Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Offered in 4 measurement ranges from 9.

8 (3m) to
32.8 (10m)
Confgurationissimpleviaintegralpushbuttondis-
playmodule
LCDdisplayindicateslevelininches,centimeters
andpercentages
Narrow2or3beamwidthforapplicationswith
limitedmeasurementspace
Fail-safeintelligenceanddiagnosticfeedbackfor
simpletroubleshooting
PVDFtransducerandNEMA4Xpolycarbonate
enclosureforcorrosiveliquids
Automatictemperaturecompensationforaccurate
measurement
EchoSpan LU80/81/83/84 UltrasonicLevelTransmitter

2010FlowlineInc.10500HumboltStreetLosAlamitos,CA90720562.598.3015www.fowline.comDS810511REVA
Features Success
The general purpose ultrasonic level transmitter
provides continuous level measurement up to 32.8
(10m)witha4-20mAsignaloutput,andisconfgured
viaitsintegralpushbuttondisplaymodule.Thisnon-
contactliquidlevelsensorisideallysuitedforcorro-
sive,ultrapure,stickyordirtyliquids,andisbroadly
selected for bulk storage, day tank, lift station and
processtanklevelapplications.
Application
NorthAmerican ther-
moelectric power
plants use 225M
gallons of water per
day in their steam
turbines and cool-
ing towers. Most US
plants are located in
the Coastal and upper Mid West states with easy
accesstoabundantoceanorlakeresources.These
facilities have lots of sumps that collect and pump
transfer water into treatment for reuse or release
to the environment. But sumps capture much more
thanwaterincludinggrease,oil,chemicalandtrash,
thatcoatseverythinginthepit.Here,anEchoSpan
ultrasonicleveltransmitterisinstalledoverthesump
man-way. The patented digital signal processing
technology features an industry leading 3 beam
width that enables installation in close proximity to
theladderandsidewall.
Compatible Products
LI25 LI55 LI90
DataView
LevelController
DataLoop
LevelIndicator
Commander
Multi-TankLevelController
DataPoint
LevelController
LC52
IP
65
EchoSpan LU80/81/83/84 UltrasonicLevelTransmitter

2010FlowlineInc.10500HumboltStreetLosAlamitos,CA90720562.598.3015www.fowline.comDS810511REVA
InstallthelevelsensorusingFlowline 1)
installationfttingsorequivalents.
Specifcations
Range: LU80:4to9.8
(10cmto3m)
LU81:8to18.0
(20cmto5.5m)
LU83:8to26.2
(20cmto8m)
LU84:12to32.8
(30cmto10m)
Accuracy: 0.2%ofrange
Resolution: LU80:0.019(0.5mm)
LU81/83:0.039(1mm)
LU84:0.078(2mm)
Deadband: LU80:4(10cm)
LU81/83:8(20cm)
LU84:12(30cm)
Beamwidth: LU80:2(5cm)
LU81/83/84:3(7.6cm)
Confguration: Pushbutton
Memory: Non-volatile
Displaytype: LCD,6-digit
Displayunits: Inch,cmandpercent
Supplyvoltage: 12-28VDC
Loopresist.: 500Ohms@24VDC
Signaloutput: 4-20mA,two-wire
Signalinvert: 4-20mA,20-4mA
Signalfail-safe: 4mA,20mA,21mA,
22mAorholdlast
Processtemp.: F:-7to140
C:-20to60
Temp.comp.: Automatic
Ambienttemp.: F:-40to160
C:-40to71
Pressure: MWP=30psi(2bar)
Enclosurerating:NEMA4X(IP65)
Encl.material: Polycarbonate
Encl.hardware: Brass&stainless
Enclosurevent: Watertightmembrane
Conduitentrance:Dual,1/2NPT
Trans.material: PVDF
Processmount: LU80:1NPT(1G)
LU81/83/84:2NPT(2G)
Mountgasket: Viton
Classifcation: Generalpurpose
Compliance: CE,RoHS
Notes
Ordering
Dimensions
Fittings
P/N Description
LM52-1400 2 NPT x 1 NPT ( Sch. 40)
LM52-2400 3 NPT x 2 NPT ( Sch. 40)
LM52-2800 3 NPT x 2 NPT ( Sch. 80)
LM52-3800 4 NPT x 2 NPT ( Sch. 80)
LM52-1410 2Socketx1NPT(Sch.40)
LM52-2410 3Socketx2NPT(Sch.40)
LM52-3410 4Socketx2NPT(Sch.40)
LM52-2810 3Socketx2NPT(Sch.80)
LM52-3810 4Socketx2NPT(Sch.80)

LM52-2890 2NPTBulkheadFitting,PVC

LM50-1001-1 1NPTBracket,Polypropylene
LM50-1001 2NPTBracket,Polypropylene
For optimum performance, install the level sensor using the below
recommendedordirectequivalentfttings.
LU8 -51 1
Ordering Notes
1) Install the level sensor using Flowline
installation fittings or equivalents.
Sensor range
0 3m (9.8)
1 5.5m (18.0')
3 8m (26.2')
4
Process mount (1)
0 NPT (US)
6 G (Metric)
EchoSpan Two-Wire Ultrasonic Level Transmitter
LU8 _ Series
EchoSpan
10m (32.8')
LU80SideView TopView LU81/83/84SideView
1
.
9
"

(
4
9
m
m
)
3
.
9
"

(
1
0
0

m
m
)
5.2" (133 mm)
2
.
4
"

(
6
2

m
m
)
1" NPT
(1" G)
1.25"
(32 mm)
4.1" (104 mm)
5
.
2
"

(
1
3
3

m
m
)
4.1" (104 mm)
3.1" (79 mm)
2.8" (69 mm)
3.8" (96 mm)
3
.
4
"

(
8
8

m
m
)
5
.
5
"

(
1
3
8

m
m
)
5.2" (133 mm)
4
.
0
"

(
1
0
0

m
m
)
LU84 Only
2
.
7
"

(
6
9

m
m
) 2" NPT
(2" G)
1
.
9
"

(
4
9
m
m
)
3
.
9
"

(
1
0
0

m
m
)
5.2" (133 mm)
2
.
4
"

(
6
2

m
m
)
1" NPT (1" G)
1.25"
(32 mm)
4.1" (104 mm)
5
.
2
"

(
1
3
3

m
m
)
4.1" (104 mm)
3.1" (79 mm)
2.8" (69 mm)
3.8" (96 mm)
3
.
4
"

(
8
8

m
m
)
5
.
5
"

(
1
3
8

m
m
)
5.2" (133 mm)
4
.
0
"

(
1
0
0

m
m
)
LU84 Only
2
.
7
"

(
6
9

m
m
) 2" NPT
(2" G)
1
.
9
"

(
4
9
m
m
)
3
.
9
"

(
1
0
0

m
m
)
5.2" (133 mm)
2
.
4
"

(
6
2

m
m
)
1" NPT (1" G)
1.25"
(32 mm)

You might also like