Information

Analog/ISDN/GeoCENTREX Rejection of Forwarded Calls (RFC)


A30828-X1150-B642-1-7629

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2000


Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

This document consists of a total of 13 pages. All pages are issue 1.

Contents
1 2 3 3.1 3.2 3.3 3.3.1 3.3.2 3.4 3.5 4 5 6 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Subscriber controlled input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 GeoCENTREX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Additional possibilities for feature control . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Call charge registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

A30828-X1150-B642-1-7629

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

1 Denition
The feature Rejection of Forwarded Calls (RFC) allows a subscriber to automatically reject calls that have been forwarded to him or her.

Network node

CF active

calling subscriber

forwarding subscriber RFC active

tone, announcement

STOP directory number to which the call is forwarded

Operator benefits improved service Subscriber benefits no forwarded calls Availability Analog Subscriber GeoCENTREX subscriber Use and effect Calling subscriber RFC use RFC effect Interactions For interaction with other features, see Feature Interactions. ----Called subscriber X X X X ISDN X X

A30828-X1150-B642-1-7629

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

2 Mode of operation
If the feature Rejection of Forwarded Calls (RFC) has been activated for a particular subscriber, the network node checks all his or her incoming connections. If the network node detects a forwarded call, it automatically rejects it. The calling subscriber hears either a tone or an announcement (this is determined by the network operator on a projectspecific basis). If an incoming call is not recognized as being a forwarded call due to the absence of SS7 signaling, the call is switched through. The feature can be activated and deactivated by the operator or by the subscriber by means of subscriber controlled input. The subscriber can check on his or her telephone whether the feature is active. Capacity The percentages indicate the number of authorized subscribers for the feature within the network node and their simultaneous application. Analog Authorization Subscriber GeoCENTREX subscriber 100% 100% Use 5% 5% ISDN Authorization 100% 100% Use 5% 5%

3 Subscriber controlled input


The feature can be administrated by subscriber controlled input. For the subscriber procedure, see: Analog subscriber ISDN subscriber GeoCENTREX Analog subscriber ISDN subscriber Subscriber controlled input functions Signaling method Analog Pulse Activate Deactivate Enter data Delete data Enter data and activate Delete data and deactivate X X DTMF X X ISDN Keypad X X Funct.

-------------

---------

---------

---------

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

Subscriber controlled input functions

Signaling method Analog Pulse DTMF ISDN Keypad Funct.

Activate with/without data Feature use Status request Data request Status request with/without data Access code

----X

----X

----X

-----------

-----

-----

-----

The access code for subscriber controlled input consists of a maximum of 6 characters or, for GeoCENTREX subscribers, a maximum of 5 characters. It can be formed from the symbols 5 , # and the service code (SC) with the digits 0 ... 9. The operator can specify the character strings for the access code. Differences by pulse dialing The selected digits are not obligatory; other digits can be input (depending on the existing numbering plan). 1111 at the beginning of an input in place of 5 1112 at the beginning of an input in place of # 1113 at the beginning of an input in place of 5 # 5 as a disconnecting signal after the service code is not relevant # after the subscriber controlled input is not relevant Acknowledgments after subscriber controlled input The following tones, announcements and display texts are examples and can be administrated by the operator. The display texts can be changed to suit individual projects. The subscriber controlled input can be acknowledged by: Tones ringing tone acceptance tone subscriber busy tone or number unobtainable tone (NU) Announcements subscriber controlled input successful subscriber controlled input unsuccessful feature is already activated feature is not activated feature is not available wrong input Display texts (only in ISDN) wrong input not authorized request rejected successful unsuccessful not available

A30828-X1150-B642-1-7629

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

3.1

Analog
Activate Start PIN optional End Deactivate Start PIN optional End Interrogate state Start PIN optional End DT (( ) IND SC PIN) DT (( ) IND SC PIN) DT (( ) IND SC PIN)

3.2

ISDN
Activate Start PIN optional MSN optional BC optional End Deactivate Start PIN optional MSN optional BC optional End DT (( ( ( IND ) SC PIN) MSN) BC) DT (( ( ( IND ) SC PIN) MSN) BC)

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

Interrogate state Start PIN optional MSN optional BC optional End DT (( ( ( IND ) SC PIN) MSN) BC)

3.3
3.3.1

GeoCENTREX
Analog
For inputs, see subscriber procedure Analog.

