1 NEMA Type 12 enclosures (30800A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain screw is removed. 2 Class J fuse clips provided.
www.eaton.com
V2-T1-3
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-4 Description Type Fuse type Fusible Non-fusible Fuse class Fusible
Switching Devices
Safety Switches
EnviroLine Safety
Receptacle
Non-Metallic
Cartridge H
Cartridge H L
Cartridge H
Cartridge H
30400
30600 800
30100
30200
Non-fusible Number of poles Fusible Non-fusible Enclosure types NEMA 1 Fusible Non-fusible NEMA 3R Fusible Non-fusible NEMA 12 Fusible Non-fusible NEMA 4 painted steel Fusible Non-fusible NEMA 4X stainless steel Fusible Non-fusible NEMA 4X non-metallic Fusible Non-fusible
30400
30800
60
30200
2 and 3 3
3 3
3 3
3 3
Yes Yes
Yes Yes
Notes 1 800A upper window switches are not UL listed. 2 Lower window switches are available through 600A. 3 30100A switches provided with full view window. 4 NEMA Type 12 enclosures (30800A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain screw is removed.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Product Overview
Used to open or close a circuit Non-fusible safety switches provide a means to manually connect or disconnect the load from the source Fusible safety switches provide a means to manually open and close a circuit and overcurrent protection by means of installed fuses Also commonly referred to as a disconnect switch or disconnect Available from 301200A
UL 98 UL 50 NEMA KS-1
www.eaton.com
V2-T1-5
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-6
Switching Devices
Safety Switches
Cross-Reference
General-Duty
Ampere Rating Catalog Number Eaton General ElectricT SiemensT Square DT
General-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Plug Fuse, Single-Pole, Two-Wire, 120 Vac, NEMA 1 30 DP111NGB TPF130 LF111N D211N
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 D211N 100 200 D221N D222N D223N D224N D225N D226N 400 600 DG221NRB DG222NRB DG223NRB DG224NRK DG225NRK DG226NRK TG3221R TG3222R TG3223R TG3224R TG3225R TG3226R GF221NR GF222NR GF223NR GF224NR GF225NR GF226NR D221NRB D222NRB D223NRB D224NRB D225NR D226NR
Plug Fuse, Two-Pole, Three-Wire, 240 Vac, NEMA 1 30 DP221NGB TPF230 LF211N
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DG221NGB DG222NGB DG223NGB DG224NGK DG225NGK DG226NGK TG3221 TG3222 TG3223 TG3224 TG3225 TG3226 GF221N GF222N GF223N GF224N GF225N GF226N
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 100 200 DG321NRB DG322NRB DG323NRB DG324NRK DG325FRK DG326FRK TG4321R TG4322R TG4323R TG4324R TG3325R TG3326R GF321NR GF322NR GF323NR GF324NR GF325NR GF326NR D321NRB D322NRB D323NRB D324NRB D325NR D326NR
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DG321NGB DG322NGB DG323NGB DG324NGK DG325FGK DG326FGK TG4321 TG4322 TG4323 TG4324 TG3325 TG3326 GF321N GF322N GF323N GF324N GF325N GF326N D321N D322N D323N D324N D325N D326N
400 600
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 3R 30 60 100 200 DG321NRB DG322NRB DG323NRB DG324NRK DG325NRK DG326NRK TG4321R TG4322R TG4323R TG4324R TG3325R 1 TG3326R 1 GF321NR GF322NR GF323NR GF324NR GF325NR GF326NR D321NRB D322NRB D323NRB D324NRB D325NR D326NR
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DG321NGB DG322NGB DG323NGB DG324NGK DG325NGK DG326NGK TG4321 TG4322 TG4323 TG4324 TG4325 TG4326 GF321N GF322N GF323N GF324N GF325N GF326N D321N D322N D323N D324N D325N D326N
400 600
Non-Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 3R 30 60 100 200 DG221URB DG222URB DG223URB DG324URK TGN3321R TGN3322R TGN3323R TGN3324R GNF321R GNF322R GNF323R GNF324R DU221RB DU222RB QO2000NRB DU324RB
Non-Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DG221UGB DG222UGB DG223UGB DG324UGK DG325UGK DG326UGK TGN3321 TGN3322 TGN3323 TGN3324 TGN3325 TGN3326 N/A N/A N/A N/A N/A N/A N/A QO260NATS QO2000NS DU324 DU325 DU326
Non-Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 DG321URB DG322URB DG323URB DG324URK DG325URK DG326URK TGN3321R TGN3322R TGN3323R TGN3324R N/A N/A GNF321R GNF322R GNF323R GNF324R N/A N/A DU321RB DU322RB DU323RB DU324RB N/A N/A
Non-Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DG321UGB DG322UGB DG323UGB DG324UGK DG325UGK DG326UGK TGN3321 TGN3322 TGN3323 TGN3324 TGN3325 TGN3326 GNF321 GNF322 GNF323 GNF324 GNF325 GNF326 DU321 DU322 DU323 DU324 DU325 DU326
Notes 1 Separate neutral kit required. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
Square D
Heavy-Duty
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens
Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH221FGK DH222NGK DH223NGK DH224NGK DH225FGK DH226FGK DH227FGK DH328FGK TH3221 TH3222 TH3223 TH3224 TH3225 TH3226 TC72267 TC72268 N/A N/A N/A N/A N/A N/A N/A N/A H221N H222N H223N H224N H225 H226 H227 H228
Non-Fusible, Three-Pole, Three-Wire, 240 Volt/600 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH361UGK DH362UGK DH363UGK DH364UGK DH365UGK DH366UGK DH367UGK DH368UGK THN3361 THN3362 THN3363 THN3364 THN3365 THN3366 TC36367 TC36368 HNF361 HNF362 HNF363 HNF364 HNF365 HNF366 HNF367 HNF368 HU361 HU362 HU363 HU364 HU365 HU366 HU367 HU368
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH221NGK DH222NGK DH223NGK DH224NGK DH225NGK DH226NGK DH227NGK DH328NGK TH3221 TH3222 TH3223 TH3224 TH3225 TH3226 TC72267 1 TC72268 1 HF221N HF222N HF223N HF224N HF225N HF226N HF227N HF228N H221N H222N H223N H224N H225N H226N H227N H228N
Fusible, Three-Pole, Two-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH221NRK DH222NRK DH223NRK DH224NRK DH225FRK DH226FRK DH227NRK DH328FRK TH3221R TH3222R TH3223R TH3224R TH3225R TH3226R TC72267R TC72268R N/A N/A N/A N/A N/A N/A N/A N/A H221NRB H222NRB H223NRB H224NRB H225R H226R H227R H228R
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH321FGK DH322FGK DH323FGK DH324FGK DH325FGK DH326FGK DH327FGK DH328FGK TH4321 TH4322 TH4323 TH4324 TH3325 TH3326 TC72367 TC72368 N/A N/A N/A N/A N/A N/A N/A N/A H321N H322N H323N H324N H325 H326 H327 H328
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH221NRK DH222NRK DH223NRK DH224NRK DH225NRK DH226NRK DH227NRK DH328NRK TH3221R TH3222R TH3223R TH3224R TH3225R TH3226R TC72267R 1 TC72268R 1 HF221NR HF222NR HF223NR HF224NR HF225NR HF226NR HF227NR HF228NR H221NRB H222NRB H223NRB H224NRB H225NR H226NR H227NR H228NR
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH321NGK DH322NGK DH323NGK DH324NGK DH325NGK DH326NGK DH327NGK DH328NGK TH4321 TH4322 TH4323 TH4324 TH4325 TH4326 TC72367 1 TC72368 1 HF321N HF322N HF323N HF324N HF325N HF326N HF327N HF328N H321N H322N H323N H324N H325N H326N H327N H328N
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH321FRK DH322FRK DH323FRK DH324FRK DH325FRK DH326FRK DH327FRK DH328FRK TH4321R TH4322R TH4323R TH4324R TH3325R TH3326R TC72367R TC72368R N/A N/A N/A N/A N/A N/A N/A N/A H321NRB H322NRB H323NRB H324NRB H325NR H326NR H327NR H328NR
Fusible, Four-Pole, Four-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DH421FGK DH422FGK DH423FGK DH424FGK DH425FGK DH426FGK N/A N/A N/A N/A N/A N/A F421 F422 F423 F424 F425 F426 H461
2
Notes 1 Separate neutral kit required. 2 600V switch. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
www.eaton.com
V2-T1-7
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Ampere Rating Catalog Number Eaton
Switching Devices
Safety Switches
Heavy-Duty, continued
General Electric Siemens Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH321NRK DH322NRK DH323NRK DH324NRK DH325NRK DH326NRK DH327NRK DH328NRK TH4321R TH4322R TH4323R TH4324R TH3325R 1 TH3326R 1 TC72367R 1 TC72368R 1 HF321NR HF322NR HF323NR HF324NR HF325NR HF326NR HF327NR HF328NR H321NRB H322NRB H323NRB H324NRB H325R H326R H327R H328R
Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH221NDK DH222NDK DH223NDK DH224NDK DH225FDK DH226FDK DH227FDK N/A TH2221J TH2222J TH3223J TH3224J TH3225J TH3226J N/A N/A HF221J HF222J HF223J HF224J HF325J HF326J HF327J N/A H221AWK H222AWK H223AWK H224AWK H225AWK H226AWK H227AWK H228AWK
Non-Fusible, Three-Pole, Three-Wire, 240 Volt/600 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH361URK DH362URK DH363URK DH364URK DH365URK DH366URK DH367URK DH368URK THN3361R THN3362R THN3363R THN3364R THN3365R THN3366R N/A N/A HNF361R HNF362R HNF363R HNF364R HNF365R HNF366R HNF367R HNF368R HU361RB HU362RB HU363RB HU364RB HU365R HU366R HU367R HU368R
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH221NDK DH222NDK DH223NDK DH224NDK DH225NDK DH226NDK DH227NDK N/A TH3221J TH3222J TH3223J TH3224J TH3225J TH3226J N/A N/A HF221J 1 HF222J
1
Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 4/4X 30 60 100 200 400 600 DH221NWK DH222NWK DH223NWK DH224NWK DH225FWK DH226FWK TH2221SS TH2222SS TH3223SS TH3224SS TH3225SS TH3226SS HF221S HF222S HF223S HF224S HF325S HF326S H221DS H222DS H223DS H224DS H225DS H226DS
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 12 30 60 100 200 400 600 800 H221DS 1 H222DS
1
Fusible, Two-Pole, Three-Wire, 240 Vac, NEMA 4/4X 30 60 100 200 400 600 800 DH221NWK DH222NWK DH223NWK DH224NWK DH225NWK DH226NWK DH227NWK TH3221SS TH3222SS TH3223SS TH3224SS TH3225SS TH3226SS N/A HF321S 1 HF322S
1
1200
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 12 30 60 100 200 400 600 DH321NDK DH322NDK DH323NDK DH324NDK DH325NDK DH326NDK N/A N/A TH4321J TH4322J TH4323J TH4324J TH4325J TH4326J N/A N/A HF321J 1 HF322J HF323J
1 1
H223DS 1 H224DS
1
HF326S 1 HF327S 1
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 4/4X 30 60 100 200 400 600 800 DH321FWK DH322FWK DH323NWK DH324NWK DH325FWK DH326FWK DH327FWK TH3321SS TH3322SS TH4323SS TH4324SS TH4325SS TH4326SS N/A HF321S HF322S HF323S HF324S HF325S HF326S HF327S H321DS H322DS H323DS H324DS H325DS H326DS N/A
800 1200
Fusible, Four-Pole, Four-Wire, 240 Vac, NEMA 12 30 60 100 200 DH421FDK DH422FDK DH423FDK DH424FDK N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Fusible, Three-Pole, Four-Wire, 240 Vac, NEMA 4/4X 30 60 100 200 400 600 DH321NWK DH322NWK DH323NWK DH324NWK DH325NWK DH326NWK TH4321SS TH4322SS TH4323SS TH4324SS TH4325SS TH4326SS HF321S 1 HF322S 1 HF323S
1
Notes 1 Separate neutral kit required. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
HF324S 1 HF325S
1
HF326S 1
V2-T1-8
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens
Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH261FGK DH262FGK DH263FGK DH264FGK DH265FGK DH266FGK DH267FGK N/A TH2261DC TH2262DC TH2263DC N/A N/A N/A N/A N/A HF261 HF262 HF263 N/A HF265 HF266 N/A N/A H361 H362 H363 H364 H265 H266 H267 H268
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 DH461UGK DH462UGK DH463UGK DH464UGK DH465UGK DH466UGK THN6661 THN6662 THN6663 THN6664 N/A N/A N/A N/A N/A N/A N/A N/A HU461 HU462 HU463 HU464 HU465 HU466
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 3R 30 60 DH361FRK DH362FRK DH363FRK DH364FRK DH365FRK DH366FRK DH367FRK DH368FRK TH2261RDC TH2262RDC TH2263RDC N/A N/A N/A N/A N/A HF261R HF262R HF263R N/A N/A HF265R HF266R N/A H361RB H362RB H363RB H364RB H265R H266R H267R H268R
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH361FGK DH362FGK DH363FGK DH364FGK DH365FGK DH366FGK DH367FGK DH368FGK TH3361 TH3362 TH3363 TH3364 TH3365 TH3366 TC72367 TC72368 HF361 HF362 HF363 HF364 HF365 HF366 HF367 HF368 H361 H362 H363 H364 H365 H366 H367 H368
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 3R 30 60 DH361FRK DH362FRK DH363FRK DH364FRK DH365FRK DH366FRK DH367FRK DH368FRK TH3361R TH3362R TH3363R TH3364R TH3365R TH3366R TC72367R TC72368R HF361R HF362R HF363R HF364R HF365R HF366R HF367R HF368R H361RB H362RB H363RB H364RB H365R H366R H367R H368R
Fusible, Three-Pole, Four-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH361NGK DH362NGK DH363NGK DH364NGK DH365NGK DH366NGK DH367NGK DH368NGK TH3361 1 TH3362 1 TH3363 1 TH3364 1 TH3365 1 TH3366 1 TC72367 1 TC72368 1 HF361N HF362N HF363N HF364N HF365N HF366N HF367N HF368 1 H361N H362N H363N H364N H365N H366N H367N H368N
Fusible, Three-Pole, Four-Wire, 600 Vac, NEMA 3R 30 60 DH361NRK DH362NRK DH363NRK DH364NRK DH365NRK DH366NRK DH367NRK DH368NRK TH3361R 1 TH3362R 1 TH3363R
1
Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 DH461FGK DH462FGK DH463FGK DH464FGK DH465FGK DH466FGK TH6661 TH6662 TH6663 TH6664 N/A N/A N/A N/A N/A N/A N/A N/A H461 H462 H463 H464 H465 H466
TH3364R 1 TH3365R
1
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 800 1200 DH261UGK DH362UGK DH263UGK DH364UGK DH265UGK DH266UGK DH267UGK N/A THN2261DC THN2262DC THN2263DC N/A N/A N/A N/A N/A HNF261 HNF262 HNF263 N/A HNF265 HNF266 N/A N/A HU361 HU362 HU363 HU364 HU265 HU266 HU267 HU268
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 3R 30 60 100 200 400 600 800 1200 DH361URK DH362URK DH363URK DH364URK DH365URK DH366URK DH367URK DH368URK THN2261RDC THN2262RDC THN2263RDC N/A N/A N/A N/A N/A HNF261R HNF262R HNF263R N/A HNF265R HNF266R N/A N/A HU361RB HU362RB HU363RB HU364RB HU265R HU266R HU267R HU268R
Notes 1 Separate neutral kit required. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
www.eaton.com
V2-T1-9
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-10 Ampere Rating Catalog Number Eaton
Switching Devices
Safety Switches
Heavy-Duty, continued
General Electric Siemens Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 3R 30 60 100 200 DH461UDK DH462UDK DH463UDK DH464UDK THN6661 THN6662 THN6663 THN6664 N/A N/A N/A N/A N/A N/A N/A N/A
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 DH461UWK N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A HU461DS HU462DS HU464DS HU464DS
Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 400 600 800 DH261FWK DH362FWK DH363FWK DH264FWK DH365FWK DH366FWK DH367FWK TH2261SSDC TH2262SSDC TH2263SSDC N/A N/A N/A N/A HF261S HF262S HF263S N/A HF265S HF266S N/A H361DS H362DS H363DS H364DS H265DS H266DS N/A
Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH261FDK DH262FDK DH263FDK DH264FDK DH265FDK DH266FDK DH267FDK N/A TH2261JDC TH2262JDC TH2263JDC N/A N/A N/A N/A N/A HF261J HF262J HF263J N/A HF265J HF266J N/A N/A H361AWK H362AWK H363AWK H364AWK H265AWK H266AWK H267AWK H268AWK
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 400 600 800 DH361FWK DH362FWK DH363FWK DH364FWK DH365FWK DH366FWK DH367FWK TH3361SS TH3362SS TH3363SS TH3364SS TH3365SS TH3366SS N/A HF361S HF362S HF363S HF364S HF365S HF366S HF367S H361DS H362DS H363DS H364DS H365DS H366DS N/A
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH361FDK DH362FDK DH363FDK DH364FDK DH365FDK DH366FDK DH367FDK N/A TH3361J TH3362J TH3363J TH3364J TH3365J TH3366J N/A N/A HF361J HF362J HF363J HF364J HF365J HF366J HF367J N/A H361AWK H362AWK H363AWK H364AWK H365AWK H366AWK H367AWK H368AWK
Fusible, Three-Pole, Four-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 400 600 DH361NWK DH362NWK DH363NWK DH364NWK DH365NWK DH366NWK TH3361SS 1 TH3362SS 1 TH3363SS 1 TH3364SS 1 TH3365SS 1 TH3366SS
1
Fusible, Three-Pole, Four-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH361NDK DH362NDK DH363NDK DH364NDK DH365NDK DH366NDK DH367NDK N/A THN3361J 1 THN3362J 1 THN3363J 1 THN3364J
1
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 400 600 800 DH361UWK DH362UWK DH363UWK DH364UWK DH365UWK DH366UWK DH367UWK THN2261SSDC THN2262SSDC THN2263SSDC N/A N/A N/A N/A HNF261S HNF262S HNF263S N/A HNF265S HNF266S N/A HU361DS HU362DS HU363DS HU364DS HU265DS HU266DS N/A
Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 12 30 60 100 200 400 N/A N/A DH463FDK DH464FDK N/A TH6661 TH6662 TH6663 TH6664 N/A N/A N/A N/A N/A N/A H461AWK H462AWK H463AWK H464AWK H465AWK
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 4/4X Stainless Steel 30 60 100 200 400 600 800 DH361UWK DH362UWK DH363UWK DH364UWK DH365UWK DH366UWK DH367UWK THN3361SS THN3362SS THN3363SS THN3364SS THN3365SS THN3366SS N/A HNF361S HNF362S HNF363S HNF364S HNF365S HNF366S HNF367S HU361DS HU362DS HU363DS HU364DS HU365DS HU366DS N/A
Notes 1 Separate neutral kit required. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
Square D
Heavy-Duty, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Heavy-Duty Six-Pole
Ampere Rating Catalog Number Eaton General Electric Siemens
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH261UDK DH262UDK DH263UDK DH264UDK DH265UDK DH266UDK DH267UDK N/A THN2261JDC THN2262JDC THN2263JDC N/A N/A N/A N/A N/A HNF261J HNF262J HNF263J N/A HNF265J HNF266J N/A N/A HU361AWK HU362AWK HU363AWK HU364AWK HU265AWK HU266AWK HU267AWK HU268AWK
Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 3R 30 60 100 200 DH661FDK DH662FDK DH663FDK DH664FDK TH6661 TH6662 TH6663 TH6664 F651H F652H F653H N/A N/A N/A N/A N/A
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 12 30 60 100 200 DH661FDK DH662FDK DH663FDK DH664FDK TH6661 TH6662 TH6663 TH6664 F651H F652H F653H N/A N/A N/A H663AWK H664RWK
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 800 1200 DH361UDK DH362UDK DH363UDK DH364UDK DH365UDK DH366UDK DH367UDK N/A THN3361J THN3362J THN3363J THN3364J THN3365J THN3366J N/A N/A HNF361J HNF362J HNF363J HNF364J HNF365J HNF366J HNF367J N/A HU361AWK HU362AWK HU363AWK HU364AWK HU365AWK HU366AWK HU367AWK HU368AWK
Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 4X 30 60 100 200 N/A N/A N/A N/A N/A N/A N/A N/A F651SS F652SS F653SS N/A N/A N/A H663DS H664DS
Non-Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 3R 30 60 100 DH661UDK DH662UDK DH663UDK DH664UDK THN6661 THN6662 THN6663 THN6664 NF651H NF652H NF653H N/A N/A N/A N/A N/A
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 12 30 60 100 200 400 DH461UDK DH462UDK DH463UDK DH464UDK N/A THN6661 THN6662 THN6663 THN6664 N/A N/A N/A N/A N/A N/A HU461AWK HU462AWK HU463AWK HU464AWK HU465AWK
200
Non-Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 12 30 60 100 200 DH661UDK DH662UDK DH663UDK DH664UDK THN6661 THN6662 THN6663 THN6664 NF651H NF652H NF653H N/A HU661AWK HU662AWK HU663AWK HU664RWK
Non-Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 4X 30 60 100 200 DH661UWK DH662UWK DH663UWK DH664UWK N/A N/A N/A N/A NF651SS NF652SS NF653SS N/A HU661DS HU662DS HU663DS HU664DS
Note Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
www.eaton.com
V2-T1-11
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-12
Switching Devices
Safety Switches
Double-Throw
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Double-Throw, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DT321FGK DT322FGK DT323FGK DT224FGK DT325FGK DT326FGK TDT3321 TDT3322 TDT3323 TDT3324 TDT3325 TDT3326 N/A N/A N/A DTF224 N/A N/A N/A N/A DT223 DT224 N/A N/A
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 800 DT321 DT322 DT323 DT324 N/A N/A 1200 DT361UGK DT362UGK DT363UGK DT364UGK DT365UGK DT366UGK DT367UGK N/A TC35361 TC35362 TC35363 TC35364 TC35365 TC35366 N/A N/A DTNF361 DTNF362 DTNF363 DTNF364 DTNF365 DTNF366 DTNF367 N/A DTU361 DTU362 DTU363 DTU364 92345 92346 N/A N/A
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 DT321FGK DT322FGK DT323FGK DT324FGK DT325FGK DT326FGK TDT3321 TDT3322 TDT3323 TDT3324 TDT3325 TDT3326 DTF321 DTF322 DTF323 DTF324 DTF325 DTF326
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 1 30 60 100 200 400 N/A N/A N/A DT464UGK DT465UGK DT466UGK DT467UGK N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NF454DTK NF455DTK NF456DTK NF457DTK N/A DTU462 DTU463 DTU464 92445 92446 N/A
Non-Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 DT221UGK DT222UGK DT223UGK DT224UGK DT225UGK DT226UGK DT327UGK N/A N/A N/A N/A N/A N/A N/A DTNF221 DTNF222 DTNF223 DTNF224 DTNF225 DTNF226 N/A 92251 DTU222 DTU223 DTU224 92255 N/A N/A
600 800
Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 3R 30 60 100 200 DT321FRK DT322FRK DT323FRK DT224FRK TDT3321R TDT3322R TDT3323R TDT3324R N/A N/A N/A DTF224R N/A N/A DT223RB DT224RB
Non-Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 1 30 60 100 200 400 600 800 DT321UGK DT322UGK DT323UGK DT324UGK DT325UGK DT326UGK DT327UGK TC35321 TC35322 TC35323 TC35324 TC35325 TC35326 N/A DTNF321 DTNF322 DTNF323 DTNF324 DTNF325 DTNF326 DTNF327 DTU321 DTU322 DTU323 DTU324 92355 92356 N/A
Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 100 200 400 600 DT321FRK DT322FRK DT323FRK DT324FRK DT325FRK DT326FRK TDT3321R TDT3322R TDT3323R TDT3324R N/A N/A DTF321R DTF322R DTF323R DTF324R FR325DTK FR326DTK DT321RB DT322RB DT323RB DT324RB N/A N/A
Non-Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 3R 30 N/A N/A DT323URK DT224URK DT225URK N/A N/A N/A N/A N/A N/A N/A N/A DTNF224R DTNF225R N/A N/A DTU223RB DTU224RB 92255R
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 DT361FGK DT362FGK DT363FGK DT364FGK DT365FGK N/A TDT3361 TDT3362 TDT3363 TDT3364 TDT3365 N/A DTF361 DTF362 DTF363 DTF364 DTF365 N/A DT361 DT362 DT363 DT364 N/A N/A
Non-Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 3R 30 60 N/A N/A DT323URK DT324URK DT325URK N/A N/A N/A N/A N/A N/A N/A N/A N/A DTNF323R DTNF324R N/A N/A N/A N/A DTU323RB DTU324RB 92355R 92356R
