3-Way or More Applications (Multi-location) Remote Devices

Cat. No. VP00R-10, Coordinating Dimmer Remote Cat. No. VP00R-1L, Matching Dimmer Remote Cat. No. VP0SR-10, Coordinating Switch Remote Cat. No. VP0SR-1L, Matching Switch Remote 120VAC, 60Hz

PK-93461-10-00-2A

INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
To be installed and/or used in accordance with appropriate electrical codes and regulations. If you are unsure about any part of these instructions, consult a qualified electrician. To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance. For Hi-lume or Eco-10 (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications. Vizia + remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia + or Vizia rf + devices for multi-location switching.

WARNINGS AND CAUTIONS:


Use only one (1) Vizia + dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level selected at the dimmer. Recommended minimum wall box depth is 2-1/2". Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m).

Tools needed to install your Remote:


Slotted/Phillips Screwdriver Pliers Cutters Electrical Tape Pencil Ruler

Step 2 contd

Step 4b 3-Way Wiring with Coordinating Remote (no LEDs) Application:


NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted.

Step 4d contd WIRING COORDINATING REMOTE:


Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. Remove White insulating label from terminal screw marked "WH". Line Neutral wall box wire to terminal screw marked "WH". Proceed to Step 6.

Changing the color of your Device:


Your device may include color options. To change color of the face proceed as follows: Side Wire Connection Side wire terminals accept #14 AWG solid copper wire only. Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only.

Coordinating Remote

Dimmer

Terminal Screw marked Black (Bk) Terminal Screw marked Yellow/Red (YL/RD)

Bk

Bk

Wiring Matching Remote (wall box with Line Hot connection):


2

3 4
YL/RD
RD

3 4
YL/RD
RD

5/8" (1.6 cm)

Strip Gage (measure bare wire here or use gage on back of the dimmer)

Terminal Screw marked Red (RD)

Coordinating Remote (no LEDs)

Dimmer
Bk hot (Black)
Green Ground

Push in side at tab to release

Line up tabs and press in sides one at a time to attach

not used

INSTALLING YOUR REMOTE


NOTE: Use check boxes when Steps are completed.

Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown.

Wh

Bk
Green Ground

Black RD

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to terminal screw marked "BK" or Black dimmer lead. Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color). This traveler from the remote must go to terminal screw marked "YL/RD" or Yellow/Red control lead. Line Neutral wall box to remote terminal screw marked "WH".

Step 5a

Wiring Dimmer (wall box with Load connection):


Line 120vAC, 60hz

Load White

YL/RD

RD

YL/RD

Step 4a

3-Way Wiring with Matching Remote (w/LEDs) Application:


NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted.
Matching Remote
Terminal Screw marked White (Wh) Additional Neutral Wire
4
Bk

Step 1

WARNING: To avoid fire, shock, or death;

turn off power at circuit breaker or fuse and test that power is off before wiring!

Neutral (White)

Dimmer

/&& /&& /&& /&& /&& /&&

/. /. /. /. /. /.

/&& /&& /&& /&& /&& /&&

/. /. /. /. /. /.

Terminal Screw marked Black (Bk) Terminal Screw marked Yellow/Red (YL/RD)

Bk

2 1 4 3

2 3 1
YL/RD
RD

YL/RD

RD

Step 2

Identifying your wiring application (most common):


NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician.
Matching Remote (w/LEDs)
hot (Black) Wh Bk
Green Ground

Dimmer
Bk
Green Ground

Black Load White

Line 120vAC, 60hz

YL/RD

RD

YL/RD

Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. First Traveler wall box wire to terminal screw marked "RD" or Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".

WIRING DIMMER:

NOTE: Incandescent and Magnetic Low Voltage Connect wires per WIRING DIAGRAM as follows: installations only. Green or bare copper wire in wall box to Green terminal screw or NOTE: Screw terminal dimmer depicted. Green control lead. Dimmer Matching Remote Matching Remote Load wall box wire identified (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall box from Step 2) (tagged) when removing old switch Terminal Terminal Additional Screw marked Screw marked Additional Neutral Wire to terminal screw marked "RD" or White (Wh) White (Wh) Neutral Wire Red control lead. 4 2 3 Terminal First Traveler Line Hot to terminal 1 Terminal 1 Screw marked Screw marked 2 Black (Bk) screw marked "BK" or Black Black (Bk) 5 4 3 control lead. 3 Terminal 4 Terminal Screw marked 1 2 Screw marked Remove Red insulating label from Yellow/Red 5 Yellow/Red (YL/RD) 5 6 (YL/RD) terminal screw marked "YL/RD" or Yellow/Red control lead. Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the terminal screw on the remote Matching Remote Matching Remote Dimmer (w/LEDs) (w/LEDs) marked "YL/RD". Line neutral wall box wire to terminal screw marked "WH" or hot (Black) Bk Wh Wh Bk White control lead. Bk Green Green Green Proceed to Step 6. Black Ground Ground Ground
Bk Bk Bk
YL/RD
RD

4-Way Wiring with Matching Remote (w/LEDs) Application:

YL/RD

RD

YL/RD

RD

Step 4d

3-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:
NOTE: Electronic Low Voltage, Mark 10, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.

