Professional Documents
Culture Documents
Osiguraci
Osiguraci
URB
Class:
aR
DIN 43653
IEC 60269-1 and -4
DIN VDE 0636-40
UL 248-13
Features / Benefits
Extremely high interrupting rating 100 kA 300 kA
Voltage ratings AC 660 V AC 1000 V
Protection of Power Semiconductors according to IEC 60269-1 and -4
Complies with DIN 43653 sizes 000 and 00
with or without Topindicator and trip microswitch
www.siba.de
URB 1
URB
SICHERUNGEN/FUSES
Selection Guide
Size
Rated Voltage
Fixing Center
Indicator *
Part No.
Type
Selector
Guide
[Page]
Techn.
Data
[Page]
20 282 04
20 282 41
20 558 04
20 282 20
20 282 21
20 558 20
20 189 04
20 189 41
20 412 04
20 189 20
20 189 21
20 412 20
20 560 20
20 560 21
20 562 20
21 189 01
21 189 08
21 189 11
28 002 01
28 002 02
URB 3
URB 3
URB 4
URB 3
URB 3
URB 4
URB 5
URB 5
URB 6
URB 5
URB 5
URB 7
URB 8
URB 8
URB 9
URB 10
URB 10
URB 10
URB 11
URB 11
URB 11
URB 12
URB 12
URB 12
URB 13
URB 13
URB 13
URB 14
URB 14
URB 14
URB 15
URB 15
URB 16
URB 17
URB 17
[AC]
000
000
000
000
000
000
00
00
00
00
00
00
00
00
00
Fuse-Base
Fuse-Base
Fuse-Base
Micro switch
Micro switch
660 V
660 V
660 V
690/700 V
690/700 V
690/700 V
660 V
660 V
660 V
690/700 V
690/700 V
690/700 V
1000 V
1000 V
1000 V
1000 V
1000 V
1000 V
250 V
250 V
URB 2
www.siba.de
SICHERUNGEN/FUSES
URB
Rated Voltage
Standard
000
AC 660 V
DIN 43653
Part No.
with Top Indicator
Part No.
without Top Indicator
[A]
16
20
25
32
35
40
50
63
80
100
125
160
20 282 04.16
20 282 04.20
20 282 04.25
20 282 04.32
20 282 04.35
20 282 04.40
20 282 04.50
20 282 04.63
20 282 04.80
20 282 04.100
20 282 04.125
20 282 04.160
20 282 41.16
20 282 41.20
20 282 41.25
20 282 41.32
20 282 41.35
20 282 41.40
20 282 41.50
20 282 41.63
20 282 41.80
20 282 41.100
20 282 41.125
20 282 41.160
Size
Rated Voltage
000
AC 690/700 V
Rated current
Part No.
with Top Indicator
Pack
[kg/1]
6
6
6
6
6
6
6
6
6
6
6
6
Standard
Part No.
without Top Indicator
DIN 43653
[A]
32
35
40
50
63
80
100
125
160
200
250
315
Weight
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
UL Rec.
Rated Current
UL Rec.
Size
Weight
Pack
[kg/1]
20 282 20.32
20 282 20.35
20 282 20.40
20 282 20.50
20 282 20.63
20 282 20.80
20 282 20.100
20 282 20.125
20 282 20.160
20 282 20.200
20 282 20.250
20 282 20.315
20 282 21.32
20 282 21.35
20 282 21.40
20 282 21.50
20 282 21.63
20 282 21.80
20 282 21.100
20 282 21.125
20 282 21.160
20 282 21.200
20 282 21.250
20 282 21.315
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
6
6
6
6
6
6
6
6
6
6
6
6
www.siba.de
URB 3
URB
SICHERUNGEN/FUSES
A
B
C
D
E
Rated Voltage
Standard
000
AC 660 V
DIN 43653
Part No.
Top Indicator and Fitting for Micro Switch
16
20
25
32
35
40
50
63
80
100
125
160
20 558 04.16
20 558 04.20
20 558 04.25
20 558 04.32
20 558 04.35
20 558 04.40
20 558 04.50
20 558 04.63
20 558 04.80
20 558 04.100
20 558 04.125
20 558 04.160
Size
Rated Voltage
000
AC 690/700 V
Rated
Current
[A]
Part No.