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 1 30 60 100 200 400 600 DT261UGK DT262UGK DT263UGK DT264UGK DT265UGK DT266UGK N/A N/A N/A N/A N/A N/A DTNF261 DTNF262 DTNF263 DTNF264 DTNF265 DTNF266 N/A 82342 82343 82344 92345 92346
Note Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
Square D
Double-Throw, continued
Ampere Rating Catalog Number Eaton General Electric Siemens Square D
Double-Throw, continued
Ampere Rating Catalog Number Eaton General Electric Siemens
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 3R 30 60 100 200 400 N/A N/A DT363FRK DT364FRK DT365FRK N/A N/A N/A N/A N/A N/A N/A DTF363R DTF364R FR355DTK DT361RB DT362RB DT363RB DT364RB N/A
Non-Fusible, Four-Pole, Four-Wire, 240 Vac, NEMA 12 30 60 100 200 400 600 N/A 82342RB 82343RB 82344RB 92345RB 92346RB N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H92451 DTU462AWK DTU463AWK DTU464AWK H92455 H92456
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 3R 30 60 100 200 400 600 N/A N/A N/A DT264URK DT265URK DT266URK N/A N/A N/A N/A N/A N/A N/A N/A N/A DTNF264R DTNF265R NFR256DTK
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 DT361UDK DT362UDK DT363UDK DT364UDK DT365UDK N/A N/A N/A N/A N/A N/A N/A DTNF361J DTNF362J DTNF363J DTNF364J NF355HDTK N/A N/A H82342 H82343 H82344 H92345 H92346
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 3R 30 60 100 200 400 600 800 DT361URK DT362URK DT363URK DT364URK DT365URK DT366URK DT367URK N/A N/A N/A N/A N/A N/A N/A DTNF361R DTNF362R DTNF363R DTNF364R DTNF365R DTNF366R DTNF367R DTU361RB DTU362RB DTU363RB DTU364RB 92345RB 92346RB N/A
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 DT361UDK DT362UDK DT363UDK DT364UDK DT365UDK N/A N/A N/A N/A N/A N/A N/A DTNF361J DTNF362J DTNF363J DTNF364J NF355HDTK N/A N/A DTU362AWK DTU363AWK DTU364AWK H92345 H92346
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 3R 30 60 100 200 400 600 800 DT461URK DT462URK DT463URK DT464URK DT465URK DT466URK DT467URK N/A N/A N/A N/A N/A N/A N/A NFR451DTK NFR452DTK NFR453DTK NFR454DTK NFR455DTK NFR456DTK NFR457DTK N/A 92442RB 92443RB 92444RB 92445R 92446R N/A
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 12 30 60 100 200 400 600 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DTU462AWK DTU463AWK DTU464AWK H92445 H92446
Non-Fusible, Two-Pole, Two-Wire, 600 Vac, NEMA 4X 30 DT361UWK DT362UWK DT363UWK DT364UWK DT365UWK N/A N/A N/A N/A N/A DTNF361S DTNF362S DTNF363S DTNF364S NF355SSDTK N/A 82342DS 82343DS 82344DS N/A
Non-Fusible, Six-Pole, Six-Wire, 600 Vac, NEMA 3R 30 60 100 DT661URK DT662URK DT663URK N/A N/A N/A NFR651DTK NFR652DTK NFR653DTK N/A N/A N/A
Non-Fusible, Two-Pole, Two-Wire, 240 Vac, NEMA 12 1 30 60 100 200 400 DT361UDK DT362UDK DT363UDK DT364UDK DT365UDK N/A N/A N/A N/A N/A DTNF361J DTNF362J DTNF363J DTNF364J NF355HDTK H92251 H82252 H82253 H82254 H92255
Non-Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 4X 30 60 100 200 400 DT361UWK DT362UWK DT363UWK DT364UWK DT365UWK N/A N/A N/A N/A N/A DTNF361S DTNF362S DTNF363S DTNF364S NF355SSDTK N/A DTU362DS DTU363DS DTU364DS N/A
Non-Fusible, Three-Pole, Three-Wire, 240 Vac, NEMA 12 1 30 60 100 200 400 600 DT361UDK DT362UDK DT363UDK DT364UDK DT365UDK N/A N/A N/A N/A N/A N/A N/A DTNF361J DTNF362J DTNF363J DTNF364J NF355HDTK N/A H92351 DTU362AWK DTU363AWK DTU364AWK H92355 H92356
Notes 1 Eaton and Siemens switches shown are 600V switches. Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
www.eaton.com
V2-T1-13
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-14 Ampere Rating Catalog Number Eaton
Switching Devices
Safety Switches
Double-Throw, continued 1
General Electric Siemens Square D
Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 60 100 200 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DTU462DS DTU463DS DTU464DS
Fusible, Three-Pole, Three-Wire, 600 Vac, NEMA 4X 30 60 100 200 400 DT361FWK DT362FWK DT363FWK DT364FWK DT365FWK N/A N/A N/A N/A N/A F351SSDTK F352SSDTK F353SSDTK F354SSDTK F355SSDTK N/A N/A N/A N/A N/A
DH 3 6 1 N D K LW
Switch Type DP = General-duty/plug fuse DG = General-duty/cartridge fuse DH = Heavy-duty DT = Double-throw DR = Rotary switch DS = Classified location with DS interior Options 2 Poles/Blades 1 = 1-pole 2 = 2-pole 3 = 3-pole 4 = 4-pole 6 = 6-pole Ampere Rating = 30A = 60A = 100A = 200A = 400A = 600A = 800A = 1200A NEMA Enclosure Ratings G = NEMA 1 R = NEMA 3R D = NEMA 12 or 12/3R P = NEMA 4 (painted steel) W = NEMA 4X (corrosion-resistant (304 Grade stainless steel) C = NEMA 4X non-metallic (for Type DH) X = NEMA 7/9 (for Type DS) X = NEMA 4X non-metallic (for Type DR) Fusible/Non-Fusible or Neutral F = Fusible without neutral U = Non-fusible N = Fusible with neutral W = Upper viewing window 3 LW = Lower viewing window 3 X = EnviroLine stainless (enclosure and mechanism) GCL = Mill-duty Series K = Design all general-duty switches above 200A and all heavy-duty switches incorporate K-Series switch design features listed below B = Design general-duty 30100A H = General-duty double-throw switch (compact design 30100A)
1 2 3 4 5 6 7 8
Notes 1 Always verify the number of poles and wires required since catalog numbers may appear in multiple tables. 2 See Pages V2-T1-17 through V2-T1-20 for additional Flex Center options. 3 Effective August 2003, 30100A window switches are replaced by a full view window that allows blade position verification and blown fuse indication. See Page V2-T1-37 for catalog numbers. This table is intended for use in breaking down existing catalog numbers. It is not intended for building new catalog numbers.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Lubricating grease for safety switch blades and DSLUBEKIT contacts (each kit contains three 30 cc tubes of lubricating grease) Notes 1 Ground bar kit is not listed on device publications. 2 Order one kit for three poles. 3 Order one kit for each pole. 4 Order one kit per switch. 5 Receptacle switches. 6 Order one kit for six poles. Accessories are not applicable to NEMA 7/9 switches unless indicated otherwise. A factory-installed ground lug is supplied on all NEMA 4, 4X and 12 safety switches, as well as all 400A and higher NEMA 1 and 3R safety switches. A factory-installed ground lug is also supplied on all heavy-duty NEMA 1 and 3R 30200A switches that do NOT have a factoryinstalled neutral.
www.eaton.com
V2-T1-15
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-16 DS050MH
Switching Devices
Safety Switches
Myers Type Hubs NEMA 3R (400A and above) NEMA 4, 4X (stainless steel), 12
Catalog Number DS050MH DS075MH DS100MH DS125MH DS150MH DS200MH DS250MH DS300MH DS350MH DS400MH DS500MH Conduit Size 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) 3.50 (88.9) 4.00 (101.6) 5.00 (127.0)
Contact the Flex Center at 1-888-329-9272 for information on hubs for non-metallic NEMA 4X switches.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
ModificationsFlex Center
Introduction The Safety Switch Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety switches that meet customers challenging applications. Eatons Flex Center is a solutions center that provides real value:
Description Nameplates Fungus proofing Special paint Lock-on provisions on heavy-duty safety switches for most enclosure types Trapped key interlock systems Upper cover viewing window Lower cover viewing window Neutral assemblies factory installed for double-throw safety switches Class R fuse clips factory installed for heavy-duty switches Class T fuse clips factory installed for heavy-duty switches Class J fuse clips factory installed for heavy-duty and doublethrow safety switches Fuse pullers factory installed Special crimp lug pads factory installed for general-duty and heavyduty switches Copper lugs factory installed Equipment ground lugs factory installed Custom lug configurations Auxiliary contacts factory installed Control pole factory installed Switching neutral double-throw Neutral assemblies factory installed for single-throw non-fusible safety switches How to order How to price
Suffix NP FP
Item 1 2 3
LO
TK W LW N
5 6 7 8
A dedicated and knowledgeable engineering/ manufacturing/customer service team to meet your needs A production facility stocked with a full arsenal of equipment to get the job done The industrys shortest lead-time Easy ordering through our distributors
1. Nameplates Price covers up to three lines of text with a maximum of 25 characters per line. Standard nameplates are laser-engraved plastic and have black letters on a white background. Rotary-engraved phenolic nameplates are also available at a premium. Additional color combinations and larger nameplates are available. Contact the Flex Center for price and availability for these special requirements. Customer must specify the text when placing an order. Item 1
Description Plastic nameplateup to three lines Phenolic nameplateup to three lines
3. Special Paint Special paint colors are available for order quantities of five or more switches. Colors available are red, orange, yellow, green, black and white. Custom color is applied over the standard ANSI-61 gray finish. Minimum quantity of five of the same color is required. Order by description. For quantities less than five, higher ampere ratings, or other color request, contact the Safety Switch Flex Center. Item 3
Ampere Rating 30 60 100
5 or 6
10
11
FE CK
12 13
CL G L 2 or 3 CP SN N
14 15 16 17 18
2. Fungus Proofing All non-metallic components of the switch are coated with a moisture and fungusresistant varnish. The inhibitor used meets military specification: MIL-V-173C for MOISTURE AND FUNGUSRESISTANT TREATMENT. The treated switch meets military specification: MIL-T-152E for MOISTURE AND FUNGUS-RESISTANT TREATMENT OF COMMUNICATIONS, ELECTRONICS AND ASSOCIATED EQUIPMENT. Not UL listed. Item 2
4. Lock-On Provisions on Heavy-Duty Safety Switches for Most Enclosure Types Available on 30800A heavyduty and double-throw safety switches. Provision will accept a single lock. To order, add Suffix LO to the standard catalog number. Example: DH362FRKLO.
19 20
21 22
To order, add Suffix FP to standard safety switch catalog number. Example: DH363FGKFP.
www.eaton.com
V2-T1-17
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-18
Switching Devices
Safety Switches
5. Trapped Key Interlock Systems Available only on heavy-duty and double-throw safety switches. Trapped key systems are used on safety switches to prevent unauthorized operations or to predetermine a series of power transfers by an authorized operator. Before system construction can begin, the following information must be provided to the Flex Center:
7. Lower Cover Viewing Window Lower viewing window is positioned over fuses and provides visual verification of blown fuse indicators for Littelfuse, Inc. fuses. Available in 200600A, twoand three-pole heavy-duty NEMA 4X stainless steel and NEMA 12/3R enclosures. Not available on nonmetallic enclosures. To order, add Suffix LW to standard catalog number.
Note: 30100A window switches are now provided with a full view cover window for blade verification and blown fuse indication.
11. Class J Fuse Clips Factory Installed for Heavy-Duty and DoubleThrow Safety Switches Item 11
Voltage 240 and 600 240 and 600 240 and 600 240 and 600 240 and 600 240 and 600
Ampere Rating 30
Switch Type Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Heavy-duty and double-throw Double-throw Heavy-duty Heavy-duty
60
240 600
Username, address and telephone number Complete coordination (lock scheme) required with order
To order, add Suffix TK to the standard catalog number. Example: DH363FWKTK. Item 5
Ampere Rating 301200 30800 Switch Type Heavy-duty Double-throw
Items 6 and 7
Viewing Window (Upper or Lower) Ampere Rating 30200 400800
To order, add Suffix 5 to the standard catalog number for 240V application. Add Suffix 6 to standard catalog number for 600V application. Total price is the standard catalog number price plus the price adder from the table above depending on the number of safety switch poles. Example: DH324FRK5 heavyduty, three-pole, 200A switch at 240V with factory-installed Class R fuse clips. 10. Class T Fuse Clips Factory Installed for Heavy-Duty Switches Item 10
Ampere Rating 200 Voltage 240 600 400 240 600 600 240 600 800 240 600 1200 240 600
100
240 600
200
240 600
400 600
Contact the Safety Switch Flex Center for lead-time. 8. Neutral Assemblies Factory Installed for DoubleThrow Safety Switches Item 8
Ampere Rating 30 60 100 200 400 600 400 600 800 Switch Type Two- and Three-Pole Fusible and non-fusible Fusible and non-fusible Fusible and non-fusible Fusible and non-fusible Non-fusible Non-fusible Fusible Fusible Non-fusible
6. Upper Cover Viewing Window Upper viewing window is centered over the switching contacts to provide visual verification of ON/OFF status. Available on most heavy-duty NEMA 4X stainless steel and NEMA 12/3R and doublethrow enclosures. Not available on non-metallic enclosures. To order, add Suffix W to the standard catalog number.
Note: 30100A window switches are now provided with a full view cover window for blade verification and blown fuse indication.
Total price is the standard catalog number price plus the price adder from the table above depending on the number of safety poles. Order by description. A table of common 30A heavy-duty switches with J fuse clips factory installed is shown on Page V2-T1-19 (field modification kits are not available for 30A heavyduty switches).
To order, add Suffix N on non-fusible switches OR replace 6th character F with N on fusible switches. The total price is the standard switch price plus the price adder. Example 1: DT361URKN non-fusible double-throw, three-pole, 30A switch with factory-installed neutral assembly. Example 2: DT363NRK fusible double-throw, three-pole, 100A switch with factory-installed neutral assembly.
To order, add Suffix T to the standard catalog number (catalog number identifies voltage). Total price is the standard catalog number price plus the price adder depending on the number of safety switch poles. Example: DH364FGKT heavyduty, three-pole, 200A fusible switch at 480V with factoryinstalled Class T Fuse Clips.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
13. Special Crimp Lug Pads Factory Installed for General-Duty and HeavyDuty Switches (Crimp Lugs are Not Included) To order add Suffix CK to the standard safety switch catalog number. Item 13
Ampere Rating 400600 800
16. Custom Lug Configurations Customer-specified lug arrangements are available on heavy-duty and double-throw safety switches. Contact the Safety Switch Flex Center for price and lead-time. 17. Auxiliary Contacts Factory Installed Provide Early-Make/Early-Break Operation Item 17
General-Duty Switches 200600A, Non-Metallic 30200A, Heavy-Duty 301200A and Double-Throw Switches 30800A Ampere Rating 30200 4001200 Description 1NO/1NC 2NO/2NC
To order, add Suffix J to the standard catalog number (catalog number identifies voltage). Total price is the standard catalog number price plus the price adder depending on the number of safety switch poles. Example: DH363FGKJ heavyduty, three-pole, 200A fusible switch at 480V with factoryinstalled Class J fuse clips. 12. Fuse Pullers Factory Installed Item 12
Ampere Rating 3060 100 200 Switch Type Heavy-duty Heavy-duty General-duty and heavy-duty
Heavy-duty Type DH switches, 30200A are adaptable to crimp lugs, simply remove the box lugs. 14. Copper Lugs Factory Installed Item 14
Ampere Rating 30 Switch Type Heavy-duty Double-throw 60 Heavy-duty Double-throw 100 Heavy-duty Double-throw 200 400 600 Heavy-duty General-duty and heavy-duty General-duty and heavy-duty
18. Control Pole Factory Installed Provides Late-Make/Early-Break Operation The K-Series control pole provides one normally open contact, late-make, earlybreak operation. It mounts in the exact location as the neutral block using the same pre-drilled holes. This is directly connected to the power pole operating shaft. Direct connection and visible blades provide more secure electrical interlocking than handle linkage operation of a snap/switch type interlock. This reliability meets the requirements of many specifications for four-pole switches when the fourth pole is required for secure electrical interlocking. Item 18
Ampere Rating 301200 30200 400600 Switch Type Heavy-duty Double-throw General-duty
1NO/1NC 2NO/2NC
To order 1NO/1NC contacts, add Suffix 2 to the standard safety switch catalog number. To order 2NO/2NC contacts, add Suffix 3 to the standard safety switch catalog number. The total price is the standard switch price plus the price adder. Example: DH423FGK2 Heavy-duty, four-pole, 100A fusible switch at 240V with factory-installed 1NO/1NC contacts. Example: DT324FGK22 double-throw, three-pole, 200A fusible switch at 240V with two factory-installed contacts (one installed in the normal ON position and one installed in the auxiliary ON position).
To order, add Suffix CP to the standard safety switch catalog number. The total price is the standard switch price plus the price adder. Example: DH267FGKCP heavy-duty, two-pole, 800A fusible switch at 480V with factory-installed control pole.
To order, add Suffix CL to the standard safety switch catalog number. The total price is the standard switch price plus the price adder. Example: DH221FGKCL heavy-duty, two-pole, 30A fusible switch at 240V with copper lugs factory installed. 15. Equipment Ground Lugs Factory Installed for General-Duty and HeavyDuty Switches Item 15
Ampere Rating 30100 200 4001200
To order, add Suffix G to the standard Safety Switch Catalog Number. The total price is the standard switch price plus the price adder.
www.eaton.com
V2-T1-19
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-20
Switching Devices
Safety Switches
19. Switching Neutral Double-Throw UL listed for three-pole and four-pole non-fusible doublethrow safety switches. Switching neutrals are required for separately derived systems when bonding the neutral of the generator to a grounding system at the generator. Item 19
Ampere Rating 30200 400 600 800
20. Neutral Assemblies Factory Installed for Single-Throw Non-Fusible Safety Switches Available on 200600A general-duty safety switches and 301200A heavy-duty safety switches. Item 20
Ampere Rating 3060 100 200 NEMA 4, 4X, 12 200 NEMA 1, 3R 400 600 800 1200
22. How to Price Step One: Select catalog number from Pages V2-T115 through V2-T1-84 of this catalog or Vista of the switch that needs to be modified. Step Two: Use the correct price (from Vista or the current Price and Availability Digest) of the switch that needs to be modified. If no price exists, Flex Center will provide one. Step Three: Refer to the modification on Pages V2-T117 through V2-T1-20 for price additions. Example: DT363URK Options: factory installed Neutral (N) Copper lugs (CL) (3 x 120.00) Step Four: Contact the Safety Switch Flex Center for authorized price and lead-time.
Note: Existing DSP CSP and DOP , pricing does not apply.
Additional Safety Switch Flex Center Design Offerings Left-hand design (30200A) Cover-mounted status lights and selector switches Integrated: Transient Voltage Surge Suppression (TVSS) Current transformers
To order, add Suffix SN to the standard safety switch catalog number. The total price is the standard switch price plus the price adder. Example: DT324URKSN non-fusible double-throw, three-pole, 200A switch with factory-installed switching neutral.
Double-throw receptacle switches 200% neutrals Seam-welded stainless steel Gang-operated kits: Mechanically interlocks two or three separate switches Cam-Lok and Posi-Lok receptacles Reverse feed Integrated wattmeter Custom enclosures Double-throw switches with windows 316 grade stainless steel Breather/drains Voltage/phase monitor
To order, add Suffix N to the standard safety switch catalog number. Example: DH364UWKN Heavy-duty, three-pole, 200A, NEMA 4X. 21. How to Order Step One: Contact the Safety Switch Flex Center for price and delivery on product being modified. An authorized negotiation (TSP) number will be provided to track your order. Safety Switch Flex Center Phone: 1-888-329-9272 Fax: 1-423-478-0270 Step Two: Enter the order on VISTALINE by description (with catalog number if it applies) and reference the authorized negotiation (TSP) number. Vista suffix will be ETS. Product code will be BE90. For order entry assistance, contact CSC at: Phone: 1-800-356-1243 Fax: 1-800-752-8602
For application, availability or pricing questions, contact the Safety Switch Flex Center at 1-888-329-9272.
