Features
NewForeignObjectDebris(FOD) freeandanti-marringcasedesign Lightweight,3.8lbs(1.72Kg) SelectableSpike/SquareWavePulser InterfaceSync(SweepandGate) PRFupto4kHz DisplayPersist DisplayAverage Customerinterchangeabledisplays: -Hi-BriteElectroluminescent -MonochromeLiquidCrystal -ColorLiquidCrystal VGAoutputforheads-updisplayor externalmonitorsandprojectors SingleLi-Ionoperationoroptional remotebatterypackaging 10+hourbatteryruntime PowerLinkTechnology-automatic transducerrecognitionandinstrument set-up
920-072C-EN
Receiver
Frequency Band Tuning Gain Control Control Linear Reject Modes 0.3 to 20 MHz Selectable 0.5, 1, 2.25, 3.5, 5, 10, 15, Wideband (0.3 - 20 MHz), Highpass (3 - 20 MHz) 0 to 110 dB Continuous adjustment in selectable 0.1, 0.2, 0.5, 1.0, 2.0, 6.0, 12 dB 0 to 80% full screen RF, fullwave, half+, half-, fullwave filtered: 10, 5 and 2.25 MHz 0.048 in. to 296 in. (1.23 to 7511 mm) of steel (0.418 to 2560 s) 0.005 inches (0.127 mm) up to the maximum display range setting 1.16 in. to 185 in. (29 to 4.7 mm) of steel (10 to 1600 s) 0.025 to 0.600 in/s (635 to 15240 m/s) horiz. linearity +/ 1% of full screen Selectable maximum; 50 Hz steps, 50 to 4000 Hz, limited by range and pulser settings IP - Gate 1, IF to Gate 1, Gate 1 to Gate 2 Peak or edge Angle beam calculations, curved surface correction 0 to 90 in 0.1 increments Dual flaw gates. Gate 1 time of flight, or amplitude detection, flaw alarm. Gate 2 amplitude detection, flaw alarm or time of flight for echoto-echo mode. Gate 1 selectable IP or IF sync Flashing LEDs and horn Peak amplitude of gated signal in percent of screen height Positive logic requires that a signal cycle of either polarity cross a gate level; negative logic requires that no signal cross a gate level. Segmented, 25 selected points 40 dB, total of gain and DAC limited to 110 dB maximum Selection of multiple curves showing compensation Recall waveform displayed simultaneously with active signal 5000 readings
Calibration
Display Range Measurement Range Delay Velocity Pulse Rate Modes Trigger Modes Trig. Functions Angle
Environmental Ratings
Humidity Classification Altitude Hazardous Area Operation Safe operation in exposure to Class 3 temperature/humidity environments (5 to 95%) Based on Class 2 specifications from the MIL-PRF-28800F Maximum operating and non-operating altitude 15,000 ft (4600 m) Safe operation in explosive atmosphere as defined by Class I, Division 10, 5 and 2.25 MHz 2, Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested using MIL-STD-810E, Method 511.3, Procedure 1 Hollow or filled On command, currently displayed signal is frozen Select and display stored waveform Displays peak amplitude with active signals under peak signal Up to 100 A-scan waveforms may be stored for playback or printout Read-only selection prevents accidental erasure of A-scans 60 Hz Adjustable from 0.1 to 10.0 seconds in 0.1 second steps Selectable 2, 4, 8 and 16 frames Standard Standard Standard Automatic transducer recognition and application setups. Up to 200 test setups (additional 100 setups with A-scan storage) Selectable, spike or square wave 15 to 1000 ns Selectable 150/300 volts 25 ohms, 50 ohms, or 200 ohms Selectable single (pulse echo), dual, or through transmission
Display Features
Signal Screen Freeze Waveform Recall Peak Hold A-scan Storage A-scan Security Update Rate Persistence Display Average
Gates
Functions Indicator Peak Amplitude RF Gates
DAC
Type Gain Display Reference Memory Data Logging
Additional Features
VGA Output RS-232 Analog Output PowerLink Program Storage
Pulser
Type Pulse Width Pulse Voltage Damping Modes
48 Woerd Avenue, Waltham, MA 02453, USA, Tel.: (1) 781-419-3900 12569 Gulf Freeway, Houston, TX 77034, USA, Tel.: (1) 281-922-9300 505, boul. du Parc-Technologique, Qubec (Qubec) G1P 4S9, Tel.: (1) 418-872-1155 1109 78 Ave, Edmonton (Alberta) T6P 1L8
www.olympus-ims.com
info@olympusNDT.com
Sonic_1200M_EN_201010 Printed in the USA Copyright 2010 by Olympus NDT. *All specifications are subject to change without notice. All brands are trademarks or registered trademarks of their respective owners and third party entities.