Installation Recommendations
Place the telephone on a non-slip surface. Polished or varnished surfaces can be marked by some parts of the telephone, such as the rubber feet. To ensure good hands-free conversation quality, place the telephone on a flat surface and keep the area in front of the microphone free of obstructions. To avoid interference, keep the telephone at least one meter away from cordless telephones, mobile telephones, television sets and other electrical equipment. The Profiset 3030 telephone must be installed at a maximum distance of 500 meters from the telephone exchange by using a two-pair cable with 0.4mm2 copper wire. The telephone must not be exposed directly to the sun or other heat sources, nor be installed in dusty or excessively humid locations, as this will reduce its useful life. It should be used at temperatures between 5 C and 50 C and it is not waterproof. To clean the telephone, use a damp cloth and avoid abrasive cleaning products. Do not use a dry cloth, because it may cause electrostatic discharges that could damage the equipment. When the telephone reaches the end of its useful life, dispose of it in a way that does not harm the environment, in accordance with local legal requirements.
CE Mark
The device conforms to the EU guideline 99/5/ ECC, as attested by the CE mark.
Installation Recommendations
Installation
Labeling Strip
Your Profiset 3030 telephone has a labeling strip for writing down names, telephone numbers and functions stored in the programmable keys. If you need to change the labels, cut out the template supplied on the last page of this manual.
Characteristics
It has a 3-line display The first line displays the MUTE symbol, the repeat call counter, the repeat call indicator, and the time and date. The time is shown in 24-hour or AM/PM (hours:minutes) format and the date in day/month format (for example, 11:13 28/08). When you are in operator terminal mode, the number of unanswered internal, external and recalled calls is shown on the second line (16 digits). The messages are shown, 16 characters, on the third line.
1.
2. Repeat call counter 3. Time 4. AM/PM indicator 5. Date 6. Repeat call indicator 7 . Field for operator terminal 8. Field for alphanumeric characters
1. 2. 3. 4. 5. 6.
Handset cradle Function keys Programmable keys with status indicator LEDs Hands-free loudspeaker Hands-free microphone Display 6
1.The REDIAL function key is only used for telephone MENU navigation
Navigation Key Shows PREVIOUS option Navigation Key. Shows NEXT option. Confirmation Key Selects (confirms) the displayed option. SPEAKER key, activates hands-free mode using microphone and loudspeaker. REDIAL key redials the last number called. MENU key for access to menu-driven configuration settings. FLASH key invokes the flash function for the external line. FEATURE key activates the system functions (for example, Forward, Do not disturb, etc). MUTE key deactivates voice transmission so the person with whom you are speaking cannot hear you any more. To reactivate voice transmission, press the key again.
Configuration
Configuration
For greater user convenience, the Profiset 3030 system telephone provides some configuration options. The following keys are used in configuration mode: Profiset 3030 - S30058-H6202-A1/A2
and
or
and
and
or
and
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
10
Configuration
melody
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
11
Configuration
volume RX
volume RX
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
12
Configuration
Dialing Mode
If your system is not working because of a power outage and the external telephone line has been switched directly to your Profiset 3030 system telephone, you will need to specify the dialing mode (pulse or tone) for this line, because in normal operation the telephone exchange performs this setting automatically.
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
13
Configuration
Display Brightness
The display brightness can be adjusted to 3 levels; it is preset to level 2.
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
14
Configuration
Time Format
The time can be shown on the display in 24-hour or AM/PM format.
or
and
Continue navigating through the menu options or press the Menu key to finish the configuration.
15
Configuration
Other Settings
You can make additional settings with the following sequence:
+ Code
00 01
+ Code
Description
Sets DTMF 85/85ms and enables DTMF mode Sets DTMF 140/85ms and enables DTMF mode
16
Configuration
Code
02 03 04 05 06 07 08 09 10 11 12 13 14 15 20
Description
Sets pulse dialing open/closed ratio to 2:1 (33/66ms) and enables pulse dialing Sets pulse dialing open/closed ratio to 1.5:1 (40/60ms) and enables pulse dialing Automatic gain control disabled Automatic gain control enabled Ring frequency discrimination in the 15-75Hz range (in case of power outage) Ring frequency not discriminated Line impedance 600 (in case of power outage) Line impedance 1000 (in case of power outage) DTMF 85/85ms DTMF 140/85ms Pulse dialing proportion open/closed 2:1 (33/66ms) Pulse dialing proportion open/closed 1.5:1 (40/60ms) Time format DD/MM Time format MM/DD This code cancels the language setting configured by the user (manual configuration) and activates the system's default setting (automatic configuration). Portuguese (Brazil) Portuguese (Portugal) English (default) French Spanish Normal level of transmission High level of transmission Very high level of transmission Return to factory programming For more detailed feature explanations, refer to your telephone exchanges user guide.
21 22 23 24 25 31 32 33 99
17
1 2 3 4 5 6 1 2 3
MELODY
MODE
TONE PULSE
FORMAT
24 HS AM PM
BRIGHT
1 2 3 1 2 3 4 5 6
VOLUME RX
18
A31003-K1250-B816-13-7619
1P A31003-K1250-B816-13-7619 The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Ref. No.:A31003-K1250-B816-13-7619 Printed in Brazil 26.09.06 Siemens Ltda 2006 Rua Pedro Gusso, 2635 Curitiba-PR/BR