Literature The Safety Switch Flex Centers innovative approach to flexible engineering, manufacturing and customer service provides the shortest production, design and delivery cycle in the industry. Find out more about how the Safety Switch Flex Center can give you the safety switch solution you need...when you need them. Order Sales Aid SA00801002E from Eatons Literature Fulfillment Center by calling 1-800-957-7050.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Dimensions
Approximate Dimensions in Inches (mm)
DS075H1
1 1 1 1 1 1 1 1 1
Catalog number DS900AP adapter kit permits Installation of Group 1 hubs on 200A type general-duty, heavy-duty and double-throw switches.
Notes 1 The maximum size aluminum or copper-clad aluminum wire allowable for applications where the conductor enters or leaves the enclosure through the wall opposite its terminal is #1 gauge. Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in NEC Tables 373-6 (a) and (b) for respective ampere ratings.
www.eaton.com
V2-T1-21
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-22
Switching Devices
Safety Switches
Class T
T-Tron Fuses JJN (300V) JJS (600V)
Class J
Low-Peak and Limitron Fuses LPJ & JKS (600V)
250V
Ampere 1/1030 3560 A 2.00 3.00 A
B
600V
B 0.56 0.81 A 5.00 5.50 B 0.81 1.06
250V
Ampere 70100 110200 225400 450600 Low-Peak A 5.88 7.13 8.63 10.38 B 1.06 1.56 2.06 2.59
600V
A 7.88 9.63 11.63 13.38 B 1.34 1.84 2.59 3.13
250V
Ampere 70100 110200 225400 450600 A 5.88 7.13 8.63 10.38 B 1.16 1.66 2.38 2.88
600V
A 7.88 9.63 11.63 13.38 B 1.16 1.66 2.38 2.88
Class L
Low-Peak and Limitron Fuses KRP-C, KTU & KLU (6014000A) (600V)
Note: KRP-CL (150600A) fuses have same dimensions as 601800A case size. KTU (200600A) have same dimensions, except tube 3-inch lgth. x 2-inch dia.; terminal 1.63-inch width x 1.25-inch thick.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1
B 20.6 27.0
Class T
T-Tron Fuses JJN (300V) JJS (600V)
Class J
Low-Peak and Limitron Fuses LPJ and JKS (600V)
250V
Ampere 1/1030 3560 A 50.8 76.2 A
B
600V
A 127.0 139.7
B 14.3 20.6
1 1 1 1
250V
Ampere 70100 110200 225400 450600 Low-Peak A 149.2 181.0 219.1 263.5 B 26.9 39.6 52.3 65.8
600V
A 200.0 244.5 295.3 339.7 B 34.0 46.7 65.8 79.5
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
250V
Ampere 70100 110200 225400 450600 A 149.2 181.0 219.1 263.5 B 29.5 42.2 60.5 73.2
600V
A 200.0 244.5 295.3 339.7 B 29.5 42.2 60.5 73.2
Class L
Low-Peak and Limitron Fuses KRP-C, KTU and KLU (6014000A) (600V)
Note: KRP-CL (150600A) fuses have same dimensions as 601800A case size. KTU (200600A) have samedimensions, except tube 76.2 mm lgth. x 50.8 mm dia.; terminal 41.3 mm width x 31.8 mm thick.
www.eaton.com
V2-T1-23
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-24
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-25 V2-T1-25 V2-T1-26 V2-T1-28 V2-T1-28 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
General Duty
Product Description
30600A Suitable for service entrance applications unless otherwise noted Fusible and non-fusible switches are 100% load break and 100% load make rated The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated 200600A features K-Series design Horsepower rated Fusible and non-fusible switches. Single-pole S/N through four-wire; 120/240, and 240 Vac
With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical
120/240 Vac General-Duty, Fusible, Single-Throw 30600A Suitable for service entrance applications unless otherwise noted Horsepower rated Bolt-on hub provision. Provided for general-duty switches in a NEMA 3R enclosure. See Page V2-T121 for selection 200600A switches incorporate K-Series design
Non-Fusible Switches The UL listed short-circuit ratings for Eatons non-fusible switches are based on the switches being properly protected by overcurrent protective devices. For applications that require a UL listed short-circuit rating of 10,000A rms symmetrical or less, an Eaton non-fusible switch must be properly protected by any overcurrent protective device rated no greater than the ampere rating of the switch. For applications that require a UL listed short-circuit rating of greater than 10,000 rms symmetrical amperes, an Eaton non-fusible switch must be properly protected by the appropriate class and size fusing noted on the switch publication (located on the inside cover).
Otherwise, this non-fusible switch must be replaced with an Eaton fusible switch that utilizes the appropriate fusing required. Molded case circuit breaker protection of nonfusible Eaton switches for applications that require a short-circuit rating of greater than 10,000A rms symmetrical has not been evaluated. Refer to the reference tables for typical Eaton fusible switch UL listed short-circuit ratings.
Note: Safety switch short-circuit ratings are applicable to AC only. Safety switch l2t and lp values are identical to UL maximum acceptable l2t and lp values for the corresponding class fuse.
Application Description
For residential and commercial applications. Suitable for light-duty motor circuits and service entrance.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1
Tangential Knockouts
The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation
An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A
Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life
Clearly Visible Handle
Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks
1 1 1 1 1 1 1
For switches in a NEMA Type 3R, 30200A. Use a Myers type hub for all others
Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not typically provided on general-duty switches, but available as a field kit or factory installed
1 1 1 1 1 1
Cabinet door can be further padlocked at the top and bottom as applicable
UL listed File No. E5239 Meets UL 98 for enclosed switches and NEMA Std. KS-1
1 1 1 1 1 1 1 1 1 1
www.eaton.com V2-T1-25
Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on singlethrow switches
Interlocking Mechanism
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-26
Switching Devices
Safety Switches
Product Selection
120/240 Vac General-Duty, Fusible, Single-Throw
Maximum Horsepower Ratings 1 System Ampere Rating Fuse Type Provision Single-Phase AC 120V 240V Three-Phase AC 240V DC 250V NEMA 1 Enclosure Indoor Catalog Number NEMA 3R Enclosure Rainproof Catalog Number
DP221NGB
Plug TypeTwo-Wire (One Blade, One Fuse, S/N)120 Vac 2 30 S/N Plug (Type S, T or W) 1/22 DP111NGB
Plug TypeThree-Wire (Two Blades, Two Fuses, S/N)120/240 Vac 30 S/N Plug (Type S, T or W) 1/22 1-1/23 DP221NGB Use cartridge-type fuse catalog number DG221NRB
Cartridge TypeTwo-Pole Two-Wire (Two Blades, Two Fuses)240 Vac 30 60 100 200 400 600 H H 1-1/23 310 7-1/215 15 37-1/2 7-1/215 1530 2560 50125 75200
3 3 3 3 3 3 3 3 45 45
Cartridge TypeThree-Wire (Two Blades, Two Fuses, S/N)120/240 Vac 30 S/N 60 100 200 400 600 H H H H H H 1-1/23 310 7-1/215 15 37-1/2 6 7-1/215 6 1530 6 2560 6 50125 6 75200 6 50 DG221NGB DG222NGB DG223NGB DG224NGK DG225NGK DG226NGK DG221NRB DG222NRB DG223NRB DG224NRK DG225NRK DG226NRK
Notes 1 Maximum hp ratings apply only when dual element time delay fuses are used. 2 These switches do not have an interlock that prevents door from being opened when switch is in the ON position. 3 Use three-wire catalog numbers below. 4 Solid neutral bars are not included. Order separately from table on Page V2-T1-15. 5 WARNING! Switch is not approved for service entrance unless a neutral kit is installed. 6 Grounded B phase rating, UL listed. All general-duty safety switches are individually packaged. Accessories are limited in scope on general-duty safety switches. See Page V2-T1-15 for availability. In addition, clear line shields are available as an accessory on 200600A general-duty switches. Catalog Numbers: 200A = 70-7759-11, 400A = 70-8063-8, 600A = 70-8064-8.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 3R Enclosure Rainproof Catalog Number
DG321NRB
1 1 1 1 1 1 1 1 1 1 1 1
Cartridge TypeThree-Pole, Three-Wire (Three Blades, Three Fuses)240 Vac 30 60 100 200 400 600 H H 50125 75200
2 2 2 2 2 2 2 2
DG325FGK 34 DG326FGK 34
DG325FRK 34 DG326FRK 34
Cartridge TypeFour-Wire (Three Blades, Three Fuses, S/N)120/240 Vac 30 S/N 60 100 200 400 600 H H H H H H 1-1/23 310 7-1/215 15 37-1/2 7-1/215 1530 2560 50125 75200 DG321NGB DG322NGB DG323NGB DG324NGK DG325NGK DG326NGK DG321NRB DG322NRB DG323NRB DG324NRK DG325NRK DG326NRK
DG322URB
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Two-Pole, Two-Wire (Two Blades)240 Vac 30 60 100 200 2 3 3 10 15 DG221UGB 4 DG222UGB 4 DG223UGB
45 4
Three-Pole, Three-Wire (Three Blades)240 Vac 30 60 100 200 400 600 2 3 3 10 15 15 7-1/2 15 30 60 125 200 DG321UGB 4 DG322UGB 4 DG323UGB 4 DG324UGK 4 DG325UGK 6 DG326UGK
6
Notes 1 Maximum hp ratings apply only when dual element time delay fuses are used. 2 Use four-wire catalog numbers below. 3 Solid neutral bars are not included. Order separately from table on Page V2-T1-15. 4 WARNING! Switch is not approved for service entrance unless a neutral kit is installed. 5 Use three-wire catalog numbers below. 6 Drilled to accept field installed neutral kits. All general-duty safety switches are individually packaged. Accessories are limited in scope on general-duty safety switches. See Page V2-T1-15 for availability. In addition, clear line shields are available as an accessory on 200600A general-duty switches. Catalog Numbers: 200A = 70-7759-11, 400A = 70-8063-8, 600A = 70-8064-8.
www.eaton.com
V2-T1-27
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-28
Switching Devices
Safety Switches
Dimensions
Approximate Dimensions in Inches (mm) Plug Fuse, 120, 120/240V, Single-, Two-Pole Solid Neutral, Single-Throw
Ampere Rating 30 NEMA 1 Height 6.88 (174.8) Width 4.94 (125.5) Depth 3.44 (87.4)
6.38 (162.1) 8.69 (220.7) 9.13 (231.9) 16.00 (406.4) 23.00 (584.2) 24.00 (609.6)
10.81 (274.6) 14.38 (365.3) 19.25 (489.0) 25.50 (647.7) 45.19 (1147.8) 52.70 (1338.6)
6.88 (174.8) 7.38 (187.5) 7.38 (187.5) 11.25 (285.8) 12.63 (320.8) 14.25 (362.0)
3.75 (95.2) 4.21 (106.9) 4.23 (107.4) 6.14 (156.0) 7.27 (184.7) 8.95 (227.3)
D2 H
Notes 1 Dimensions are for estimating purposes only. 2 Figure is not applicable to plug fuse.
D2
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-30 V2-T1-30 V2-T1-31 V2-T1-40 V2-T1-41 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Features, Benefits and Functions . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches. . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. . Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Heavy-Duty
Product Description
Application Description
240 Vac Heavy-Duty, Fusible, Single-Throw 301200A Horsepower rated Suitable for service entrance use, except four-pole switches For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 600 Vac Heavy-Duty, Fusible, Single-Throw 301200A Horsepower rated Suitable for service entrance use, except 1200A on 480Y/277 or 600Y/347 grounded wye systems, per NEC 215.10 and 230.95, and four-pole switches For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 600 Vac Heavy-Duty, NonFusible, Single-Throw 301200A Horsepower rated Suitable for service entrance use, except 1200A on 480Y/277V or 600Y/347V grounded wye systems, per NEC 215.10 and 230.95, and four-pole switches For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 For heavy commercial and industrial applications where reliable performance and service continuity are critical. For the toughest heavy commercial and industrial applications, refer to Page V2-T1-77 for catalog information on our mill-duty safety switch
301200A 600 Vac, 600 Vdc maximum Horsepower rated Fusible and non-fusible switches are 100% load break and 100% load make rated The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated Suitable for service entrance applications unless otherwise noted
www.eaton.com
V2-T1-29
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-30
Switching Devices
Safety Switches
The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation
An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A
Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life
Clearly Visible Handle
Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks
Tangential Knockouts
For switches in a NEMA Type 3R, 30200A. Use a Myers type hub for all others
Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not typically provided on general-duty switches, but available as a field kit or factory installed
Cabinet door can be further padlocked at the top and bottom as applicable
UL listed File No. E5239 Meets UL 98 for enclosed switches and NEMA Std. KS-1
Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on singlethrow switches
Interlocking Mechanism
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1
NEMA 1 Enclosure Indoor Catalog Number NEMA 3R Enclosure Rainproof Catalog Number
Product Selection
DH221NRK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Two-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 30 S/N 60 100 200 400 600 800 30 60 100 200 400 600 800 1200 30 S/N 60 100 200 400 600 800 1200 30 60 100 200 400 600 H H H L H H H H H H L H H H H H H L L H H H H H H L L H H H H H H 1-1/2 1-1/2 3 7-1/2 15 1-1/2 3 7-1/2 15 1-1/2 3 7-1/2 15 3 7-1/2 15 30 50 50 1 75 1 100 1 33 7-1/2 15 3 25 3 50 3 75 3 100 3 3 7-1/2 15 25 50 75 100 3 7-1/2 15 25 50 75 100 3 7-1/2 15 25 50 75
3
3 10 15 15 3 10 15 15 3 10 15 15 10 20 30 50
5 50 5 10 20 40 50 5 10 20 40 50 5 10 20 40 50 5 10 20 40 50
DH221FGK
2 2 2
2 2 2 2
DH225FGK DH226FGK DH227FGK DH221NGK DH222NGK DH223NGK DH224NGK DH225NGK DH226NGK DH227NGK DH321FGK DH322FGK DH323FGK DH324FGK DH325FGK DH326FGK DH327FGK DH328FGK DH321NGK DH322NGK DH323NGK DH324NGK DH325NGK DH326NGK DH327NGK DH328NGK DH421FGK DH422FGK DH423FGK DH424FGK DH425FGK DH426FGK
DH225FRK DH226FRK DH221NRK DH222NRK DH223NRK DH224NRK DH225NRK DH226NRK DH227NRK DH321FRK DH322FRK DH323FRK DH324FRK DH325FRK DH326FRK DH327FRK DH328FRK DH321NRK DH322NRK DH323NRK DH324NRK DH325NRK DH326NRK DH327NRK DH328NRK
4 4 4 4 45 45
30 3 60 3 125 3 200 3 7-1/2 15 30 60 125 200 7-1/2 15 30 60 125 200 7-1/2 15 30 60 125 200
Three-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed)
Notes 1 Horsepower ratings apply only when neutral is field installed and switch is used on a grounded B phase system. 2 Use three-pole catalog numbers below. 3 Grounded B phase ratings, UL listed. 4 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 5 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-31
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-32 System Ampere Rating
Switching Devices
Safety Switches
Two-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 30 S/N 60 100 200 400 600 800 30 60 100 200 400 600 800 1200 30 S/N 60 100 200 400 600 800 1200 Four-Pole240 Vac, 250 Vdc 30 60 100 200 400 600 H H H H H H 3 7-1/2 15 30 50 3 7-1/2 15 25 50 75 10 20 30 50 7-1/2 15 30 60 125 200 5 10 20 40 50 DH421FDK 4 DH422FDK 4 DH423FDK 4 DH424FDK 4
45 45
H H H L H H H H H H L H H H H H H L L H H H H H H L L
3 10 15 15 3 10 15 15 3 10 15 15
125 1 200 1 7-1/2 2 15 2 30 2 60 2 125 2 200 2 7-1/2 15 30 60 125 200 7-1/2 15 30 60 125 200
5 50 5 10 20 40 50 5 10 20 40 50 5 10 20 40 50
3 3 3 3
DH225FPK DH226FPK DH225NPK DH226NPK DH227NPK DH325FPK DH326FPK DH327FPK DH325NPK DH326NPK
DH225FDK 4 DH226FDK 4 DH227FDK 4 DH221NDK 4 DH222NDK 4 DH223NDK 4 DH224NDK 4 DH225NDK 4 DH226NDK 4 DH227NDK 4 DH321FDK 4 DH322FDK 4 DH323FDK 4 DH324FDK 4 DH325FDK 4 DH326FDK 4 DH327FDK 4 DH328FDK 4 DH321NDK 4 DH322NDK 4 DH323NDK 4 DH324NDK 4 DH325NDK 4 DH326NDK 4
45
Three-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed)
DH328NDK 4
Notes 1 Horsepower ratings apply only when neutral is field installed and switch is used on a grounded B phase system. 2 Grounded B phase ratings, UL listed. 3 Use three-pole catalog numbers below. 4 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 5 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number NEMA 4X Enclosure CorrosionResistant, Non-Metallic Catalog Number
DH322FWK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
System
Single-Phase
Three-Phase
Single-Phase
Three-Phase
Two-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 30 S/N 60 100 200 400 600 800 30 60 100 200 400 600 800 1200 30 S/N 60 100 200 400 600 800 1200 30 60 100 200 400 600 H H H L H H H H H H L H H H H H H L L H H H H H H L L H H H H H H 1-1/2 1-1/2 3 7-1/2 15 1-1/2 3 7-1/2 15 1-1/2 3 7-1/2 15 3 7-1/2 15 30 50 50
1
3 10 15 15 3 10 15 15 3 10 15 15 10 20 30 50
125 7-1/2 2 15 2 30 2 60
2 1
5 50 5 10 20 40 50 5 10 20 40 50 5 10 20 40 50 5 10 20 40 50
3 3 4 4 4 4 4
or 4
3 3 3
5 5 5 5
75 1 100 1 32 7-1/2 2 15 2 25 75
2
200 1
Three-Wire (Two Blades, Two Fuses, S/N)240 Vac, 250 Vdc DH221NWK DH222NWK DH223NWK DH224NWK DH225NWK DH226NWK DH227NWK DH321FWK DH322FWK
4
50 2
2
125 2 200 2 7-1/2 15 30 60 125 200 7-1/2 15 30 60 125 200 7-1/2 15 30 60 125 200
5 5 5 5
Three-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed)
DH324FWK DH325FWK DH326FWK DH327FWK DH328FWK DH321NWK DH322NWK DH323NWK DH324NWK DH325NWK DH326NWK
4
6 6 6 6
DH328NWK
4 4 4 4 4 4
Notes 1 Horsepower ratings apply only when neutral is field installed and switch is used on a grounded B phase system. 2 Grounded B phase ratings, UL listed. 3 Use three-pole catalog numbers below. 4 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 5 Use four-wire catalog numbers below. 6 Refer to EnviroLine non-metallic safety switches on Page V2-T1-52. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-33
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-34 DH362NRK
Switching Devices
Safety Switches
DC 250V 600V
Two-Pole480 Vac600 Vac or Vdc 30 60 100 200 400 600 800 1200 H H H H H H L L
(Suitable for Service Entrance Use with a Neutral Kit Installed) 7-1/2 20 30 50 10 25 40 50 20 50 15 25 25 50 50 50 DH261FGK DH262FGK DH263FGK DH264FGK DH265FGK DH266FGK DH267FGK
2
DH261FRK DH262FRK DH263FRK DH264FRK DH265FRK DH266FRK DH267FRK DH361FRK DH362FRK DH363FRK DH364FRK DH365FRK DH366FRK DH367FRK DH368FRK
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361FGK DH362FGK DH363FGK DH364FGK DH365FGK DH366FGK DH367FGK DH368FGK
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361NGK DH362NGK DH363NGK DH364NGK DH365NGK DH366NGK DH367NGK DH368NGK DH361NRK DH362NRK DH363NRK DH364NRK DH365NRK DH366NRK DH367NRK DH368NRK
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 H H H H H H L 20 3 40 3 50 3 25 3 50 3 50 3 15 30 60 125 250 400 20 50 75 150 350 500 40 50 DH461FGK DH462FGK DH463FGK DH464FGK DH465FGK DH466FGK
2 4 4 4 4 24 24 24
Notes 1 DC rating for 800A switches is 250V. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 3 Ratings are for two-phase AC. 4 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4 Enclosure Watertight, Painted Steel Catalog Number
DH361NDK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Two-Pole480 Vac600 Vac or Vdc 1 (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 20 50 15 25 50 DH261FDK 2 DH262FDK 2 DH263FDK 2 DH264FDK 2 DH265FDK 2 DH266FDK 2 DH267FDK 2
3
4 4 4
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361FDK 2 DH362FDK
2
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361NDK 2 DH362NDK 2 DH363NDK 2 DH364NDK 2 DH365NDK 2 DH366NDK 2
23
DH365NPK DH366NPK
DH368NDK
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 H H H H H H L 20 5 40 5 50 5 25 5 50 5 50 5 15 30 60 125 250 400 20 50 75 150 350 500 40 50
23 23
DH463FDK 2 DH464FDK 2
23 23 23
Notes 1 DC rating for 800A switches is 250V. 2 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 3 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 4 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 4. 5 Ratings are for two-phase AC. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-35
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-36 System
Switching Devices
Safety Switches
Ampere Rating
480V
600V
480V
600V
250V
600V
Two-Pole480 Vac600 Vac or Vdc 30 60 100 200 400 600 800 1200 H H H H H H L L
(Suitable for Service Entrance Use with a Neutral Kit Installed) 7-1/2 20 30 50 10 25 40 50 20 50 15 25 50 DH261FWK
2 2 2 2 2 2
or 3 or 3 or 3 or 3
or 3 or 3
DH264FWK
2 2 2 3
or 3 or 3 or 3
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361FWK DH362FWK DH363FWK DH364FWK DH365FWK DH366FWK DH367FWK DH368FWK
4 4 4 4
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 500 20 50 75 150 350 500 500 500 DH361NWK DH362NWK DH363NWK DH364NWK DH365NWK DH366NWK
2 4 4 4 4
DH368NWK
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 H H H H H H L 20 5 40 5 50 5 25 5 50 5 50 5 15 30 60 125 250 400 20 50 75 150 350 500 40 50
2 2 2 2 2 2 2
Notes 1 DC rating for 800A switches is 250V. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 3 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 4. 4 Refer to EnviroLine Non-Metallic Safety Switches on Page V2-T1-52. 5 Ratings are for two-phase AC. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 3R Enclosure Rainproof Catalog Number
DH362UGK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Two-Pole480 Vac600 Vac or Vdc 1 (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 3 10 20 15 7-1/2 20 30 50 10 25 40 50 20 50 15 25 25 50 50 50 DH261UGK DH262UGK DH263UGK DH264UGK DH265UGK DH266UGK DH267UGK
2
DH261URK DH262URK DH263URK DH264URK DH265URK DH266URK DH267URK DH361URK DH362URK DH363URK DH364URK DH365URK DH366URK DH367URK DH368URK
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 125 200 20 50 75 125 250 400 500 500 30 60 100 150 350 500 500 500 5 10 20 40 50 DH361UGK DH362UGK DH363UGK DH364UGK DH365UGK DH366UGK DH367UGK DH368UGK
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 10 3 20
3
20 3 40
3
25 3 50
3
10 20 40 60 125 200
5 10 20 40 50
4 4 4 4 24 24 24
40 3 50 3 50 3
50 3 50 3
50 3 50 3
Notes 1 DC rating for 800A switches is 250V. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 3 Ratings are for two-phase AC. 4 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened.
