JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90559 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

AIR WINCH

MWO 16565

Air Winch

SWL: 5000lbs
Date of Next Examination: 18-07-13

LOCATION : RIG FLOOR STBD SIDE


SPECIFICATION: BSMA 31, ASTM E 1444 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

HIGHISLAND VII

We hereby certify that on 19/01/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90560 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

MAN RIDER WINCH

KGO 17650

Man Rider Winch

SWL: 150kg
Date of Next Examination: 18-07-13

LOCATION : RIG FLOOR STBD SIDE


SPECIFICATION: BSMA 31, ASTM E 1444 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

HIGHISLAND VII

We hereby certify that on 19/01/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90561 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

MAN RIDER WINCH

090660

Man Rider Winch

SWL: 150kg
Date of Next Examination: 21-07-13

LOCATION : UNDER CANTILEVER STBD SIDE


SPECIFICATION: BSMA 31 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

HIGHISLAND VII

We hereby certify that on 22/01/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90562 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment

AIR WINCH

MW 020421

Air Winch

SWL: 5000lbs
Date of Next Examination: 21-07-13

LOCATION : MAIN DECK PORT SIDE


SPECIFICATION: BSMA 31 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

HIGHISLAND VII

We hereby certify that on 22/01/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01