Tip/Trick#: HWProduct: HWVersion: Category: Topic:

1025 HyperMesh HW8.0SR1andGreater Composites/HyperLaminate ModelingCompositesusingHyperLaminate

ModelingCompositesusingHyperLaminate
HyperLaminateisaHyperMeshmodulethatfacilitatesthecreation,reviewandeditionofcomposite laminates.Itfollowsclassicallaminatedplatetheoryforsimpleinplaneanalysisofcompositelaminates andalsofacilitatesthecreationofDVsandMaterialsforCompositeOptimization ToaccessHyperLaminatewithinHM,goto2DpageHyperLaminatepanelORPropertiespull down:

CreatingaLaminateusingHyperLaminate: Howtocreatethematerialandthepropertiesforthelaminate:[45,90,45,0]swithplythicknessequal to1mmandmaterialpropertiesasshownbelow:

E1=1.3e5Mpa;E2=E3=9650Mpa u12=u13=0.3;u23=0.36 G12=G13=3450Mpa;G23=3100MPa a1=1.0e7mm/mm/oC;a2=a3=18.0e6mm/mm/oC

CreatingOrthotropicMaterial 1. ExpandtheMaterialTreeunderLaminateBrowserandrightclickonMAT8andhitNew 2. KeyintheOrthotropicMaterial(MAT8)detailsaslistedaboveunderDefine/EditMaterial fieldasshownbelow

CreatingCompositeProperty

3. ExpandtheLaminatesTreeunderLaminateBrowserandrightclickonPCOMPandhit New 4. ProvidethenameoftheLaminateandtheStackingSequenceConvention UnderPlylayuporderonecaneitherstackMultipleMaterialinvaryingOrientationsorSame MaterialinvaryingOrientations 5. UnderAdd/UpdatepliesfieldselecttheMaterialcreatedunderStep1,thicknessand Orientation 6. ClickontheAddNewPlytoupdatethePlylayuporder.RepeatStep5withvarying OrientationandThicknesstostackupthepliesindifferentdirectionsasshownbelow TypesofCompositePropertiesavailable PCOMPDefinesthestructureandpropertiesofannplycompositelaminatematerial

PCOMPGDefinesthestructureandpropertiesofacompositelaminatematerial,allowing forglobalplyidentification

VariousOptionsavailableunderLaminateDefinition OutputPlyresultsSettooptionYESwouldactivateSOUTfieldwhichwouldoutput Stressandfailureindexrequestforindividualplies.ThisisavailableforNastranandOptistruct

FailureTheoryOnceoneormoreSOUTfieldsaresettoYESitispossibletoactivatefailure theorycalculation,bycheckingtheFailureTheorycheckbox,selectingatheoryfromthepull downlistanddefininganInterlaminarshearallowablevalue StackingSequenceTotal,Symmetric,Antisymmetric,SymmetricMidlayer,Antisymmetric Midlayer,Repeat CommonThicknessCommonthicknessgiveseveryplyinthelaminatethesamethickness PlylayupOrderThistabledescribesthelaminatefromthebottomply(mostnegativeZ) movingupwards(increasinginpositiveZdirection) CreatingLoadCase 7. ExpandtheHLSLoadcasetreeunderLaminateBrowserandrightclickonInplaneloadsand hitNewasshownbelow

8. KeyintheLoadcasenameandtheLoadvalueinagivendirection.HitApply

UsingHyperLaminatetoCalculatetheLaminateproperties: 9. IntheabovestepswehavesuccessfullydefinedtheCompositeProperties,PlyStacking SequenceandtheLoadcase.OnecanusethesedetailstocalculateLaminateProperties 10. GobacktoLaminatedefinitionunderStep6andClickonAssignLoadcase.Thiswouldopen anewwindowwiththeLoadcasecreatedunderStep8 11. Kindlychecktheoption,reviewtheLoadingvalueandhitApplytoupdatetheloadingvalue

ReviewingLaminateResults:

12. ClickinCalculatebuttonasshownabove.HyperLaminateprovidestheoptiontoreviewthe followingresults: Stiffness/MaterialMatrixResults MidPlaneResults GlobalSystemResults MaterialSystemResults PrincipalResults InvariantResults

You might also like