HF Series Compressed Air Filters

Flows from 20 to 21,250 scfm (34 to 36.119 m3/h) Maximum working conditions of 300 psig & 150 (21 bar, 66 F C)

The Objective
To meet and exceed the global demand for:

Quality & reliability

Energy Savings

Product Communication

HF Series Filters

Hankison Quality is Built into Every Housing


Epoxy coated interior and exterior Threaded discharge connection Bayonet head to bowl connection up to 170 scfm (289 m3/h) Thermoset polyurethane liquid level indicator Every housing tested to a 5:1 factor of safety

HF Series Filters

Hankison Quality is Built into Every Filter Element


All stainless steel inner and outer cores Complete seam welded cores having a burst pressure of 65 psid (4.5 bar) Coated foam sleeves providing protection against chemical attacks 100% silicone free

HF Series Filters

Complete Filter Offering


Seven grades of filtration allow systems to be precisely customized Each element grade is tested to international standards

HF Series Filters

Grade 11 - Bulk Liquid Separator


A labyrinth style flow path removes liquid water from the air stream by forcing abrupt directional changes Liquid water impinges on the walls of the internal cores while the air stream flows easily through the labyrinth, providing minimal pressure losses Efficient to 5% of rated flow Removes up to 30,000 ppm liquid contamination at efficiencies greater than 90%

HF Series Filters

Grade 9 - Separator/Filter
99% efficient at removing up to 25,000 ppm liquid water from an air stream In-depth coalescing bed captures solid and liquid contaminates 3 micron in size and larger

HF Series Filters

Grade 7 - Air Line Filter


Coarse coalescing filter capable of providing ISO 8573.1 class 2 solid and class 3 oil content air Captures and removes particles 1.0 micron and larger in size Remaining oil content as low as 1.0 mg/m3 Extends life of fine coalescing Filters

HF Series Filters

Grade 6 - Desiccant Afterfilter


Designed to remove solid particles down to 1.0 micron in size in a dry air flow Long life afterfilter for heatless desiccant dryers Outside/in flow, extends the usable life of the filter

HF Series Filters

Grade 5 - High Efficiency Coalescing Oil Removal Filter


Capable of providing ISO 8573.1 class 1 Solid and Class 1 oil content air quality

Captures 99.99+% of all oil aerosols Reduces oil aerosol content to 0.008 ppm (0.01 mg/m3)

HF Series Filters

Grade 3 - Maximum Efficiency Coalescing, Oil Removal Filter


Capable of providing air quality greater than ISO 8573.1 class 1 solids and oil content air quality Captures 99.999+% of all oil aerosols Reduces oil aerosol content to 0.0008 ppm (0.001 mg/m3) Best suited to critical applications

HF Series Filters

Grade 1 Oil Vapor Removal Filter


Capable of providing ISO 8573.1 class 1 solid and oil content air quality Activated carbon adsorption filter Contains 2x more carbon than supplied by industrial activated carbon filters Reduces oil aerosol content (as a vapor) to 0.003 ppm

HF Series Filters

Save Energy with HF Series Filters


Filter housing provides large flow paths which minimizes pressure losses The seven element grades allow for system customization

HF Series Filters

Elements Designed to Extend Life and Reduce Pressure Losses


Large 45% open area stainless steel cores provide even air flow through media at minimal pressure losses Filter media with over 96% void volume, lowers pressure losses while matrix blended media increases capture efficiency Thick filter bed extends useable life without adding pressure losses

HF Series Filters

Reliable Differential Pressure Gauges & Monitor Save Energy


Three available methods of Differential pressure indication Electronic intelligence of the Filter Monitor Face Gauge Slide Indicator Changing the filter elements at the proper time saves energy and protects the compressed air system

HF Series Filters

Saving Energy by Replacing Filter Elements


Reduce energy losses by knowing when its cost effective to replace the filter elements Differential pressure gauges determine the end of an elements life. Further contaminant loading beyond this point greatly increases system pressure losses Saves money and greatly minimize pressure losses in systems by replacing the elements at the end of their efficient life Filter monitor calculates the point of maximum element efficiency. Loading beyond this point increases pressure to the end of the elements life.

HF Series Filters

The Filter Monitor Evaluates:


Differential Pressure Time based Filter performance

HF Series Filters

TimeDifferential Pressure and Time-Based Indications of Element Replacement


Limits False Maximum Pressure Warnings Provides a count down of days starting at 60

HF Series Filters

Filter Performance Indication of Element Replacement


Calculates the moment of optimal element replacement Provides a 60 day notice before reaching the replacement point Monitor mathematically graphs the daily average differential pressure Monitor compares the calculated graph to a known performance graph for each filter to determine the optimum point of element replacement

HF Series Filters

Communicating with the Filter Monitor


All programming equipment is onboard Uses (3) standard AA batteries for simple maintenance

HF Series Filters

Filter Monitor Communication with the User


Provides instantaneous differential pressure values Provides daily average differential pressure values Provides a 60 day warning of impending element replacement

HF Series Filters

Filter Monitor Communications


Uses a RJ11 communications port to interface with the Monitor Relay Box

HF Series Filters

Remote Alarm Capabilities


RJ11 connection on the monitor can send an alarm signal to the relay box as far as 100 feet away The relay box provides dry alarm contacts to indicate the alarm mode of the Filter Monitor and an electronic demand drain The relay box powers both the Filter Monitor and the electric demand drain

HF Series Filters

You might also like