www.eaton.com
V2-T1-37
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-38 System Ampere Rating
Switching Devices
Safety Switches
DC 250V 600V
480V
Two-Pole480 Vac600 Vac or Vdc 30 60 100 200 400 600 800 1200 3 10 20 15
(Suitable for Service Entrance Use with a Neutral Kit Installed) 7-1/2 20 30 50 10 25 40 50 20 50 15 25 25 50 DH261UDK 2 DH262UDK 2 DH263UDK 2 DH264UDK 2 DH265UDK 2 DH266UDK 2 DH267UDK 2
3
4 4 4
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 40 600 800 1200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 125 200 20 50 75 125 250 400 500 500 30 60 100 150 350 500 500 500 5 10 20 40 50 DH361UDK 2 DH362UDK 2 DH363UDK 2 DH364UDK 2 DH365UDK 2 DH366UDK 2 DH367UDK DH368UDK
2
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 10 5 20 5 40 5 50 5 50 5 20 5 40 5 50 5 50 5 25 5 50 5 50 5 50 5 10 20 40 60 125 200 20 50 75 125 250 400 30 60 100 150 350 500 5 10 20 40 50 DH461UDK 2 DH462UDK 2 DH463UDK 2 DH464UDK 2
23 23 23
Notes 1 DC rating for 800A switches is 250V. 2 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 3 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 4 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 3. 5 Ratings are for two-phase AC.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure CorrosionResistant, Non-Metallic Catalog Number
DH361UWK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
System
240V
480V
600V
240V
480V
600V
250V
600V
Two-Pole480 Vac600 Vac or Vdc 1 (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 3 10 20 15 7-1/2 20 30 50 10 25 40 50 20 50 15 25 25 50
2 2 2 2 2 2 2 2
or 3 or 3 or
3
2 2 2 2
or 3 or 3 or 3 or 3
or 3 or 3 or 3 or 3
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 40 600 800 1200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 125 200 20 50 75 125 250 400 500 500 30 60 100 150 350 500 500 500 5 10 20 40 50 DH361UWK DH362UWK DH363UWK DH364UWK DH365UWK DH366UWK DH367UWK DH368UWK
5 5 5 5
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 10
4
20
25
10 20 40 60 125 200
5 10 20 40 50
DH461UWK
2 2 2 2 2 2
20 4 40 4 50 4 50 4
40 4 50 4 50 4
50 4 50 4 50 4
Notes 1 DC rating for 800 ampere switches is 250V. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 3 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 2. 4 Ratings are for two-phase AC. 5 Refer to EnviroLine non-metallic safety switches on Page V2-T1-52.
www.eaton.com
V2-T1-39
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-40
Switching Devices
Safety Switches
Note Class H fuse clips supplied as standard for 30600A. Class L fuse clips supplied as standard for 8001200A. Rated at 10,000 rms symmetrical when using Class H fuses.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
Dimensions
Approximate Dimensions in Inches (mm)
Note: Dimensions are for estimating purposes only.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 1, 3R 30 60 100 200 400 600 800 1200 8.13 (206.5) 8.13 (206.5) 11.13 (282.7) 16.00 (406.4) 23.00 (584.2) 24.00 (609.6) 25.38 (644.7) 41.47 (1053.3) 15.88 (403.4) 15.88 (403.4) 21.69 (550.9) 27.63 (701.8) 45.19 (1147.8) 52.70 (1338.6) 56.69 (1439.9) 70.31 (1785.9) 10.00 (254.0) 5.25 (133.3) 10.00 (254.0) 5.25 (133.3) 10.00 (254.0) 5.25 (133.3) 11.25 (285.8) 6.14 (156.0) 12.63 (320.8) 7.27 (184.7) 14.25 (362.0) 8.95 (227.3) 14.25 (362.0) 8.95 (227.3) 19.94 (506.5) 12.44 (316.0) 16 (7.264) 16 (7.264) 22 (9.988) 46 (20.884) 110 (49.94) 135 (61.29) 158 (71.732) 430 (195.22)
NEMA 1, 3R 30 60 100 200 400 600 800 1200 8.13 (206.5) 8.13 (206.5) 11.13 (282.7) 16.00 (406.4) 23.00 (584.2) 24.00 (609.6) 25.38 (644.7) 41.47 (1053.3) 15.88 (403.4) 15.88 (403.4) 21.69 (550.9) 27.63 (701.8) 45.19 (1147.8) 52.70 (1338.6) 56.69 (1439.9) 70.31 (1785.9) 10.00 (254.0) 5.25 (133.3) 10.00 (254.0) 5.25 (133.3) 10.00 (254.0) 5.25 (133.3) 11.25 (285.8) 6.14 (156.0) 12.63 (320.8) 7.27 (184.7) 14.25 (362.0) 8.95 (227.3) 14.25 (362.0) 8.95 (227.3) 19.94 (506.5) 12.44 (316.0) 20 (9.08) 20 (9.08) 27 (12.258) 52 (23.608) 120 (54.48) 153 (69.462) 168 (76.272) 465 (211.11)
NEMA 12, 4X Stainless Steel, 4 30 60 100 200 400 600 800 1200 8.13 (206.5) 8.13 (206.5) 11.13 (282.7) 16.00 (406.4) 23.00 (584.2) 24.00 (609.6) 25.38 (644.7) 41.47 (1053.3) 12.13 (308.1) 12.13 (308.1) 24.00 (609.6) 34.38 (873.3) 57.63 (1463.8) 63.00 (1600.2) 71.75 (1822.5) 70.31 (1785.9) 10.00 (254.0) 5.50 (139.7) 10.00 (254.0) 5.50 (139.7) 10.25 (260.4) 5.50 (139.7) 11.50 (292.1) 6.44 (163.6) 12.63 (320.8) 7.19 (182.6) 14.25 (362.0) 8.88 (225.6) 14.25 (362.0) 8.88 (225.6) 19.94 (506.5) 13.51 (343.2) 17 (7.718) 17 (7.718) 28 (12.712) 55 (24.97) 125 (56.75) 167 (75.818) 175 (79.45) 475 (215.65)
NEMA 12, 4X Stainless Steel, 4 30 60 100 200 400 600 800 1200 8.13 (206.5) 8.13 (206.5) 11.13 (282.7) 16.00 (406.4) 23.00 (584.2) 24.00 (609.6) 25.38 (644.7) 41.47 (1053.3) 17.88 (454.2) 17.88 (454.2) 24.00 (609.6) 34.38 (873.3) 57.63 (1463.8) 63.00 (1600.2) 71.75 (1822.5) 70.31 (1785.9) 10.00 (254.0) 5.50 (139.7) 10.00 (254.0) 5.50 (139.7) 10.25 (260.4) 5.50 (139.7) 11.50 (292.1) 6.44 (163.6) 12.63 (320.8) 7.19 (182.6) 14.25 (362.0) 8.88 (225.6) 14.25 (362.0) 8.88 (225.6) 19.94 (506.5) 13.51 (343.2) 22 (9.988) 22 (9.988) 30 (13.62) 61 (27.694) 135 (61.29) 203 (92.162) 213 (96.702) 510 (231.54)
C L
H
C L
D2
D2
www.eaton.com
V2-T1-41
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-42 Six-Pole Motor Circuit
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . .
Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-43 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Six-Pole Switches
Product Description
Application Description
A compact safety switch thats ideal for use in heavy industry...when an in sight disconnecting means is required for two-speed motors that are remote from their motor control devices.
Trunk-type latches keep the cover tightly closed and a neoprene gasket seals out moisture and dust from the switch assembly Visible double-break quickmake, quick-break rotary blade mechanism. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Clear line shield protection Built-in fuse pullers Clearly visible handle Triple padlocking capability; cabinet door can be further padlocked at the top and bottom
Deionizing arc chutes; arc chutes confine and suppress the arcs produced by opening contacts under load For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
Product Selection
600 Vac Heavy-Duty, Fusible, Six-Pole, Single-Throw
Maximum Horsepower Ratings, Three-Phase AC (Higher Rating with Time Delay Fuses) System Ampere Rating 240V 480V 600V NEMA 12 Enclosure Industrial, Dust-Tight Catalog Number NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
600 Vac with Fuse Clips250 Vdc 30 60 100 200 400 600 800 37-1/2 7-1/215 1530 2560 515 1530 2560 50125 7-1/220 1550 3075 60150 DH661FDK 1 DH662FDK
1 2 2 2 2 2 2 2
DH663FDK 1 DH664FDK 1
2 2 2
DH661UDK
Ampere Rating
Notes 1 NEMA 12 enclosures (30800A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 3 600 Vdc rating requires that the switch be wired per the wiring diagram on the device publication. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-43
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-44
Switching Devices
Safety Switches
Heavy-Duty Double-Throw
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches Features, Benefits and Functions . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-45 V2-T1-45 V2-T1-46 V2-T1-50 V2-T1-50 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Double-Throw Switches
Product Description
Used to transfer service from a normal power source to an alternate source...or to switch from one load circuit to another.
301200A Horsepower rated 600 Vac, 250 Vdc maximum 8001200A fusible utilize common set of fuses; two Source 1 load applications Fusible or non-fusible Fusible and non-fusible switches are 100% load break and 100% load make rated Suitable for service entrance applications unless otherwise noted
The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated Approved for service entrance with neutral or ground lug kit installed Wiring configuration from factory allows a single load to be supplied by a normal or alternate source. Can be field modified to allow two loads to be alternately supplied by a single power source
40 Vac General-Duty, NonFusible, Compact Design, Double-Throw 30100A Suitable for service entrance use with neutral kit installed Non-fusible 240 Vac General-Duty, NonFusible, Double-Throw 30400A Horsepower rated Suitable for service entrance use with neutral kit installed Non-fusible Quick-make, quick-break operating mechanism
240 Vac Heavy-Duty, Fusible, Non-Fusible, Double-Throw 30800A Horsepower rated Suitable for service entrance use with neutral kit installed Fusible and non-fusible For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Ample wire bending space provides for easier installation Visible double-break quickmake, quick-break rotary blade mechanism. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Triple padlocking capability. Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks. Clearly visible handle. The position (ON or OFF) can be clearly seen from a distance
Deionizing arc chutes; arc chutes confine and suppress the arcs produced by opening contacts under load Additional locking capability; cabinet door can be further padlocked at the top and bottom Clear line shield (provided on fusible double-throw) protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield Tangential knockouts on sides, top and bottom. Enables any size of conduit to be mounted close to the wall, providing for cable installation closer to the wall and a neat appearance
UL listed switching neutral capability is available on three-pole and four-pole non-fusible double-throw switches with the installation of the proper bonding kit shown on Page V2-T1-15 Suitable for use as a manually operated switch per 2005 NEC Article 702 UL listed File No. E5239
www.eaton.com
V2-T1-45
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-46 DT224URK-NPS
Switching Devices
Safety Switches
Product Selection
240 Vac General-Duty, Non-Fusible, Compact Design, Double-Throw
Ampere Rating Main and Standby Two-Pole240 Vac 30 60 100 DT221URH DT222URH DT223URH NEMA 3R Enclosure Rainproof Catalog Number
Two-Pole, Three-Wire240 Vac250 Vdc, Solid Neutral 30 60 100 200 400 3 10 20 15 5 10 20 40 50 DT221URK-NPS DT222URK-NPS DT223URK-NPS DT224URK-NPS DT225URK-NPS
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 3R Enclosure Rainproof Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Three-Pole240 Vac250 Vdc 30 60 100 200 400 600 1 800 1200 H H H H H T L L 3 10 15 15 7-1/2 15 30 60 125 50 5 10 20 40 50 50 DT321FGK DT322FGK DT323FGK DT324FGK DT325FGK DT326FGK DT327FGK DT328FGK DT321FRK DT322FRK DT323FRK DT324FRK DT325FRK DT326FRK DT327FRK DT328FRK
DC 250V
3 10 20 15
5 10 20 40 50
3 3 3
DT224URK DT225URK
3
DT227URK DT228URK
DT327URK DT328URK
Notes 1 Only available for use with fast-acting fuses. Standard hp rating is shown. 2 Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with N suffix. 3 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. UL listed switching neutral capability is available on three-pole and four-pole non-fusible double-throw switches with the installation of the proper bonding kit shown on Page V2-T1-15. See Page V2-T1-19 for factory installation from the Flex Center.
www.eaton.com
V2-T1-47
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-48 DT363URK DT363FGK
Switching Devices
Safety Switches
Three-Pole600 Vac250 Vdc 30 60 100 200 400 600 800 1200 H H H H T T L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 20 50 75 150 350 40 50 DT361FGK DT362FGK DT363FGK DT364FGK DT365FGK DT366FGK DT367FGK DT368FGK
1 1 1 1 1 1 1 1 1 1
Two-Pole600 Vac250 Vdc 30 60 100 200 400 600 800 1200 7-1/2 20 40 50 10 25 50 50 5 10 20 40 50 50 50 50 DT261UGK DT262UGK DT263UGK DT264UGK 2 DT265UGK DT266UGK DT267UGK DT268UGK
1 1 1
Three-Pole600 Vac250 Vdc 30 60 100 200 400 600 800 800 1200 7-1/2 20 40 50 10 25 50 50 20 50 75 125 250 250 250 250 250 30 60 100 150 350 350 350 350 350 5 10 20 40 50 50 50 50 50 DT361UGK DT362UGK DT363UGK DT364UGK DT365UGK DT366UGK DT367UGK 3 DT367UGKN DT368UGK DT361URK DT362URK DT363URK DT364URK DT365URK DT366URK DT367URK 3 DT367URKN DT368URK DT361UDK 4 DT362UDK 4 DT363UDK 4 DT364UDK 4 DT365UDK 45
14 14 14 14
Notes 1 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 2 Rated 600 Vdc, 50 hp in addition to ratings shown in table. 3 Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with N suffix. 4 NEMA 12 enclosures (301200A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 5 Also available in 240 Vac catalog number DT325UDK. UL listed switching neutral capability is available on three-pole and four-pole non-fusible double-throw switches with the installation of the proper bonding kit shown on Page V2-T1-15. See Page V2-T1-19 for factory installation from the Flex Center.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
DT363URK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Four-Pole600 Vac250 Vdc 1 30 60 100 200 400 600 800 7-1/2 20 40 10 25 50 50 20 50 75 125 250 250 250 30 60 100 150 350 350 350 5 10 20 40 50 50 50
2 2 2
2 2 2 2 2 2 2
2 2 2 2 2 2 2
2 2 2
2 2 2
Notes 1 Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with N suffix. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. UL listed switching neutral capability is available on three-pole and four-pole non-fusible double-throw switches with the installation of the proper bonding kit shown on Page V2-T1-15. See Page V2-T1-19 for factory installation from the Flex Center.
www.eaton.com
V2-T1-49
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-50 Fusible Three-Pole Two Sources
Switching Devices
Safety Switches
Dimensions
Approximate Dimensions in Inches (mm) General-Duty, Non-Fusible, 240V, Two-Pole Solid Neutral, Double-Throw, Compact Design
ON OFF ON
ON OFF ON
Height (H)
Width (W)
Depth (D)
Depth (D2)
100
General-Duty, Non-Fusible, 240V, Two-Pole Solid Neutral, Double-Throw, Quick-Make, Quick-Break Design
Ampere Rating Height (H) Width (W) Depth (D) Depth (D2) Weight Lbs (kg)
ON OFF ON S/N
ON OFF ON
NEMA 3R 30 60 100 24.63 (625.6) 24.63 (625.6) 24.63 (625.6) 37.38 (949.5) 53.81 (1366.8) 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 23.13 (587.5) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 11.25 (285.8) 12.50 (317.6) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 6.10 (154.9) 8.88 (225.6) 34 (15.4) 34 (15.4 34 (15.4) 80 (36.3) 140 (63.6)
200 400
Typical General-Duty, Double-Throw Schematic Diagrams (with and without factory-installed neutral)
ON OFF S/N ON
Two Sources
C L H
ON OFF ON
D2
Notes 1 Class H fuse clips supplied as standard for 30600A. Rated at 10,000 rms symmetrical when using Class H fuses. Class H fuse clips supplied as standard for 30600A except Class T for 400A at 600V and 600A at 240V. Rated at 10,000 rms symmetrical when using Class H fuses. Table is not applicable to the compact design shown on Page V2-T1-46. The compact design is suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes. Class R fuse adapter kits are shown on Page V2-T1-15. Individual adapter kits are applicable as shown on Page V2-T1-15 and yield the short-circuit ratings per the tables above when Class R fuses are installed. When installed, Class R fuse adapter kits reject all fuses except Class R. Class J fuse provisions can be obtained on most 60400A safety switches by moving the fuse base to a new position as instructed by the device publication label. Class J fuse adapter kits, where needed, are shown on Page V2-T1-15 and yield the short-circuit ratings per the tables above when Class J fuses are installed. Class J fuse provisions must be factory installed on 30A heavy-duty switches. Catalog numbers are shown in table on Page V2-T1-19. Class J fusing is not applicable on 30200A general-duty switches, 30100A double-throw switches, 600A double-throw switches, and any switch higher than 600A. Class T fuse adapter kits are shown on Page V2-T1-15. Individual adapter kits are applicable to 200800A switches as shown on Page V2-T1-15 and yield the short-circuit ratings per the tables to the left when Class T fuses are installed. On 1200A switches, Class T fuse provisions can be obtained by moving the fuse base to a new position as instructed by the device publication label.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1
Approximate Dimensions in Inches (mm) Heavy-Duty, Non-Fusible, 240V and 600V, Three-Pole, Double-Throw
Ampere Rating Width (W) Height (H) Depth (D) Depth (D2) Weight Lbs (kg)
NEMA 1, 3R 30 60 100 200 400 600 800 1200 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 23.13 (587.5) 24.13 (612.9) 24.13 (612.9) 42.62 (1082.5) 24.63 (625.6) 24.63 (625.6) 24.63 (625.6) 37.38 (949.5) 53.81 (1366.8) 63.31 (1608.1) 63.31 (1608.1) 78.11 (1984.0) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 11.25 (285.8) 12.50 (317.5) 14.13 (358.9) 14.13 (358.9) 25.62 (650.7) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 6.10 (154.9) 7.25 (184.2) 8.88 (225.6) 8.88 (225.6) 20.47 (519.9) 34 (15.436) 34 (15.436) 34 (15.436) 80 (36.32) 140 (63.56) 175 (79.45) 175 (79.45)
D2
C L
1 1 1 1 1
H
NEMA 12, 4X Stainless Steel 30 60 100 200 400 600 800 1200 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 19.50 (495.3) 23.00 (584.2) 25.88 (657.4) 25.88 (657.4) 25.88 (657.4) 41.00 (1041.4) 57.50 (1460.5) 10.25 (260.4) 10.25 (260.4) 10.25 (260.4) 11.63 (295.4) 12.50 (317.5) 5.50 (139.7) 5.50 (139.7) 5.50 (139.7) 6.48 (164.6) 7.25 (184.2) 60 (27.24) 60 (27.24) 60 (27.24) 105 (47.67) 185 (83.99)
1 1 1
D2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 1, 3R 30 60 100 200 400 600 800 1200 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 19.56 (496.8) 25.38 (644.7) 27.44 (697.0) 28.12 (714.2) 42.62 (1082.5) 36.63 (930.4) 36.63 (930.4) 36.63 (930.4) 50.88 (1292.4) 74.75 (1898.7) 86.13 (2187.7) 58.86 (1495.0) 78.11 (1984.0) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 44 (19.976) 44 (19.976) 44 (19.976) 95 (43.13) 230 (104.42) 320 (145.28)
11.25 (285.8) 6.10 (154.9) 14.13 (358.9) 8.88 (225.6) 14.13 (358.9) 8.88 (225.6) 25.62 (650.7) 20.47 (519.9) 25.62 (650.7) 20.47 (519.9)
NEMA 12, 4X Stainless Steel, 4 30 60 100 200 400 600 800 1200 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 19.56 (496.8) 25.38 (644.7) 39.81 (1011.2) 39.81 (1011.2) 39.81 (1011.2) 55.63 (1413.0) 74.75 (1898.7) 10.25 (260.4) 5.50 (139.7) 10.25 (260.4) 5.50 (139.7) 10.25 (260.4) 5.50 (139.7) 11.63 (295.4) 6.46 (164.1) 14.13 (358.9) 8.92 (226.6) 45 (20.43) 45 (20.43) 45 (20.43) 100 (45.4) 260 (118.04)
www.eaton.com
V2-T1-51
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-52
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch Product Selection . . . . . . . . . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-53 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
Stainless steel enclosure (304 grade) Stainless steel mechanism (304 grade) 30400A Horsepower rated Suitable for service entrance use
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
\
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Product Selection
240 Vac Heavy-Duty, Fusible, Single-Throw Stainless Steel Enclosure and Operating Mechanism
Maximum Horsepower Ratings with Time Delay Fuses Ampere Rating Fuse Class Provision AC Standard Fuse Single-Phase Three-Phase Time Delay Single-Phase Three-Phase DC 250V NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
DH321NWKX
System
Three-Wire (Two Blades, Two Fuses, S/N), 240 Vac250 Vdc 30 S/N 60 100 200 400 H H H H H 1-1/2 3 7-1/2 15 3 7-1/2 15 25 50 3 10 15 15 7-1/2 15 30 60 125 5 10 20 40 50 DH221NWKX DH222NWKX DH223NWKX DH224NWKX DH225NWKX
Three-Pole, 240 Vac250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 H H H H H 1-1/2 3 15 3 7-1/2 25 50 7-1/2 15 60 125 40 50 DH321FWKX DH322FWKX
1
DH324FWKX DH325FWKX
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 30 S/N 60 100 200 400 H H H H H 3 7-1/2 15 25 50 7-1/2 15 30 60 125 20 50 DH321NWKX DH322NWKX DH323NWKX DH324NWKX DH325NWKX
Notes 1 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-53
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-54 DH31UWKX
Switching Devices
Safety Switches
600 Vac Heavy-Duty, Fusible 277/480V, Single-Throw Stainless Steel Enclosure and Operating Mechanism
Maximum Horsepower Ratings with Time Delay Fuses Ampere Rating Fuse Class Provision Single-Phase AC 480V 600V Three-Phase AC 480V 600V DC 250V 600V NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
System
Two-Pole, 480 Vac600 Vac or Vdc 2 (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 H H H H H H 7-1/2 50 10 50 15 50 50 DH261FWKX
1 1
DH264FWKX
1
DH265FWKX
Three-Pole, 480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 H H H H H H 7-1/2 20 30 50 10 25 30 50 15 30 60 125 250 250 20 50 75 150 350 350 DH361FWKX DH362FWKX DH363FWKX DH364FWKX DH365FWKX DH366FWKX
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 400 600 H H H H H H 7-1/2 20 40 50 10 25 50 50 20 50 75 125 250 250 30 60 100 150 350 350 DH361NWKX DH362NWKX DH363NWKX DH364NWKX DH365NWKX DH366NWKX
600 Vac Heavy-Duty, Non-Fusible 277/480V, Single-Throw Stainless Steel Enclosure and Operating Mechanism
Maximum Horsepower Ratings System Ampere Rating Single-Phase AC 480V 600V Three-Phase AC 480V 600V DC 250V 600V NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
Three-Pole, 480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 7-1/2 20 40 50 10 25 50 50 20 50 75 125 250 250 30 60 100 150 350 350 5 10 20 40 50 50 DH361UWKX DH362UWKX DH363UWKX DH364UWKX DH365UWKX DH366UWKX
Notes 1 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 2 DC rating for 400A switches is 250V. 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-56 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
EnviroLine/Window Switch
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
Upper Window 30800A Blade visibility when door closed 240 and 600V, fusible and non-fusible Suitable for service entrance use NEMA 12, 4 and 4X enclosures Lower Window 30600A Power plugs not supplied with the receptacle Lower viewing window over fuses to allow visual verification of blown fuse indicators for Littelfuse, Inc. fuses 240 and 600V, fusible Suitable for service entrance use NEMA 12, 4 and 4X enclosures
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
www.eaton.com
V2-T1-55
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-56 DH361UWKW
Switching Devices
Safety Switches
Product Selection
240 Vac Heavy-Duty, Fusible Single-Throw with Upper Viewing Window
Maximum Horsepower Ratings with Time Delay Fuses AC Standard Fuse Ampere Rating Fuse Class Provision SinglePhase ThreePhase Time Delay SinglePhase ThreePhase DC 250V NEMA 12 Enclosure Industrial, Dust-Tight Catalog Number NEMA 4 Enclosure Watertight, Painted Steel Catalog Number NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number
DH361UDKW
System
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 1 30 S/N 60 100 200 400 600 800 H H H H H H L 3 7-1/2 15 25 50 75 100 7-1/2 15 30 60 125 200 250 20 50 DH321NDKW 2 DH322NDKW 2 DH323NDKW 2 DH324NDKW 2 DH325NDKW 2 DH326NDKW 2 DH327NDKW 2 DH325NPKW DH326NPKW DH327NPKW DH321NWKW DH322NWKW DH323NWKW DH324NWKW DH325NWKW DH326NWKW DH327NWKW
System
Ampere Rating
480V
600V
480V
600V
DC 250V 600V
Four-Wire (Three Blades, Three Fuses, S/N), 600 Vac250 Vdc 1 30 S/N 60 100 200 400 600 800 H H H H H H L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 20 50 75 150 350 500 500 DH361NDKW 2 DH362NDKW 2 DH363NDKW 2 DH364NDKW 2 DH365NDKW 2 DH366NDKW 2 DH367NDKW 2 DH365NPKW DH366NPKW DH367NPKW DH361NWKW DH362NWKW DH363NWKW DH364NWKW DH365NWKW DH366NWKW DH367NWKW
600V
480V
600V
250V
600V
Three-Pole600 Vac, 250 Vdc 30 60 100 200 400 600 800 Notes
1 2
(Suitable for Service Entrance Use with a Neutral or Ground Lug Kit Installed) 10 25 50 50 20 50 75 125 250 400 500 30 60 100 150 350 500 500 5 10 20 40 50 DH361UDKW 2 DH362UDKW 2 DH363UDKW 2 DH364UDKW 2 DH365UDKW 2 DH366UDKW 2 DH367UDKW
2
7-1/2 20 40 50
30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers. Effective August 2003, 30100A window switches offer visible blade verification and blown fuse indication in a single design as shown in the photos.The window is replaceable. Higher ampere ratings will continue to be manufactured with a non-replaceable epoxy affixed design with visible blade verification only.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number
DH324NDKLW
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
System
Ampere Rating
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 1 30 S/N 60 100 200 400 600 H H H H H H 3 7-1/2 15 25 50 75 7-1/2 15 30 60 125 200 20 50 DH321NDKW 2 DH322NDKW 2 DH323NDKW 2 DH324NDKLW 2 DH325NDKLW 2 DH326NDKLW 2 DH325NPKLW DH326NPKLW DH321NWKW DH322NWKW DH323NWKW DH324NWKLW DH325NWKLW DH326NWKLW
System
Ampere Rating
Four-Wire (Three Blades, Three Fuses, S/N), 600 Vac250 Vdc 1 30 S/N 60 100 200 400 600 H H H H H H 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 20 50 75 150 350 500 DH361NDKW 2 DH362NDKW 2 DH363NDKW 2 DH364NDKLW
2
DH365NPKLW DH366NPKLW
DH365NDKLW 2 DH366NDKLW 2
Notes 1 For two-pole applications, use outside poles of three-pole switch. 2 NEMA 12 enclosures (30600A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. Effective August 2003, 30100A window switches are replaced by a full view window that allows blade position verification and blown fuse indication. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-57
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-58 EnviroLine/Receptacle Switch
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-59 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
EnviroLineReceptacle Switches
Product Description
These heavy-duty switches are pre-wired and interlocked to polarized receptacles for three-phase, three-wire, grounded type power plugs. Receptacles are interlocked to handle mechanisms so that power plugs may not be inserted or removed when the switch is in the ON position unless noted otherwise. Ratings are 30 100A, 600 Vac, NEMA 12/3R, 4X stainless steel enclosures.
