Patch Report for CADSTAR 13.

0 Incremental Patch 2

******************************************************************************* * Patch Release Report * * NOTE This patch will only patch * * CADSTAR 13.0 Patch 1 * *******************************************************************************

Patch Release Name: Patch 2 Product Affected: CADSTAR 13.0 General Note:

This release announces itself as CADSTAR 13.0, Patch 2 in the Help, About CADSTAR dialog.

This patch is only intended for installation into CADSTAR 13.0 Patch 1.

Defect Description Key:

Zuken Number(s) Program Area of Functionality Brief Description of Defect

*******************************************************************************

Defects fixed since CADSTAR 13.0 Patch 1

CS-13099

PCB Design EXPORT_RIF If the final drill diameter (drill diameter plus Drill Oversize value) of a pad/via exceeds the pad/via size, then a circular shape of the final drill diameter is used to represent the pad/via in PREditor. For non-circular pads/vias, this causes the wrong clearance shape to be used during copper pour.

CS-14396 CS-14397 PCB Design EMBEDDED In Embedded Router it is possible to select connections that have been set as invisible in Design Editor.

CS-14418 PCB Design EXPORT_RIF When a component has a placement shape for top electrical layer and bottom electrical layer, both the placement shapes are passed to the router on the same layer (top electrical).

CS-14583 PCB Design EXPORT_RIF If a lengthening pattern contains curved segments, then constraints may not be met when designs are transferred from Design Editor to PREditor XR HS.

CS-14664

Constraint Manager VARIANTS If a bus is deleted in Constraint Manager and the constituent nets are viewed in the Electrical Nets section of the tree view, the logical nets may not be visible.

CS-14702 Constraint Manager ATTRIBUTES Invalid warnings may be displayed when a design containing Net Classes is opened in PREditor XR HS:

"There is already a Net at <pathname> Duplicates will not be displayed in Constraint Manager"

CS-14703 Constraint Manager CONSTRAINT_MANAGER If a Differential Pair is deleted in Constraint Manager and the constituent nets are viewed in the Electrical Nets section of the tree view, the logical nets may not be visible.

CS-14705 PCB Design IMPORT Design Editor will crash when importing a CADIF file if the file was generated with the option 'Output full CADSTAR names to CADIF' selected and Pad Code names exceed 18 characters.

CS-14709 Constraint Manager CONSTRAINT_MANAGER Invalid warnings may be displayed when a design containing Skew Groups is opened in PREditor XR HS:

"Error in CMDsgItem_RemoveNodePair: NULL this argument"

and

"CMguiError within attr/con synchronisation - Failed to upgrade pin <PinName> attribute pin_length_grp (CMD error: 2)"

CS-14727 SCM Design VARIANTS In CADSTAR installations where the SCM Variant Manager authorisation is only available on a network license, there may be performance problems when using the schematic Design Editor.

CS-14748 PCB Design EXPORT_RIF Vias (and pads which have the same Pad Code name as vias) do not retain their teardrop definitions when transferred to PREditor XR, causing teardrops to be lost when the route is modified.

CS-14766 PCB Design EXPORT_RIF When Net Class values are deleted in Design Editor in Non-Legacy mode, the nets are not removed from the Net Class tree in Constraint Manager.

CS-14837 PCB Design DIMENSION_CHECK In rare circumstances, Design Editor may fail to output a DRC spacing violation and only output a Route Offsetting error.

*******************************************************************************

CADSTAR 13.0 patch 2 **WILL NOT** patch any release prior to CADSTAR 13.0 Patch 1.