Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

grundfos WATER UTILITY PUMPS

Water and wastewater solutions

Grundfos in North America

A formidable team for the future


Founded in 1945 in Bjerringbro, Denmark, Grundfos is a global pump and pumping systems provider with an annual production of more than 16 million units. To support
CHICAGO plans for strategic growth in North America, CORPORATION YEOMANS

with a proud history.


Water industry experience and expertise across the board
Along with our full product range, Grundfos has decades of vast proven experience in developing controllers, motors and monitoring systems for a more complete offering in optimum pumping solutions. This experience ensures a perfect match with hydraulics, motors, electrics and all other mechanical components. Our pumping knowledge drives the technology-advanced pumping solutions and ensures the best possible efficiency point. multistage

The acquisitions enable Grundfos to offer a wide range of solutions for both water and wastewater applications. From

industrial and submersible pumps, to disinfection systems and massive sewage pumping stations, the Grundfos portfolio offers solutions

Grundfos acquired Paco, Peerless and Yeomans


PANTONE 293 C

Blue C 100 M 57 Y 0 K 2

Chicago Corporation, which have addedCHICAGO valuto your individual needs. CORPORATION able resources and competencies to the region.
PANTONE Process Black C Black C 100 M 100 Y 100 K 100

YEOMANS

YEOMANS CHICAGO CORPORATION

1 1

The right solution for every step of the cycle

A dedicated mission

With products as diverse as submersible pumps for raw water intake, complete disinfection systems for water treatment and boosters for water distribution, Grundfos really can supply almost everything you need. For water collection and disposal we offer a variety of wastewater pumping stations pumping stations. In the treatment plant you can rely on Grundfos pumps, mixers and flow makers to keep the process running smoothly.

Around the world millions of Grundfos pumps are on a dedicated mission. To optimize processes, to boost performances and to improve life in general. Grundfos is committed to making a positive contribution to the world that surrounds us. Innovation goes hand in hand with responsibility - and we take pride in constantly pushing the boundaries in pump technology to offer increasingly energy-efficient and sustainable solutions.

Anticipating the future

Grundfos invests 4% of its annual revenue into research and development, with nearly 18,000 employees in 45 countries, dedicated to addressing the challenges of tomorrow, today.

Grundfos offers total pumping solutions on any scale.


Installed in a variety of industries such as:
Fire Protection Municipal Power Industrial Chemical Irrigation

Innovation

Over the years Grundfos has pioneered numerous innovations that have become or are becoming industry standards. Grundfos will continue to be at the forefront in promoting and facilitating energy efficiency and sustainable technology. It is these innovations that will enable the water infrastructure to meet future challenges and regulations. Sourcing treatable water is the first step in any water supply system. Whether your source is groundwater, surface water from rivers and lakes, desalination of seawater or recycled treated water, Grundfos offers total pumping solutions on any scale, from submersibles to dry-pit pumps.

Custom Designs

Engineered designs for unusual applications have always been a specialty for Grundfos. From submersibles to end-suction pumps, no application is beyond our technical expertise. Drawing upon our many years of engineering and manufacturing experience is the best way to solve your difficult application, whether its temperature extremes, or complex configurations.

Water supply solutions


The fluctuation in water levels essentially alters the specifications for a pumping system because these variations change the head. A single speed pump dimensioned to lift from the lowest water level will burn energy dollars when the level is high. A variable speed pump is able to adjust its speed to compensate for changes in water level for the benefit of overall demand.

With Grundfos assistance, you receive a system that will balance intake with changing water levels and demands to ensure against dry-running, cavitation and motor failure.

Constantly developing new and improved ways to meet water and energy challenges

olu Water Supply S

tions
Digital Dosing Pu

DME

mps

e Pu Vertical Turbin

P Peerless VTm p

Horizontal Split

HS

-Case Pump

d Shaft Vertical Enclose p m Pu p m Su

VS

Pressure Boostin

Hydro MPC em
g Syst

Innovative wastewater solutions


Each wastewater pumping solution is typically a one-of-a-kind, configured by Grundfos engineers to meet a specific application and operating condition.

The high flow and resistance to abrasion make the Grundfos wastewater product line well suited to feeding raw surface water to potable water treatment plants.

High-efficiency, solids-handling pumps for wastewater treatment facilities


The S-tube impeller has been developed on the basis of extensive hydraulic experience and know-how. It has been tested through simulations, in laboratory tests and in the field.

