H.W.D.P. INSPECTION REPORT


JC INTERNATIONAL BASE
Date: 10/05/2013

Slip, Upset & C.P. OD Area

OD

ID

Connection Length

Width

Pin Neck Length.

Pin Nose Dia.

Seal Width

OD

Dia.

Countrebore Dia.

Dia.

Width

Seal Width

Box Length

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

3.

JC 003

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

6.31/32''

5.29/32''

6.3/4''

5/32'' 13/32''

5.632

4.

JC 004

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

5.

JC 005

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

6.

JC 006

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

7.

JC 007

6.31/32''

4''

5.625

6.23/32

5/32''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

8.

JC 008

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.3/4''

9.

JC 009

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.3/4''

10.

JC 010

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.3/4''

11.

JC 011

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.23/32''

12.

JC 012

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

7''

5.29/32''

6.3/4''

Condition

Condition

Hard Banding

Condition

JC 002

Center Pad OD

JC 001

2.

Condition

1.

Box Connection

Tool S. No.

Pin Connection

Tube Condition

Box Tool Joint

Bevel

Inspected Joint ( s ): 12 Joints


R Acceptable: 10 Joints
T Repairable: 2 Joints
Note:- Tool No. JC 007 has Stretched Thread ( S/T) and JC 009 has Galled thread (GT), therefore should be repaired.
Abbrevations:Seal Damage

SD Crack

Thread Damage
Belled Box

Bevel

Tong Space

6.13/32'' 15.29/32'' 16.23/32''

Total Length (Ft )

Page No.: 1

Pin Tool Joint

MPI

Visual Inspection

LOCATION:

Report No.: 13405

Box

SIZE: 5.1/2''

RIG: WEST CAPELLA

Pin

SEADRILL
Connection: 5.1/2'' FH VAM EIS

Min. Centre Pad OD Dia.

CLIENT:

30.49

15.9/32''

16.3/4''

30.23

6.3/8''

17.1/8''

15.7/8''

30.04

6.3/8''

17.13/32''

16.7/8''

30.46

5.632

6.3/8''

15.5/16''

16.15/16''

30.18

5.632

6.3/8''

17.1/2''

16.5/8''

30.55

5.632

6.3/8''

16.31/32''

17.3/32''

30.43

5./32'' 13/32''

5.632

6.13/32''

17.1/8''

16.1/16''

30.51

5/32'' 13/32''

5.632

6.3/8''

17.1/4''

15.15/16''

30.49

5/32'' 13/32''

5.632

6.3/8''

12.1/4''

16.3/4''

30.01

3/16''

5.632

6.3/8''

17.3/8''

17''

30.3

5.632

6.3/8''

17.1/8''

16.1/8''

30.36

3/8''

5/32'' 13/32''

Remarks

FOR REPAIR

FOR REPAIR

Junk

CRK

Wash Out

WO Acceptable

ACC

Not Acceptable

NA

TD Refaced

RF

Pitted Seal

PT

Rejectable

REJ

Hard Banding

HB

BB Galled Thread

GT

Corroded Thread

CT

Stretched Thread

ST

Pitted Thread

PT

Inspector: SUNNY E. AMADI


ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )
Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

JC International Limited RC 413243


Port Harcourt Office:
Plot 5 JC Street, Off Peter Odili Road,
P.O. Box 6427, Trans Amadi, Port Harcourt
Rivers State, PH: +234-84-489909
Email:service@jcinternationalng.com

Lagos Office:
56A, Bourdillon Road,
P.O. Box 52224
Ikoyi, PH: +234-1-842-5813

H.W.D.P. INSPECTION REPORT


SIZE: 5.1/2''

LOCATION:

Report No.: 13406

Page No.: 2

Pin Tool Joint

MPI

JC INTERNATIONAL BASE
Date: 10/05/2013

OD

ID

Connection Length

Width

Pin Neck Length.

Pin Nose Dia.

Seal Width

OD

Dia.

Countrebore Dia.

Dia.

