Shaft Vibration Data Acquisition Unit - AC8010 The Data Acquisition Unit (DAU) is part of the ALSPA Care Shaft Vibration Monitoring and Diagnostic System. It samples the signal inputs such as rotating speed, vibration, process signals, converts them from analog to digital and transfers the data to ALSPA Care Server. Type AC8010 is designed for Thermal Power. Doc3324 en Rev. B

FEATURES Shaft Vibration Data Acquisition Unit (DAU) Part number: AC8010 Reference ALSTOM Ordering Information: AXX -BXX-CXX-DXX A: Qty. of Tachophasor channels (Max. 8 channels) B: Qty. of Vibration Channels (Max. 48 channels) C: Qty. of Static Channels (Max. 24 channels) D: Sampling method(01: Sync / Async, 02: Sync & Async) 19, 3U high 134mm x 451mm x 484mm (H x W x D) 12.6 kg IP 50 100 VAC 240 VAC, 50 60Hz Max. 60 W

Mechanical Chassis Construction Dimensions Weight Protection Power Operating Voltage Requirements Wattage
ALSTOM 2012. All rights reserved.

The ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective companies. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

1/3 POWER| ABCD

ALSTOM Power PAC Power Automation & Controls - Helpdesk: pac.alspacare@alstom.com

Shaft Vibration
Data Acquisition Unit

Doc3324 en Rev. B Communication COM1 COM2 TCP/IP D-sub 9 for DAU setup D-sub 9, RS232, Baud rate: Max. 19.2kps Modbus communication with control system to obtain process data 1 x RJ45, 10/100 Base-TX Communication with ALSPA Care server for transmit data Max. once per second Min. 2 kbps/channel 1GB / 30 days average, automatic uploading on recovery Max. 8 channels 36 59999 rpm 400 k 25 V DC 1.5 rpm 0.2 V / 0.4 V / 0.6 V / 0.8 V / 1.0 V / 1.2 V / 1.4 V / 1.6 V 1 V / 2 V/ 3 V / 4 V / 5 V / 6 V / 7 V / 8 V Max. 48 channels in Type I mode(synchronous / asynchronous) Displacement / Velocity / Acceleration 400 K 20 V DC Max. 4 V / 400mV <10 mV <10 mV (range: 0 4 V), <2 mV (range: 0 400 mV) <-1 4 (60 rpm 120 krpm) Cutoff Frequency Selectable from 0 3 kHz Cutoff Frequency Selectable from 50 25 kHz Max. 24 channels Differential DC input 400 k 20 V DC <10 mV Cutoff Frequency: 2 Hz

Data Upload Upload Rate to Server Bandwidth Requirement Data Buffering Capacity Tachophasor Input Number of Channels Speed Range Input Resistance Input Range Measuring Error Trigger Voltage Threshold

Dynamic Input Number of Channels Supported Vibration Signals Input Resistance DC Input Range AC Input Range DC Measuring Error AC Measuring Error Phase Measuring Error High-Pass Filter Low-Pass Filter Static Input Number of Channels Input Type Input Resistance DC Input Range DC Measuring Error Low-pass Filter

ALSTOM 2012. All rights reserved.

The ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective companies. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

2/3 POWER| ABCD

ALSTOM Power PAC Power Automation & Controls - Helpdesk: pac.alspacare@alstom.com

Shaft Vibration
Data Acquisition Unit

Doc3324 en Rev. B Data Processing Sampling Speed A / D Resolution Spectrum Lines FFT Windowing Max. 2048 samples per revolution 14 bit Max. 6400 Rectangular Hanning Hamming Triangular Bartlett Blackman Flat top window Exponential window LEDs (power, self-check, Ethernet link status, com1 link status, com2 link status ) Operating: 0 C ... 5 C Storage: -40 C ... 80 C 0% 95%(no condensation) Electrical equipment for measurement, control and laboratory useEMC requirements Part 1: General requirements. Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements Radio frequency devices-unintentional radiators 10 gn for 11ms 3.5 mm/peak (5 ... 9 Hz) 1 gn (9 ... 150 Hz)

Service Diagnostics

Environment Temperature Relative Humidity Standards and EN 61326-1: 2006 Certifications EN 61010-1: 2010 FCC Part 15 Subpart B: 2011 Shock Vibration

ALSTOM 2012. All rights reserved.

The ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective companies. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

3/3 POWER| ABCD

ALSTOM Power PAC Power Automation & Controls - Helpdesk: pac.alspacare@alstom.com

You might also like