With the S-tube, Grundfos sets new standards for wastewater hydraulic design.
Wastewater Solutions
Submersible Gear Dr

AFG
iven Flow Makers

Tube-shaped impelle

S-tube

Submersible Wastewa ter Pump

SL1/SLV

Dedicated Controls

CU 362

Submersible Waste water Pump

S-Pump

A reliable answer to water utility solutions


Grundfos can help you solve your unique needs and challenges, ensuring that water supply, flood control and wastewater facilities meet future demands and regulations. This is achieved by using innovative pump solutions with less energy intensity and more efficiency.

Grundfos offers a proven range of durable, speed-controlled submersible, dry-pit, horizontal multi-stage, end-suction and vertical turbine pumps. These pumps are uniquely designed to deliver cost-effective applications by reacting automatically to changing demands and conditions. To suit each situation, we supply the expertise to ensure pumps and motors are applied correctly.

Additionally, monitoring and control systems further safeguard the reliable flow of water by protecting the pump from dry-running or power supply irregularities.

Proven pumping systems for changing and demanding conditions


Water Utility Facilities

Variable Speed Drive

CUE

Ft. Wayne Hill Treatment Facility, Gwinnett County, GA

Pressure Boosting Sys

Hydro MPC
tem

Vertical Turbine Pump

Peerless VTP

End-Suction Pump

PACO LC

Submersible Pump

SP

10

The SEG range; built tough and versatile - just got better
Grundfos submersible grinder pump solutions cut through everything in their path, now this proven performance has been optimized with the addition of AUTOAdapt. AUTOAdapt combines all previously external sensors, switches and cables into a single unit housed within the pump, capable of adapting automatically to changing conditions within the pit. This Grundfos solution simplifies installation, commissioning and operation, and increases reliability.

Wastewater pumping facilities often have a high percentage of errors in pits with failed float switches or electrodes. With the internal monitoring of the AutoAdapt pumping solution, exposed cables and level switches in submersible sewage pump installations have been eliminated, renewing trust in the safety and reliability of an innovative industry first.

Complexity of traditional installation such as parallel operation or single unit operation, duty assist, duty standby or automatic operation has been eliminated with the Grundfos AUTOAdapt technology. The internal monitoring is installed as a standard, ensuring the pump never runs dry, and is always operational.

Submersible pumps

Submersible Waste water Pump

SL1/SLV

Submersible Waste water Pump

SE/SL

Super Vortex Impeller Pump

SV, S1

11

12

The complete pump portfolio for water supply and wastewater


Product: Product: Dosing Dosing Pumps Pumps WS WS WW Product: Product: WW SRP SRP WW Product: Product: WW AFG, AFV AFG, AFV WS WS WW WW Product: Product: WW Dry Pit Solids Handling Dry Pit Solids Handling Pump Pump Product: Product: WW WW Dry Pit Solids Handling Dry Pit Solids Handling Pump Pump Product: Product: WW WW Severe Duty Recessed Impeller Severe Duty Recessed Impeller Pump Pump
Product types: Product types: Severe DutySevere Cup Type Duty Cup Type Recessed Impeller Recessed Impeller Pump principle: Pump principle: Designed toDesigned Handle Large to Handle Large Abrasive Solids Abrasive Solids Flow, Q: Flow, Q: Max. 4,600 gpm Max.(1045 4,600m3/h) gpm (1045 m3/h) Head, H: Head, H: Max. 150 ft. Max. (45m) 150 ft. (45m) Liquid temperature: Liquid temperature: Max. 250F (120C) Max. 250F (120C) Discharge diameter: Discharge diameter: Max. 8 (200 Max. mm) 8 (200 mm)

WW

Product types: Product types: DME, DDA, DDC, DME,DDE, DDA, DDI, DDC, DMI, DDE, DDI, DMI, DMS, DMX, DMH DMS, DMX, DMH Pump principle: Pump principle: Digital Dosing Digital diaphragm Dosing dosing diaphragm dosing pump/Motor pump/Motor driven diaphragm driven and diaphragm and piston/diaphragm piston/diaphragm dosing pumps dosing pumps Capacity, Q:Capacity, Q: Max. 278 gpm Max. (2 x 278 1150 gpm l/h) (2 x 1150 l/h) Pressure, P: Pressure, P: Max. 2900 psi Max. (200 2900 bar) psi (200 bar) Liquid temperature: Liquid temperature: Max. 122F (50C) Max. 122F (50C)