Line 120vAC, 60hz

YL/RD

YL/RD

RD

YL/RD

Load White

WIRING COORDINATING REMOTE:

1 3 4 5

1 2 4 5 6

Neutral (White)

3-Way 1. Line or Load (See important instruction below) 2. Neutral 3. Ground 4. First Traveler note color 5. Second Traveler note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot. IMPORTANT:

4-Way 1. First Traveler note color 2. Second Traveler tagged 3. Neutral 4. Ground 5. Third Traveler note color 6. Fourth Traveler tagged NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot.

NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.

Wiring Matching Remote (wall box with Line Hot connection):

For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. For 4-Way applications, note that the old switch being removed will have 4 screws plus a ground screw. Tag the two same color insulated wires with electrical tape.

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to remote terminal screw marked BK or the Black dimmer lead. Second Traveler wall box wire from dimmer to remote terminal screw marked YL/RD (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked YL/RD or the Yellow/Red dimmer lead. Line Neutral wall box to remote terminal screw marked WH.

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". First Traveler wall box wire (note color as above) to terminal screw marked "RD". This traveler from the remote must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead. Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or Yellow/Red dimmer lead. Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Proceed to Step 6.

Neutral (White)

Coordinating Remote
Terminal Screw marked White (WH)
BK

Control
Black

1
White

1 3

2
Green

4
YL/RD
RD

3
Red

Terminal Screw marked Yellow/Red (YL/RD)

NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).

Yellow/Red

4 5

Wiring Matching Remote (4-Way wall box with Line Hot connection):

Coordinating Remote (no LEDs)


WH Black
not used not used
Green Ground

Control
Black Hot (Black)

BK

White
Green Ground

Step 4c

3-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:
NOTE: Electronic Low Voltage, Mark 10, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.
Matching Remote
Terminal Screw marked White (WH)
BK

RD

YL/RD

Red

YL/RD

Load White

Line 120VAC, 60Hz

Wiring Dimmer (wall box with Load connection):

Neutral (White)

Step 3

Preparing and connecting wires:


This remote can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly.

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked RD or the Red dimmer lead. First Traveler Line Hot to dimmer terminal screw marked BK or the Black dimmer lead. Remove Red insulating label from terminal screw marked YL/RD or Yellow/Red dimmer lead. Second Traveler wall box wire (note color as above) to dimmer terminal screw marked YL/RD or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked YL/RD. Proceed to Step 6.

Control
Additional Neutral Wire

Green Black

WIRING CONTROL:
4 2

2 1 4 3
Red White

Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD)

YL/RD

RD

5
5
Yellow/Red

Matching Remote (w/LEDs) Control


Hot (Black)
WH BK
Green Ground

White

Black
Green Ground

Black Load White

Cut (if necessary)

Line 120VAC, 60Hz

YL/RD

Red

Yellow/Red

Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot Connection. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw or Green control lead. Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color). Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". Line Neutral wall box wire to terminal screw marked "WH" or White control lead.

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. First Traveler and Third Traveler wall box wire from dimmer in the 3-way box to remote terminal screw marked "BK" in the 4-way box, and to the terminal screw marked "BK" of the remaining remote in the 3-way box. Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from dimmer in the 3-way box to remote terminal screw marked "YL/RD" in the 4-way box, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. Line Neutral wall box wire to remote terminal screw marked "WH".

Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection):

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler dimmer terminal screw marked "BK" or the Black dimmer lead. Second Traveler wall box wire from dimmer to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. Line Neutral wall box wire to remote terminal screw marked "WH".

Neutral (White)

Step 5a contd

4-Way Wiring with Matching Remote (w/LEDs) Application:

Step 5c

4-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:
NOTE: Electronic Low Voltage, Mark 10, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.

Step 5d contd WIRING COORDINATING REMOTE (4-Way box):

OPERATION
CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.

