International Limited: Drill Collar Inspection Report

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

JC International Limited RC.

413243
CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILL COLLAR INSPECTION REPORT


W.O.NO.
15042
DATE: 30/01/2013

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.

DRILL COLLAR SIZE: 8.1/4 AND 8''

CONNECTION: 6.5/8 REG

INSPECTION PROGRAM:

VISUAL CONNECTIONS, BLACKLIGHT CONNECTIONS, MPI SLIP/ UPSET/ ELEVATOR GROOVES, DIMENSIONAL 3

SPECIFICATION:

DS-1 STANDARD. CATEGORY

1
TUBE COND. LENGTH (FT.) Bevel Dia BOX TOOL JOINT Counterbore Boreback Dia Depth Length Dia Lead Gauge Tong Space Bevel Dia PIN TOOL JOINT Conn SRG Length Width Dia Lead Gauge Tong Space Slip Recess Depth

2 3-5 ALL DIMENSIONS IN INCHES


MPI Elev Area BSR OD

IDENTIFICATION NO

OD

COND

ID

Neck Length

COND

ELEVATOR & SLIP AREA Elev. MPI Recess Slip Depth Area

PD 0025

29.29

8.1/4

7.3/4

6.1/16

5/8

8.7/16

5.5/32

43

OK

2.15/16

7.5/8

7 . 5 / 7

4.7/8

23/32

5.7/16

12.1/4

OK

1/4

ACC

ACC

8.1/4

AM 09

7.1/4 30.58 8.1/8 7.13/16 29.56 8.1/16 7.5/8 30.28 8.1/8 7.5/8 30.40 8.1/2 7.15/32 29.90 7.7/8 7.11/16 29.41 8.1/8 7.11/16 30.31 8.1/16

6.1/16

5/8 8.31/32 5.7/32 35.5/16

OK

2.7/8

AM 06

6.1/16

11/16 8.3/4 5.9/32 41.7/16

OK

AM 04

6.1/16

23/32 8.3/4 5.7/32 17.1/4

OK

2.13/16

AM 010

6.1/16

23/32 8.3/4 5.1/4 34.1/4

OK

2.13/16

AM 08

6.1/16

7/16 8.23/32 5.2/16 29.1/8

OK

2.13/16

T004-W

6.1/16

11/16 8.13/16 5.3/16 19.5/8

OK

2.7/8

AM 05

6.1/16

11/16 8.25/32 5.3/16 34.1/16

OK

2.13/16

. 9 7 7.23/32 . 2 7 7.7/8 . 7 / 7 7.9/16 . 9 7 7.3/8 . 3 7 7.1/2 . 1 7 7.17/32 . 1

7.9/16

5.3/8 4.15/16 7/8 5.3/8 4.15/16 3/8 5.11/16 4.7/8 23/32 5.7/16 4.15/16 31/32 5.7/16 4.29/32 23/32 5.7/16 4.7/8 1 5.13/32 4.29/32 1 12.15/16 13.3/4 21.3/16 13.1/2 12.5/8 15.1/8 15.3/8

OK

9/32

ACC

ACC

8.1/16

OK

3/16

ACC

ACC

8.1/16

OK

5/32

ACC

ACC

2.78

8.1/8

OK

1/4

ACC

ACC

8.1/8

OK

5/32

ACC

ACC

7.15/16

PT

1/8

ACC

ACC

8.1/8

PT

3/8

ACC

ACC

8.1/16

Max Reqd. Min. Reqd.


SD = Seal Damaged TD = Thread Damaged BB = Belled Box ST = Streched Threads GT = Galled Threads CRK = Crack WO = Wash Out PS = Pitted Seal PT = Corroded Threads CT = Corroded Threads RF = Refaced ACC = Acceptable REJ = Rejected NA = Not Applicable HB = Hard Band

RECESS DEPTH ( INCHES +1/32",-0)


LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

6 2 0 0 8

CONNECTIONS REFACED

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILL COLLAR INSPECTION REPORT


W.O.NO.
15170
DATE: 25/01/2013

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.

DRILL COLLAR SIZE: 9.1/2''

CONNECTION: 7.5/8 REG

INSPECTION PROGRAM:

VISUAL CONNECTIONS, BLACKLIGHT CONNECTIONS, MPI SLIP/ UPSET/ ELEVATOR GROOVES, DIMENSIONAL 3

SPECIFICATION:

DS-1 STANDARD. CATEGORY

1
TUBE COND. LENGTH (FT.) Bevel Dia BOX TOOL JOINT Counterbore Boreback Dia Depth Length Dia Lead Gauge Tong Space Bevel Dia PIN TOOL JOINT Conn SRG Length Width Dia Lead Gauge Tong Space Slip Recess Depth