Product types: Product types: SRP SRP Pump principle: Pump principle: Submersible Submersible gear driven, gear driven, recirculation recirculation pump pump Flow, Q: Flow, Q: Max. 20,605Max. gpm20,605 (1300 l/s) gpm (1300 l/s) Head, H: Head, H: Max. 6 ft (1.8 Max. m) 6 ft (1.8 m) Liquid temperature: Liquid temperature: 32F to 104F 32F (0C to to 104F 40C) (0C to 40C) Discharge diameter: Discharge diameter: DN 300, DN DN 500, 300, DN DN 800 500, DN 800

Product types: Product types: AFG AFG Pump principle: Pump principle: Horizontal and Horizontal vertical and gear vertical driven gear driven owmakers owmakers Axial thrust: Axial thrust: 998-6632 N998-6632 N Liquid temperature: Liquid temperature: 41F to 104F 41F (5C to to 104F 40C) (5C to 40C) Installation Installation depth: depth: Max. 65 ft (20 Max. m) 65 ft (20 m)

Product types: Product types: VPM Vertical VPM Pedestal Vertical Mounted Pedestal Mounted Pump principle: Pump principle: Vertical Pedestal Vertical Mounted Pedestal Mounted Dry Pit Solids-Handling Dry Pit Solids-Handling Pump Pump Flow, Q: Flow, Q: Max. 10,000 Max. gpm10,000 (2,271 m3/h) gpm (2,271 m3/h) Head, H: Head, H: Max. 240 ft.Max. (73m) 240 ft. (73m) Liquid temperature: Liquid temperature: Max. 150F (66C) Max. 150F (66C) Discharge diameter: Discharge diameter: Max. 12 (305 Max. mm) 12 (305 mm)

Product types: Product types: VOS Vertical VOS Open Vertical Shaft Open Shaft Pump principle: Pump principle: Vertical Pedestal Vertical Mounted Pedestal Mounted Dry Pit Solids-Handling Dry Pit Solids-Handling Pump Pump Flow, Q: Flow, Q: Max. 10,000 Max. gpm10,000 (2,271 m3/h) gpm (2,271 m3/h) Head, H: Head, H: Max. 240 ft.Max. (73m) 240 ft. (73m) Liquid temperature: Liquid temperature: Max. 150F (66C) Max. 150F (66C) Discharge diameter: Discharge diameter: Max. 12 (305 Max. mm) 12 (305 mm)

Product: Product: AMD, AMG AMD, AMG

WS

WW WS

Product: Product: WW SV, S SV, S

WW

Product: Product: WW KPL, KWM KPL, KWM

WS

WS WW

WW

Product: Product: WS Suspended VerticalVertical Suspended Sump Sump

WS WW

Product: Product: WW WW High E High ciency, E Solids-handling ciency, Solids-handling Pumps Pumps

Product: Product: WW WW Vertical Vertical Multistage Multistage Centrifugal Centrifugal Pumps Pumps

WW

Product types: Product types: AMD, AMG AMD, AMG Pump principle: Pump principle: Direct and gear Direct driven and mixers gear driven mixers Axial thrust: Axial thrust: 160-3931 N 160-3931 N Liquid temperature: Liquid temperature: 41F to 104F 41F (5C to to 104F 40C) (5C to 40C) Installation Installation depth: depth: Max. 66 ft (20 Max. m)66 ft (20 m)

Product types: Product types: SV, S1, S2, S3SV, S1, S2, S3 Pump principle: Pump principle: Super Vortex Super impeller Vortex or channel impeller or channel impeller pumps impeller pumps Flow, Q: Flow, Q: Max. 28,530Max. gpm 28,530 (1800 l/s) gpm (1800 l/s) Head, H: Head, H: Max. 361 ft (110 Max. m) 361 ft (110 m) Liquid temperature: Liquid temperature: 32F to 104F 32F (0C to to 104F 40C) (0C to 40C) Discharge diameter: Discharge diameter: DN 80 to DN DN 600 80 to DN 600

Product types: Product types: KPL, KWM KPL, KWM Pump principle: Pump principle: Axial and mixed Axialow and pumps mixed ow pumps for high volume for high water volume handling water handling Flow, Q: Flow, Q: Max. 185,000 Max. gpm 185,000 (11,700gpm l/s) (11,700 l/s) Head, H: Head, H: Max. 66 ft (20 Max. m)66 ft (20 m) Liquid temperature: Liquid temperature: Max. 104F (40C) Max. 104F (40C) Discharge diameter: Discharge diameter: Max. 5 ft (1520 Max. mm) 5 ft (1520 mm)

