100% Water Saving Code Compliant Testing Simplicity of Testing Less System Corrosion

A closed loop system that re-circulates water to simulate without discharging water

Zonecheck is a sustainable solution for sprinkler system ow-switch testing, that can cut costs and save time when carrying out mandatory tests.
The NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water Based Fire Protection Systems, mandates wet re sprinkler system ow switches must be tested on a quarterly basis.
For these, and other reasons it is sometimes ignored and the standards are contravened. Flow switches installed in a sprinkler system are required to be tested on a quarterly basis, and for that test to be valid,

The unique Zonecheck and inexpensively. is installed or located on the system. Zonecheck normal functioning of the building. No issues with the Fire Services No additional manpower required Reduced corrosion

The Functional Principle


The Zonecheck solution is simply to connect a

this time without any loss of water from the system.

Zonecheck simply re-circulates the existing static pressure), creating a closed system with no water discharge.

Addressable Technology
In response to the ever-increasing size and complexities of modern buildings, coupled with demand for developed Zonecheck Addressable. Zonecheck Addressable allows users to fully comply with the codes for the routine testing of system The system utilises digital communication between connected Zonecheck Addressable units and a central Control Panel via a single loop of cable. The Control Panel facilitates the remote operation of any connected Zonecheck Addressable unit, with the resulting information being returned to the panel.

www.gvi ow.com/zonecheck Zonecheck Addressable can also be monitored with Project Fires Kodecheck Fire Sprinkler Management System that provides for the remote monitored reporting of routine inspections and tests, with full asset tracking audit trail records.

To learn more about Zonecheck, view and obtain product and technical information please visit

sustainability
in Fire Protection

www.gvi ow.com

Product Solutions
Zonecheck

100% Water Saving


With Zonecheck there is no unnecessary discharge of water. Typically with 4 tests required per annum, Zonecheck saves 1280 litres of water per annum for each is not replaced during testing, pipe corrosion is also reduced.

The new build Zonecheck is factory assembled and tested complete with rolled ends for simple site installation in new buildings.

Zonecheck Addressable

and lower costs


pumps to be operated and manually switched of after each test. Zonecheck creates a closed loop required to operate. With Zonecheck, as no water is discharged, testing is easy, takes less time and requires no additional manpower.

The latest version of Zonecheck has been developed to incorporate a single addressable loop of cable to interconnect with a central control panel.

Zonecheck Prewired

A factory wired and tested Zonecheck for easier site installation and reducing installation costs.

Zonecheck Live

Zonecheck live has been engineered to simplify See www.gvi ow.com/livetap

Reduced life cycle carbon footprint


Testing with Zonecheck is quicker requiring less resources (water and electricity) substantially reducing the carbon footprint of maintaining a sprinkler system.

Zonecheck

Permits installation of Zonecheck to existing

Installation

Zonecheck connects into a wet-pipe sprinkler system using two mechanical couplings (sized to match pipe diameter). Approved zonecheck equipment shall be installed throughout the property in accordance with the code standards for zoning.

Standards

In the majority of multi-occupancy sprinklered premises it is a requirement of NFPA 25 that for every tted ow-switch a functional test should be carried out every quarter. Zonecheck can carry out this ow-switch test automatically at a preset time each week. Zonecheck is currently approved by Factory Mutual, Underwriters Laboratories, Underwriters Laboratories Canada.

Operating Principle
The Zonecheck pump re-circulates water around the ow switch at a pressure equal to one sprinkler head discharging water (0.5 bar). As water operates the ow-switch paddle, an electronic signal is sent back to the keyswitch to indicate that the ow-switch has operated correctly. Throughout the whole process water is being re-circulated within the system and no water is discharged Zonecheck is a closed system.

Technical Detail
Zonecheck is supplied as an assembled unit to minimum schedule 10 pipe. Supplied with rolled ends, an end-end distance of 25.6 with black paint nish. Zonecheck is available in the following pipe diameters: 2, 2 1/2, 3, 4.
Working Pressure Rating Operating Temperature Range Compatible Pipe (Manifold Models) Compatible Pipe (Retro- t Models) Component Connections Valves

Standard Speci cation

15 bar maximum 0C - 49C (32F 120F) Schedule 10, 2 - 4 diameter (6 & 8 available as special order) Schedule 10 and 40, 2 - 8 diameter 2 - 1 NPT/25mm British Standard, Thread elbows Red: Standard valve, Green: Contains check valve

Electrical Speci cations

Circulation Pump Approvals Operating Voltage Full Load Current Power Rating IP Rating WP Rating

UL, ULC, FM 120v 60Hz 1.63 A 185 W IP43 175 psi

Water- ow Detector (Manifolds Models Only) Contact Rating Triggering Flow Rate Static Pressure Operating Temperature Key Switch Operating Voltage Key switch Operation Modes Key Switch LED Operation Test Initiation: Flow Switch Activation: Full Load Current Power Input (P1) Rated Power (P2) Capacitor Mounting Options

10A @ 125/250 AC 20-57 litres per minutes 17.25 bar (250 psi) 0C 49C (32F 120F) ZCK-1; single-phase 120V-60Hz Self-test: Wired locally Group test: Interconnected Ready state: No LED PUMP LED (green) Water ow LED (red) 1.63 A 185 W 90 W 400 VDB Includes back box for surface or ush mounting. For pre-wired, use 4 11/16 x 4 11/16 back box.

t: 763.391.0990 f: 763.391.7668 e: info@gvi ow.com a: 8730 Je erson Highway Osseo, MN 55369 USA