Width

Seal Width

Box Length

6.31/32''

4''

5.625

6.23/32

3/16''

5/16''

4.680

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

JC 014

7''

4''

5.625

6.23/32

7/32''

5/16''

4.682

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

JC 015

7''

4''

5.625

6.23/32

7/32''

5/16''

4.673

3/8''

7''

5.29/32''

6.3/4''

5/32'' 13/32''

5.632

16

JC 016

7''

4''

5.625

6.23/32

7/32''

5/16''

4.682

3/8''

7''

5.29/32''

6.3/4''

5./32'' 13/32''

17

JC 017

7''

4''

5.625

6.23/32

7/32''

5/16''

4.688

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

18

JC 018

7''

4''

5.625

6.23/32

7/32''

5/16''

4.683

3/8''

6.31/32

5.29/32''

6.23/32''

3/16''

3/8''

19

JC 019

7''

4''

5.625

6.23/32

7/32''

5/16''

4.676

3/8''

7''

5.29/32''

6.3/4''

20

JC 020

7''

4''

5.625

6.23/32

7/32''

5/16''

4.679

3/8''

7''

5.29/32''

21

JC 021

7''

4''

5.625

6.23/32

7/32''

5/16''

4.680

3/8''

7''

22

JC 022

7''

4''

5.625

6.23/32

7/32''

5/16''

4.676

3/8''

6.31/32''

23

JC 023

7''

4''

5.625

6.23/32

7/32''

5/16''

4.680

3/8''

24

JC 024

7''

4''

5.625

6.23/32

7/32''

5/16''

4.678

3/8''

Inspected Joint ( s ): 12 Joints


R Acceptable: 11 Joints
Note:- Tool No. JC 015 has Stretched Thread ( S/T), therefore should be repaired.
Abbrevations:-

Bevel

Tong Space

Box

Bevel

Pin

15

Condition

14

Condition

Hard Banding

Condition

JC 013

Center Pad OD

13

Condition

Tool S. No.

Box Connection

Pin Connection

Slip, Upset & C.P. OD Area

Box Tool Joint

Tube Condition

Visual Inspection

RIG: WEST CAPELLA

Total Length (Ft )

SEADRILL
Connection: 5.1/2 FH VAM EIS

Min. Centre Pad OD Dia.

CLIENT:

17.1/8''

15.7/8''

30.34

6.3/8''

16''

16.7/8''

30.39

6.3/8''

17.7/16''

17.1/8''

30.57

5.632

6.3/8''

17.3/16''

16.27/32''

30.32

5.632

6.3/8''

15.7/8''

16.11/16''

30.20

5.632

6.5/16''

17.3/8''

16.3/4''

30.33

5/32'' 13/32''

5.632

6.3/8''

16.7/16''

16.7/8''

30.45

6.23/32''

3/16''

3/8''

5.632

6.3/8''

17.3/32''

16.3/4''

30.6

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

17.1/4''

16.7/8''

30.58

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

15.29/32''

17''

30.39

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

15.5/8''

16.15/16''

30.42

6.31/32''

5.29/32''

6.23/32''

3/16''

5.632

6.3/8''

15.1/2''

12.7/16''

29.95

Repairable: 1 Joints

3/8''

Remarks

FOR REPAIR

Junk

Seal Damage

SD Crack

CRK

Wash Out

WO Acceptable

ACC

Not Acceptable

NA

Thread Damage

TD Refaced

RF

Pitted Seal

PT

Rejectable

REJ

Hard Banding

HB

Belled Box

BB Galled Thread

GT

Corroded Thread

CT

Stretched Thread

ST

Pitted Thread

PT

Inspector: SUNNY E. AMADI


ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )
Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

JC International Limited RC 413243


Port Harcourt Office:
Plot 5 JC Street, Off Peter Odili Road,
P.O. Box 6427, Trans Amadi, Port Harcourt
Rivers State, PH: +234-84-489909
Email:service@jcinternationalng.com

Lagos Office:
56A, Bourdillon Road,
P.O. Box 52224
Ikoyi, PH: +234-1-842-5813

H.W.D.P. INSPECTION REPORT


SIZE: 5.1/2''

JC INTERNATIONAL BASE
Date: 10/05/2013

Page No.: 3

Pin Tool Joint

MPI

Box Tool Joint

OD

ID

Connection Length

Width

Pin Nose Dia.