Top Indicator and Fitting for Micro Switch
32
35
40
50
63
80
100
125
160
180
200
250
315
20 558 20.32
20 558 20.35
20 558 20.40
20 558 20.50
20 558 20.63
20 558 20.80
20 558 20.100
20 558 20.125
20 558 20.160
20 558 20.180
20 558 20.200
20 558 20.250
20 558 20.315
URB 4
F
G
H
I
L(max)
Weight
Pack
[kg/1]
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
6
6
6
6
6
6
6
6
6
6
6
6
Standard
DIN 43653
UL Rec.
Rated
Current
[A]
UL Rec.
Size
Weight
Pack
[kg/1]
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
6
6
6
6
6
6
6
6
6
6
6
6
6
0.08 (2 mm)
2.10 (53 mm)
2.76 (70 mm)
1.54 (39 mm)
3.94 (100 mm)
www.siba.de
SICHERUNGEN/FUSES
URB
Rated Voltage
Standard
00
AC 660 V
DIN 43653
Part No.
with Top Indicator
Part No.
without Top Indicator
[A]
16
20
25
32
35
40
50
63
80
100
125
160
200
250
20 189 04.16
20 189 04.20
20 189 04.25
20 189 04.32
20 189 04.35
20 189 04.40
20 189 04.50
20 189 04.63
20 189 04.80
20 189 04.100
20 189 04.125
20 189 04.160
20 189 04.200
20 189 04.250
20 189 41.16
20 189 41.20
20 189 41.25
20 189 41.32
20 189 41.35
20 189 41.40
20 189 41.50
20 189 41.63
20 189 41.80
20 189 41.100
20 189 41.125
20 189 41.160
20 189 41.200
20 189 41.250
Size
Rated Voltage
00
AC 690/700 V
Rated Current
Part No.
with Top Indicator
20 189 20.32
20 189 20.35
20 189 20.40
20 189 20.50
20 189 20.63
20 189 20.80
20 189 20.100
20 189 20.125
20 189 20.160
20 189 20.200
20 189 20.250
20 189 20.315
20 189 20.350
20 189 20.400
[kg/1]
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Part No.
without Top Indicator
20 189 21.32
20 189 21.35
20 189 21.40
20 189 21.50
20 189 21.63
20 189 21.80
20 189 21.100
20 189 21.125
20 189 21.160
20 189 21.200
20 189 21.250
20 189 21.315
20 189 21.350
20 189 21.400
DIN 43653
Weight
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
Pack
[kg/1]
3
3
3
3
3
3
3
3
3
3
3
3
3
3
A
B
C
D
E
www.siba.de
Pack
Standard
[A]
32
35
40
50
63
80
100
125
160
200
250
315
350
400
Weight
UL Rec.
Rated Current
UL Rec.
Size
F
0.10 (2,5 mm)
I
1.85 (47 mm)
L(max) 4.13 (105 mm)
URB 5
URB
SICHERUNGEN/FUSES
A
B
C
D
E
Rated Voltage
Standard
00
AC 660 V
DIN 43653
Rated
Current
[A]
Part No.
Top Indicator and Fitting for Micro Switch
16
20
25
32
35
40
50
63
80
100
125
160
200
250
20 412 04.16
20 412 04.20
20 412 04.25
20 412 04.32
20 412 04.35
20 412 04.40
20 412 04.50
20 412 04.63
20 412 04.80
20 412 04.100
20 412 04.125
20 412 04.160
20 412 04.200
20 412 04.250
URB 6
F
G
H
I
L(max)
UL Rec.
Size
Weight
Pack
[kg/1]
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
3
3
3
3
3
3
3
3
3
3
3
3
3
3
www.siba.de
SICHERUNGEN/FUSES
URB
Rated Voltage
00
AC 690/700 V
Rated
Current
[A]
Part No.
Top Indicator and Fitting for Micro Switch
32
35
40
50
63
80
100
125
160
200
250
315
350
400
20 412 20.32
20 412 20.35
20 412 20.40
20 412 20.50
20 412 20.63
20 412 20.80
20 412 20.100
20 412 20.125
20 412 20.160
20 412 20.200
20 412 20.250
20 412 20.315
20 412 20.350
20 412 20.400
Standard
DIN 43653
UL Rec.
