FXS/FXO Voice Card For AM3440 A/B/C USER'S MANUAL

LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN RD. SCIENCE-BASED INDUSTRIAL PARK HSINCHU, TAIWAN Tel: Fax: +886-3-578-7696 +886-3-578-7695

2010 Loop Telecommunication International, Inc. All rights reserved.


21 JUL 2010 Version 3

TABLE OF CONTENT
1. PRODUCT INTRODUCTION.................................................................................................................... 1 1.1 1.2 1.3 2 2.1 2.2 2.3 2.4 2.4.1 2.4.2 2.5 2.5.1 Description............................................................................................................................... 1 Specification............................................................................................................................. 1 Application Illustration.............................................................................................................. 2 Default Configuration............................................................................................................... 3 RJ11 Pin Assignment............................................................................................................... 4 RJ21X Pin Assignment ............................................................................................................ 5 LED Indication ......................................................................................................................... 6 12 FXS Card ................................................................................................................... 6 12FXO Card .................................................................................................................. 7 Jumper & LED Application..................................................................................................... 10 FXS Card ...................................................................................................................... 10 2.5.1.1 2.5.1.2 2.5.1.3 2.5.2 2.5.2.1 2.5.2.2 2.6 3 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.6 3.1.7 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.6 3.2.7 LED on FXS PCB Board ........................................................................................11 FXS Normal Jumper.............................................................................................. 12 FXS Special Jumper.............................................................................................. 13 LED on FXO PCB Board ....................................................................................... 15 FXO Jumper .......................................................................................................... 15

INSTALLATION ......................................................................................................................................... 3

FXO Card...................................................................................................................... 14

Signaling Bits ......................................................................................................................... 16 FXS Sub-Menu ...................................................................................................................... 17 System Configuration.................................................................................................... 17 FXS Status .................................................................................................................... 19 System Setup................................................................................................................ 20 Diagnostic Test.............................................................................................................. 21 Unit Load Default Configuration.................................................................................... 22 Unit Reset ..................................................................................................................... 22 FXO Sub-Menu...................................................................................................................... 23 System Configuration.................................................................................................... 24 FXO Status.................................................................................................................... 25 System Setup................................................................................................................ 26 Diagnostics Test............................................................................................................ 27 Unit Load Default Configuration.................................................................................... 28 Unit Reset ..................................................................................................................... 28

TERMINAL OPERATION ........................................................................................................................ 17

LIST OF FIGURE
Figure 2-1 RJ11 Connector ............................................................................................................................. 4 Figure 2-2 RJ21X Connector ........................................................................................................................ 5 Figure 2-3 Jumper & LED locations on FXS PCB Board.............................................................................. 10 Figure 2-4 Jumper & LED locations on FXO PCB Board ............................................................................. 14

LIST OF TABLE
Table 2-1 RJ11 Connector Pin Assignment - FXS/ FXO Card ........................................................................ 4 Table 2-2 RJ21X Connector Pin Assignment 24 FXS/ FXO Card ............................................................... 5 Table 2-3 LED on FXS PCB Board: Function and Application.......................................................................11 Table 2-4 Normal Jumper on FXS Card........................................................................................................ 12 Table 2-5 Special Jumper on FXS Card........................................................................................................ 13 Table 2-6 LED on FXO PCB Board: Function and Application ..................................................................... 15 Table 2-7 Jumper on FXO Card .................................................................................................................... 15 Table 2-8 Signaling Bits (Default Setting) - FXS Card .................................................................................. 16 Table 2-9 Signaling Bits (Default Setting) -FXO Card................................................................................... 16

CHAPTER 1 PRODUCT INTRODUCTION

1.

PRODUCT INTRODUCTION

1.1 Description
There are two options for AM3440 FXS/FXO plug-in card: 12FXS/FXO and 24 FXS/FXO. 12FXS/FXO is designed for the single slot, and 24 FXS/FXO is designed for dual slots of Loop-AM3440 series. They both allow voice frequency interfaces to be multiplexed as a 64 Kbps DS0 signal onto a digital network. FXS card provides voice Interfaces connect to telephones. FXO provides connections from telephone lines, either from a central office or from a PBX in RJ11X12 connector (12FXO) or in a single RJ21X (Telco 50pin) connector (24FXO).

1.2 Specification
Voice Card (12FXS,12FXO, 24FXS, 24FXO) 12 FXS/FXO Connector Twelve RJ11 24 FXS/FXO Connector One RJ21X Alarm Conditioning CGA busy after 2.5 seconds of LOS, LOF Encoding A-law or -law, user selectable together for all AC Impedance Balanced 600 or 900 ohms (selectable together for all) Longitudinal Conversion Loss > 46dB Cross talk measure Max -70dBm0 Gain Adjustment -21 to +10 dB / 0.1dB step transmit & receive Signal/ Distortion > 25dB with 1004 Hz, 0dBm input Frequency Response - 0.25 to -1 dB from 300 to 3400 Hz, coincide with ITU-T G.712 Idle Channel Noise Max. 65 dBm0p Variation of Gain 0.5dB FXO Ringing REN 0.5B (AC) Detectable Ringing 25 Vrms Loop Resistance 1800 DC Impedance (ON-HOOK) > 1M DC Impedance (OFF-HOOK) 235 @ 25mA feed 90 @ 100mA feed FXS Loop Feed -48Vdc or -24Vdc with 25mA current limit per port Jumper Selectable: 25mA, 30mA, 35mA FXS signalling Normal / Automatic Ring down FXS Ringing 1 REN at 5K meters per port 16.7Hz, 20Hz, 25Hz, 50Hz, user selectable for all ports 38 to 85 Vrms (sine wave), 76 Vrms for default Ring Voltage 2 sec on 4 sec off, or 1 sec on 2 sec off optional for PLAR Signaling Loop Start, DTMF, pulse, PLAR, Battery Reverse Optional Signaling (for special Ground Start, Metering pulse (12 KHz, 16 KHz), and P( in PLAR mode, PLAR signalling bits order) are programmable. Signaling Bit A,B,C,D Programable bit z All in-band signaling tones are carried transparently by the digitizing process. z Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a switch. z -24Vdc power is for FXS PCB version L and up

CHAPTER 1 PRODUCT INTRODUCTION

1.3

Application Illustration

WAN
PLAR ON

Digital C.O.