Seal Width

OD

Dia.

Countrebore Dia.

Seal Width

Box Length

Pin

Box

7''

4''

5.625

6.23/32

3/16

5/16

4.679

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

6.3/8

15.15/16

17.1/32

30.41

26

JC 026

7''

4''

5.625

6.23/32

3/16

5/16

4.688

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

6.3/8

17.11/16

16.13/16

30.55

27

JC 027

7''

4''

5.625

6.23/32

3/16

5/16

4.687

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

6.3/8

17.3/16

15.7/8

30.44

28

JC 028

7''

4''

5.625

6.23/32

3/16

5/16

4.689

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.3/8

17.1/2

16.13/16

30.54

29

JC 029

7''

4''

5.625

6.23/32

3/16

5/16

4.684

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.3/8

17''

16.3/4

30.53

30

JC 030

7''

4''

5.625

6.23/32

3/16

5/16

4.685

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.3/8

17.3/32

16.7/8

30.51

31

JC 031

7''

4''

5.625

6.23/32

3/16

5/16

4.780

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.3/8

17.5/16

16.7/8

30.47

32

JC 032

7''

4''

5.625

6.23/32

3/16

5/16

4.673

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.13/32

17''

16.3/4

30.70

33

JC 033

7''

4''

5.625

6.23/32

3/16

5/16

4.680

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.13/32

15''

17.1/32

30.31

34

JC 034

7''

4''

5.625

6.23/32

3/16

5/16

4.679

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.13/32

17.1/4

16.1/16

30.45

35

JC 035

7''

4''

5.625

6.23/32

3/16

5/16

4.673

3/8 6.31/32

5.29/32

6.23/32

5/32

3/8

5.632

6.13/32

16.1/8

15.7/8

30.49

36

JC 036

7''

4''

5.625

6.23/32

3/16

5/16

4.676

3/8

5.29/32

6.23/32

3/16

3/8

5.632

6.13/32

17.1/32

16.7/8

30.53

R Acceptable: 12 JOINTS

Inspected Joint ( s ): 12 Joints


Note:Abbrevations:-

7''

Repairable

Width

Bevel

Dia.

Bevel
Pin Neck Length

Condition

Condition

Hard Banding

Condition

Center Pad OD

JC 025

Condition

25

Box Connection

Tool S. No.

Pin Connection

Slip, Upset & C.P. OD Area

Tong Space

Tube Condition

Visual Inspection

LOCATION:

RIG: WEST CAPELLA


Report No.: 13407

Total Length (Ft )

SEADRILL
Connection: 5.1/2 FH VAM EIS

Min. Centre Pad OD Dia.

CLIENT:

Remarks

Junk

Seal Damage

SD Crack

CRK

Wash Out

WO Acceptable

ACC

Not Acceptable

NA

Thread Damage

TD Refaced

RF

Pitted Seal

PT Rejectable

REJ

Hard Banding

HB

Belled Box

BB Galled Thread

GT

Corroded Thread

CT Stretched Thread

ST

Pitted Thread

PT

Inspector: SUNNY E. AMADI


ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )
Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

JC International Limited RC 413243


Port Harcourt Office:
Plot 5 JC Street, Off Peter Odili Road,
P.O. Box 6427, Trans Amadi, Port Harcourt
Rivers State, PH: +234-84-489909
Email:service@jcinternationalng.com

Lagos Office:
56A, Bourdillon Road,
P.O. Box 52224
Ikoyi, PH: +234-1-842-5813

H.W.D.P. INSPECTION REPORT


LOCATION:

Report No.: 13408

Page No.: 4

Pin Tool Joint

MPI

JC INTERNATIONAL BASE
Date: 10/05/2013

Width

Pin Neck Length.

Pin Nose Dia.

Seal Width

OD

Dia.

Countrebore Dia.

Dia.