Size
Weight
[kg/1]
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
3
3
3
3
3
3
3
3
3
3
3
3
3
3
A
B
C
D
E
www.siba.de
Pack
F
G
H
I
L(max)
URB 7
URB
SICHERUNGEN/FUSES
Rated Voltage
00
AC 1000 V
Rated Current
Part No.
with Top Indicator
Standard
DIN 43653
Part No.
without Top Indicator
[A]
32
40
50
63
80
100
125
160
200
250
315*
20 560 20.32
20 560 20.40
20 560 20.50
20 560 20.63
20 560 20.80
20 560 20.100
20 560 20.125
20 560 20.160
20 560 20.200
20 560 20.250
20 560 20.315
20 560 21.32
20 560 21.40
20 560 21.50
20 560 21.63
20 560 21.80
20 560 21.100
20 560 21.125
20 560 21.160
20 560 21.200
20 560 21.250
20 560 21.315
UL Rec.
Size
Weight
Pack
[kg/1]
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
3
3
3
3
3
3
3
3
3
3
3
* 900 Vac
A
B
C
D
E
URB 8
F
0.10 (2,5 mm)
I
1.85 (47 mm)
L(max) 4.13 (105 mm)
www.siba.de
SICHERUNGEN/FUSES
URB
Rated Voltage
00
AC 1000 V
Rated
Current
[A]
Part No.
Top Indicator and Fitting for Micro Switch
32
40
50
63
80
100
125
160
200
250
315*
20 562 20.32
20 562 20.40
20 562 20.50
20 562 20.63
20 562 20.80
20 562 20.100
20 562 20.125
20 562 20.160
20 562 20.200
20 562 20.250
20 562 20.315
Standard
DIN 43653
UL Rec.
Size
Weight
Pack
[kg/1]
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
3
3
3
3
3
3
3
3
3
3
3
* 900 Vac
A
B
C
D
E
www.siba.de
F
G
H
I
L(max)
URB 9
URB
Electrical Characteristics
SICHERUNGEN/FUSES
Size
Rated Voltage
Operating Class
000
AC 660 V
aR
Rated
Current
[A]
Part No.
with Top Indicator
16
20
25
32
35
40
50
63
80
100
125
160
20 282 04.16
20 282 04.20
20 282 04.25
20 282 04.32
20 282 04.35
20 282 04.40
20 282 04.50
20 282 04.63
20 282 04.80
20 282 04.100
20 282 04.125
20 282 04.160
100 kA
Part No.
Part No.
Power
without Top Indicator Fitting for Micro Switch Loss
[W]
20 282 41.16
20 282 41.20
20 282 41.25
20 282 41.32
20 282 41.35
20 282 41.40
20 282 41.50
20 282 41.63
20 282 41.80
20 282 41.100
20 282 41.125
20 282 41.160
20 558 04.16
20 558 04.20
20 558 04.25
20 558 04.32
20 558 04.35
20 558 04.40
20 558 04.50
20 558 04.63
20 558 04.80
20 558 04.100
20 558 04.125
20 558 04.160
Cut-Off characteristics
5
6
7
9
9
10
11
13
18
22
24
28
Pre-arcing
l2t-value
[A2s]
Total
l2t-value @ 660 V
[A2s]
10
17
29
66
81
103
184
330
512
930
1 650
4 250
70
120
200
450
550
700
1 300
2 300
3 500
6 400
11 200
29 000
Time-Current Characteristics
t(s)
Ic
(kA)
Arc voltage-Diagram
I(kA)
UL
____
KB
VAC
KW
UB
____
UB
____
IB
___
VAC
VAC
IN
URB 10
I(A)
www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
Size
Rated Voltage
Operating Class
000
AC 690/700 V
aR
Rated
Current
[A]
Part No.
with Top Indicator
32
35
40
50
63
80
100
125
160
180
200
250
315
20 282 20.32
20 282 20.35
20 282 20.40
20 282 20.50
20 282 20.63
20 282 20.80
20 282 20.100
20 282 20.125
20 282 20.160
20 282 20.180
20 282 20.200
20 282 20.250
20 282 20.315
Part No.
Part No.