Loop-AM3440 FXS Card

E1 / T1
Metering Pulse (12KHz/ 16KHz)

Hot line

CO switch Support Telephones GND-start (Caller ID)

Modem

Pay Phone

WAN

Digital C.O.

Loop-AM3440 FXO
Pulse Detect 12KHz/ 16KHz

E1 / T1

CO switch Support pay phone

Co switch Support GND-start

PABX

CHAPTER 2 INSTALLATION

2 INSTALLATION

2.1 Default Configuration


Item A/ Law Impedance Tx Gain Rx Gain PLAR Ring Cadence Ring Frequency Metering Pulse Metering Pulse Frequency Metering Level PLAR Option/ Range A Law, Law 600 ohm, 900 ohm -21 to +10 dB -21 to +10 dB 2" on 4" off, 1" on 2" off 16.7, 20, 25, 50 Hz On, Off 12 KHz, 16 KHz 1Vrms, 2.4Vrms On, Off Default A Law 600 ohm -3 dB -3 dB 2" on 4" off 20 Hz Off 16 KHz 2.4Vrms Off

Table 2-1 FXS Plug-in card Default Configuration Item A/ Law Impedance Tx Gain Rx Gain Trunk Condition Line Polarity Metering Pulse Frequency Metering Pulse Detect Mode Metering Pulse Decode Level Option/ Range A Law, Law 600 ohm, 900 ohm -21 to +10 dB -21 to +10 dB On hook, Off hook Normal, Reverse 12 KHz, 16 KHz Normal, Packet -19 to -47 dBm Default A Law 600 ohm -3 dB -3 dB On hook Normal 16 KHz Normal -27 dBm

Table 2-2 FXO Plug-in card Default Configuration

CHAPTER 2 INSTALLATION

2.2

RJ11 Pin Assignment


Pin Number 1 2 3 4 5 6 Table 2-3 Line Color Description Unassigned Unassigned Ring lead Tip lead Unassigned Unassigned

Red Green

RJ11 Connector Pin Assignment - FXS/ FXO Card

PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1

Figure 2-1 RJ11 Connector

CHAPTER 2 INSTALLATION

2.3 RJ21X Pin Assignment

LEFT Card RJ21X PIN Line No (teleco 50 PIN) Ring Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 Line 9 Line 10 Line 11 Line 12 1 2 3 4 5 6 7 8 9 10 11 12 Tip 26 27 28 29 30 31 32 33 34 35 36 37

RIGHT Card Line Number

RJ21X PIN (teleco 50PIN) Ring Tip

(L2)
Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 Line 9 Line 10 Line 11 Line 12 13 14 15 16 17 18 19 20 21 22 23 24 38

(L1) TIP PIN 26

Ring
39 40 41 42 43 44 45 46 47 48 49

PIN 1

PIN 25

PIN 50

Table 2-4 RJ21X Connector Pin Assignment 24 FXS/ FXO Card

Figure 2-2 RJ21X Connector FXS, FXO, and MAG Cards

CHAPTER 2 INSTALLATION

2.4 LED Indication


2.4.1 12 FXS Card No Light

{ Light

Show Flashing

Fast Flashing

FXS
A-law U-law

Table 3- 1 LED Indication 12FXS Card LED Indication for Encoding/ Impedance: A-law, -law/ 600 ohm, 900 ohm LED Encoding A-law, -law
Impedance

600 900

METERING PLS

Color 600, 900

Indication

{ {

Green Green Green Green

A-law mode, 600 ohm A-law mode, 900 ohm -law mode, 600 ohm -law mode, 900 ohm

z
{

z z

12K 6 5 4 3 2 1 L12 L11 L10 L9 L8 L7 L6 L5 L4 L3 L2 L1

16K 12 11 10 9 8 7

z
LED

LED Indication for Metering Pulse 12K 16K Color Off Green Green flash 8 Hz Green Green flash 8 Hz Indication Metering Pulse is OFF 12 KHz metering pulse is ON 12 KHz pulse is operating 16 KHz metering is ON 16 KHz metering pulse is operating

z
{

z z z
{
LED

z z

LED Indication for Line 1 to Line 12 Indication Color All LED off Off Green Green flash 1 Hz Green flash 4 Hz Green flash 8 Hz Green flash 16 Hz Red Red flash 1 Hz No input power Tip Lead Open, [Ground Start Mode] Normal Off Hook Ring Lead Ground, [Ground Start Mode] 1. Metering Pulse [Metering Pulse Mode] 2. Battery Reverse Ringing Alarm (1) Alarm at Off Hook status (2) The other party hangs up first on the phone at PLAR ON status L1 to L12

z z
{

Fast Flashing light : When either one of the L1~L12 port is under metering pulse mode (that is, the LED light of that particular port is flashing green light), the metering pulse LED (12K or 16K, depending on its pulse frequency) will also flash in green light at the same time. But if the LED flashes because of battery reverse, the metering pulse LED (12K or 16K) will not have any response. 6

CHAPTER 2 INSTALLATION 2.4.2 12FXO Card

No Light

{ Light

Show Flashing

Fast Flashing

FXO
A-law U-law

LED Indication - 12FXO Card LED Indication for Encoding/ Impedance: A-law, -law/ 600 ohm, 900 ohm LED Encoding A-law, -law
Impedance

600 900

METERING PLS

Color 600, 900

Indication

{ {

Green Green Green Green

A-law mode, 600 ohm A-law mode, 900 ohm -law mode, 600 ohm -law mode, 900 ohm

z
{

z z

12K 6 5 4 3 2 1 L12

16K 12 11 10 9 8 7

z
LED

LED Indication for Metering Pulse 12K 16K Color Off Green Green flash 8 Hz Green Green flash 8 Hz Indication Metering Pulse is OFF 12 KHz metering is ON 12 KHz pulse is operating 16 KHz metering is ON 16 KHz pulse is operating

L11 L10 L9 L8 L7 L6 L5 L4 L3 L2 L1

z
{

z z z
{

z z

LED Indication for Line 1 to Line 12 LED L1 to L12 Color Off Green Green flash 1 Hz Green flash 4 Hz Green flash 8 Hz Green flash 16 Hz Red Red flash 1 Hz Tip Lead Open or Line Empty, [Ground Start Mode] Normal Off Hook Ring Lead Ground, [Ground Start Mode] 1. Metering Pulse [Metering Pulse Mode] 2. Battery Reverse Ringing Alarm Alarm at Off Hook status Indication

z
{

Fast Flashing light : When either one of the L1~L12 port is under metering pulse mode (that is, the LED light of that particular port is flashing green light), the metering pulse LED (12K or 16K, depending on its pulse frequency) will also flash in green light at the same time. But if the LED flashes because of battery reverse, the metering pulse LED (12K or 16K) will not have any response.