Wiring Dimmer (3-Way wall box with Load connection):


Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "RD" or the Red dimmer lead. First Traveler Line Hot to dimmer terminal screw marked "BK" or the Black dimmer lead. Remove Red insulating label from terminal screw marked "YL/RD" or the Yellow/ Red dimmer lead. Second Traveler wall box wire (note color as above) to dimmer terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD". Proceed to Step 6.

Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD)

Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. Matching Remote Matching Remote Control (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall Box from Step 2) NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Terminal Terminal Green Additional Screw marked Screw marked Additional Green or bare copper wire in wall box to Green terminal screw. Neutral Wire White (WH) White (WH) Neutral Wire Black Connect First Traveler wall box wire to Third Traveler wall box wire (note wire colors) 4 2 3 to terminal screw marked "RD" of remote in 4-way box, and to terminal screw marked 1 Terminal 1 2 Screw marked White Black (BK) "RD" of the remaining remote in 3-way box. 5 4 3 4 Connect Second Traveler and Fourth Traveler wall box wire (note wire colors) to Terminal 3 Red 2 1 Screw marked 5 Yellow/Red terminal screw marked "YL/RD" of remote in 4-way box, and to terminal screw marked 6 (YL/RD) "YL/RD" of the remaining remote in 3-way box. 5 Yellow/Red This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. Remove White insulating label from terminal screw marked "WH". Matching Remote Matching Remote Control Line Neutral wall box wire to terminal screw marked "WH". (w/LEDs) (w/LEDs)
BK BK
YL/RD
RD

VP00R Dimmer Remote Operation (Device may be unlighted):


NOTE: The lights will turn ON at brightness set on dimmers DIM/BRIGHT bar. The lighting can be switched from either the dimmer or the remote location.
LED Brightness Display

DIM/BRIGHT Bar

YL/RD

RD

Step 5b

4-Way Wiring with Coordinating Remote (no LEDs) Application:


NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted.

Hot (Black)

WH

BK
Green Ground

WH

BK
Green Ground

White
Green Ground

Black

WIRING CONTROL (3-Way box):


Black

Coordinating Remote (3-Way Wall box from Step 2)

Coordinating Remote Dimmer (4-Way Box from Step 2) (3-Way Wall Box from Step 2)
Terminal Screw marked Red (RD)

Line 120VAC, 60Hz

YL/RD

YL/RD

Red

Yellow/Red

Load White

Terminal Screw marked Black (Bk) Terminal Screw marked Yellow/Red (YL/RD)

Bk

Bk

Bk

Neutral (White)
1 2

2 4 1
YL/RD
RD

3 5
YL/RD
RD

3 4
YL/RD
RD

3 4 5

Terminal Screw marked Red (RD)

2 6

Terminal Screw marked Yellow/Red (YL/RD)

NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m).

Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot connection. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw or Green control lead. Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color as above). Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color as above). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". Line Neutral wall box wire to terminal screw marked "WH" or White control lead.

Push Pad

Push Pad (Default settings) Turn ON from OFF position: Tap Lights turn ON to preset level. Press and Hold Lights turn ON to full bright. Turn OFF from ON position: Tap Lights turn OFF. DIM/BRIGHT Bar BRIGHTEN: Press right half of DIM/BRIGHT Bar Lights brighten to desired level. DIM: Press left half of DIM/BRIGHT Bar Lights dim to desired level. If you continue to hold, the lights will DIM to minimum level and then turn OFF. In the event of power outage or interruption the lights will reset to the last level when power is restored.

Locator Light

VP0SR Switch Remote Operation (Device may be unlighted):


The lighting can be switched from either the dimmer or the remote location. Push Pad (Default settings) Turn ON from OFF position: Tap Lights turn ON to preset level. Turn OFF from ON position: Tap Lights turn OFF. In the event of power outage or interruption the lights will reset to the last level when power is restored.
Push Pad Locator Light

Coordinating Remote (no LEDs)


not used

Coordinating Remote (no LEDs)


not used

Wiring Matching Remote (4-Way wall box with Line Hot connection):
Dimmer
Bk
Green Ground

Black

Wh

Bk
Green Ground

Wh

Bk

not used Green Ground

hot (Black)

Load White

RD

YL/RD

RD

YL/RD

RD

YL/RD

Line 120vAC, 60hz

Neutral (White)

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. First Traveler and Third Traveler wall box wire to remote terminal screw marked "BK" in 4-way box, and to terminal screw marked "BK" of the remaining remote in 3-way box. Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from control in 3-way box to remote terminal screw marked "YL/RD" in 4-way box and to terminal screw marked "YL/RD" of the remaining remote in 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. Line Neutral wall box wire to remote terminal screw marked "WH". Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler wall box wire to control terminal screw marked "BK" or Black dimmer lead. Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red dimmer lead. Line Neutral wall box wire to remote terminal screw marked "WH".