Power
without Top Indicator Fitting for Micro Switch Loss
[W]
20 282 21.32
20 282 21.35
20 282 21.40
20 282 21.50
20 282 21.63
20 282 21.80
20 282 21.100
20 282 21.125
20 282 21.160
20 282 21.180
20 282 21.200
20 282 21.250
20 282 21.315
URB
20 558 20.32
20 558 20.35
20 558 20.40
20 558 20.50
20 558 20.63
20 558 20.80
20 558 20.100
20 558 20.125
20 558 20.160
20 558 20.180
20 558 20.200
20 558 20.250
20 558 20.315
Cut-Off characteristics
8
9
10
12
14
18
22
26
32
35
39
47
58
Pre-arcing
l2t-value
[A2s]
Total
l2t-value @ 660 V
[A2s]
52
66
90
140
250
470
730
1 300
2 800
3 700
4 500
8 000
14 000
290
360
500
770
1 400
2 600
4 000
7 200
15 400
20 400
25 000
44 000
77 000
Time-Current Characteristics
t(s)
Ic
(kA)
Arc voltage-Diagram
I(kA)
UL
____
KB
VAC
KW
UB
____
UB
____
IB
VAC
VAC
IN
www.siba.de
___
I(A)
URB 11
URB
Electrical Characteristics
SICHERUNGEN/FUSES
Size
Rated Voltage
Operating Class
00
AC 660 V
aR
Rated
Current
[A]
Part No.
with Top Indicator
16
20
25
32
35
40
50
63
80
100
125
160
200
250
20 189 04.16
20 189 04.20
20 189 04.25
20 189 04.32
20 189 04.35
20 189 04.40
20 189 04.50
20 189 04.63
20 189 04.80
20 189 04.100
20 189 04.125
20 189 04.160
20 189 04.200
20 189 04.250
100 kA
Part No.
Part No.
Power
without Top Indicator Fitting for Micro Switch Loss
[W]
20 189 41.16
20 189 41.20
20 189 41.25
20 189 41.32
20 189 41.35
20 189 41.40
20 189 41.50
20 189 41.63
20 189 41.80
20 189 41.100
20 189 41.125
20 189 41.160
20 189 41.200
20 189 41.250
20 412 04.16
20 412 04.20
20 412 04.25
20 412 04.32
20 412 04.35
20 412 04.40
20 412 04.50
20 412 04.63
20 412 04.80
20 412 04.100
20 412 04.125
20 412 04.160
20 412 04.200
20 412 04.250
Cut-Off characteristics
4.6
5.5
6.7
8.9
9.2
9.8
11.0
13.0
15.0
18.0
22.0
26.0
28.0
31.0
Pre-arcing
l2t-value
[A2s]
Total
l2t-value @ 660 V
[A2s]
10
17
29
66
81
103
184
330
512
930
1 650
4 250
8 000
16 800
70
120
200
450
550
700
1 300
2 300
3 500
6 400
11 200
29 000
54 400
114 300
Time-Current Characteristics
t(s)
Ic
(kA)
Arc voltage-Diagram
I(kA)
UL
____
KB
VAC
KW
UB
____
UB
____
IB
___
VAC
VAC
IN
URB 12
I(A)
www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
Size
Rated Voltage
Operating Class
00
AC 690/700 V
aR
Rated
Current
[A]
Part No.
with Top Indicator
35
40
50
63
80
100
125
160
180
200
250
315
350
400
20 189 20.35
20 189 20.40
20 189 20.50
20 189 20.63
20 189 20.80
20 189 20.100
20 189 20.125
20 189 20.160
20 189 20.180
20 189 20.200
20 189 20.250
20 189 20.315
20 189 20.350
20 189 20.400
Part No.
Part No.