CHAPTER 2 INSTALLATION Table 3- 2 LED Indication 24FXS Plug-in card

No Light

{ Light

Show Flashing

Fast Flashing

LED Indication for Encoding/ Impedance: A-law, -law/ 600 ohm, 900 ohm LED Encoding Impedance A-law -law 600 900 Color Indication

LEFT

RIGHT

FXS
A-law U-law

FXS
600 900
A-law U-law

600 900

METERING PLS

METERING PLS

{ {

Green Green Green Green

A-law mode, 600 ohm A-law mode, 900 ohm -law mode, 600 ohm -law mode, 900 ohm

12K 6 5 4 3 2 1

16K 12 11 10 9 8 7

12K 6 5 4 3 2 1

16K 12 11 10 9 8 7

z
{

z z

LED Indication for LEFT /RIGHT Side Plug-in card Metering Pulse LED 12K 16K Color Off Green Green flash 8 Hz Green Green flash 8 Hz Indication Metering Pulse is OFF 12 KHz metering is ON 12 KHz pulse is operating 16 KHz metering is ON 16 KHz pulse is operating
R I G H T L E F T

RING

TIP

z
{

z z z
{

z z

12 1

LED Indication for LEFT /RIGHT Side Plug-in card from Line 1 to Line 12 LED L1 to L12 Color All LED off Off Green Green flash 1 Hz Green flash 4 Hz Green flash 8 Hz Green flash 32 Hz Red Red flash 1 Hz No input power Tip Lead Open, [Ground Start Mode] Normal Off Hook Ring Lead Ground, [Ground Start Mode] 1. Metering Pulse [Metering Pulse Mode] 2. Battery Reverse Ringing Alarm 3. Alarm at Off Hook status The other party hangs up first on the phone at PLAR ON status Indication

12

z z
{

Fast Flashing light : When either one of the 1~12 port is under metering pulse mode (that is, the LED light of that particular port is flashing green light), the metering pulse LED (12K or 16K, depending on its pulse frequency) will also flash in green light at the same time. But if the LED flashes because of battery reverse, the metering pulse LED (12K or 16K) will not have any response. 8

CHAPTER 2 INSTALLATION

Table 3- 3 LED Indication - 24FXO Plug-in card

No Light

{ Light

Show Flashing

Fast Flashing
LEFT RIGHT

LED Indication for Encoding/ Impedance: A-law, -law/ 600 ohm, 900 ohm LED Encoding Impedance A-law -law 600 900 Color

FXO
A-law U-law

FXO
600 900
A-law U-law

600 900

Indication

METERING PLS

METERING PLS

12K 6 5 4 3 2 1

16K 12 11 10 9 8 7

12K 6 5 4 3 2 1

16K 12 11 10 9 8 7

{ {

Green Green Green Green

A-law mode, 600 ohm A-law mode, 900 ohm -law mode, 600 ohm -law mode, 900 ohm

z
{

z z

RING

TIP

LED Indication for LEFT /RIGHT Side Plug-in card Metering Pulse LED 12K 16K Color Off Green Green flash 8 Hz Green Green flash 8 Hz Indication
1

z
{

z z z
{

Metering Pulse is OFF 12 KHz metering is ON 12 KHz pulse is operating 16 KHz metering is ON 16 KHz pulse is operating

L E F T

12 1
R I G H T

z z

LED Indication for LEFT /RIGHT Side Plug-in card from Line 1 to Line 12 LED L1 to L12 Color Off Green Green flash 1 Hz Green flash 4 Hz Green flash 8 Hz Green flash 32 Hz Red Red flash 1 Hz Tip Lead Open or Line Empty, [Ground Start Mode] Normal Off Hook Ring Lead Ground, [Ground Start Mode] 1. Metering Pulse [Metering Pulse Mode] 2. Battery Reverse Ringing Alarm Alarm at Off Hook status Indication

12

z
{

Fast Flashing light : When either one of the 1~12 port is under metering pulse mode (that is, the LED light of that particular port is flashing green light), the metering pulse LED (12K or 16K, depending on its pulse frequency) will also flash in green light at the same time. But if the LED flashes because of battery reverse, the metering pulse LED (12K or 16K) will not have any response. 9

CHAPTER 2 INSTALLATION

2.5 Jumper & LED Application

2.5.1

FXS Card

Figure 2-3 Jumper & LED locations on FXS PCB Board

10

CHAPTER 2 INSTALLATION

2.5.1.1

LED on FXS PCB Board

LD1, LD3 are LED lights for showing each steps under device boot procedure. See below table for the color of the lights and the status they represent.