Application Description
These are used for portable power applications such as welders, infrared ovens, batch feeders, conveyors, truck and marine docks.
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1
Product Selection
600 Vac Heavy-Duty, Single-Throw with Receptacle, Fusible, Non-Fusible
DH362FDK2WR
Safety Switch with Receptacle K-Series, Three-Pole, 600 Volt Fuse ClipsFusible
Ampere Rating Switch Receptacle Power Plug Crouse-Hinds ARKTITET Receptacle 30 60 100 30 60 100 Accepts Crouse-Hinds APJ3485 APJ6485 APJ10487 DH361FDK2WR DH362FDK2WR DH363FDK2WR DH361FWK2WR DH362FWK2WR DH363FWK2WR NEMA 12/3R Enclosure Catalog Number NEMA 4X Enclosure Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
M-R-S (Russellstoll) MAX-GARD Receptacle 30 60 100 30 60 100 Accepts Russellstoll DS3404MP DS6404MP DS1404MP DH361FD3WRK DH362FD3WRK DH363FD3WRK DH361FW3WRK DH362FW3WRK DH363FW3WRK
Appleton POWERTITE Receptacle 30 60 100 30 60 100 Accepts Appleton ACP3034BC ACP6034BC ACP1034CD DH361FD5WRK DH362FD5WRK DH363FD5WRK DH361FW5WRK DH362FW5WRK DH363FW5WRK
Safety Switch with Receptacle K-Series, Three-Pole, 600 Volt Fuse ClipsNon-Fusible
Ampere Rating Switch Receptacle Power Plug NEMA 12/3R Enclosure Catalog Number NEMA 4X Enclosure Catalog Number
Appleton POWERTITE Receptacle 30 60 30 60 Accepts Appleton ACP3034BC ACP6034BC DH361UD5WRK DH362UD5WRK DH362UW5WRK
Notes Contact the Safety Switch Flex Center (1-888-329-9272) for additional options including viewing windows and other receptacle manufacturers. Power plugs are not available through Eaton.
www.eaton.com
V2-T1-59
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-60
Switching Devices
Safety Switches
EnviroLine/Non-Metallic/Halyester
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch Product Selection . . . . . . . . . . . . . . . . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-61 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
30200A Halyester high-impact strength fiberglass reinforced polyester material Horsepower rated Suitable for service entrance use Fusible and non-fusible Opaque or transparent door
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
Product Selection
240 Vac Heavy-Duty Non-MetallicFusible 250 Volt Maximum
Maximum Horsepower Ratings Ampere Rating Fuse Class Provision AC Standard Fuse DC Single-Phase Three-Phase Single-Phase Three-Phase 250V Time Delay NEMA 4X Enclosure CorrosionResistant, Non-Metallic Opaque Cover Catalog Number Transparent Cover Catalog Number
DH361FTK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
System
Three-Pole, 240 Vac250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 H H H H 1-1/2 3 7-1/2 15 3 7-1/2 15 25 3 10 15 15 7-1/2 15 30 60 5 10 20 40 DH321FHK DH322FHK DH323FHK DH324FHK DH321FTK DH322FTK DH323FTK DH324FTK
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 30 S/N 60 100 200 H H H H 1-1/2 3 7-1/2 15 3 7-1/2 15 25 3 10 15 15 7-1/2 15 30 60 5 10 20 40 DH321NHK DH322NHK DH323NHK DH324NHK DH321NTK DH322NTK DH323NTK DH324NTK
System
Ampere Rating
Three-Pole, 240 Vac250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 H H H H 7-1/2 20 30 50 10 25 40 50 15 30 60 125 20 50 75 150 5 10 20 40 DH361FHK DH362FHK DH363FHK DH364FHK DH361FTK DH362FTK DH363FTK DH364FTK
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 30 S/N 60 100 200 H H H H 7-1/2 20 30 50 10 25 40 50 15 30 60 125 20 50 75 150 5 10 20 40 DH361NHK DH362NHK DH363NHK DH364NHK DH361NTK DH362NTK DH363NTK DH364NTK
Three-Pole, 480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 20 50 75 125 30 60 100 150 5 10 20 40 DH361UHK DH362UHK DH363UHK DH364UHK DH361UTK DH362UTK DH363UTK DH364UTK
www.eaton.com
V2-T1-61
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-62
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch Product Selection . . . . . . . . . . . . . . . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-63 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
30200A KRYDON high-impact strength fiberglass reinforced polyester material Horsepower rated Suitable for service entrance use Fusible and non-fusible
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
NEMA 4X Enclosure Corrosion-Resistant, Non-Metallic
Product Selection
240 Vac Heavy-Duty Non-Metallic Fusible
Maximum Horsepower Ratings AC System Ampere Rating Fuse Class Provision Standard Fuse Single-Phase Three-Phase Time Delay Single-Phase Three-Phase DC 250V
DH361UCK
1 1 1 1 1 1 1 1 1 1
Catalog Number
Three-Pole, 240 Vac250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 H H H H 1-1/2 3 7-1/2 15 3 7-1/2 15 25 7-1/2 15 30 60 20 40 DH321FCK DH322FCK DH323FCK DH324FCK
Four-Wire (Three Blades, Three Fuses, S/N), 240 Vac250 Vdc 30 S/N 60 100 200 H H H H 3 7-1/2 15 25 7-1/2 15 30 60 20 DH321NCK DH322NCK DH323NCK DH324NCK
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Three-Pole, 480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 H H H H 7-1/2 20 30 50 10 25 30 50 15 30 60 125 20 50 75 150 DH361FCK DH362FCK DH363FCK DH364FCK
Four-Wire (Three Blades, Three Fuses, S/N), 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 H H H H 7-1/2 20 30 50 10 25 30 50 15 30 60 125 20 50 75 150 DH361NCK DH362NCK DH363NCK DH364NCK
Three-Pole, 480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 20 50 75 125 30 60 100 150 5 10 20 40 DH361UCK DH362UCK DH363UCK DH364UCK
Note 30A heavy-duty switches with Type J fuse provisions are available from the factory only. See table on Page V2-T1-19 for catalog numbers.
www.eaton.com
V2-T1-63
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-64 DS361UX
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-65 V2-T1-65 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Features
Application Description
The cast aluminum enclosure is ideally suited for harsh industrial applications including petrochemical facilities, mining operations, pharmaceutical plants and wastewater treatment facilities.
30200A 600 Vac fusible and non-fusible See Page V2-T1-64 for information For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
Upper and lower window UL listed and NEMA approved UL 98 UL listed under Section 508 UL listed File No. E165150 and E5239
Compliances
UL Classified Standard 886 File No. E84577 Class I, Division 1 and 2, Groups B, C and D Class II, Division 1 and 2, Groups E, F and G Class III, Division 1 and 2 NEMA 7/9 Zone 1, IIB + H2 CSA Certified Standard C22.2 File No. LR 42131-6 Class I, Division 1 and 2, Groups B, C and D Class II, Division 1 and 2, Groups E, F and G Class III, Division 1 and 2 NEMA 7/9 Zone 1, IIB + H2
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
Product Selection
DS361UX
1 1 1 1 1 1 1 1 1 1
Dimensions
Approximate Dimensions in Inches (mm) NEMA 7/9 Enclosure Sizes
Catalog Number DS361FX DS362FX DS363FX DS361UX DS362UX DS363UX Standard Conduit Size 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 1.50 (38.1) 1.50 (38.1) 2.00 (50.8)
1 1 1 1 1
Outside Dimensions F 10.63 (270.0) 11.00 (279.4) 16.38 (416.1) G 15.25 (387.4) 20.50 (520.7) 25.13 (638.3) H 8.84 (224.5) 8.97 (227.8) 9.59 (243.6) Number of Outlets 2 2 2 Approximate Weight Lbs (kg) 38 (17) 57 (26) 104 (47)
NEMA 7/9 1
Enclosure Number 1 2 3 Mounting Dimensions A 5.50 (139.7) 6.00 (152.4) 10.25 (260.4) B 13.13 (333.5) 18.00 (457.2) 22.63 (574.8) J 14.13 (358.9) 19.00 (482.6) Inside Dimensions C 5.94 (150.9) 6.50 (165.1) 11.75 (298.4) D 10.75 (273.1) 16.00 (406.4) 20.00 (508.0) Dimension K 2.00 (50.8) 2.31 (58.6) 3.50 (88.9)
1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 7/930100A 2
Notes 1 Accessories and modifications shown on Pages V2-T1-17 through V2-T1-20 are NOT applicable to NEMA 7/9 disconnect switches. 2 Dual three- and four-point mounting available as standard on enclosures 1 and 2.
www.eaton.com
V2-T1-65
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-66
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches Catalog Number Selection . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-67 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
Eatons individual cable connector receptacle switches provide a convenient and safe way to quickly connect and disconnect portable equipment. The load side terminals are factory wired to individual receptacles located behind an interlocked door for added safety. The switch cannot be turned to the ON position without first closing the receptacle compartment door. A spring-loaded flap door in the receptacle compartment allows the cables to exit the compartment, but seals the compartment when the switch is not in use. For outdoor applications, this will reduce the possibility of insects building nests in the receptacle compartment.
UL listed File No. E5239 UL listed short-circuit rating of 10,000A rms symmetrical
An additional flap door on the main compartment allows for quick connection in the event that the appropriate plugs are not readily available.
Product Selection
For price and availability, contact the Switching Device Flex Center at 1-888-329-9272.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1
DT 3 6 5 N U R K
LC
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Switch Type DT = Heavy-duty double-throw DH = Heavy-duty single-throw Poles 2 = Two-pole 3 = Three-pole 4 = Four-pole
Upper Switch 1 U = Unfused F = Fusible N = Fusible with solid neutral SN = Fusible with switched neutral
Lower Switch 2 U = Unfused F = Fusible N = Fusible with solid neutral SN = Fusible with switched neutral
Receptacle Type LC = Cam-Lok LCR = Cam-Lok reverse pin LP = Posi-Lok LPR = Posi-Lok reverse pin Neutral Blank = No neutral or incl. with switch designation N = Solid neutral SN = Switched neutral
Notes 1 When upper and lower switches are the same, the switch configuration is consolidated in one letter (e.g., U not UU). Also, a switch with a neutral will have either a solid neutral or a switched neutral, not both. Lastly, a switched neutral pole is never fused. 2 This field is only used when a switch is completely non-fused.
www.eaton.com
V2-T1-67
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-68 Solar Disconnect Switch
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch Standards and Certifications. . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-69 V2-T1-69 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Features
Clear line-shield covering all live parts For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
Clear Deadfront Shield (covering all potentially live parts) Factory Installed Isolated Ground and Equipment Ground Lug Fused Center Pole (isolates fuse clips from potential back feedonly one fuse required per switch)
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1
UL 98 listed, File No. E5239 and marked suitable for NEC Article 690 applications to UL 1741
Product Selection
NEMA 3R
Ampere Rating 30 30 60 60 100 100 200 200 400 400 600 600 Catalog Number DH161NRK DH161URKN DH162NRK DH162URKN DH163NRK DH163URKN DH164NRK DH164URKN DH165NRK DH165URKN DH166NRK DH166URKN Fuse Class R R R R R R R R R R R R
1
NEMA 4X
Ampere Rating 30 30 60 60 100 100 200 200 400 400 600 600 Catalog Number DH161NWK DH161UWKN DH162NWK DH162UWKN DH163NWK DH163UWKN DH164NWK DH164UWKN DH165NWK DH165UWKN DH166NWK DH166UWKN Fuse Class R R R R R R R R R R R R
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 12
Ampere Rating 30 30 60 60 100 100 200 200 400 400 600 600 Catalog Number DH161NDK DH161UDKN DH162NDK DH162UDKN DH163NDK DH163UDKN DH164NDK DH164UDKN DH165NDK DH165UDKN DH166NDK DH166UDKN Fuse Class R R R R R R R R R R R R
www.eaton.com
V2-T1-69
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-70 Solar Combiner Boxes
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-71 V2-T1-71 V2-T1-72 V2-T1-72 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1
Features
Source Combiner Features
Poured-in-Place Gaskets for Superior Moisture Resistance White Backpan with High-Contrast Labeling for Easier, Faster Installation Suitable for Either Positive or Negative Grounded Arrays NEMA 3R or NEMA 4 PowderCoated Steel Enclosures
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Touch-Safe Midget Class Fuse Holders (non load-break) are Rated for 600 Vdc Continuous Duty
100 or 200A Input Fuse Holders (Class R) Suitable for Either Positive or Negative Grounded Arrays
1 1 1 1 1 1 1 1 1 1 1
www.eaton.com
V2-T1-71
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-72
Switching Devices
Safety Switches
Product Selection
Source Combiners
Number of Circuits 8 10 12 16 24 Maximum Fuse Size 1 30 30 30 30 20 2 Incoming Wire Range #16#4 #16#4 #16#4 #16#4 #16#4 Output Conductors 1#6 to 350 kcmil 1#6 to 350 kcmil 1#6 to 350 kcmil 2#6 to 350 kcmil 2#6 to 350 kcmil Maximum Continuous DC Current 310 310 310 400 400 2 NEMA 3R Catalog Number SC8R SC10R SC12R SC16R SC24R NEMA 4 Catalog Number SC8P SC10P SC12P SC16P SC24P
Array Combiners
Number of Circuits 6 12 6 12 Maximum Fuse Size 1 100 100 200 200 2 Incoming Wire Range #62/0 #62/0 #64/0 #64/0 Output Conductors 2#4 to 500 kcmil 4#4 to 500 kcmil 4#4 to 500 kcmil 4#4 to 500 kcmil Maximum Continuous DC Current 720 1520 1520 1520 2 NEMA 3R Catalog Number AC6100R AC12100R AC6200R AC12200R NEMA 4 Catalog Number AC6100P AC12100P AC6200P AC12200P
Dimensions
Approximate Dimensions in Inches (mm) Source Combiners
NEMA 3R Catalog Number SC8R SC10R SC12R SC16R SC24R NEMA 4 Catalog Number SC8P SC10P SC12P SC16P SC24P Dimensions Height 16.00 (406.4) 16.00 (406.4) 16.00 (406.4) 16.00 (406.4) 20.00 (508.0) Width 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 12.00 (304.8) 20.00 (508.0) Depth 6.00 (152.4) 6.00 (152.4) 6.00 (152.4) 6.00 (152.4) 6.00 (152.4) Weight in Lbs (kg) 30 (13.6) 30 (13.6) 30 (13.6) 36 (16.3) 45 (20.4)
Array Combiners
NEMA 3R Catalog Number AC6100R AC12100R AC6200R AC12200R NEMA 4 Catalog Number AC6100P AC12100P AC6200P AC12200P Dimensions Height 36.00 (914.4) 48.00 (1219.2) 42.00 (1066.8) 48.00 (1219.2) Width 36.00 (914.4) 36.00 (914.4) 36.00 (914.4) 36.00 (914.4) Depth 8.00 (203.2) 8.00 (203.2) 8.00 (203.2) 8.00 (203.2) Weight in Lbs (kg) 156 (70.8) 227 (103.0) 206 (93.5) 278 (126.2)
Notes 1 Fuses not included. 2 Total installed fuse capacity shall not exceed maximum continuous DC current rating.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-74 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
DH362NWK316
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner. . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches Product Selection . . . . . . . . . . . . . . . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Features
Stainless steel enclosure (316-Grade) 301200A Horsepower rated Suitable for service entrance use For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
www.eaton.com
V2-T1-73
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-74 S/N System
Switching Devices
Safety Switches
Product Selection
240 Vac Fusible316 Grade Stainless Steel NEMA 4X
Maximum Horsepower Ratings AC Ampere Rating Fuse Type Provision Standard Fuse Single-Phase Three-Phase Time Delay Single-Phase Three-Phase DC 250V NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
Three-Wire (Two Blades, Two Fuses, S/N)240 Vac, 250 Vdc 30 S/N 60 100 200 400 600 800 H H H H H H L 1-1/2 3 7-1/2 15 31 7-1/2 15 1 25 1 50 1 75 1 100 1
1
3 10 15 15 15
7-1/2 1 15 1 30 1 60 1 30 1 200 1
5 10 20 40 20
Three-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 1-1/2 3 7-1/2 15 3 7-1/2 15 25 50 75 100 7-1/2 15 30 60 125 200 250 20 40 50 DH321FWK316 DH322FWK316
2
Four-Wire (Three Blades, Three Fuses, S/N)240 Vac, 250 Vdc 30 60 100 200 400 600 800 1200 H H H H H H L L 3 7-1/2 15 25 50 75 100 7-1/2 15 30 60 125 200 250 20 50 DH321NWK316 DH322NWK316 DH323NWK316 DH324NWK316 DH325NWK316 DH326NWK316
2
DH328NWK316
Notes 1 Grounded B phase ratings, UL listed. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. Operating mechanism is standard plated steel. For type 304 stainless steel operating mechanism, contact the Safety Switch Flex Center (1-888-329-9272).