Product types: Product types: Vertical Suspended VerticalScreened-Inlet Suspended Screened-Inlet Wet-Pit Pumps Wet-Pit Pumps Pump principle: Pump principle: Wastewater, Wastewater, drainage, drainage, industrial waste, industrial process waste, waste process waste Capacity, Q:Capacity, Q: Max. 3,000 gpm Max. (681 3,000 m3/hr) gpm (681 m3/hr) Head: Head: Up to 350 ft Up (107 to m) 350 ft (107 m) Liquid temperature: Liquid temperature: Max. 200F (93C) Max. 200F (93C)

Product types: Product types: Type NC/EC/MF Type(Series NC/EC/MF 7100) (Series 7100) Pump principle: Pump principle: Full hydraulic Full coverage, hydraulic vertical coverage, vertical pedestal mounted pedestal with mounted mixed ow with mixed ow and extra capacity and extra impellers capacity impellers Flow, Q: Flow, Q: Max. 140,000 Max. gpm140,000 (32,000 m3/h) gpm (32,000 m3/h) Head, H: Head, H: Max. 260 ft Max. (79 m) 260 ft (79 m) Liquid temperature: Liquid temperature: Max. 250F (120C) Max. 250F (120C) Discharge diameter: Discharge diameter: 4 - 54 (1004 - 135 - 54 mm) (100 - 135 mm)

Product types: Product types: CR, CRI, CRNCR, CRI, CRN Pump principle: Pump principle: Horizontal one-pipe Horizontal system one-pipe suitable system suitable for liquid transfer for liquid in: Washing transfer in: Washing systems, cooling systems, and air cooling conditioning and air conditioning systems, water systems, supply water systems, supply systems, water treatment water systems, treatment resystems, ghter re ghter systems, industrial systems, plants, industrial boiler plants, feed boiler feed systems systems Flow, Q: Flow, Q: Min. 4.5 gpm, Min. Max. 4.5792 gpm, gpm Max. 792 gpm Head, H: Head, H: Max. 995 ft Max. (303 m) 995 ft (303 m) Liquid temperature: Liquid temperature: -4F (-20C) to -4F 250F (-20C) (121C) to 250F (121C) Discharge diameter: Discharge diameter: 1.25 to 6 (31.8 1.25 mm to 6 to(31.8 152 mm) mm to 152 mm)

Product: Product: SEG SEG

WW

Product: Product: WW SL1/SLVSL1/SLV

WW

Product: Product: WW S-Tube S-Tube Channel Channel Impeller Impeller

WW

WW

Product: Product: Hydro MPC BoosterpaQ Hydro MPC BoosterpaQ

WS

Product: Product: WS Vertical Vertical Turbine Turbine Pumps Pumps

WW

Product: Product: WW Horizontal Horizontal Split Case Split Pumps Case Pumps

WW

WW

Product types: Product types: SEG SEG Pump principle: Pump principle: WastewaterWastewater pump with grinder pump with grinder system for pressurized system for pressurized domestic domestic sewage transfer sewage transfer Flow, Q: Flow, Q: Max. 71 gpm Max. (4,5 l/s) 71 gpm (4,5 l/s) Head, H: Head, H: Max. 147 ft (45 Max. m)147 ft (45 m) Liquid temperature: Liquid temperature: 41F to 104F 41F (5C to to 104F 40C) (5C to 40C) Discharge diameter: Discharge diameter: DN 40 to DN DN 5040 to DN 50

Product types: Product types: SL1, SLV SL1, SLV Pump principle: Pump principle: Submersible Submersible wastewaterwastewater pump pump Flow, Q: Flow, Q: Max. 1,395 gpm Max. (88 1,395 l/s)gpm (88 l/s) Head, H: Head, H: Max. 144 ft (44 Max. m) 144 ft (44 m) Liquid temperature: Liquid temperature: 32F to 104F 32F (0C to to 104F 40C) (0C to 40C) Discharge diameter: Discharge diameter: DN 65 to DN DN 150 65 to DN 150

Product types: Product types: S-Tube Channel S-Tube Impeller Channel Impeller Impeller principle: Impeller principle: Impeller for Impeller submersible for submersible pump pump E ciency: World E ciency: class World hydraulic class hydraulic e ciency without e ciency compromising without compromising free passage free passage Free passage: Free Greater passage: freeGreater passage free passage means better means solids better handling solids and handling and greater non-clogging greater non-clogging capabilities capabilities