Steps under boot procedure Card plug-in Run flash Test RAM ok, check bank Load firmware to RAM Enter firmware Load FPGA FPGA ok, running RAM or Flash fail FPGA or NW 1034 or FX 461 fail

Time (sec) 0 1 4 15 17 27 32 32 32

LD1 Red Dark Red Dark Red Flash Red Dark Red -

LD3 Red Dark Dark Red Red Flash Red Dark Red

The function and application of other LED lights are listed below: LED FUSE Color Normal Break Description The input power of 12 FXS card is under 80Vac The input power of 12 FXS card is over 80Vac. The LED lights (L1~L12) on the front panel will also shut down at the same time. LD2 Red Off LD4 Green Off Ring Generator on Ring Generator off Input power under normal condition:-48V or -24V. FUSE under normal operation FUSE breaks, no input power

Table 2-5 LED on FXS PCB Board: Function and Application

11

CHAPTER 2 INSTALLATION

2.5.1.2

FXS Normal Jumper

Number JP1

Name P

Jumper Settings

Function PLAR bit set to OFF-Hook llll, Ring llll PLAR bit set to user programmable

Default

JP2 Note: Only available for 12FXS-GM

Model

Normal (12FXS) Metering pulse (12FXS-M) Ground Start (12FXS-GS) Metering + Ground (12FXS-GM)

or
J3 BANK SW Enable flash download to work under its default firmware bank Switch the flash download working firmware bank (Bank 1, Bank 2) J9 Ringer Ringer Output Voltage: 76 VAC

or
Ringer Output Voltage: 64 VAC Ringer Output Voltage: 86 VAC

: Unjumpered : Jumpered
Table 2-6 Normal Jumper on FXS Card

12

CHAPTER 2 INSTALLATION

2.5.1.3

FXS Special Jumper

Number J8

Name S1

Jumper Settings

Function FXS output line current: 25mA

Default

FXS output line current: 30mA

FXS output line current: 35mA

J7

S4

Disable alarm tone Enable alarm tone

J6

S5

Set ring generator to automatic (power saver) mode Set ring generator to non-stop mode for special use (i.e. double ring tone)

: Unjumpered : Jumpered
Table 2-7 Special Jumper on FXS Card

13

CHAPTER 2 INSTALLATION

2.5.2

FXO Card

Figure 2-4 Jumper & LED locations on FXO PCB Board

14

CHAPTER 2 INSTALLATION

2.5.2.1

LED on FXO PCB Board

LD1, LD2 are LED lights for showing each steps under device boot procedure. See below table for the color of the lights and the status they represent. Steps under boot procedure Card plug-in Run flash Test RAM ok, check bank Load firmware to RAM Enter firmware Load FPGA FPGA ok, running RAM or Flash fail FPGA or NW 1034 or FX 461 fail Time (sec) 0 1 4 15 17 27 32 32 32 LD1 Red Dark Red Dark Red Flash Red Dark Red LD2 Red Dark Dark Red Red Flash Red Dark Red

Table 2-8 LED on FXO PCB Board: Function and Application 2.5.2.2 FXO Jumper

Number J9 Only available for 12FXO-GM

Name Model

Jumper Settings

Function Normal (12FXO) Metering pulse (12FXO-M) Ground Start (12FXO-GS) Metering + Ground (12FXO-GM)

Default

or
J3 BANK SW Bank switch unavailable Switch the current firmware bank to the other

: Unjumpered : Jumpered
Table 2-9 Jumper on FXO Card

15

CHAPTER 2 INSTALLATION

2.6

Signaling Bits

PLAR OFF FXS/FXS-P TX On hook Off hook No ring Ring on Battery Reverse Metering Pulse Tip lead open Ring lead GND OOS-Alarm A 0 1 B C D A 1 0 1 1 0 1 1 0 0 0 1 0 0 1 * B C D A 0 1 * * * 0 * * 1 0 0 1 0 0 1 1 1 * * *

FXS/FXS-P PLAR ON FXS RX B C D A 0 1 * * * 1 1 1 TX B C D A 1 0 1 1 0 1 1 0 B C D A 1 0 1 1 1 1 0 1 FXS-P RX B C D

* 0

* *

* *

Table 2-10 Signaling Bits (Default Setting) - FXS Card

FXO TX A B C D A 0 1 B * 1 RX C * * D * *

On hook Off hook No ring 0 1 0 1 Ring On 0 0 0 1 Battery Reverse 0 1 0 0 Metering Pulse 0 1 0 0 Tip Lead open 1 1 1 1 Ring lead GND 0 0 0 1 OOS-Alarm * * * * Table 2-11 Signaling Bits (Default Setting) -FXO Card

16

CHAPTER 3 TERMINAL OPERATION

3 TERMINAL OPERATION
3.1 FXS Sub-Menu
Under the Controller Menu, press U to choose a slot for the FXS port. Then the following screen will show.
SLOT 12 FX S Vers ion === Por t M enu === : SW V3 .01. 01 05/ 07/2 009 , HW V er. L 1 6:42 :00 05 /19/ 200 9

[DIS PLA Y] C -> Sy ste m Co nfi gur atio n I -> FX S S tatu s

[SET UP] S -> Sy ste m Se tup T -> Di agn osti c T est G -> Up gra de F irm war e

[LOG ] U -> Ch oos e Ot her Sl ot F -> Lo g O ff O -> Lo g O n E -> Re tur n to Ma in Menu

[MIS C] Y -> Un it Load De fau lt C onf ig Z -> Un it Rese t

>>SP ACE ba r to re fre sh o r e nte r a com man d == =>

3.1.1

System Configuration

Press "C" to view the system configuration as below. E X AM P LE 1: When Metering Pulse is not available, the screen will show as below. For FXS Normal mode PCB H/W Version F or over:
SLOT 12 FX S A/u- Law : A L1 TxGa in: -3 .0 RxGa in: -3 .0 === S yste m C onf igur ati on === 1 1:35 :27 11 /11/ 200 8 Imp e danc e : 60 0 oh m L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ( -2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BATT -REV : 0 1 0 0 RIN G-GN D : ( NA ) OOS- A LARM : * * * * PLAR OF F HOO K : 1 1 1 1 ( fixe d) TIP- OPEN : ( N A ) PLAR RI N G ON : 1 1 1 1 (f ixed ) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : ( NA ) Mete rin g F req. : ( NA ) Mete rin g L evel : ( NA ) PLAR L1 OFF L2 O FF L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 O FF L11 OFF L 12 O FF