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
DH362NWK316
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Two-Pole480 Vac600 Vac or DC 1 (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 20 50 15 25 50 DH261FWK316
2 2
or 3 or
3
DH264FWK316
2 2 2 3
or 3 or 3 or 3
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 20 50 75 150 350 500 500 DH361FWK316 DH362FWK316 DH363FWK316 DH364FWK316 DH365FWK316 DH366FWK316 DH367FWK316 DH368FWK316
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 200 400 600 800 1200 H H H H H H L L 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 500 20 50 75 150 350 500 500 DH361NWK316 DH362NWK316 DH363NWK316 DH364NWK316 DH365NWK316 DH366NWK316
3
DH368NWK316
Notes 1 DC rating for 400800A switches is 250V. 2 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 3. 3 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
www.eaton.com
V2-T1-75
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-76 System System
Switching Devices
Safety Switches
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 200 400 600 800 1200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 125 200 20 50 75 125 250 400 500 30 60 100 150 350 500 500 5 10 20 40 50 DH361UWK316 DH361UWK316 DH363UWK316 DH364UWK316 DH365UWK316 DH366UWK316 DH367UWK316 DH368UWK316
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 200 400 600 800 10 20 40 50 50 20 40 50 50 25 50 50 50 10 20 40 60 125 200 20 50 75 125 250 400 30 60 100 150 350 500 5 10 20 40 DH461UWK316
1 1 1 1 1 1
Note 1 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73
DH361FWK-GCL
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner. . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw Product Selection . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-78 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
www.eaton.com
V2-T1-77
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-78
Switching Devices
Safety Switches
Product Selection
Fusible
Maximum Horsepower Ratings with Time Delay Fuses AC Ampere Rating Fuse Class Provision Standard Fuse SinglePhase ThreePhase Time Delay SinglePhase ThreePhase DC 250V 600V NEMA 12 Enclosure Industrial, Dust-Tight Catalog Number NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
DH361FWK-GCL
System
Three-Pole240 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 1 30 60 100 200 400 600 H H H H H H 1-1/2 3 7-1/2 15 3 7-1/2 15 25 50 75 7-1/2 15 30 60 125 200 20 40 50 DH321FDK-GCL 2 DH322FDK-GCL 2 DH323FDK-GCL 2 DH324FDK-GCL 2 DH325FDK-GCL 2 DH326FDK-GCL 2 DH321FWK-GCL DH322FWK-GCL
3
Two-Pole480 Vac600 Vac or DC 5 (Suitable for Service Entrance Use with a Neutral Kit Installed) 1 30 60 100 200 H H H H 7-1/2 20 30 50 10 25 40 50 15 25 25 50 DH261FDK-GCL 2 DH262FDK-GCL 2 DH263FDK-GCL DH264FDK-GCL
2 2
DH261FWK-GCL
3 3
or 4 or 4
DH264FWK-GCL
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 1 30 60 100 200 400 600 H H H H H H 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 400 20 50 75 150 350 500 DH361FDK-GCL 2 DH362FDK-GCL 2 DH363FDK-GCL 2 DH364FDK-GCL
2
DH365FDK-GCL 2 DH366FDK-GCL 2
Non-Fusible 277/480600V
Maximum Horsepower Ratings AC Ampere Rating Fuse Class Provision Standard Fuse SinglePhase ThreePhase Time Delay SinglePhase ThreePhase DC 250V 600V NEMA 12 Enclosure Industrial, Dust-Tight Catalog Number NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
System
Three-Pole480 Vac600 Vac, 250 Vdc 6 (Suitable for Service Entrance use with a Neutral Kit Installed) 1 30 60 100 200 400 600 7-1/2 20 40 50 10 25 50 50 20 50 75 125 250 400 30 60 100 150 350 500 5 10 20 40 50 DH361UDK-GCL 2 DH362UDK-GCL
2
Notes 1 Contact the Safety Switch Flex Center (1-888-329-9272) for copper neutrals. 2 NEMA 12 enclosures (30600A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 3 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product. 4 Use three-pole catalog numbers below for 600 Vac, 250 Vdc maximum applications. For 600 Vdc, see note 3. 5 DC rating for 400600A switches is 250V. 6 For two-pole applications, use outside poles of three-pole switch.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77
DH361FRKCB
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner. . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses Product Selection . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-80 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
30100A Horsepower rated For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
www.eaton.com
V2-T1-79
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-80
Switching Devices
Safety Switches
Product Selection
Fusible 277/480600V
Maximum Horsepower Ratings NEMA 1 Enclosure Indoor Catalog Number NEMA 3R Enclosure Rainproof Catalog Number NEMA 12 Enclosure Industrial, Dust-Tight Catalog Number NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number
DH361FRKCB
System
Ampere Rating
DC 250V
Three-Pole480 Vac600 Vac, 250 Vdc (Suitable for Service Entrance Use with a Neutral Kit Installed) 30 60 100 Cube Cube Cube 7-1/2 20 30 10 25 40 15 30 60 20 50 75 DH361FGKCB DH362FGKCB DH363FGKCB DH361FRKCB DH362FRKCB DH363FRKCB DH361FDKCB 1 DH362FDKCB
1
DH363FDKCB 1
Fusible 277/480600V
Maximum Horsepower Ratings Blades, 3-Fuses S/N 480 Vac600 Vac NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number
System
Ampere Rating
DC
Four-Wire (Three Blades, Three Fuses, S/N) 480 Vac600 Vac, 250 Vdc 30 S/N 60 100 Cube Cube Cube 7-1/2 20 30 10 25 40 15 30 60 20 50 75 DH361NGKCB DH361NRKCB DH361NDKCB 1 DH362NGKCB DH362NRKCB DH362NDKCB 1 DH363NGKCB DH363NRKCB DH363NDKCB 1 DH361NWKCB DH362NWKCB DH363NWKCB
Fusible 277/480600V
Maximum Horsepower Ratings Vac600 Vac, 250 Vac NEMA 4X Enclosure CorrosionResistant, Stainless Steel Catalog Number
System
Ampere Rating
DC
Four-Pole480 Vac600 Vac, 250 Vdc 30 60 100 Cube Cube Cube 20 40 50 25 50 50 15 30 60 20 50 75 DH461FGKCB DH462FGKCB DH463FGKCB
1 1 1 12 12 2 2 1 2
DH463FDKCB
Notes 1 NEMA 12 enclosures (30100A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. 2 Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
NEMA 4X Enclosure Corrosion-Resistant, Stainless Steel Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Four-Wire (Three Blades, Three Fuses, S/N), 600 Vac250 Vdc 1 30 S/N 60 100 Cube Cube Cube 7-1/2 20 30 10 25 40 15 30 60 20 50 75 DH361NDKWCB 1 DH362NDKWCB 1 DH363NDKWCB 1 DH361NWKWCB DH362NWKWCB DH363NWKWCB
Notes 1 NEMA 12 enclosures (30100A) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened. Fuses are supplied as separate items.
www.eaton.com
V2-T1-81
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-82 Elevator Control Switch
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch Catalog Number Selection . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-83 V2-T1-83 V2-T1-83 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
UL 98 Enclosed and Deadfront Switch Guide 96NK3917 , File No. E182262 NEMA 1, UL 50, listed enclosure cUL per Canadian Standards C22.2, No. 0-M91-CAN/CSA C22.2, No. 4-M89 Enclosed Switch
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
ES 1 T2 R2 G F1 3 N B
Control Transformer 1 T2 = 208V T3 = 240V T1 = 480V T4 = 600V Fire Safety Interface Relay (3PDT, 10A, 120V) R2 = 24 Vdc coil R1 = 120 Vac coil
Fire Alarm Voltage Monitoring Relay (To Monitor Shunt Trip Voltage) F1 = Single-pole F3 = Three-pole
Enclosure Options (NEMA 1 Standard With No Suffix Designation Required) 3= NEMA 3R D= NEMA 12 P= NEMA 4 painted steel
100A S.T. switch 480V-3PES3 480120V CPTT1 120 Vac coil fire safety interface relayR1 Pilot lightON (Green)G Fire alarm voltage monitoring relay (three-pole)F3
1 1 1 1 1 1 1 1 1 1 1 1 1 1
Dimensions
Approximate Dimensions in Inches (mm) Elevator Control Switch Dimensions and Lug Data
Ampere Rating 30 60 100 200 400 NEMA 1 1 Height 20.00 (508.0) 20.00 (508.0) 20.00 (508.0) 30.00 (762.0) 52.00 (320.8) Width 16.00 (406.4) 16.00 (406.4) 16.00 (406.4) 20.00 (508.0) 25.00 (635.0) Depth 8.63 (219.2) 8.63 (219.2) 8.63 (219.2) 8.63 (219.2) 8.00 (203.2) NEMA 3R, 12 2 Height 20.00 (508.0) 20.00 (508.0) 20.00 (508.0) 30.00 (762.0) Width 20.00 (508.0) 20.00 (508.0) 20.00 (508.0) 24.00 (609.6) Depth 8.00 (203.2) 8.00 (203.2) 8.00 (203.2) 8.00 (203.2) 8.00 (203.2) Lug Size 3 #14#8 Al or Cu #14#2 Al or Cu #81/0 Al or Cu #6250 kcmil Al or Cu (2) I/O(1) 750 Catalog Number ES1 ES2 ES3 ES4 ES5
Notes 1 Standard oversize enclosure to mount control power transformer fire safety interface relay and control terminal blocks. 2 Contact factory for dimensions for NEMA 4 enclosure. 3 Optional neutral lug size same as line and load.
www.eaton.com
V2-T1-83
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-84 DH323FRKA1240
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-85 V2-T1-87 V2-T1-88 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch Product Selection . . . . . . . . . . . . . . . . . . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
Features
30200A Horsepower rated NEMA 3R outdoor enclosure standard 15A ground fault receptacle standard For factory modifications, refer to Pages V2-T1-17 through V2-T1-20
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1
Product Selection
Non-Fusible 208 Vac240 Vac480 Vac600 VacThree-Pole
Maximum Horsepower Ratings Ampere Rating 208 Vac 30 60 100 200 240 Vac 30 60 100 200 480 Vac 30 60 100 200 600 Vac 30 60 100 200 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 20 50 75 125 30 60 100 150 DH361URKA1600 DH362URKA1600 DH363URKA1600 DH364URKA1600 3 10 20 15 7-1/2 20 40 50 10 25 50 50 10 20 40 60 20 50 75 125 30 60 100 150 DH361URKA1480 DH362URKA1480 DH363URKA1480 DH364URKA1480 3 10 20 15 10 20 40 60 DH321URKA1240 DH322URKA1240 DH323URKA1240 DH324URKA1240 DH321URKA1208 DH322URKA1208 DH323URKA1208 DH324URKA1208 Single-Phase AC 240V 480V 600V Three-Phase AC 240V 480V 600V Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1
DH323FRKA1240
1 1 1 1 1 1 1 1 1 1 1 1 1
Note Contact the Safety Switch Flex Center (1-888-329-9272) for additional options, including 20A GFI receptacles.
www.eaton.com
V2-T1-85
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-86 Ampere Rating 480 Vac 30 60 100 200 600 Vac 30 60 100 200 H H H H H H H H Fuse Type Provision
Switching Devices
Safety Switches
7-1/2 20 30 50
10 25 40 50
15 30 60 125
20 50 75 150
7-1/2 20 30 50
10 25 40 50
15 30 60 125
20 50 75 150
Note Contact the Safety Switch Flex Center (1-888-329-9272) for additional options, including 20A GFI receptacles.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
www.eaton.com
V2-T1-87
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-88
Switching Devices
Safety Switches
Contents
Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch. . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch. . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . .
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-90 V2-T1-91 V2-T1-91 V2-T1-91 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-103
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches. . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. . Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch Catalog Number Selection . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Reference Information . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
QA Type Switch
Features
480V UL 600V CSA 8004000 Amperes 50006000 Amperes (not UL listed) 200 kAIC and 100% rated with Class L fuses Top or bottom feed Two, three- or four-pole Optional blown fuse detection and protection
Quick-positive switching action Manual or electrically operated mechanism 6X Make/12X Break contact rating Pringle Flex Center can offer custom assemblies; for quotes, call 1-888-3299272 option 2 Many options available, see following page
Should any pair of washers become inoperable for any reason, the entire spring assembly will still be operable by means of the remaining pairs. This is unlike the situation if a coil spring were to fracture or fatigue.
1 1 1 1 1 1 1 1
Spring Mechanism All quick action switches use a unique spring mechanism for improved reliability over traditional coil springs. The unique spring design is created by a series of concave-convex washers. The paired-washer spring design provides a higher force/distance ratio, making it easier to operate the mechanism.
1 1 1 1 1
www.eaton.com
V2-T1-89
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-90 Switch PMS = Pringle Mill Switch 08 12 16 20 25 30 40 50 60 Switch CB = CBC QA = QA FP = FP EO = EO 1 Amperes = 800A = 1200A = 1600A = 2000A = 2500A = 3000A = 4000A = 5000A 8 = 6000A 8
Switching Devices
Safety Switches
CB 08 3 3 B 120 480 K G P AO CT 5
NF
Additional Option
Poles 2 = Two-pole 3 = Three-pole 4 = Four-pole Wire 2 = Two-wire 3 = Three-wire 4 = Four-wire Feed B = Bottom T = Top Voltage Control 2 120 = 120V 3
Control Power Transformer 2 CT = With control power transformer 6 System Voltage 4 208 = 208V 5 480 = 480V 600 = 600V Interlock K = Key interlock provisions Blown Fuse Detector (BFD) A = BFD with three normally ON lights (does NOT trip) AO = BFD with three normally OFF lights (does NOT trip) AX = BFD with NO lights (trips switch) A9 = BFD with three normally ON lights (trips switch) AR = BFD with three normally OFF lights (trips switch) Phase Failure Relay 2 R = Single-phase voltage relay with capacitor trip device (SPVR)
NF = Non-fused 7 Options 6 = With handle suitable to meet 66 requirements Auxiliary Contact 6 = 1NO/1NC 7 = 2NO/2NC
Ground Fault 2 = Ground fault with control power transformer GNX = Ground fault without control power transformer G
PMS 08 3 3 NF T B W
Option 9 W = With viewing window Poles Amperes 08 = 800A 12 = 1200A 16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A 40 = 4000A 2 = Two-pole j 3 = Three-pole k Wire 2 = Two-wire j 3 = Three-wire k Fusing F = Fusible NF = Non-fusible Feed Entry B = Bottom T = Top Feed Exit B = Bottom T = Top
Notes 1 Not UL listed. A separate control box may be required when adding accessories. 2 Not an option with QA type switches. GF option includes control power transformer. 3 110 Vdc and 125 Vdc also available. Please contact the Cleveland, TN plant. 4 For different system voltage requirements, please contact the Cleveland, TN plant. 5 For QA switches, use 480V system catalog number when referencing a 208V system. 6 Only applicable if ordering a CPT only, without ground fault. 7 Only available with QA switches and in a top-feed configuration. 8 Does not carry UL listing. 9 Additional available accessories/optionsdoor interlock, special nameplates, custom dimensions, special paint and auxiliary contacts. Please inquire with the Cleveland, TN plant. j 250 Vdc. k 480 Vac.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Product Selection
Manually Operated (QA) UL Listed Manually operated contact switch with quick positive switching action. Can be top or bottom fed. Electrical Trip (CBC)UL Listed Contact switch with chargebefore-close mechanism. Can be manually or electrically tripped. Optional blown fuse detector and phase failure relay with capacitor trip available. Fault Protector Electrical Trip (FP)UL Listed The FP combines the features of a CBC switch but includes an integrated zero-sequence sensor and ground fault. Electrically Operated Electric Trip (EO)Not UL Listed The EO combines the features of a CBC switch, but includes an operator with a linear motor that electrically closes the switch while charging the stored energy mechanism for stored energy trip. Pringle Mill Switch (PMS) Not UL Listed Manually operated contact switch with quick-positive switching action. Comes in a NEMA 1/3R/12 enclosure with a side-operated mechanism. Can be fusible or non-fusible, two- or threepole configurations. Service Eatons Pringle switches have always been manufactured with precisionmade parts, and, like any mechanical device, they do require routine maintenance in order to operate at the optimal level. Over time, contact surfaces may be exposed to dirt and other contaminants, which could result in improper mechanical and/or electrical operation of the switch. Eaton maintains a dedicated service team that has over 100 years of combined experience in the exclusive service and repair of Pringle switches. A service call performed by a certified technician ensures that your equipment is cleaned, lubed, adjusted and repaired, and a one-year extended warranty is granted. General maintenance, repair/ refurbishment and troubleshooting are just some of the services provided. In-House Service Eaton also offers in-house inspection, service and repair at our manufacturing facility in Cleveland, TN. Aftermarket Parts Eaton has a full line of factoryspecified aftermarket parts for Pringle switches, as well as complete, form, fit, function, drop-in replacement switches. Aftermarket part information can be found in publication TD00808001E. Flex Custom Capabilities Custom solutions are standard throughout Eatons switching device product line and bolted pressure contact switches are no exception. When a standard product will not meet the customers need, Eatons engineering and marketing teams can develop and offer solutions built to the customers expectation. Engineered-to-Order, or Flex, Non-Load-Break switch solutions with bolted pressure contact technology vary as noted below.
Reference Information
For service questions, or to schedule service: 1.888.329.9272, option 2 pringle@eaton.com For aftermarket replacement parts: 1.877.ETN.CARE, option 2, option 1, 1.877.386.2273, option 2, option 1, TRC@eaton.com for existing in the field. Product brochures available via Eaton.com
Pringle Product Brochure BR00808001E Pringle Mill Switch PA00808001E Pringle Replacement Parts GuideTD00808001E Pringle Service DM00808002E
8004000A 5000 and 6000A available (not UL listed) 200 kAIC and 100% rated with Class L fuses
Motor operated: 800 to 6000A High current: 6000 to 35,000A+ Medium voltage: 5 kV, 15 kV+ DC voltages: 250 Vdc to 3000 Vdc+ Transit applications: single-, two-or three-pole DC rated Manual transfer switches Live front switches
www.eaton.com
V2-T1-91
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-92
Switching Devices
Safety Switches
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Options and Accessories . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . .
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-93 V2-T1-93 V2-T1-94 V2-T1-95 V2-T1-99 V2-T1-103
Application Description
Maximum switch-fuse application based on shortcircuit current withstand (symmetrical amperes). Short-Circuit Ratings
Switch Rating Amperes 30 60 100 400 600 Maximum Application at 240, 480 or 600 Vac Class R Fuses 200,000 200,000 200,000 Current Limiting Fuse Class J 200,000 200,000 200,000
Reference Information
Technical data: 29-420 Dimensions and drilling plans: DS 29-470 30, 60, 100A instruction leaflet: I.L. 14857C 30, 60, 100A auxiliary switch instruction leaflet: I.L. 14471C 200A instruction leaflet: I.L. 15014A 200A auxiliary switch instruction leaflet: I.L. 14486A Handle mechanisms: TD 29-520
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Product Selection
DS Type Switch Switch Ordering Information
Switch Rating 30 30 30 30 30 60 60 60 60 100 Fuse Clip Rating Ampere No fuse 4 30 30 60 60 No fuse 4 60 60 100 No fuse 4 Type Volts 1 NEC 250 NEC 600 NEC 250 NEC 600 NEC 250 NEC 600 NEC 250/600 Catalog Number 23 DS16U DS121R DS161R DS122 DS162 DS26U DS222R DS262R DS263 DS36U
Notes 1 600V ratings are suitable for Class J fuses. 2 Switches with Catalog Number Suffix R are UL listed for use with Class R fuses when fuse clip conversion kits shown on this page are used. 3 Switches with Catalog Number Suffix R or U are CSA listed. 4 Rated 600V. 5 Supplied as unfused switch with separate fuse blocks. 6 Not listed with Underwriters Laboratories.
www.eaton.com
V2-T1-93
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-94
Switching Devices
Safety Switches
Maximum Horsepower
Maximum Horsepower Ratings Type Switch DS16U DS121R DS122 DS161R DS162 DS26U DS222R DS262R DS263 DS36U DS363R DS364 DS56U DS565R DS66U DS666R 120 Vac Standard 5 1-1/2 3 10 3 15 Time Delay 3 7-1/2 240 Vac Standard 10 3 7-1/2 20 7-1/2 15 30 15 25 100 50 100 75 Time Delay 7-1/2 15 30 100 100 480 Vac Standard 20 5 15 40 15 25 75 25 50 250 100 400 150 Time Delay 15 30 60 250 400 600 Vac Standard 25 7-1/2 15 60 15 30 75 30 60 350 125 500 200 Time Delay 20 50 75 350 500 250 Vdc 7-1/2 5 5 5 5 15 10 10 10 25 20 20
Terminal Data
Wire Range Switch Rating 30 60 100 400 600 Copper #14#2 #14#2 #141/0 (1) #4600 kcmil or (2) 1/03/0 Same as 400A except two terminals per pole Aluminum #12#2 #12#2 #121/0 (1) #4600 kcmil or (2) 1/0250 kcmil
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-96 V2-T1-97 V2-T1-98 V2-T1-99 V2-T1-103
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches. . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. . Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . . Type Visi-Flex DE-ION Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Options and Accessories . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Reference Information
UL 98
Technical data: 29-420 Dimension sheet: 29-470 30, Special 60A Model A drilling instructions: I.L. 15051 60, 100A Model A drilling instructions: I.L. 15052A 30, Special 60, 100A Model A and T auxiliary switch: I.L. 12641C 60, 100A Model A and T fuse kit: I.S. 12565C No fuse kit cover mounting: I.S. 12942B Fuse clip kits for Class R (1226C94G01-G05): I.L. 15491 Fuse clip kits for Class R (1226C94G06-G11): I.L. 15492 200 ampere instruction leaflet: I.L. 12505
1 1 1 1 1 1 1 1 1 1 1 1 1
www.eaton.com
V2-T1-95
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-96 100 60 7 Model T
Switching Devices
Safety Switches
Product Selection
Switch Ordering Information
Model A, Adjustable Depth Fuse or No-Fuse Kit (see photos on Page V2-T197) No fuse 6 30A/250V 60A/250V 100A/250V 30A/600V 60A/600V Special 60 7 No fuse 6 30A/250V 60A/250V 100A/250V 30A/600V 60A/600V No fuse 6 30A/250V 60A/250V 100A/250V 200A/250V 30A/600V 60A/600V 100A/600V No fuse 6 60A/250V 100A/250V 20A/250V 60A/600V 100A/600V 200A/600V Complete Unit Catalog Number 1 2607D89G01 2607D89G02 2607D89G03 2607D89G04 2607D89G05 2607D89G06 2607D89G07 2607D89G08 2607D89G09 2607D89G10 2607D89G11 2607D89G12 2607D90G01 2607D90G02 2607D90G03 2607D90G04 2607D90G05 2607D90G06 2607D90G07 2607D90G08 2607D91G07 2607D91G08 2607D91G09 2607D91G10 2607D91G11 2607D91G12 2607D91G13 Switch Only 2 Catalog Number (see handle and shaft below, fuse kit at right) 2607D63G02 2607D63G01 2607D63G01 2607D63G01 2607D63G01 2607D63G01 2607D63G06 2607D63G05 2607D63G05 2607D63G05 2607D63G05 2607D63G05 2607D66G14 2607D66G13 2607D66G13 2607D66G13 2607D66G13 2607D66G13 2607D66G13 2607D66G13 2607D66G18 2607D66G17 2607D66G17 2607D66G17 2607D66G17 2607D66G17 2607D66G17 Model T, Toggle Operated Switch Only 3 Catalog Number (see fuse kit at right) 371D392G02 371D392G01 371D392G01 371D392G01 371D392G01 371D392G01 371D392G06 371D392G05 371D392G05 371D392G05 371D392G05 371D392G05 657D780G12 657D780G11 657D780G11 657D780G11 657D780G11 657D780G11 657D780G11 657D780G11 657D780G16 657D780G15 657D780G15 657D780G15 657D780G15 Fuse Clip Kits for Model A or T NEC and Standard Time Delay 45 (No-Fuse KitSee Below)
Model A
Clips for Class K or H Fuses Catalog Number 313C590G08 313C590G09 313C590G13 313C590G10 313C590G11 313C590G08 313C590G09 313C590G13 313C590G10 313C590G11 177C880G23 177C880G12 177C880G13 177C880G14 177C880G24 177C880G15 177C880G16 177C880G12 177C880G13 177C880G14 177C880G15 177C880G16 177C880G18
Clips for Class R Fuses Only Catalog Number 1226C94G01 1226C94G03 1226C94G05 1226C94G02 1226C94G04 1226C94G01 1226C94G03 1226C94G05 1226C94G02 1226C94G04 1226C94G06 1226C94G08 1226C94G10 1226C94G07 1226C94G09 1226C94G11 1226C94G08 1226C94G10 1226C94G09 1226C94G11
Notes 1 Model A shipped as basic switch, operating handle, shaft and fuse or no-fuse kit. Model T shipped as basic switch and fuse or no-fuse kit. 2 External operating handle, shaft and fuse or no-fuse kit required. 3 Fuse or no-fuse kit required. 4 Includes fuse clips and Micarta barriers. 5 Will also accept non-rejection type current limiting fuses: BussmannT: 1560A type KTN and KTS (ferrule type), 65200A type KTN and KTS (blade type) Chase Shawmut: 1560A type 1 (ferrule type), 65200A type 3 (blade type) Federal Pacific Electric: 15200A types NCL and SCL 6 Rated 600V. 7 Special 60A switch has same dimension as 30A Visi-Flex switch. Standard 60A switch has same dimension as 100A Visi-Flex switch.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Special Switches and Fuse Clips Visi-Flex Switches with Auxiliary Switch Internally Mounted
Note: Basic switch only. Also order no-fuse kit, fuse kit, operating handle and shaft as required.