Product types: Product types: Advanced Packaged Advanced Pump Packaged System Pump System Pump principle: Pump principle: Pressure boosting Pressure in:boosting Water supply in: Water supply systems, Irrigation systems, systems, Irrigation water systems, water treatment, re treatment, protection resystems, protection systems, industrial plants, industrial and HVAC plants, systems and HVAC systems Flow, Q: Flow, Q: Max. 3,600 gpm Max. (6 3,600 pump gpm system) (6 pump system) Head: Head: Up to 500 ftUp (152 tom) 500 ft (152 m) Liquid temperature: Liquid temperature: Min./Max. 32F Min./Max. - 176F32F (0C - 80C) 176F (0C - 80C)

Product types: Product types: VTP VTP Pump principle: Pump principle: Vertical lineshaft Vertical deep lineshaft well pumps deep well pumps for water supply for water fromsupply drilledfrom wellsdrilled wells Flow, Q: Flow, Q: Max. 150,000 Max. gpm 150,000 (34,091gpm m3/hr) (34,091 m3/hr) Head, H: Head, H: Max. 6,930 ft Max. (2,112 6,930 m) ft (2,112 m) Liquid temperature: Liquid temperature: Max. 450F (232C) Max. 450F (232C) Discharge diameter: Discharge diameter: 2 1/2 to 242 (6.36 1/2 to cm 24 to 61 (6.36 cm) cm to 61 cm)

Product types: Product types: Type A, AE, TU, Type TUT, A,KP/KPV AE, TU, TUT, KP/KPV Pump principle: Pump principle: Single stageSingle and multi-stage stage and multi-stage pumps pumps for high volumn for high water volumn supply water supply Flow, Q: Flow, Q: Max. 25,000Max. gpm25,000 (5,676 m3/hr) gpm (5,676 m3/hr) Head, H: Head, H: Max. 675 ft (206 Max.m) 675 ft (206 m) Liquid temperature: Liquid temperature: Max. 250F (121C) Max. 250F (121C) Discharge diameter: Discharge diameter: 2 to 24 (5.08 2 to cm 24 to 61 (5.08 cm) cm to 61 cm)

Product: Product: WW General General Purpose Purpose End Suction End Suction Pumps Pumps

Product: Product: WW HS HS

WS

Product: Product: WS Dedicated Dedicated Controls Controls

WS

WS WW

WW

Product: Product: In-Line Pumps VerticalVertical In-Line Pumps

WW

Product: Product: WW WW Prefabricated Prefabricated Pumping Pumping Stations Stations

Product: Product: WW Motor Protection Motor Protection

WS

WS WW

WW

Product types: Product types: Type C, F, LC/LCV/LF/LFV/OL Type C, F, LC/LCV/LF/LFV/OL Pump principle: Pump principle: Single suction Single pumps suction designed pumps for designed for applicationsapplications of meduim duty of meduim serviceduty service for water and for liquid water hydrocarbons and liquid hydrocarbons in in accordance with accordance the Hydraulic with the Hydraulic Institute (HI) Institute (HI) Flow, Q: Flow, Q: Max. 2,300 gpm Max.(560 2,300 m3/hr) gpm (560 m3/hr) Head, H: Head, H: Max. 400 ft Max. (122 m) 400 ft (122 m) Liquid temperature: Liquid temperature: Min/Max. 32F Min/Max. - 250F 32F (0C to 250F 121C) (0C to 121C)

Product types: Product types: HS HS Pump principle: Pump principle: Single and two-stage Single and horizontal two-stage horizontal split case pumps split case pumps Flow, Q: Flow, Q: 3 /h) Max. 381 gpm Max. (3800 381 m gpm (3800 m 3/h) Head, H: Head, H: Max. 722 ft (220 Max.m) 722 ft (220 m) Liquid temperature: Liquid temperature: 32F to 194F 32F (0C to to 194F 90C) (0C to 90C) Operat. pressure: Operat. pressure: Max. 25 bar Max. 25 bar