2 3-5 ALL DIMENSIONS IN INCHES


MPI Elev Area BSR OD

IDENTIFICATION NO

OD

COND

ID

Neck Length

COND

ELEVATOR & SLIP AREA Elev. MPI Recess Slip Depth Area

JSH 0904371.7241 .3762

OK

30.97

9.7/16

8.13/16

7.1/16

11/16

9.1/8

5.7/8

ACC

43.7/8

OK

3.1/8

6186

8.13/16 OK 30.98 9.1/2 8.13/16 OK 30.98 9.1/2 8.7/8 OK 31.00 9.1/2

7.1/16

11/16 9 5.7/8 ACC 37.1/16 OK

3.1/8

62285

7.1/16

11/16 8.5/8 5.7/8 ACC 16.3/16 OK

3.1/8

61734

7.1/16

11/16 9.1/16 5.7/8 ACC 41.5/8 OK

3.1/16

7 8.27/32 . 5 / 7 8.27/32 . 9 7 8.13/16 . 2 3 7 8.13/16 . 7 /

5.3/16

6.5/16

25

PT

5/32

ACC

ACC

2.97

6.5/16 5.3/16 1 6.5/16 5.1/4 1 6.13/32 5.1/4 1 40.9/16 22.1/2 24.1/2

OK

7/32

ACC

ACC

2.97

OK

6/32

ACC

ACC

2.97

OK

9/32

ACC

ACC

2.97

Max Reqd. Min. Reqd. RECESS DEPTH ( INCHES +1/32",-0)

SD = Seal Damaged TD = Thread Damaged BB = Belled Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Corroded Threads CT = Corroded Threads

RF = Refaced LENGTHS READY FOR USE ACC = Acceptable REJ = Rejected NA = Not Applicable LENGHTS WITH PIN & BOX CONN. REJECTED HB = Hard Band TOTAL LENGTHS INSPECTED LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

3 1 0 0 4

CONNECTIONS REFACED

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILL COLLAR INSPECTION REPORT


W.O.NO.
15171
DATE: 30/01/2013

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.

DRILL COLLAR SIZE: 8''

CONNECTION: 6.5/8 REG

INSPECTION PROGRAM:

VISUAL CONNECTIONS, BLACKLIGHT CONNECTIONS, MPI SLIP/ UPSET/ ELEVATOR GROOVES, DIMENSIONAL 3

SPECIFICATION:

DS-1 STANDARD. CATEGORY

1
TUBE COND. LENGTH (FT.) Bevel Dia BOX TOOL JOINT Counterbore Boreback Dia Depth Length Dia Lead Gauge Tong Space Bevel Dia PIN TOOL JOINT Conn SRG Length Width Dia Lead Gauge Tong Space Slip Recess Depth

2 3-5 ALL DIMENSIONS IN INCHES


MPI Elev Area BSR COMMENT

IDENTIFICATION NO

OD

COND

ID

Neck Length

COND

ELEVATOR & SLIP AREA Elev. MPI Recess Slip Depth Area

AM11

OK

30.13

7.13/16

7.7/16

6.1/16

11/16

9.1/16

5.5/16

ACC

41.1/2

OK

2.7/8

7.7/16

AM 06

7.7/16 OK 29.75 7.7/8 7.5/8 OK 30.40 8.1/16 7.11/16 OK 29.85 7.7/8

6.1/16

11/16 8.13/16 5.5/16 ACC 41.1/2 OK

2.7/8

7.9/16

AM 07

6.1/16

11/16 8.13/16 5.1/4 ACC 34.5/16 OK

2.7/8

7.9/16

AM 01

6.1/16

11/16 8.3/4 5.5/16 ACC 41.9/16 OK

2.7/8

7.3/4

7 . 5 / 7 . 9 7 . 2 3 7 . 7 /

3/4

5.15/32

24.13/16

OK

5/32

ACC

ACC

2.97

BSR BELOW SPEC

5.13/32 5 3/4 5.7/16 5 1 5.7/16 5 3/4 19.15/16 23.3/16 19.3/8

OK

1/4

ACC

ACC

2.97

OK

1/4

ACC

ACC

2.97

OK

5/32

ACC

ACC

2.97

NOTE: S/N AM11 WAS FOUND TO BE CLASS 2 DUE TO BSR BELOW DS-1 SPEC.

Max Reqd. Min. Reqd. RECESS DEPTH ( INCHES +1/32",-0)

SD = Seal Damaged TD = Thread Damaged BB = Belled Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Corroded Threads CT = Corroded Threads

RF = Refaced LENGTHS READY FOR USE ACC = Acceptable REJ = Rejected NA = Not Applicable LENGHTS WITH PIN & BOX CONN. REJECTED HB = Hard Band TOTAL LENGTHS INSPECTED LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

3 0 0 0 4

CONNECTIONS REFACED

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS

Member