RE 29 933/10.99
Replaces: 02.98
H/A 3702/93
Type HM 12
Contents
Contents Features Ordering code Technical data Terminal connection Unit dimensions Page 1 1 2 3 3
Features
Suitable for measuring pressures and for converting the measured values into electrical signal values Good temperature characteristics and high accuracy Standardised output signals for universally applications in hydraulic circuits EMC characteristics permit using in critical installations "low cost" type Sensor in thin film technology Accuracy class 0,5 % Measuring range up to 250, 315 or 400 bar Connection thread to DIN 3852 Parts in contact with the fluid are made of stainless steel Polarity safeguard, protection against short-circuits Compact design
Ordering code
HM
Pressure transducer with: Current output 4 to 20 mA Voltage output 0 to 10 V Series 10 to 19 (10 to 19: unchanged technical data and terminal connection) = 12 = 13
1X /
* Further details in clear text 250 = 315 = 400 = Measuring range: up to 250 bar up to 315 bar up to 400 bar
= 1X
HM 12; HM 13
1/4
RE 29 933/10.99
Technical data (For application outside these parameters please consult us!)
Input values Operating voltage Measuring range or or Overload protection Burst pressure Dead volume Output values Output signal: HM 12 HM 13 Temperature compensation: original range Linear tolerance Hysteresis Repeat accuracy Rise time Long term drift (6 months) : original range Conditions Nominal temperature range Operating temperature range Storage temperature range Fluid temperature range EMC-immunity to IEC 801-4 Shock Vibration duration to IEC 68-2-6 (at 10 to 500 Hz) Insulation to DIN 40 050 Mechanical technical data Pressure connection Electrical connection Weight
1)
12 to 30 V (ripple content < 5 %) up to 250 bar up to 315 bar up to 400 bar 150 % 1) 300 % 1); max. 1500 bar approx. 450 mm3
I U
4 to 20 mA (2-conductor) 0 to 10 V (3-conductor) typical 0,15 %/ 10 K; max. 0,3 %/ 10 K typical 0,15 %/ 10 K; max. 0,3 %/ 10 K typical 0,15 % 1); max. 0,3 % 1) typical 0,05 % 1); max. 0,1 % 1) 0,05 % 1)
G 1/4 A external thread to DIN 3852; soft-seal ring 4-pin plug to DIN 43 650 m 0,16 kg
Rexroth Hydraulics
2/4
HM 12; HM 13
RE 29 933/10.99
Terminal connection
HM12
RL 2 PE 1 3 Signal 4 20 mA 0V
The maximal permissible load resistance RL is dependent on the operating voltage + UB: RL max = + UB 10 V 20 mA (in )
+ UB (12 30 V)
RL can be at port 1 or 2.
HM13
0V 2 PE 1 3
Signal 0 10 V
+ UB (12 30 V)
Unit dimensions
(in mm)
11
12
33,6
36
84,5 27 A/F
HM 12; HM 13
3/4
Rexroth Hydraulics
G1/4 A
27
RE 29 933/10.99
Notes
Mannesmann Rexroth AG Rexroth Hydraulics D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 eMail product.support@rexroth.de Internet www.rexroth.com
Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80 / 22 32 56 Fax: 0 14 80 / 21 90 52 E-mail: info@rexroth.co.uk
The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.
4/4