Product types: Product types: CU 362 CU 362 Control principle: Control principle: Designed toDesigned optimize to level optimize controllevel control and energy usage and energy in pumping usage in pumping stations stations Pumps supported: Pumps supported: The Dedicated The Controls Dedicated is designed Controls is designed to control and to control monitor and themonitor Grundfos the Grundfos wastewaterwastewater pumps listed pumps below: listed below: SEG, SE, DP, SEG, EF, SL, SE, S DP, EF, SL, S Features and Features benets: and benets: Start/stop of Start/stop wastewater of wastewater pumps by pumps by means of oat means switches, of oat analogue switches, analogue pressure sensors pressure or ultrasonic sensors or sensors ultrasonic sensors Alternating Alternating operation of operation two pumps of two pumps Overow measurement Overow measurement Alarms and Alarms and warnings warnings

Product types: Product types: PV, VL/VLF PV, VL/VLF Pump principle: Pump principle: Centrifugal in-line, Centrifugal pipe in-line, supported, pipe supported, close coupled close pump coupled and motor pump and motor for supplying for water supplying water Flow, Q: Flow, Q: Max. 1,500 gpm Max.(338 1,500 m3/hr) gpm (338 m3/hr) Head, H: Head, H: Max. 400 ft Max. (122 m) 400 ft (122 m) Liquid temperature: Liquid temperature: Max. 250F (121C) Max. 250F (121C)

Product types: Product types: Prefabricated Prefabricated Pumping Stations Pumping Stations Pumping station Pumping principle: station principle: With one orWith two grinder one or two pumps, grinder pumps, auto-coupling, auto-coupling, and wall mounted and wall mounted This auto-coupling This auto-coupling variant is also variant is also designed for designed easy installation for easy installation and and service access service in pumping access in stations pumping stations with heavyduty witheheavyduty uent or sewage e uent or sewage pumps. All components, pumps. All components, e.g. piping, e.g. piping, guide rails, and guide valves rails,are and made valves are made from 2" stainless from 2" steel. stainless steel. Basin Diameter: Basin Diameter: One pump: up One to pump: 4 ft (1.22 up m) to 4 ft (1.22 m) Two pumps: Two up to pumps: 8 ft (2.44 up to m)8 ft (2.44 m) Basin Depth: Basin Depth: 4ft up to 15 ft 4ft (1.22 up to m15 up ft to (1.22 4.57m m) up to 4.57 m)

MP204: MP204: Electronic motor Electronic protection. motorDryprotection. Dryrunning, motor running, temperature, motor temperature, overoverand-under voltage, and-under high voltage, current high current consumption consumption The MP 204 The monitors MP 204 the monitors following the following parameters:parameters: Insulation resistance Insulation before resistance start-up before start-up Temperature Temperature (Tempcon, Pt (Tempcon, sensor and Pt sensor and PTC/thermal PTC/thermal switch) switch) Overload/underload Overload/underload Overvoltage/undervoltage Overvoltage/undervoltage Phase sequence Phase sequence Phase missing Phase missing Power factor Power factor Power consumption Power consumption Harmonic distortion Harmonic distortion Run and start Run capacitor and start (single-phase) capacitor (single-phase) Operating hours Operating and number hours and of starts number of starts

Water Water SupplySupply Products Products


Diversity Diversity characterizes characterizes the Grundfos the Grundfos water supply water range. supply We range. supply We supply reliable and reliable e cient and pumps e cient for pumps almost for every almost aspect every ofaspect water of intake, water intake, treatment treatment processes processes and distribution. and distribution.

Wastewater Wastewater Products Products


Heavy-duty Heavy-duty applications applications are not an are issue notfor anthe issue exible for the and exible robust and Grundfos robust Grundfos wastewater wastewater range. Our range. pump Our systems pumpfor systems wastefor water waste collection water collection and disposal and disposal can handle can the handle toughest the toughest jobs on almost jobs on every almost application every application scale. scale.

13

14

Responsible stewardship and good business


Grundfos is guided by a desire to use technology in innovative ways to support a growing and fast-changing world. We are conscious of the impact our activities can have on people and the environment, and this is precisely why we put sustainability first. From our perspective, sustainability is a healthy mix of responsible stewardship, common sense and good business. To be sure that we have enough clean water tomorrow, we should look to more efficient water use today.

By reducing energy costs on pumping systems, we play our part in conserving resources and making North American water and wastewater solutions more competitive on local and global markets.

L-WU-SL-001 Rev. 09/2012

GRUNDFOS Chicago 3905 Enterprise Court Aurora, IL 60504 Phone: 800-921-7867 Fax: (630) 236-5511

www.grundfos.us
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

You might also like