<< E SC key to ret urn to pre vio us m enu , S PACE ba r t o re fre sh >>

17

CHAPTER 3 TERMINAL OPERATION For FXS-P mode PCB H/W Version F or over:
SLOT 12 FX S === Sys tem Set up === 10 :07 :51 11/ 11/ 200 8 ARRO W K EYS : CU RSO R M OVE, TA B: ROLL OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BAT T-RE V & PL S ON : 0 1 0 0 RIN G-GN D : ( NA ) OO S-A LARM : * * * * PLAR OF F HOO K : 1 1 0 1 ( =OFF HO OK) TIP- OPEN : ( N A ) PLAR RI N G ON : 0 0 * * (= RING ON ) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : (NA) Mete rin g F req. : (NA) Mete rin g L evel : (NA) PLAR L1 L2 OFF O FF ALL PLA R = L1 : N O L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 O FF L11 OFF L 12 O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

Note : 1. FXS-P New mode: put a jumper to JP1 for H/W Version H or over Old mode: add a R367 resister in the back of the PCB for H/W Version 2. FXS-P mode PLAR bit can programmable when PLAR turns on 3. Regarding US ring back signaling for the FXS Card, PLAR generates a 440/480Hz ring-back tone (H/W version H or over). E X AM P LE 2: When Metering Pulse and Ground start is available, the screen will show as below. For FXS-GM mode PCB H/W Version H or over:
SLOT 12 FXS === System Configuration === 10:07:51 11/11/2008 ARRO W K EYS : CU RSO R M OVE, TA B: ROLL OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BAT T-RE V & PL S ON : 0 1 0 0 RIN G-GN D : 0 0 0 1 OOS -A LARM : ( N A ) PLAR OF F HOO K : 1 1 1 1 ( fixe d) TI P- OPEN : 1 1 1 1 PLAR RI N G ON : 1 1 1 1 (f ixed ) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : OFF Mete rin g F req. : 16 K Hz Mete rin g L evel : 2.4V rms PLAR L1 L2 OFF O FF ALL PLA R = L1 : N O L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 O FF L11 OFF L 12 O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

18

CHAPTER 3 TERMINAL OPERATION For FXS-GMP mode PCB H/W Version H or over:
SLOT 12 FX S === Sys tem Set up === 10 :07 :51 11/ 11/ 200 8 ARRO W K EYS : CU RSO R M OVE, TA B: ROLL OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BAT T-RE V & PL S ON : 0 1 0 0 RIN G-GN D : 0 0 0 1 OO S-A LARM : ( N A ) PLAR OF F HOO K : 1 1 0 1 ( =OFF HO OK) TIP- OPEN : 1 1 1 1 PLAR RI N G ON : 0 0 * * (= RING ON ) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : OFF Mete rin g F req. : 16 K Hz Mete rin g L evel : 2.4V rms PLAR L1 L2 OFF O FF ALL PLA R = L1 : N O L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 L11 L 12 O FF OFF O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

Note : 1. FXS-GM mode with metering pulse 12KHz/16KHz and Ground start. 2. Metering Pulse Level New mode: support level 2.4Vrms or 1 Vrms for H/W Version H or over. Old mode: support level 0dBm or 24dBm for H/W Version F or below. 3. FXS-GMP New mode: put a jumper for JP1 for H/W Version H or over. Than the PLAR bit can be programmable when PLAR is turned on. Old mode: add a R367 resister in the back of the PCB for H/W Version F. Then, the PLAR bit can be programmable when PLAR is turned on. 3.1.2 FXS Status

Press "I" from the Port Menu to view the FXS status.
SLOT 12 FX S === FXS St atus == = 1 1:38 :07 11 /11/ 200 8

1.O FF HOO K 2.M ETE RIN G PU LSE 3.T IP- OPE N 4.R ING -GN D 5.P LAR ON 6.R ING ING 7.A LAR M O N

: : : : : : :

L1 NA NA NA L1 L1 L1

L2 NA NA NA L2 L2 L2

L3 NA NA NA L3 L3 L3

L4 NA NA NA L4 L4 L4

L5 NA NA NA L5 L5 L5

L6 NA NA NA L6 L6 L6

L7 NA NA NA L7 L7 L7

L8 NA NA NA L8 L8 L8

L9 NA NA NA L9 L9 L9

L1 0 NA NA NA L1 0 L1 0 L1 0

L 11 NA NA NA L 11 L 11 L 11

L1 2 NA NA NA L1 2 L1 2 L1 2

<< p res s E SC k ey to retu rn to main me nu, SPA CE key to ref res h >>

19

CHAPTER 3 TERMINAL OPERATION

3.1.3

System Setup

Press "S" from the Port Menu to setup system configuration. Use arrow keys to move cursor and TAB key to roll options. NOTE1: ALL PLAR = L1: YES , means that PLAR setting of L2 to L12 are same as L1. ALL PLAR = L1: NO , means that PLAR setting of L2 to L12 are different from L1.

The option, OOS-ALARM , is only available for new E1 and new T1 interfaces. NOTE2: E X AM P LE 1: When Metering Pulse is not available, the screen will show as below. For FXS-GM mode PCB H/W Version H or over:
SLOT 12 FX S === S yst em Setu p = == 16:51 :46 11 /11/ 200 8 ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 - 3.0 - 3.0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 - 3.0 - 3.0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BATT -REV : 0 1 0 0 RIN G-GN D : ( NA ) OOS- A LARM : * * * * PLAR OF F HOO K : 1 1 1 1 ( fixe d) TIP- OPEN : ( N A ) PLAR RI N G ON : 1 1 1 1 (f ixed ) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : ( NA ) Mete rin g F req. : ( NA ) Mete rin g L evel : ( NA ) PLAR L1 L2 OFF O FF ALL PLA R = L1 : N O L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 O FF L11 OFF L 12 O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

For FXS-GMP mode PCB H/W Version H or over:


SLOT 12 FX S === S yst em Setu p = == 16:51 :46 11 /11/ 200 8 ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 - 3.0 - 3.0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 - 3.0 - 3.0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign ali ng B it A B C D Rx S i gnal ing Bi t A B C D ON HOO K : 0 1 0 1 RIN G ON : 0 0 * * OFF HOO K : 1 1 0 1 BATT -REV : 0 1 0 0 RIN G-GN D : ( NA ) OOS- A LARM : (NA ) PLAR OF F HOO K : 1 1 1 1 ( =OFF HO OK) TIP- OPE N : 1 1 1 1 PLAR RI N G ON : 0 0 * * (=R ING ON) PLAR Ri ng Cade nce : 2"ON ,4" OFF ( * fo r d on' t ca re ) Ring Fre q uenc y : 20 Hz Mete rin g P ulse : OFF Mete rin g F req. : 16 K HZ Mete rin g L evel : 2.4 Vrm s PLAR L1 L2 OFF O FF ALL PLA R = L1 : N O L3 OFF L4 O FF L5 OFF L6 O FF L7 OFF L8 O FF L9 OFF L1 0 O FF L11 OFF L 12 O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

20

CHAPTER 3 TERMINAL OPERATION Note : 1. FXS-GM mode with metering pulse 12KHz/16KHz and Ground start. 2. FXS-GMP New mode: put a jumper to JP1 for H/W Version H or over. Than the PLAR bit can be programmable when PLAR turns on. Old mode: add a R367 resister in the back of the PCB for H/W Version F. Then, the PLAR bit can be programmable when PLAR is turns on. 3. Regarding US ring back signaling for the FXS Card, PLAR generates a 440/480Hz ring-back tone (H/W version H or over) 3.1.4 Diagnostic Test

Press T from the Port Menu to do diagnostic test. Use TAB key to select the desired option. The current selection will be highlighted by an asterisk (*).
SLOT 12 FX S == = F XS D iag nos tic Tes t = == 1 1:36 :17 11 /11/ 200 8

*1. RIN G T EST

2. BAT TER Y RE VER SE TEST

- ST ATU S : << p res s E SC k ey to retu rn to main me nu >>

Press ENTER after done the selection. As the following example shows, the system is doing RING TEST.
SLOT 12 FX S == = F XS D iag nos tic Tes t = == 1 1:36 :17 11 /11/ 200 8

*1. RIN G T EST

2. BAT TER Y RE VER SE TEST

- ST ATU S :

Re mai n 1 2 se con ds.

<< p res s E SC k ey to retu rn to main me nu >>

21

CHAPTER 3 TERMINAL OPERATION

3.1.5 Upgrade Firmw are Press G from the Port Menu to start your flash download. Key in the server IP and firmware file name. Then, press Enter to start the download.
LOOP AM 344 0-A = == Down loa d F irmw are == = 1 6:42 :24 05 /19/ 200 9 ARRO W K EYS : CU RSO R M OVE, Pl eas e In put : n nn.n nn. nnn .nnn , B ACK SPAC E t o e dit

Bank 1 Fir mwar e V er. : V 3.0 1.0 1 05 /07 /20 09 Bank 2 Fir mwar e V er. : V 3.0 1.0 1 05 /07 /20 09 Work ing Fi rmwa re Ban k: 2 TFTP Se rve r IP Firm war e F ile Nam e : 0 10. 003 .013 .01 0 :

(Go od) (Go od)

<< p res s E SC k ey to retu rn to main me nu >>

3.1.6

Unit Load Default Configuration

Press Y from Port Menu to return the default. Then press Y or N to confirm the selection.
SLOT 12 FX S === Uni t M enu === 1 1:36 :39 11 /11/ 200 8

Load de fau lt - ar e y ou s ure (Y /N)?

3.1.7

Unit Reset

Press Z from Port Menu to reset the unit. Then press Y or N to confirm the selection.
SLOT 12 FX S === Uni t M enu === 1 1:36 :39 11 /11/ 200 8

Rese t - ar e yo u s ure ? [ Y/N ]

If users enter "Y" to confirm the reset, the system will request users to enter the password, LOOP, then press ENTER.
SLOT 12 FX S === Uni t M enu === 1 1:36 :39 11 /11/ 200 8

==>> En ter pas swo rd :

22

CHAPTER 3 TERMINAL OPERATION

3.2

FXO Sub-Menu

Under the Controller Menu, press U to choose a slot for the FXO port. Then the following screen will show.
SLOT 1 Vers ion FXO === Por t M enu === : SW V2 .01. 01 05/ 07/2 009 , HW V er. G 16:32 :48 05 /19/ 200 9

[DIS PLA Y] C -> Sy ste m Co nfi gur atio n I -> FX O S tatu s

[SET UP] S -> Sy s tem Set up T -> Di ag nost ic Tes t G -> Up gra de F irm war e

[LOG ] U -> Ch oos e Ot her Sl ot F -> Lo g O ff O -> Lo g O n E -> Re tur n to Ma in Menu

[MIS C] Y -> Un it Load De fau lt C onf ig Z -> Un it Rese t

>>SP ACE ba r to re fre sh o r e nte r a com man d == =>

23

CHAPTER 3 TERMINAL OPERATION

3.2.1

System Configuration Under the above menu, press "C" to view the system configuration as below. E X AM P LE 1: When Metering Pulse is not available, the screen will show as below.
SLOT 1 FXO A/u- Law : A L1 TxGa in: -3 .0 RxGa in: -3 .0 === Sy stem Co nfi gura tio n = == 16:3 2:4 8 0 5/19 /20 09

Imp e danc e : 60 0 oh m L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ( -2 1 ~ +10 in dB ) Tx S ign al ing Bit A B C D Rx S ign a ling Bi t A B C D RING I NG : 0 0 0 1 OFF-H OOK : 1 1 * * NO R I NG : 0 1 0 1 OO S-AL ARM : * * * * BATT -R EV : 0 1 0 0 RING- GND : 0 0 0 1 PULS E ON : 0 1 0 0 ( * for d on't ca re ) TIP- OP EN : 1 1 1 1 Trun k C ond itio n : ON -HOO K Line Po lar ity : NO RMAL Mete rin g P ulse Fr equ ency : 1 6 KH z Mete rin g P ulse De tec t Mo de : N ORMA L Mini mum Pu lse Dec ode Lev el ( - 19 ~ -4 7 ) L1 L2 L3 L4 L5 L6 -27 - 27 -2 7 - 27 -2 7 - 27

L7 -2 7

L8 - 27

L9 -2 7

L 10 - 27

L1 1 -2 7

L 12 - 27 ( dBm )