Width

Seal Width

Box Length

7''

4''

5.625

6.23/32

3/16''

5/16''

4.676

3/8''

6.31/32''

5.29/32''

6.23/32''

5./32''

3/8''

5.632

6.13/32''

38

JC 038

7''

4''

5.625

6.23/32

3/16''

5/16''

4.672

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32'' 17.19/32''

39

JC 039

7''

4''

5.625

6.23/32

3/16''

5/16''

4.678

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32'' 17.13/32'' 15.13/16''

30.42

40

JC 040

7''

4''

5.625

6.23/32

3/16''

5/16''

4.674

3/8''

6.31/32''

5.29/32''

6.23/32''

5./32''

3/8''

5.632

6.13/32''

17.1/4''

16''

30.36

41

JC 041

7''

4''

5.625

6.23/32

3/16''

5/16''

4.683

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

17.5/16''

15.7/8''

30.08

42

JC 042

7''

4''

5.625

6.23/32

3/16''

5/16''

4.679

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32''

17.1/4''

16''

30.55

43

JC 043

7''

4''

5.625

6.23/32

3/16''

5/16''

4.685

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32''

17.3/8''

16.7/8''

30.57

44

JC 044

7''

4''

5.625

6.23/32

3/16''

5/16''

4.683

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32'' 15.13/16''

16.7/8''

30.37

45

JC 045

6.31/32''

4''

5.625

6.23/32

5/32''

5/16''

4.684

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32''

17.7/32''

16.29/32''

30.43

46

JC 046

7''

4''

5.625

6.23/32

3/16''

5/16''

4.684

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32''

16.1/32''

17.3/32''

30.54

47

JC 047

7''

4''

5.625

6.23/32

3/16''

5/16''

4.678

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.13/32''

17.1/8''

16.7/8''

30.51

48

JC 048

7''

4''

5.625

6.23/32

3/16''

5/16''

4.673

3/8''

7''

5.29/32''

6.23/32''

3/16''

3/8''

5.632

6.3/8''

17.3/8''

16.7/8''

30.45

Condition

Bevel

Box

Connection Length

Bevel

Pin

ID

Condition

Hard Banding

Condition

Center Pad OD

JC 037

Condition

37

Box Connection

Tool S. No.

Pin Connection

OD

Tong Space

Slip, Upset & C.P. OD Area

Box Tool Joint

Tube Condition

Visual Inspection

RIG: WEST CAPELLA

Total Length (Ft )

SIZE: 5.1/2''

SEADRILL
Connection: 5.1/2 FH VAM EIS

Min. Centre Pad OD Dia.

CLIENT:

17.1/8''

16.7/8''

30.50

16.3/4''

30.54

Remarks

FOR REPAIR

FOR REPAIR

FOR REPAIR

Inspected Joint ( s ): 12 Joints


Junk
R Acceptable: 9 Joints
T Repairable: 3 Joints

Note:- Tool No. JC 041 has Seal Damage ( S/D), JC 046 has Galled Thread (G/T) and JC 048 has Stretched Thread (S/T), therefore should be repaired.
Abbrevations:Seal Damage

SD Crack

CRK

Wash Out

WO Acceptable

ACC

Not Acceptable

NA

Thread Damage

TD Refaced

RF

Pitted Seal

PT

Rejectable

REJ

Hard Banding

HB

Belled Box

BB Galled Thread

GT

Corroded Thread

CT

Stretched Thread

ST

Pitted Thread

PT

Inspector: SUNNY E. AMADI


ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )
Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

JC International Limited RC 413243


Port Harcourt Office:
Plot 5 JC Street, Off Peter Odili Road,
P.O. Box 6427, Trans Amadi, Port Harcourt
Rivers State, PH: +234-84-489909
Email:service@jcinternationalng.com

Lagos Office:
56A, Bourdillon Road,
P.O. Box 52224
Ikoyi, PH: +234-1-842-5813

H.W.D.P. INSPECTION REPORT


JC INTERNATIONAL BASE
Date: 10/05/2013

Slip, Upset & C.P. OD Area

OD

ID

Connection Length

Width

Pin Nose Dia.