Ampere Rating Model A 30 Special 60 60 100 Model T 30 Special 60 60 100 371D392G04 371D392G08 657D780G14 657D780G18 371D392G03 371D392G07 657D780G13 657D780G17 2607D63G04 2607D63G08 2607D66G16 2607D66G20 2607D63G03 2607D63G07 2607D66G15 2607D66G19 Catalog Number (for use without fuses) Catalog Number (for use with fuses)
No Fuse Kit
Notes 1 For use with panels 5.068.19 inches (128.5208.0 mm) deep. 2 For use with panels 5.199.97 inches (131.8253.2 mm) deep. 3 Order Instruction Sheet 12641. 4 For panel depth of 8.199.94 inches (208.0252.5 mm), a minimum of 1.75 inch must be cut from bottom of shaft.
For Use With 30 and special 60A switch 60 and 100A switch
www.eaton.com
V2-T1-97
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-98
Switching Devices
Safety Switches
60A Switch (and Special 60 Ampere Switch) Unfused 30A/250V 60A/250V 100A/250V 200A/250V 1 30A/600V 60A/600V 100A/600V 1 100A Switch Unfused 30A/250V 60A/250V 100A/250V 200A/250V 30A/600V 60A/600V 100A/600V 200A/600V 15 1-1/2 3 15 15 3 7-1/2 15 15 30 3 7-1/2 15 15 7-1/2 15 30 30 60 5 15 25 25 15 30 60 60 75 7-1/2 15 30 30 20 50 75 75 20 5 10 20 20 7-1/2 1-1/2 3 3 7-1/2 20 3 7-1/2 15 15 15 7-1/2 15 40 5 15 25 15 30 30 50 7-1/2 15 30 20 50 50 10 5 10 10 5 10 10
Note 1 Does not apply to special 60A switch since these fuse clips cannot be added.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-100 V2-T1-101 V2-T1-102 V2-T1-103
Contents
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches. . . . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . . . . EnviroLineReceptacle Switches . . . . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . . . . NEMA 7/9Hazardous Location Disconnect Switch. . Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty Fusible Safety Switches Accepting Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . . Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flange MountedFixed Depth . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
www.eaton.com
V2-T1-99
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-100 C361H1 100 60
Switching Devices
Safety Switches
Product Selection
Operating Mechanism Variable Depth with Disconnect SwitchRight-Hand Mounting
Maximum Horsepower Ratings 2 Variable Depth Mtg. Range Min./Max. (Inches) 1 7 to 16 AC System Volts (Motor Volts) 208 (200) 7-1/2 240 (230) 7-1/2 Fuse Clip Rating (Amperes) Noninterchangeable Type for Class H, J, K or R Type Fuses Only 250V 600V Switch and Operating Mechanism Only DOES NOT Include Handle Catalog Number C361NC C361SC21 C361SC61 C361ND C361SD22 C361SD62 C361NE C361SE263 C361NF1 C361SF264 Switch and Operating Mechanism with 4-Inch Handle 3 For NEMA 1 or 12 Enclosure Catalog Number C361NC1 C361SC121 4 C361SC161 C361ND1 C361SD122 4 C361SD162 C361NE1 C361SE1263 C361NF1 C361SF1264
4 4
C361NE1
For NEMA 4 Enclosure Catalog Number C361NC2 C361SC221 4 C361SC261 4 C361ND2 C361SD222 4 C361SD262 4 C361NE2 C361SE2263 C361NF2 C361SF2264
15
Non-fusible 30 60 30
7 to 16
15
15
30
50
10
Non-fusible 60 30 60
7 to 16
25
30
60
75
20
200
7 to 16
40
60
125
150
40
Handle Only
Application For use with 30, 60 100 and 200A disconnect switches Operating Handle Length in Inches (mm) 4.00 (101.6) 4.00 (101.6) 6.00 (152.4) 6.00 (152.4) NEMA Type Enclosure 1-12 4 1-12 4 Catalog Number C361H1 C361H2 C361H3 C361H4
Notes 1 Dimension shown is from panel to flange surface. 2 Refers to rating of switch only. 3 Components individually boxed and shipped in overpack carton. 4 For rejection clips, add Suffix Letter R to listed Catalog Number. Example: C361SC121R.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Accessories
Type C361 NEMA 12 Safety Door Hardware Type C361 door hardware kits unauthorized entry. are designed to function with These kits can be used all C361 and C371 disconnect on enclosure flanges with switches and circuit breaker material thickness ranging operating mechanisms. from 16 gauge through 3/16 inches with flanges These kits are designed for on the right side only. Door use with small enclosures hardware kits are to be up to 40 inches (1016 mm), installed in a commercially intermediate 4060 inches available enclosure. Consult (10161524 mm) or larger the enclosure manufacturer floor cases over 60 inches application data for proper (1524 mm) to provide kit selection. enclosure sealing and protection against Interlocks and Connecting Rod Electrical Interlocks
Circuit 1NO-1NC 2NO-2NC Catalog Number DS200EK1 DS200EK2
Notes 1 The 1/4-inch x 1/2-inch standard mill rectangular locking bar is not supplied with these kits. 2 Third roller latch for use with 4 or 6-inch handle when three-point latching is required.
www.eaton.com
V2-T1-101
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-102
Switching Devices
Safety Switches
Dimensions
Approximate Dimensions in Inches (mm) Mounting Dimension Requirements in Inches (mm)
Disconnect Switch Type 30A and 60A non-fusible 30A and 60A fusible 100A non-fusible 100A fusible 200A non-fusible and fusible A See dimensions below B See dimensions below C 1.56 (39.6) 1.56 (39.6) 1.75 (44.5) 1.75 (44.5) 3.34 (84.8) D 0.96 (24.4) 0.96 (24.4) 1.10 (27.9) 1.10 (27.9) 0.63 (16.0) E 4.00 (101.6) 4.00 (101.6) 5.50 (139.7) 5.50 (139.7) 8.50 (215.9) F 3.50 (88.9) 3.50 (88.9) 3.38 (85.9) 3.38 (85.9) 1.84 (46.7) G 7.12 (180.8) 9.75 (247.7) 7.12 (180.8) 11.88 (301.8) 15.50 (393.7)
Dimension A = The required wire bending spacing selected from Article 430.10 of the National Electrical Code. Dimension B = Minimum or maximum depth from inside of flange holding operating handle to panel where disconnect switch is mounted (variable 7 to 16 inches).
CA08100003EMay 2012
www.eaton.com
Switching Devices
Safety Switches
1.1
Page V2-T1-2 V2-T1-24 V2-T1-29 V2-T1-42 V2-T1-44 V2-T1-52 V2-T1-55 V2-T1-58 V2-T1-60 V2-T1-62 V2-T1-64 V2-T1-66 V2-T1-68 V2-T1-70 V2-T1-73 V2-T1-77 V2-T1-79 V2-T1-82 V2-T1-84 V2-T1-87 V2-T1-88 V2-T1-89 V2-T1-92 V2-T1-95 V2-T1-99 V2-T1-104 V2-T1-104
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy-Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-Pole Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . EnviroLineStainless Steel Switch . . . . . . . . . . . . EnviroLineUpper and Lower Window Switches . EnviroLineReceptacle Switches . . . . . . . . . . . . . EnviroLineNon-Metallic Halyester Switch . . . . . . EnviroLineNon-Metallic KRYDON Switch . . . . . . NEMA 7/9Hazardous Location Disconnect Switch Quick Connect Switches . . . . . . . . . . . . . . . . . . . . Solar Disconnect Switch. . . . . . . . . . . . . . . . . . . . . Solar Combiner BoxSource Combiner and Array Combiner . . . . . . . . . . . . . . . . . . . . . . . . . . 316-Grade Stainless Steel Safety Switches . . . . . . Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible, Single-Throw. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy-Duty Fusible Safety Switches Accepting Cube Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Elevator Control Switch . . . . . . . . . . . . . . . . . . . . . . Auxiliary Power Heavy-Duty Safety Switch . . . . . . Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . 200% Neutral Safety Switches . . . . . . . . . . . . . . . Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . Type Visi-Flex DE-ION. . . . . . . . . . . . . . . . . . . . . . . Flange MountedVariable Depth . . . . . . . . . . . . . Flange MountedFixed Depth Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . .
Product Selection
Fixed Depth Application
AC System Volts (Motor Volts) 208 (200) 7-1/2 240 (230) 7-1/2 480 (460) 15 600 (575) 20
www.eaton.com
V2-T1-103
1.1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-104
0.38 (9.7) Dia. Holes for Panel Support if Necessary
Switching Devices
Safety Switches
Accessories
Electrical Interlocks
Circuit 1NO-1NC 2NO-2NC Catalog Number DS200EK1 DS200EK2
Dimensions
Approximate Dimensions in Inches (mm) Frame Size
Description 3060A disconnect switch 150A circuit breaker 100A disconnect switch 250A circuit breaker 400A circuit breaker A B C D E 8.63 (219.2) 11.38 (289.1) 8.63 (219.2) 11.38 (289.1) 9.88 (251.0) 13.38 (339.9) 9.88 (251.0) 13.38 (339.9) 9.88 (251.0) 13.38 (339.9) 6.50 (165.1) 1.50 (38.1) 9.50 (241.3) 6.50 (165.1) 1.50 (38.1) 9.50 (241.3) 7.00 (177.8) 1.25 (31.8) 11.75 (298.5) 7.00 (177.8) 1.25 (31.8) 11.75 (298.5) 7.00 (177.8) 1.25 (31.8) 11.75 (298.5)
Approximate Dimensions
0.38 (9.7) 0.31 (7.9)
Notes 1 Refers to rating of switch only. 2 For Rejection Clips, add Suffix Letter R to listed Catalog Number. Example: C361FSC121R.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
Page V2-T1-106 V2-T1-106 V2-T1-107 V2-T1-109 V2-T1-111 V2-T1-113 V2-T1-114 V2-T1-116
Contents
Description Features, Benefits and Functions . . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . . Cross-Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flex Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1
Product Description
Application Description
NEMA 1 General Purpose
Surface or Flush Mounting 151200A, 600 Vac, 500 Vdc NEMA 1 enclosed breakers are designed for indoor use in commercial buildings, apartment buildings and other areas where a general purpose enclosure is applicable. The breaker is front operable and is capable of being padlocked in the OFF position. Ratings through 1200A are listed with Underwriters Laboratories as suitable for service entrance application. Both surface and flush mounted enclosures are available.
1
NEMA 3R Rainproof Surface Mounting
Interchangeable Hubs (through 400A) 151200A, 600 Vac, 500 Vdc This general purpose outdoor service center employs a circuit breaker inside a weatherproof sheet steel enclosure to serve as a main disconnect and protective device for feeder circuits. The operating handle can be padlocked in the OFF position, and is interlocked to prevent the door from opening when the breaker is ON. Ratings through 1200A are listed by Underwriters Laboratories as suitable for service entrance application.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1
NEMA 4/4X Water and Dustproof
www.eaton.com
V2-T1-105
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-106
Switching Devices
Enclosed Circuit Breakers
Side-opening door on NEMA 3R enclosures Padlockable in the OFF position Surface or flush mounted enclosures available through 400A on NEMA 1 enclosures Interlocked handle on NEMA 3R, 4/4X, 5 and 12 enclosures to prevent opening when the breaker is in the ON position Interchangeable hubs Numerous factory options
NEMA 1 General Purpose UL File No. E7819 CSA File No. LR84319 NEMA 3R Rainproof Surface Mounting UL File No. E7819 CSA File No. LR84319 NEMA 4/4X, 5 Water and Dustproof UL File No. E7819 CSA File No. LR84319 NEMA 12 Dustproof Surface Mounting UL File No. E7819 CSA File No. LR84319 NEMA 7/9 Hazardous Location UL File No. E84577 CSA File No. LR42131-6
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1 1 1
Breaker TED134100WL TED134100WL TED134100WL TED134100WL TED134100WL TED134100WL TED134150WL TED134150WL TED134150WL TFJ236225WL TFJ236225WL TFJ236225WL TFJ236225WL TFJ236225WL TFJ236225WL
Cross-Reference
Enclosed Circuit Breaker Competitive Catalog Numbers
Catalog Number NEMA Rating 1 surface 1 flush 3R 12 12K 4/4X 1 surface 1 flush 3R 12/3R 12 12K 4/4X 7/9 9 7/9 9 1 surface 1 flush 3R 12 12K 4/4X 7/9 1 surface 1 flush 3R 12 12K 4/4X 7/9 1 surface 1 flush 3R 12/3R 12 12K 4/4X 7/9 9 Eaton Enclosure SGDN100 RGDN100 JGDN100 DGDN100 WGDN100 SFDN100 FFDN100 RFDN100 JFDN100 DFDN100 WFDN100 XFDN050 XFDN225B 1 SFDN225 1 FFDN225 1 RFDN225 1 JFDN225 1 DFDN225
1
Square D Breaker GHC3100 GHC3100 GHC3100 GHC3100 GHC3100 EHD3100L EHD3100L EHD3100L EHD3100L EHD3100L EHD3100L EHD3050L FD3225L FDB3150L FDB3150L FDB3150L FDB3150L FDB3150L FDB3150L FDB3150L FD3225L FD3225L FD3225L FD3225L FD3225L FD3225L FD3225L JDB3250 JDB3250 JDB3250 JDB3250 JDB3250 JDB3250 JDB3250 Enclosure EHB125NS EHB125NF EHB125NRB FA100S FA100F FA100RB FA100AWK FA100A FA100DS FA060X FA060Y FA100X FA100Y KA225S KA225F KA225RB KA225AWK KA225A KA225DS KA225X KA225Y Breaker EHB34100 EHB34100 EHB34100 FAL34100 FAL34100 FAL34100 FAL34100 FAL34100 FAL34100 FAL34060 FAL34060 FAL34100 FAL34100 KAL36250 KAL36250 KAL36250 KAL36250 KAL36250 KAL36250 KAL36250 KAL36250
Siemens Enclosure E2N1S E2N1F E2N3R E2N12 E2N12 ED6SS4 EA EB E2N1S E2N1F E2N3R E2N12 E2N12 ED6SS4 F6N1S F6N1F F6N3R F6N12 F6N12 FD6SS4 EC2 Breaker ED43B100 ED43B100 ED43B100 ED43B100 ED43B100 ED43B100 ED43B100 ED43B100 ED43B125 ED43B125 ED43B125 ED43B125 ED43B125 ED43B125 FXD63B250 FXD63B250 FXD63B250 FXD63B250 FXD63B250 FXD63B250 FXD63B250
General Electric Enclosure TE100S TE100F TE100R TE100J/SE100J TE100D/ ______ TE100CS/SE100CS TE150S TE150F TE150R TF225S TF225F TF225R TF225J/SF250J ______ /SF250D TF225CS/SF250CS
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
WFDN225 1 XFDN225B
1
SFDN225 1 FFDN225 1 RFDN225 1 JFDN225 1 DFDN225 1 WFDN225 1 XFDN225B SJDN250 FJDN250 RJDN250 JJDN250 DJDN250 WJDN250 XJDN250B
1
Notes 1 Maximum wire size 4/0. 2 Maximum wire size 500 kcmil.
www.eaton.com
V2-T1-107
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-108 NEMA Rating 1 surface 1 flush 3R 12/3R 12 12K 4/4X 7/9 1 surface 1 flush 3R 12/3R 12 4/4X 7/9 1 surface 1 flush 3R 12/3R 12 4/4X 7/9 1 surface 1 flush 3R 12/3R 12 4/4X 1 surface 12 3R 1 surface 12 4/4X 7/9 Eaton
Switching Devices
Enclosed Circuit Breakers
Siemens Enclosure J6N1 J6N3R J6N12 J6N12 EE LD6N1 LD6N3R LD6N12 LD6SS4 ED6 LMD1 LMD3R LMD12 MND61 MND63 MND612 Breaker JXD63B400 JXD63B400 JXD63B400 JXD63B400 JXD63B400 LXD63B600 LXD63B600 LXD63B600 LXD63B600 LXD63B600 MXD63B800 MXD63B800 MXD63B800 NXD63B120 NXD63B120 NXD63B120
General Electric Enclosure TJ400S/SG400S TJ400F/SG400F TJ400R/SG400R TJ400J/SG400J ______ /SG400D TJ400CS/SG400CS TJ600S/SG600S TJ600F/SG600F TJ600R/SG600R TJ600J/SG600J TJ600CS TK4V1200S TK4V1200F TKV41200R TK4V1200J/SK1200 TK4V1200S TK4V1200F TKV41200R TK4V1200J/SK1200 Breaker TJK436400WL TJK436400WL TJK436400WL TJK436400WL TJK436400WL TJK436400WL TJK636600WL TJK636600WL TJK636600WL TJK636600WL TJK636600WL TKMA836800WL TKMA836800WL TKMA836800WL TKMA836800WL TKMA31200WL TKMA31200WL TKMA31200WL TKMA31200WL
Enclosure SKDN400
XKDN400B 21 SLDN600 RLDN600 JLDN600 WLDN600 XMCN800B SNDN1200 RNDN1200 JNDN1200 WNDN1200 XMCN800B SNDN1200 RNDN1200 JNDN1200 WNDN1200 SNDN1200 RNDN1200 JNDN1200 WNDN1200 XNDN1200B 2
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1 1 1 1 1 1
Product Selection
1. Use the data on Page V2T1-120 to determine type of enclosure required. 2. Use the data on Page V2T1-114 and V2-T1-115 to determine circuit breaker required. 3. Pages V2-T1-116 through V2-T1-122 include rough-in dimensional information.
Enclosure Only
Breaker Frame Series C Breakers GHC, GD (two- and three-pole only) GHCGFEP (single-pole only) 15100 1 surface 3R 12 12K 4/4X, 5 stainless steel EHD, FD, FDB, HFD 15100 1 surface 1 flush 3R 12 12K 4/4X, 5 stainless steel EHD, FD, FDB HFD, FDC FD, FDB, HFD, ED, EDH, EDC, FDC (15225A) 1550 60225 2 125225 7/9 cast aluminum 7/9 cast aluminum 1 surface 1 flush 3R 12 12K 4/4X, 5 stainless steel JD, JDB, HJD, JDC 125250 1 surface 1 flush 3R 12 12K 4/4X, 5 stainless steel JD, JDB, HJD, JDC 125250 7/9 cast aluminum SGDN100 1 RGDN100 JGDN100 DGDN100 WGDN100 SFDN100 FFDN100 RFDN100 JFDN100 DFDN100 WFDN100 XFDN050B XFDN225B SFDN225 FFDN225 RFDN225 JFDN225 DFDN225 WFDN225 SJDN250 FJDN250 RJDN250 JJDN250 DJDN250 WJDN250 XJDN250B Breaker Ampere Range Enclosure NEMA Class Catalog Number
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Notes 1 Suitable for use with single-pole breaker. Base mounting plate kit. QCCBP required. 2 Maximum wire size: 4/0. 3 Can be field converted to NEMA Type 3R.
www.eaton.com
V2-T1-109
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-110 LGE, LGS, LGH used with ELLBN ND, HND Earth Leakage Breakers MDL, HMDL MDL, HMDL, ND, HND 1 LD, LDB, HLD 1 KD, KDB, HKD, KDC, DK LGE, LGS, LGH Breaker Frame
Switching Devices
Enclosed Circuit Breakers
Series C Breakers, continued KD, KDB, HKD, KDC, DK 125400 1 surface 1 flush 3R 12 12K 4/4X, 5 stainless steel 125400 250600 7/9 cast aluminum 1 surface 3R 12 4/4X, 5 stainless steel 300600 1 surface 3R 12 4/4X, 5 stainless steel 7/9 cast aluminum 400800 4001200 7/9 cast aluminum 1 surface 3R 12 4/4X, 5 stainless steel 7/9 cast aluminum SKDN400 FKDN400 RKDN400 JKDN400 DKDN400 WKDN400 XKDN400B SLG630 RLG630 JLG630 2 WLG630 SLDN600 RLDN600 JLDN600 WLDN600 XLDN600B XMCN800B SNDN1200 RNDN1200 JNDN1200 WNDN1200 XNDN1200B
15100
SFD100E FFD100E RFDN100E JFDN100E DFDN100E WFDN100E SLG630E RLG630 JLG630 2 WLG630
250600
Notes 1 Short-circuit ratings are limited for high interrupting rated breakers. Refer to Page V2-T1-114. 2 Can be field converted to NEMA Type 3R.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1
Description RMS 310 LS RMS 310 LSI RMS 310 LSG 1 RMS 310 LSIG 1
Accessories
Nameplates Applied
Customer must provide nameplate legend at the time of order.