Power
without Top Indicator Fitting for Micro Switch Loss
[W]
20 189 21.35
20 189 21.40
20 189 21.50
20 189 21.63
20 189 21.80
20 189 21.100
20 189 21.125
20 189 21.160
20 189 21.180
20 189 21.200
20 189 21.250
20 189 21.315
20 189 21.350
20 189 21.400
URB
20 412 20.35
20 412 20.40
20 412 20.50
20 412 20.63
20 412 20.80
20 412 20.100
20 412 20.125
20 412 20.160
20 412 20.180
20 412 20.200
20 412 20.250
20 412 20.315
20 412 20.350
20 412 20.400
Cut-Off characteristics
8
10
12
14
17
21
25
31
34
37
44
53
57
68
Pre-arcing
l2t-value
[A2s]
Total
l2t-value @ 660 V
[A2s]
66
90
140
250
470
730
1 300
2 800
4 200
5 000
8 500
15 600
20 000
28 400
360
500
770
1 400
2 600
4 000
7 200
15 400
23 100
27 500
46 800
86 000
110 000
156 000
Time-Current Characteristics
t(s)
Ic
(kA)
Arc voltage-Diagram
I(kA)
UL
____
KB
VAC
KW
UB
____
UB
____
IB
VAC
VAC
IN
www.siba.de
___
I(A)
URB 13
URB
Electrical Characteristics
SICHERUNGEN/FUSES
Size
Rated Voltage
Operating Class
00
AC 1000 V
aR
Rated
Current
[A]
Part No.
with Top Indicator
32
40
50
63
80
100
125
160
200
250
315*
20 560 20.32
20 560 20.40
20 560 20.50
20 560 20.63
20 560 20.80
20 560 20.100
20 560 20.125
20 560 20.160
20 560 20.200
20 560 20.250
20 560 20.315
100 kA
Part No.
Part No.
Power
without Top Indicator Fitting for Micro Switch Loss
[W]
20 560 21.32
20 560 21.40
20 560 21.50
20 560 21.63
20 560 21.80
20 560 21.100
20 560 21.125
20 560 21.160
20 560 21.200
20 560 21.250
20 560 21.315
20 562 20.32
20 562 20.40
20 562 20.50
20 562 20.63
20 562 20.80
20 562 20.100
20 562 20.125
20 562 20.160
20 562 20.200
20 562 20.250
20 562 20.315
14
16
18
22
25
28
32
40
46
51
59
Pre-arcing
l2t-value
[A2s]
Total
l2t-value at 1000 V
[A2s]
32
56
100
180
410
740
1 300
2 600
4 600
8 200
16 000
220
400
700
1 200
2 800
5 000
9 000
17 500
31 000
55 000
106 000
* 900 Vac
Cut-Off characteristics
Time-Current Characteristics
t(s)
Ic
(kA)
Arc voltage-Diagram
I(kA)
UL
____
KB
VAC
KW
UB
____
UB
____
IB
___
VAC
VAC
IN
URB 14
I(A)
www.siba.de
Electrical
Electrical Characteristics
characteristics
Fuse-Base 400 A
SICHERUNGEN/FUSES
Size
Rated Voltage
000 and 00
AC 1000 V
URB
Standard
DIN 43653
1000 V
Part No. 21 189 01
Rated Current: 400 A
Rated Power Acceptance: 34 W
Nut Torque: 12 Nm
A
B
C
D
E
F
G
H
I
J
K
L(max)
M
N
Fuse-Base 400 A
Size
Rated Voltage
000 and 00
AC 1000 V
Standard
DIN 43653
1000 V
Part No. 21 189 08
Rated Current: 400 A
Rated Power Acceptance: 34 W
Nut Torque: 12 Nm
with covers
www.siba.de
URB 15
URB
SICHERUNGEN/FUSES
Fuse-Base 400 A
Size
Rated Voltage
000 and 00
AC 1000 V
Standard
DIN 43653
600 V
Part No. 21 189 11
Rated Current: 400 A
Rated Power Acceptance: 34 W
Nut Torque: 12 Nm
A
B
C
D
E
F
G1
G2
H
I
J
K
L(max)
M
N
URB 16
www.siba.de
URB
SICHERUNGEN/FUSES
Rated Voltage
GL-Switch
AC 250 V
Article
Number
use for
Weight
Pack
[kg]
28 002 01
NH00 DIN 80
0.02
10
28 002 02
NH000 DIN 80
0.02
10
Interrupting rating
AC 250 V
AC 250 V
DC 33 V
DC 26 V
ohmsch
ind.
ohmsch
L/R 10 ms
5A
3A
3A
3A
Terminals
Dimensions
Part No.
www.siba.de
Part No.
URB 17
URB
URB 18
Notes
SICHERUNGEN/FUSES
www.siba.de