Different Sources of Oily Wastewater: Treatment by EC

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

Different Sources of oily wastewater: Treatment by EC

Target Pollutant pH, COD mg/L Experimental Setup Reactor Electrode Material: Plexi glass Dimensions: 14 dia*10 cm Volume: 0.4L Shape: Cylindrical Material: Plexi glass Dimensions: 8*8*12.5 cm Volume: 0.5L Domestic wastewater SS mg/L, COD mg/L, Turbidity NTU Material: Plexi glass Dimensions: 6*6.4*16 cm Volume: 0.4L Material: Aluminium Dimensions: 0.3*3*4.5 cm Number: 6 Mode of Expt Batch Operational conditions pH: 2-9 A/cm 2: 25-40 mA D: 0.5-1.25 cm ET: 90 and 120 mins Batch A/cm 2: 8-24 D: 1.6 cm ET: 5,10,20, 30 mins ET: 20 mins Optimum conditions Ph: 7 A/cm 2: 40 mA D: 1 cm ET: 90 mins A/cm 2: 16 mA EC SS: 13.3660 COD: 2402783 O&G: 6.5736 pH: 7.2 SS: 95 COD: 260 SS: 3 COD: 63 O&G: 38 pH: 7 SS: 28.5 COD: 130 70 50 NTU 70 98.8 NR O&G removal reached a rate higher than 80% after a EC time of 10 mins for all current densities. Electrode dissolution for 1m3 is 40 gms. Sekman E et al. 2011. Turkey. Analysis method EC Initial conc pH: 7.6 COD: 4000 Final conc pH: 7 COD: 120 % Rem 97 Sludge Charac NR Remarks Electrode consumption in the range of 0.15 to 0.23 kg/ kg COD removed Ref Saeedi M et al. 2011. Iran.

Source Gas Refinery

Port Waste Reception facilities

SS mg/L, COD mg/L, O&G mg/L

Material: Aluminium (monopolar) Dimensions: 7*12 cm Number: 4 Material: Iron Dimensions: 0.2*6*12 cm

93

81 Sludge production were between 1.5 to 2% in optimal conditions. Inorganic fraction of precipitated solids was 2.6%.

Batch

D: 0.6 cm pH: 3.5 ET: 1-15 mins 0.36A-15V 0.25A-10V 0.12A-5V 0.36A-10V ET: 8-15 mins 0.12A-0.6V

EC

Kurt U et al. 2008. Istanbul

Source Synthetic wastewater

Target Pollutant SS mg/L, Turbidity NTU, COD mg/L

Experimental Setup Reactor Electrode Material: Glass Shape: cylindrical Volume: 2L Stirring: 100 rpm Material: Iron (monopolar) Dimensions: 13*5*0.4 cm Number: 4

Mode of Expt Batch

Operational conditions A/cm 2: 10 V: 30 D: 5cm

Optimum conditions ET: 50 mins A/cm 2: 10 V: 30

Analysis method EC

Initial conc SS: 1400 Turbidity: 491 COD: 1140

Final conc SS: 978.04 Turbidity: 13 COD: 276

% Rem 30.14 97.35 75.79

Sludge Charac NR

Remarks

Ref Othman F et al. 2006. Malaysia

Dairy wastewaters

COD mg/L, O&G mg/L, TSS mg/L, pH

Volume: 0.65L Dimensions: 10*5*0.2 cm Stirring: 100 rpm

Material: Iron (bipolar) Number: 4

Batch

pH: 3.5-10 A/cm 2: 0.3-1.8 D: 2.5 cm T: 298K

pH: 6-7 A/cm 2: 0.6 ET: 1min

EC

COD: 18300 O&G: 4570 TSS: 10200 pH: 6-7.5

COD: 366 O&G: 47.5

98 99

NR

Electrode dissolution is 0.0204 gms/Kg COD removed.

Ayhan I S et al. 2006. Turkey.

Different Methods of Treatment of oily wastewater: Source Target Pollutant Experimental Operational Optimal Setup conditions Conditions