<< E SC key to ret urn to pre vio us m enu , S PACE ba r t o re fre sh >>

EXAMPLE 2: When Metering Pulse is available, the screen will show as below.
SLOT 1 FXO A/u- Law : A L1 TxGa in: -3 .0 RxGa in: -3 .0 === Sy stem Co nfi gura tio n = == 1 6:32 :48 05 /19/ 200 9

Imp e danc e : 60 0 oh m L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ( -2 1 ~ +10 in dB ) Tx S ign al ing Bit A B C D Rx S ign a ling Bi t A B C D RING I NG : 0 0 0 1 OFF-H OOK : 1 1 * * NO R I NG : 0 1 0 1 OO S-AL ARM : * * * * BATT -R EV : 0 1 0 0 RING- GND : 0 0 0 1 PULS E ON : 0 1 0 0 ( * for d on't ca re ) TIP- OP EN : 1 1 1 1 Trun k C ond itio n : ON -HOO K Line Po lar ity : NO RMAL Mete rin g P ulse Fr equ ency : 1 6 KH z Mete rin g P ulse De tec t Mo de : N ORMA L Mini mum Pu lse Dec ode Lev el ( - 19 ~ -4 7 ) L1 L2 L3 L4 L5 L6 -27 - 27 -2 7 - 27 -2 7 - 27

L7 -2 7

L8 - 27

L9 -2 7

L 10 - 27

L1 1 -2 7

L 12 - 27 ( dBm )

<< E SC key to ret urn to pre vio us m enu , S PACE ba r t o re fre sh >>

Note: * represents dont care. If OOS-Alarm is set as ****, it means the OOS alarm function is now disabled. If Ring-GND is set as ****, it means the ring-GND function is now disabled. If OFF-HOOK status is set as ****, it means the OFF-HOOK function is now disabled. If the software version is V2.01.03 or after and the OFF-HOOK status is set as ****, it means all twelve ports are set as OFF-HOOK.

24

CHAPTER 3 TERMINAL OPERATION 3.2.2 FXO Status Under FXO Port Menu, press I to display status of FXO interface, then the screen will show as below. E X AM P LE 1: When Ground Start is not available, the system will show up NO AVAILABLE for TIP-OPEN and RING-GND. When Metering Pulse is not available, the system will show up NO AVAILABLE for PULSE ON.
=== F XO Sta tus === 16 :32: 48 05/ 19/2 009

SLOT 1 FXO

1.RI NGI NG 2.OF F-H OO K 3.TI P-O PE N 4.RI NG- GN D 5.BA TT- RE V 6.PU LSE O N 7.AL ARM O N

: : : : : : :

L1 L1 L1 L1 L1 L1 L1

L2 L2 L2 L2 L2 L2 L2

L3 L3 L3 L3 L3 L3 L3

L4 L4 L4 L4 L4 L4 L4

L5 L5 L5 L5 L5 L5 L5

L6 L6 L6 L6 L6 L6 L6

L7 L7 L7 L7 L7 L7 L7

L8 L8 L8 L8 L8 L8 L8

L9 L9 L9 L9 L9 L9 L9

L1 0 L1 0 L1 0 L1 0 L1 0 L1 0 L1 0

L 11 L 11 L 11 L 11 L 11 L 11 L 11

L1 2 L1 2 L1 2 L1 2 L1 2 L1 2 L1 2

<< p res s E SC k ey to retu rn to main me nu, SPA CE key to ref res h >>

E X AM P LE 2: When Ground Start and Metering Pulse are available, the screen will show as below.
SLOT 1 FXO === FXO St atus == = 16:32 :48 05 /19/ 200 9

1.RI NGI NG 2.OF F-H OO K 3.TI P-O PE N 4.RI NG- GN D 5.BA TT- RE V 6.PU LSE O N 7.AL ARM O N

: : : : : : :

L1 L1 L1 L1 L1 L1 L1

L2 L2 L2 L2 L2 L2 L2

L3 L3 L3 L3 L3 L3 L3

L4 L4 L4 L4 L4 L4 L4

L5 L5 L5 L5 L5 L5 L5

L6 L6 L6 L6 L6 L6 L6

L7 L7 L7 L7 L7 L7 L7

L8 L8 L8 L8 L8 L8 L8

L9 L9 L9 L9 L9 L9 L9

L1 0 L1 0 L1 0 L1 0 L1 0 L1 0 L1 0

L 11 L 11 L 11 L 11 L 11 L 11 L 11

L1 2 L1 2 L1 2 L1 2 L1 2 L1 2 L1 2

<< p res s E SC k ey to retu rn to main me nu, SPA CE key to ref res h >>

NOTE1:

L1 means the status of Line1 and L 1 means the status of Line1 is active. As the above example shows: 1. RINGING: L 3 means the status of Line 3 is receiving RINGING; 2. TIP-OPEN: L 1 means the status of Line 1 is Tip-Open; 3. PULSE ON: L6 means the status of Line 6 is receiving PULSE signal.

25

CHAPTER 3 TERMINAL OPERATION 3.2.3 System Setup Under FXO Port Menu, press S to setup FXO system, then the following screen will show up.
When L1s decode level value is changed, L2s value will be automatically changed by the system. Also if L2s value is changed, L1s value will be changed too. Same operation is applied for L3 and L4, L5 and L6, L7 and L8, L9 and L10, L11 and L12 The option Metering Pulse Detect Mode is allowed to select a desired detect mode of pulse. T wo modes, NORM AL and PACKET , are available here. Use TAB key to switch a desired item. For NORM AL mode (Tone Follower mode), a logic level for the period of a correct decode. For P ACKET mode, respond/ de-respond after a cumulative period of tone or no-tone in a preset period.

