Wind Loading

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

Wind Pressure in accordance with NZS 4203:1992

V(z) = V.Mls.M(z,cat).Ms.Mt.Mr where V = basic directional wind speed Mls.= limit state multiplier

= =

45 0.93 0.75 0.808 0.92 1.06 5.5 1 1 1

m/s ultimate serviceablity fatigue ULS SLS m

M(z,cat).= site terrain / height multiplier Category 2 1 ULS SLS Ms. = shielding multiplier Mt. = topographic multiplier Mr = structure risk multiplier

= = Height = = = Ultimate

Serviceability 35.8 m/s 0.77 kPa

Fatigue 38.5 m/s 0.89 kPa

Velocity (>=30 m/s for ultimate) Design Wind Pressure Design Wind Pressure = 0.6xV2x10-3 Local Pressure Factors Hording - factor = 1.5

38.5 m/s 0.89 kPa

1.5

1.5

1.5

NET WIND PRESSURE

1.33 kPa

1.15 kPa

1.34 kPa