1 1 1 1 1 1 1 1 1
1
RMS 310 LS RMS 310 LSI RMS 310 LSG 1 RMS 310 LSIG
1
MDL, HMDL
RMS 310 LS RMS 310 LSI RMS 310 LSG 1 RMS 310 LSIG 1
RMS 310 LSIG 1 RMS 310 LS RMS 310 LSI RMS 310 LSG RMS 310 LSIG RMS 510 LS 2 RMS 610 LS 2 RMS 810 LS 2 RMS 910 LS 2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
a b
K, L, M, N R
G, F, J, K, L, M, N, R
ST a
Make Break
G, F, J, K, L, M, N F, K, L, M, N
Notes 1 Ground fault application not available with NEMA 7/9. Contact Eatons Customer Support Center. 2 Add to the appropriate RD RMS 310 adder.
G, F, J, K, L, M, N, R
ST
www.eaton.com
V2-T1-111
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-112
Switching Devices
Enclosed Circuit Breakers
Raintight Hubs
All rainproof enclosures 30400A are shipped with plate over cutout. Hubs are not supplied with screws on 30400A enclosures. Use screws from plate. Raintight Tubs
Hub Diameter Hubs Small For use with RGDN and RFDN 0.75 1.00 1.25 1.50 2.00 Large For use with RJDN. RKDN has two cutouts 2.00 2.50 3.00 Required if using small DS hubs on RJDN and RKDN enclosures. 50.8 63.5 76.2 DS200H2 DS250H2 DS300H2 DS900AP 19.1 25.4 31.8 38.1 50.8 DS075H1 DS100H1 DS125H1 DS150H1 DS200H1 Inches mm Catalog Number
Modifications
Allowable accessory combinations can be reviewed in Eatons Circuit Breaker Product Guide: PG.74.A.01.T.E. Verify final application with the Customer Support Center. Special RD Modifications and Accessories
Description 1600 ampere neutral assembly (aluminum) 2000 ampere neutral assembly (aluminum) 2500 ampere neutral assembly (aluminum) 1600 ampere neutral assembly (copper) 2000 ampere neutral assembly (copper) 2500 ampere neutral assembly (copper) Adjustable rating plug Lockoff, padlockable Key interlock Phase failure protection (includes shunt trip) Zero sequence gfp (including shunt trip and test panel) NEMA 3R flat roof Heater package (includes cpt, heater, thermostat and disconnect) Special sized enclosures Standard is 90-inch H x 30-inch W x 30-inch D (2286 x 762 x 762 mm)
Raintight Hubs
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Flex Center
Introduction
The Safety Switch Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized enclosed circuit breakers that meet customers challenging applications. The Flex Center is a solutions center that provides real value:
Satellite Plants
Atlanta 7000 Highlands Parkway SE #102 Smyrna, GA 30082 Fax (770) 433-1863 Phone (678) 309-4260 Baltimore 6671 Santa Barbara Court Suite A Elk Ridge, MD 21075 Fax (410) 796-7755 Phone (410) 796-7777 Chicago 959 AEC Drive Wood Dale, IL 60191 Fax (630) 860-3569 Phone (630) 860-3500 Cleveland 5565 Venture Drive Unit B Parma, OH 44130 Fax (216) 433-0545 Phone (216) 433-0616 Dallas 631 Westport Pkwy Suite 100 Grapevine, TX 76051 Fax (817) 251-6249 Phone (817) 251-6797 Denver 14101 East 33rd Place Suite F Aurora, CO 80011 Fax (303) 371-4175 Phone (303) 371-7844 Hartford 625 Day Hill Road Windsor, CT 06095 Fax (860) 688-4982 Phone (860) 688-5330 Houston 10810 West Little York Suite 100 Houston, TX 77041 Fax (713) 688-3764 Phone (713) 688-8430 Los Angeles 5590 Jurupa Street Ontario, CA 91761 Fax (909) 390-8884 Phone (909) 390-8853 New Jersey 96 Stemmers Lane Westampton, NJ 08060 Fax (609) 835-4777 Phone (609) 835-4230 Orlando 3827 St. Valentine Way Orlando, FL 32811 Fax (407) 841-9135 Phone (407) 843-3863 Phoenix 921 South Park Lane Suite 1 Tempe, AZ 85281-5119 Fax (480) 449-4223 Phone (480) 449-4222 Raleigh 2933 S. Miami Blvd. Suite 111 Durham, NC 27703 Fax (919) 572-9751 Phone (919) 544-7074 St. Louis 12947 Gravois Road St. Louis, MO 63127 Fax (314) 842-2552 Phone (314) 842-7797 San Francisco 20923 Cabot Boulevard Hayward, CA 94545 Fax (510) 784-8980 Phone (510) 784-8981 Seattle 18657 72nd Avenue S. Kent, WA 98032 Fax (425) 251-0079 Phone (425) 251-9081
A dedicated and knowledgeable engineering/ manufacturing/customer service team to meet your needs A production facility stocked with a full arsenal of equipment to get the job done The industrys shortest lead-time Easy ordering through our distributors Factory-installed modifications include (but are not limited to) the following: Special size enclosure Special nameplates Stainless steel flush cover Special paint Lock-on provisions Neutral assemblies factory installed Equipment ground lugsfactory installed Cover control (pilot lights, pushbuttons, selector switches, etc.) Factory-installed G-Frame breakers For application, availability or pricing questions, contact the Safety Switch Flex Center at 1-888-329-9272
SEATTLE
ATLANTA
HARTFORD
CLEVELAND
ST. LOUIS
BALTIMORE RALEIGH
LOS ANGELES
PHOENIX DALLAS
GRAND PRAIRIE
SUMTER
1 1 1 1 1 1 1 1 1 1
NEW JERSEY
HOUSTON
ORLANDO
www.eaton.com
V2-T1-113
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-114
Switching Devices
Enclosed Circuit Breakers
UL Listed Interrupting Rating rms Symmetrical Amperes Number of Poles Vac Vdc Type of Trip 1 Federal Spec. W-C-375b Vac Ratings 120 120/240 240 277 480 600 Vdc Ratings 2 125 250 125/250
1 2, 3 1 2, 3 3
65,000
65,000 65,000
14,000 14,000
14,000 22,000
14,000 14,000
10,000
14,000 14,000
65,000 100,000 200,000 18,000 18,000 18,000 65,000 65,000 100,000 100,000 200,000 200,000
13a 22a
3
13a 22a
3
24a
3
Notes 1 N.I.T.U. is non-interchangeable trip unit and I.T.U. is interchangeable trip unit. 2 Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250 Vdc. 3 Not defined in W-C-375b. 4 Not suitable for use with 100A enclosures.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1
Vdc Ratings
2
UL Listed Interrupting Rating rms Symmetrical Amperes Number of Poles Vac Vdc Type of Trip 1 Federal Spec. W-C-375b Vac Ratings 120 120/240 240 277 480 600 125 250 125/250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
2, 3 2, 3, 4 2, 3, 4
M-Frame MDL HMDL 4 N-Frame ND HND 4 R-Frame RD 8002500 3, 4 600 N.I.T.U. 24a 125,000 65,000 35,000 6001200 6001200 3, 4 3, 4 600 600 N.I.T.U. N.I.T.U. 23a 23a 65,000 100,000 50,000 65,000 25,000 35,000 300800 300800 2, 3 2, 3 600 600 250 250 I.T.U. I.T.U. 23a 23a 65,000 100,000 50,000 65,000 25,000 35,000 22,000 25,000
Notes 1 N.I.T.U. is non-interchangeable trip unit and I.T.U. is interchangeable trip unit. 2 Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250 Vdc. 3 HLD: NEMA 1 enclosed: 240 Vac = 100 kA, 480 Vac = 65 kA, 600 Vac = 35 kA, 250 Vdc = 20 kA, 500 Vdc = 25 kA. NEMA 3R enclosed: 240 Vac = 65 kA, 480 Vac = 50 kA, 600 Vac = 25 kA, 250 Vdc = 20 kA, 500 Vdc = 25 kA. 4 HMDL and HND: NEMA 1 and 3R enclosed: 240 Vac = 100 kA, 480 Vac = 65 kA, 600 Vac = 35 kA, 250 Vdc = 30 kA, 500 Vdc = 30 kA.
www.eaton.com
V2-T1-115
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-116
Switching Devices
Enclosed Circuit Breakers
Dimensions
Approximate Dimensions in Inches (mm)
Notes 1 SFDN100 Series B released 9/15/01. 2 Maximum wire size: 4/0. 3 Total width, including door clip is 9.95 inches (253 mm). 4 Single centered mounting hole provided. 5 Maximum wire size: 500 kcmil.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1
Approximate Weight in Lbs (kg) 12 (5) 15 (7) 15 (7) 32 (15) 53 (24)
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1
1.91 (48.5)
1.84 (46.7)
DWG...95-1562
18.81 (478.0)
NEED ART
1.78 (45.2)
9.13 (232.0)
1
1.84 (46.7) Concentric Knockouts for 1, 1-1/4, 1-1/2 (25.4, 31.8, 38.1) 2 Conduit Quantity: 10
1 1 1 1 1 1 1 1 1 1 1 1 1
1.84 (46.7)
1.91 (48.5)
7.25 (184.1)
1.84 (46.7)
0.69 (17.5)
8.82 (224.0)
Notes 1 Maximum wire size: 4/0. 2 Maximum wire size: 500 kcmil.
www.eaton.com
V2-T1-117
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-118 Frame G, F Earth leakage FBP, FCL F1 J K
2
Switching Devices
Enclosed Circuit Breakers
A D
ON OFF
B
Notes 1 Maximum wire size: 4/0. 2 Maximum wire size: 500 kcmil.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1
Approximate Weight in Lbs (kg) 16 (7) 19 (9) 19 (9) 19 (9) 37 (17) 58 (26) 94 (43) 94 (43) 84 (38) 175 (80)
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 3R Rainproof
E C
ON A D OFF
DWG...95-1562
18.81 (478.0) 19.27 (489.4) 1.84 (46.7) 19.12 (485.6) 1.78 (45.2)
NEED ART
9.13 (232.0)
Concentric Knockouts for 1, 1-1/4, 1-1/2 (25.4, 31.8, 38.1) 2 Conduit Quantity: 5
1.91 (48.5)
0.81 (20.6)
7.25 (184.0)
1.91 (48.5)
1.84 (46.7)
1.91 (48.5)
0.69 (17.5)
8.82 (224.0)
Notes 1 RFDN100 Series B released 9/15/01. 2 Single centered mounting hole provided on RFDN100, Series B. 3 Maximum wire size: 4/0. 4 Maximum wire size: 500 kcmil.
www.eaton.com
V2-T1-119
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-120 Notes 1 Maximum wire size: 4/0. 2 Maximum wire size: 500 kcmil.
Switching Devices
Enclosed Circuit Breakers
D A
ON OFF
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Circuit Breakers
1.2
1
Standard Conduit Size 1 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) 4.00 (101.6) Approximate Weight in Lbs (kg) 38 (17) 57 (26) 104 (47) 145 (66) 170 (77)
Approximate Dimensions in Inches (mm) NEMA 7/9 Cast Aluminum with Weather-Resistant Seals15250A
Breaker Frame F XFDN050B F1 XFDN100B F1 XFDN225B J XJDN225B J XJDN250B Breaker Size Amperes 1550 60100 125225 70225 250 Number of Outlets 4 4 4 4 4 Mounting 1 A 5.50 (139.7) 6.00 (152.4) 10.25 (260.4) 8.50 (215.9) 9.50 (241.3) B 13.13 (333.5) 18.00 (457.2) 22.63 (574.8) 27.13 (689.1) 27.25 (692.2) J 14.13 (358.9) 19.00 (482.6) Inside 1 C 6.13 (155.7) 6.50 (165.1) 11.38 (289.1) 11.25 (285.8) 11.25 (285.8) D 10.75 (273.1) 16.00 (406.4) 20.00 (508.0) 29.88 (759.0) 29.88 (759.0) E 5.25 (133.4) 5.50 (139.7) 6.38 (162.1) 7.38 (187.5) 8.06 (204.7) Outside 1 F 10.63 (270.0) 11.00 (279.4) 16.38 (416.1) 16.00 (406.4) 16.38 (416.1) G 15.25 (387.4) 20.50 (520.7) 25.13 (638.3) 29.50 (749.3) 35.00 (889.0) H 8.88 (225.6) 9.00 (228.6) 9.63 (244.6) 12.31 (312.7) 12.38 (314.5) K1 Dim 2.00 (50.8) 2.31 (58.7) 3.50 (88.9) 4.00 (101.6) 4.19 (106.4)
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
NEMA 7/9 Cast Aluminum with Weather-Resistant SealsDual Three- and Four-Point Mounting Available as Standard on F-Frame 100A and Below
1 1 1 1 1 1 1 1 1 1 1 1 1
Volume 2Commercial Distribution CA08100003EMay 2012 www.eaton.com V2-T1-121
1.2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-122
8 7 6 F-MTG. A
Switching Devices
Enclosed Circuit Breakers
Approximate Dimensions in Inches (mm) 7/9 Cast Aluminum with Weather-Resistant Seals4001200A
Breaker Frame K1 XKDN400B L XLDN600B M XMCN800B N2 XNDN1200B Breaker Size Amperes 400 600 800 1200 Overall Enclosure A 35.00 (889.0) 37.88 (962.2) 47.88 (1216.2) 64.00 (1625.6) B 16.38 (416.1) 23.88 (606.6) 13.63 (346.2) 26.00 (660.4) C 12.63 (320.8) 14.25 (362.0) 12.81 (325.4) 21.38 (543.1) D 7.13 (181.1) 8.25 (209.6) 6.81 (173.0) 14.38 (365.3) Enclosure Mounting E 9.50 (241.3) 16.00 (406.4) 16.13 (409.7) 27.56 (700.0) F 27.25 (692.2) 45.38 (1152.7) 40.75 (1035.1) 38.63 (981.2) G .50 (12.7) .50 (12.7) .50 (12.7) .50 (12.7) Conduit H 3.00 (76.2) 4.00 (101.6) 4.00 (101.6) 6.50 (165.1) I 4.19 (106.4) 5.00 (127.0) 4.00 (101.6) 4.38 (111.3) Hinged Cover J 5.50 (139.7) 6.00 (152.4) 6.00 (152.4) 7.00 (177.8) Standard Conduit Size 4.00 (101.6) 4.00 (101.6) 4.00 (101.6) 4.00 (101.6) Location 1, 3 and 6, 8 1, 3 and 6, 8 1, 3 and 6, 8 1, 3 and 6, 8 Weight Lbs (kg) 170 (77) 419 (190) 228 (104) 567 (257)
H H E-MT
Conduit Openings
Refer to outline dimensions for size and location of standard conduit openings. In addition, 1/2-inch (12.7 mm) openings are drilled and tapped for breather and drain. Unless ordered with breather and drain, these openings are plugged. Refer to Eaton for price of breather and drain.
Notes 1 Maximum wire size: 500 kcmil. 2 Power cables must enter and leave from opposite ends (through-feed).
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Rotary Disconnects
1.3
Page V2-T1-123 V2-T1-123 V2-T1-123 V2-T1-124 V2-T1-125
Contents
Description Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 1 1 1
Product Overview
Provide users with the ability to lock directly wired motor loads in the OFF position to comply with OSHA lockout/ tagout regulations. Also for machine applications that require compact, economical disconnect switches. Enclosed rotary disconnect switches allow safe control and safe disconnect of any motor application.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Padlockable in the OFF position (up to three padlocks) to meet OSHA lockout requirements Available in 1680A ratings 600 Vac, three- and fourpole non-fusible device Rated for making and breaking loads Accepts auxiliary contacts; capability to signal PLC controllers Ground lug connection provided Possibility of adding one power pole and one auxiliary contact NEMA Type 1, 3R, 12, 4, 4X
Meets Article 430 requirements for a separate disconnect means within sight of all motor loads UL listed under Section 508 UL listed File No. E165150 CSA listed under 22.2 No. 14, File 162136
NEC
Open rotary disconnects can be found in Volume 5, Tab 29 (Tab 3 pending) titled: NEMA Manual Starters.
www.eaton.com
V2-T1-123
1.3
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-124 Ampere Rating
Switching Devices
Enclosed Rotary Disconnects
Product Selection
Enclosed Rotary Non-Fusible
Maximum Horsepower Ratings Three-Phase AC 208V 240V 480V 600V NEMA 1 1 Enclosure Indoor Catalog Number NEMA 12 1 2 Enclosure Dust-Tight/ Rainproof Catalog Number NEMA 4X 1 Enclosure Corrosion-Resistant, Stainless Steel Catalog Number NEMA 4X 1 Enclosure Corrosion-Resistant, Non-Metallic Catalog Number NEMA 4X Enclosure PolycarbonateNon-Metallic Catalog Number
Three-Pole, 600 Vac 16 25 30 40 60 80 3 7-1/2 7-1/2 7-1/2 15 15 5 7-1/2 7-1/2 7-1/2 15 20 10 15 15 20 30 40 10 20 20 25 30 40 ER53016UG ER53025UG ER53030UG ER53040UG ER53060UG ER53080UG ER53016UD ER53025UD ER53030UD ER53040UD ER53060UD ER53080UD ER53016UW ER53025UW ER53030UW ER53040UW ER53060UW ER53080UW ER53016UX ER53025UX ER53030UX ER53040UX ER53060UX ER53080UX ER53030UPGB 34 ER53060UPGB 34
Four-Pole, 600 Vac 16 25 30 40 3 7-1/2 7-1/2 7-1/2 5 7-1/2 7-1/2 7-1/2 10 15 20 20 10 20 25 25 ER54016UG ER54025UG ER54030UG ER54040UG ER54016UD ER54025UD ER54030UD ER54040UD ER54016UW ER54025UW ER54030UW ER54040UW ER54016UX ER54025UX ER54030UX ER54040UX
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Rotary Disconnects
1.3
1 1 1 1
Dimensions
Approximate Dimensions in Inches (mm) NEMA Type 1 (1640A)
3.20 (81.3)
1.44 (36.6) Concentric knockouts for 0.5-, 0.75-inch conduit, quantity 4, knockout locations same in top and bottom 5.50 (139.7) 4.11 (104.4) 2.68 (68.1)
1 1 1 1 1 1
8.11 (206.0)
6.55 (166.4)
8.47 (215.1)
6.86 (174.2)
1 1 1 1 1 1 1 1 1
Note: Wire range of switch lugs for 1625A is #6#10 copper, and for 3040A is #8#14. Wire range of ground lugs is #2#14 copper or aluminum.
Concentric knockout for 0.5, 0.75, 1 conduit, quantity 2, knockout location same in top and bottom 0.27 (6.9)
1.86 (47.2) 8.42 (213.9) Concentric knockout for 1.25, 1.5, 2 conduit, quantity 2, knockout location same in top 5.67 and bottom (144.0) 4.23 (107.4) 3.50 (88.9)
1 1 1 1 1 1
10.11 (256.8)
8.56 (217.4)
0.56 (14.2)
10.47 (265.9)
7.75 (196.9)
1 1 1 1 1
www.eaton.com V2-T1-125
Note: Wire range of switch lugs is #1#14 copper. Wire range of ground lugs is #2#14 copper or aluminum.
1.3
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
4.38 (111.3) 5.81 (147.6) 11.98 (304.3) 4.26 (108.0) 5.66 (143.8) 9.98 (253.5)
Switching Devices
Enclosed Rotary Disconnects
2.68 (68.1)
Note: Wire range of switch lugs for 1625A is #6#10 copper, and for 3040A is #8#14 copper or aluminum.
3.50 (88.9)
3.53 (89.7)
Notes: Wire range of switch lugs is #1#14 copper. Wire range of ground lugs is #2#14 copper or aluminum.
V2-T1-126
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Rotary Disconnects
1.3
1 1
1
2.68 (68.1)
1 1 1 1 1 1 1 1 1 1 1 1 1
2.68 (68.1)
6.43 (163.3)
Notes: Wire range of switch lugs for 1625A is #6#10 copper, and for 3040A is #8#14. Wire range of ground lugs is #2#14 copper or aluminum.
1 1
3.50 (88.9)
1 1 1
11.23 (285.2)
3.53 (89.7)
1 1 1 1 1 1 1 1 1
Notes: Wire range of switch lugs is #4#14 copper. Wire range of ground lugs is #2#14 copper or aluminum.
www.eaton.com
V2-T1-127
1.3
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-128
Switching Devices
Enclosed Rotary Disconnects
7.52 (191.0) 5.00 (127.0) 4.00 (101.6) 2.65 (67.3) 9.52 (241.8)
0.31 (7.9) Four Mounting Holes Notes: Wire range of switch lugs for 1625A is #6#10 copper, and for 3040A is #8#14. Wire range of ground lugs is #2#14 copper or aluminum.
13.56 4.48 (113.8) (344.4) 13.41 (340.6) 12.75 (323.8) 4.51 (114.6) 13.56 (344.4)
Notes: Wire range of switch lugs is #1#14 copper. Wire range of ground lugs is #2#14 copper or aluminum.
CA08100003EMay 2012
www.eaton.com
Switching Devices
Enclosed Rotary Disconnects
1.3
1 1
1 1 1 1 1
3.62 (91.9)
6.38 (162.1)
6.00 (152.4)
4.37 (111.0)
1 1 1
0.13 (3.3) 0.02 (0.5)
5.90 (149.9)
1 1 1 1 1 1 1 1
3.90 (99.1)
0.59 (15.0)
8.27 (210.0)
2.67 (67.8)
7.80 (198.1)
7.32 (185.9)
1 1 1 1
0.16 (4.1) 0.02 (0.5)
1 1 1 1 1 1 1 1
4.94 (125.5)
www.eaton.com
V2-T1-129
1.3
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
V2-T1-130
Switching Devices
Enclosed Rotary Disconnects
CA08100003EMay 2012
www.eaton.com