E X AM P LE 1: When Metering Pulse is not available, the screen will show as below.
SLOT 1 FXO === Sy stem Co nfi gura tio n = == 16 :32: 48 05/ 19/2 009 ARRO W K EYS : CU RSO R M OVE, TA B: ROLL OP TIO NS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign al ing Bit A B C D Rx S ign a ling Bi t A B C D RING I NG : 0 0 0 1 OFF-H OOK : 1 1 * * NO R I NG : 0 1 0 1 OO S-AL ARM : * * * * BATT -R EV : 0 1 0 0 RING- GND : 0 0 0 1 PULS E ON : 0 1 0 0 ( * for d on't ca re ) TIP- OP EN : 1 1 1 1 Trun k C ond itio n : ON -HOO K Line Po lar ity : NO RMAL

<< P res s E SC k ey to retu rn to prev iou s m enu >>

E X AM P LE 2: When Metering Pulse is available, the screen will show as below. This screen is allowed to setup metering pulse frequency, pulse mode, and minimum pulse decode level for each line.
SLOT 1 FXO === Sy stem Co nfi gura tio n = == 16 :32: 48 05/ 19/2 009 ARRO W K EYS : CU RSO R M OVtE , T AB: ROL L O PTI ONS A/u- Law : A Imp e danc e : 60 0 oh m L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L 11 L12 TxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 RxGa in: -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 -3.0 -3. 0 -3.0 -3 .0 -3 .0 ALL Tx/ Rx Gain = L1 : NO ( - 2 1 ~ +10 in dB ) Tx S ign al ing Bit A B C D Rx S ign a ling Bi t A B C D RING I NG : 0 0 0 1 OFF-H OOK : 1 1 * * NO R I NG : 0 1 0 1 OO S-AL ARM : * * * * BATT -R EV : 0 1 0 0 RING- GND : 0 0 0 1 PULS E ON : 0 1 0 0 ( * for d on't ca re ) TIP- OP EN : 1 1 1 1 Trun k C ond itio n : ON -HOO K Line Po lar ity : NO RMAL Mete rin g P ulse Fr equ ency : Mete rin g P ulse De tec t Mo de : Mini mum Pu lse Dec ode Lev el ( L1 L2 L3 -27 -27 -27 ALL Lev el= L1 : N O 1 6 KH z N ORMA L - 19 ~ -4 7 ) L4 L5 L6 -2 7 -27 -2 7

L7 -27

L8 -2 7

L9 -27

L 10 - 27

L1 1 -2 7

L 12 - 27

(d Bm)

<< P res s E SC k ey to retu rn to prev iou s m enu >>

NOTE1: NOTE2:

ALL Level= L1 : NO, this option is allowed to copy Line 1s pulse decode value to all lines or not. Use TAB key to switch YES (copy to all) or NO (not copy to all).

* represents dont care. If OOS-Alarm is set as ****, it means the OOS alarm function is now disabled. If Ring-GND is set as ****, it means the ring-GND function is now disabled. If OFF-HOOK status is set as ****, it means the OFF-HOOK function is now disabled. If the software version is V2.01.03 or after and the OFF-HOOK status is set as ****, it means all twelve ports are set as OFF-HOOK.

26

CHAPTER 3 TERMINAL OPERATION

3.2.4

Diagnostics Test Under FXO Port Menu, press T to do diagnostics test, then the screen will show as below. Two options are available for diagnostics test: OFF-HOOK TEST and PULSE DECODE LEVEL SCAN. Use TAB key to select the desired option. The current selection will be highlighted by an asterisk (*). OFF-HOOK TEST:
SLOT 1 FXO === D iagn ost ic Test == = 16 :32: 48 05/ 19/2 009

*1.O FF- HO OK T EST

2.PU LSE DEC ODE LEV EL SCA N

- ST ATU S :

Rema in 1 1 se con ds.

<< p res s E SC k ey to retu rn to main me nu >>

PULSE DECODE LEVEL SCAN: After done the scan of pulse decode level, the system will show up detected value of each line in the screen. Press Y to copy the detected value to Pulse Decode Level of System Setup screen. Or press N or ESC key to cancel the copy. NA means no found any signal in line.
SLOT 1 FXO === FXO D iagn ost ic Test == = 16 :32: 48 05/ 19/2 009

1.OF F-H O OK T EST

*2.P U LSE DEC ODE LEV EL SCA N

- ST ATU S : Dete cte d V alue L1 NA

L2 NA

L3 NA

L4 NA

L5 NA

L6 NA

L7 NA

L8 NA

L9 NA

L1 0 NA

L11 NA

L 12 NA

(dBm )

Copy De tec ted Val ue to S yst em Setu p ( Pul se D eco de Leve l) (Y/ N)

<< p res s E SC k ey to retu rn to main me nu >>

27

CHAPTER 3 TERMINAL OPERATION

3.2.5 Upgrade Firmw are Press G from the Port Menu to start your flash download. Key in the server IP and firmware file name. Then, press Enter to start the download.
LOOP AM3 440 -A = == D own load Fir mwa re == = 1 6:3 3:3 1 05/ 19/ 20 0 9 ARRO W K EYS : CU RSO R M OVE, Pl eas e In put : n nn.n nn. nnn .nnn , B ACK SPAC E t o e dit

Bank 1 Fir mwar e V er. : V 2.0 1.0 1 04 /20 /20 09 Bank 2 Fir mwar e V er. : V 2.0 1.0 1 05 /07 /20 09 Work ing Fi rmwa re Ban k: 2 TFTP Se rve r IP Firm war e F ile Nam e : 0 10. 003 .013 .01 0 :

(Go od) (Go od)

<< p res s E SC k ey to retu rn to main me nu >>

3.2.6 Unit Load Default Configuration Press Y from Port Menu to return the default. Then press Y or N to confirm the selection.
SLOT 1 FXO === U nit Me nu = == 16:32:48 05/19/2009

Load de fau lt - ar e y ou s ure (Y /N)?

3.2.7 Unit Reset Press Z from Port Menu to reset the unit. Then press Y or N to confirm the selection.
SLOT 1 FX O == = Un it Men u == = 16:32:48 05/19/2009

Rese t - ar e yo u s ure ? [ Y/N ]

If users enter "Y" to confirm the reset, the system will request users to enter the password, LOOP, then press ENTER.
SLOT 1 FXO === U nit Me nu = == 16:32:48 05/19/2009

==>> En ter pas swo rd :

28