3.3.2

ISDN
For inputs, see subscriber procedure ISDN.

3.4

Additional possibilities for feature control


Feature Automatic Feature Subscription (AFS) Remote Subscriber Controlled Input (RSCI) Feature Control Offline (FCOFF) Subscriber Controlled Input via Internet (ISCI) General Facility Reset (GFR) Use ----X X X

A30828-X1150-B642-1-7629

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

3.5

Legend
Introduces activation from terminal or introduces input from terminal or used as separator Introduces deactivation from terminal or introduces cancellation from terminal or used at end of feature input Introduces interrogate state from terminal Enter ... Lift handset Replace handset () BC DT IND MSN PIN SC TT Optional input Basic code Dial tone Indication (tone, announcement, display texts) Multiple subscriber number Personal identification number (4 to 12 digits) Service code Timer in seconds

4 Call charge registration


Call charge registration is possible with: Automatic Message Accounting with Individual Call Charge Registration Pulse Metering Message Detail Recording (MDR) for GeoCENTREX Flat rate Automatic Message Accounting with Individual Call Charge Registration (AMA) and Pulse Metering can be combined. One or more call charge pulses can be generated for Pulse Metering. Charges for feature input and feature usage The charges for operator inputs, successful subscriber controlled input and feature usage are assigned to the subscriber. The following call charge registration is possible: Facility input by operator (FAIO) Facility input by subscriber (FAIS) Facility usage (FAU)

10

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

Action Activate Deactivate Enter data Delete data Assign authorization Remove authorization Assign authorization to modify Remove authorization to modify Status request, data request Use

FAIO X X ----X X ---------

FAIS X X ------------X ---

FAU ------------------X

5 Administration
The operator can perform all administration functions on the NetManager by means of user-friendly applications or MML commands. Feature authorization The network operator assigns authorization for the feature when requested by the subscriber. Subscriber access types The feature can be used with the following types of subscriber access: Type Subscriber Analog Main station Basic access PBX PBX with BA and/or PA PBX line PBX line with Direct Dialing In (DDI) PBX line, connected like a subscriber Coinbox Emergency call station MLHG line Basic attendant console MAC attendant console X --X ------X ----------ISDN --X --X ----------------GeoCENTREX Analog X --X ------X ----------ISDN --X --X -----------------

A30828-X1150-B642-1-7629

11

Rejection of Forwarded Calls (RFC)

Information Analog/ISDN/GeoCENTREX

ISDN basic service The allocation and usage of the feature are service specific. The basic code may be different, depending on the individual project. ISDN basic service All services Circuit mode: speech Circuit mode: 64 kbit/s unrestricted Circuit mode: 3.1 kHz audio Circuit mode: 7 kHz audio Telephony 3.1 kHz Teletex 64 kbit/s Fax group 4 Videotex Video telephony Fax group 2/3 Telephony 7 kHz Call charge registration For more information, please refer to OMN:EXCH-TA. System administration The following feature data can be administrated in the network node: options for subscriber controlled input display and modication of network node options recording by means of trafc measurement For more information, please refer to OMN:EXCH-SY. Routing administration For more information, please refer to OMN:EXCH-RO. Subscriber administration For more information, please refer to OMN:EXCH-SU. GeoCENTREX administration For more information, please refer to OMN:EXCH-CTX. Basic code 00 01 02 03 04 32 33 34 35 36 37 38

12

A30828-X1150-B642-1-7629

Information Analog/ISDN/GeoCENTREX

Rejection of Forwarded Calls (RFC)

6 Requirements
Hardware UI-LTG with OCANEQ speech equipment and INDAS for: acknowledging for subscriber controlled input announcement of rejected calls Signaling Signaling between the network nodes Signaling system no. 7 (SS7) ISDN user part (ISUP) Telephony user part (TUP) Subscriber signaling Analog Dual-tone multi-frequency (DTMF) Pulse dialing ISDN Digital subscriber signaling system no.1 (DSS1) Subscriber interfaces The following interfaces for subscriber access can be used: DLU LTG V5.1 interface V5.2 interface