WIRING COORDINATING REMOTE (3-Way box):

WIRING COORDINATING REMOTE (4-Way box):

Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection):

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw. First Traveler and Third Traveler wall box wire (note wire colors) to terminal screw marked "RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead, and to the terminal screw marked "RD" of the remaining remote in the 3-way box. Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note wire colors) to terminal screw marked "YL/RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box. Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Remote terminal screw marked "BK" is not used. Use electrical tape to cover.

Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. Remove White insulating label from terminal screw marked "WH". Line Neutral wall box wire to terminal screw marked "WH". Proceed to Step 6.

VP00R-1L ADVANCED PROGRAMMING FEATURES FOR USE WITH VIZIA RF + ONLY


Definition of A Modes
A) LED Options: Sets single LED (default) or LED Bar to display the load status.

Step 6 Testing your Remote prior to completely mounting in wall box:

Program Mode A
To enter Program Mode A: Press and hold the Push Pad and then the right half of the DIM/BRIGHT Bar (^) for 5 seconds until all LEDs blink. Upon releasing the Push Pad Locator LED will blink once per second to indicate Program Mode A, LED Options. To change the LED Options settings, release the Push Pad. This setting will automatically be saved and the device will exit Programming Mode. LED Options Default First toggle LED Brightness/Fan Speed Display Single LED LED Bar

Wiring CONTROL (3-Way wall box with Load connection):

WIRING DIMMER (3-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. First Traveler wall box wire to dimmer terminal screw marked "RD" or Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. Second Traveler wall box wire to dimmer terminal screw marked "YL/RD" or Yellow/ Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".

Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Load wall box wire identified (tagged) when removing old switch to terminal screw marked "RD" or Red control lead. First Traveler Line Hot to terminal screw marked "BK" or Black control lead. Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the terminal screw on the remote marked "YL/RD". Line Neutral wall box wire to terminal screw marked "WH" or White control lead. Proceed to Step 6.

Position all wires to provide room in outlet wall box for device. Ensure that the word "TOP" is facing up on the device strap. Partially screw in mounting screws in wall box mounting hole.

TROUBLESHOOTING
Lights Flickering - Lamp has a bad connection. - Wires not secured firmly under terminal screws of dimmer and/or remote. Light does not turn ON and Locator LED does not turn ON - Circuit breaker or fuse has tripped. - Lamp is burned out. - Lamp Neutral connection is not wired. Intermittent dimmer operation - Minimum load is under 40W. Remote does not operate lights - Ensure that total wire length does not exceed 300 ft (90 m). - Ensure that only Coordinating Remotes are used with Vizia rf + devices

Step 5d

4-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:
NOTE: Electronic Low Voltage, Mark 10, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.

Coordinating Remote (3-Way Wall box from Step 2)


Terminal Screw marked White (WH)

Coordinating Remote (4-Way Box from Step 2)


Terminal Screw marked White (WH)

Control (3-Way Wall Box from Step 2)

Black Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD)
BK

WIRING COORDINATING REMOTE (3-Way box):

3
YL/RD
RD

Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD)

BK

1 3

For additional information, contact Levitons Techline at 1-800-824-3005 or visit Levitons website at www.leviton.com
NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device. Restore power at circuit breaker or fuse. See applicable operation section to ensure dimmer or switch is functioning properly.  If lights do not turn ON, refer to the TROUBLESHOOTING section. Covered by one or more US & Foreign Patents and patents pending Copyright 2007 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved Eco-10 (Eco Series) is a trademark and Hi-lume is a registered trademark of Lutron Electronics Inc.

White
2

4
2
YL/RD
RD

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". First Traveler wall box wire (note color as above) to terminal screw marked "RD". This traveler from the remote must go to the terminal screw on the dimmer marked "RD" or the Red dimmer lead. Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Proceed to Step 6.

4 5

Green
3

Red Yellow/Red
4 5

Coordinating Remote (no LEDs)


WH Black
not used

Coordinating Remote (no LEDs)


WH
not used
Green Ground

Control
White Hot (Black) Black

Step 7 Dimmer Remote Mounting:

FCC COMPLIANCE STATEMENT


This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving Antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help.

Turn off power at circuit breaker or fuse.

BK

not used
Green Ground

BK

Green Ground

RD

YL/RD

not used

RD

YL/RD

Red

YL/RD

Load White

Line 120VAC, 60Hz

Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.

Neutral (White)

Step 8 Restore Power:

Restore power at circuit breaker or fuse. Installation is complete.


PK-93461-10-00-2A

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Levitons only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

You might also like