Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

RE 29 933/10.

99

RE 29 933/10.99
Replaces: 02.98

Pressure Transducers Types HM 12 and HM 13


Series 1X

H/A 3702/93

Type HM 12

Contents
Contents Features Ordering code Technical data Terminal connection Unit dimensions Page 1 1 2 3 3

Features
Suitable for measuring pressures and for converting the measured values into electrical signal values Good temperature characteristics and high accuracy Standardised output signals for universally applications in hydraulic circuits EMC characteristics permit using in critical installations "low cost" type Sensor in thin film technology Accuracy class 0,5 % Measuring range up to 250, 315 or 400 bar Connection thread to DIN 3852 Parts in contact with the fluid are made of stainless steel Polarity safeguard, protection against short-circuits Compact design

Ordering code

HM
Pressure transducer with: Current output 4 to 20 mA Voltage output 0 to 10 V Series 10 to 19 (10 to 19: unchanged technical data and terminal connection) = 12 = 13

1X /

* Further details in clear text 250 = 315 = 400 = Measuring range: up to 250 bar up to 315 bar up to 400 bar

= 1X

HM 12; HM 13

1/4

RE 29 933/10.99

Technical data (For application outside these parameters please consult us!)
Input values Operating voltage Measuring range or or Overload protection Burst pressure Dead volume Output values Output signal: HM 12 HM 13 Temperature compensation: original range Linear tolerance Hysteresis Repeat accuracy Rise time Long term drift (6 months) : original range Conditions Nominal temperature range Operating temperature range Storage temperature range Fluid temperature range EMC-immunity to IEC 801-4 Shock Vibration duration to IEC 68-2-6 (at 10 to 500 Hz) Insulation to DIN 40 050 Mechanical technical data Pressure connection Electrical connection Weight
1)

UB pnom pnom pnom p V

12 to 30 V (ripple content < 5 %) up to 250 bar up to 315 bar up to 400 bar 150 % 1) 300 % 1); max. 1500 bar approx. 450 mm3

I U

4 to 20 mA (2-conductor) 0 to 10 V (3-conductor) typical 0,15 %/ 10 K; max. 0,3 %/ 10 K typical 0,15 %/ 10 K; max. 0,3 %/ 10 K typical 0,15 % 1); max. 0,3 % 1) typical 0,05 % 1); max. 0,1 % 1) 0,05 % 1)

0,5 ms 0,1 % 1) 0,1 % 1)

25 to + 85 C 40 to + 85 C 40 to + 100 C 40 to + 100 C class 3 500 g / 1 ms 20 g IP 65

G 1/4 A external thread to DIN 3852; soft-seal ring 4-pin plug to DIN 43 650 m 0,16 kg

taken at the full measurement range

Rexroth Hydraulics

2/4

HM 12; HM 13

RE 29 933/10.99

Terminal connection
HM12
RL 2 PE 1 3 Signal 4 20 mA 0V

The maximal permissible load resistance RL is dependent on the operating voltage + UB: RL max = + UB 10 V 20 mA (in )

+ UB (12 30 V)

RL can be at port 1 or 2.

HM13
0V 2 PE 1 3
Signal 0 10 V

+ UB (12 30 V)

We recommend a 2-core or 3-core connection cable type LiYCY (0,5 mm2).

Unit dimensions

(in mm)

11

12

33,6

36

84,5 27 A/F

Threaded connection to DIN 3852 Part 2

HM 12; HM 13

3/4

Rexroth Hydraulics

G1/4 A

27

RE 29 933/10.99

Notes

Mannesmann Rexroth AG Rexroth Hydraulics D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 eMail product.support@rexroth.de Internet www.rexroth.com

Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80 / 22 32 56 Fax: 0 14 80 / 21 90 52 E-mail: info@rexroth.co.uk

The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.

All rights reserved Subject to revision

4/4

HM 12; HM 13