Seal Width

OD

Dia.

Countrebore Dia.

Seal Width

Box Length

7''

4''

5.625

6.23/32

3/16

5/16

4.681

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

50

JC 050

7''

4''

5.625

6.23/32

3/16

5/16

4.679

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

51

JC 051

7''

4''

5.625

6.23/32

3/16

5/16

4.680

3/8

7''

5.29/32

6.23/32

3/16

3/8

5.632

R Acceptable: 3 JOINTS

Inspected Joint ( s ): 3 Joints


Note:Abbrevations:-

Repairable

Width

Bevel

Dia.

Pin Neck Length

Condition

Condition

Hard Banding

Condition

Center Pad OD

JC 049

Condition

49

Box Connection

Tool S. No.

Pin Connection

Tube Condition

Box Tool Joint

Bevel

Tong Space

Total Length (Ft )

Pin Tool Joint

MPI

Visual Inspection

LOCATION:
Page No.: 5

Box

SIZE: 5.1/2''

RIG: WEST CAPELLA


Report No.: 13409

Pin

SEADRILL
Connection: 5.1/2 FH VAM EIS

Min. Centre Pad OD Dia.

CLIENT:

17.3/8

16.7/8

30.51

6.3/8

17.1/4

15.1/4

30.24

6.13/32

16.13/16

16.7/8

30.70

6.13/32

Remarks

Junk

Seal Damage

SD Crack

CRK

Wash Out

WO Acceptable

ACC

Not Acceptable

NA

Thread Damage

TD Refaced

RF

Pitted Seal

PT Rejectable

REJ

Hard Banding

HB

Belled Box

BB Galled Thread

GT

Corroded Thread

CT Stretched Thread

ST

Pitted Thread

PT

Inspector: SUNNY E. AMADI


ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )
Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

JC International Limited
Port Harcourt Office:
Plot 5 JC Street, Off Peter Odili Road,
P.O. Box 6427, Trans Amadi, Port Harcourt
Rivers State, PH: +234-84-489909
Email:service@jcinternationalng.com

RC 413243

Lagos Office:
56A, Bourdillon Road,
P.O. Box 52224
Ikoyi, PH: +234-1-842-5813
Website:www.jcinternationalng.com

SUMMARY REPORT
REPORT #: 13410
SEADRILL
SD/MT/TI/05/2013

R
R

API RP 5CT

Visual Tube
MPI of Slip & Upset Area
MPI of Elevator Groove
Black Light Connection
FLUT 1

R
R

R
R

Visual Connection
MPI of C. Pad OD Area
UT of Slip & Upset Area
EXT. COATING
Full EXT. & INT. CLEANING

Size: 5.1/2''
Grade:

Connection:
Nom. Thk.:

Description

45
5
1

5.1/2" H.W.D.P.
5.1/2" H.W.D.P.
5.1/2" H.W.D.P.

Pin
OK Rej.
R
R

Box
OK Rej.
R

R

API RP 7G

Body
OK Rej.
R
R
R

le
eab
vic
r
e
S

TUBING & CASING

H.W.D.P.

Qty.

D.P.

e
abl
air

p
Re

R
R

OTHER

CUSTOMER SPEC.
R
R

5.1/2'' FH VAM EIS Qty.:


Weight:
ss
2

Type:
Range:

DS-1, Cat. 3-5

Inspection Method:

B.H.A.

Cla

Standard:

Rig: WEST CAPELLA

Cla
ss

Type of Service:

10/5/2013
Date:
Location: JC INTERNATIONAL BASE

P.

Customer:
W.O. No.:

51

READY FOR USE


TO BE REPAIRED BEFORE USE
TO BE REPAIRED BEFORE USE

51 Total Joint Inspected


{ Total Page ( s ) included 6 }

Customer Sign.

SUNNY E. AMADI
ASNT NDT LEVEL II ( VT,MT,PT,UT,RT )

Full Member

Cert No: 227173

Lifting Equipment
Engineers Association

CORPORATE PARTNER

Result

Junk

MPI
Dimensional
UT Wall Thk.
EMI
API Drift