API Tanks Form
API Tanks Form
Please fill out the form with the data you have available for your project and send it to info@mechanical-projects.com along with your contact email address and phone number.
TANK DETAILS Maximum capacity, m3 (bbl): Net working capacity, m3 (bbl): Overfill protection (API-2350), m3 (bbl) or mm (in.):
PRODUCT Product stored: Design specific gravity : Design metal temperature, C (F): Vapor pressure, kPa (in. Water): at C (F)
1/6
CORROSION ALLOWANCE Shell, mm (in.): Roof,mm (in.): Bottom, mm (in.): Structurals, mm (in.):
SHELL DESIGN Basic standard 650 (yes/no): Appendix A (yes/no): Appendix F (yes/no): Design pressure, kPa (lbf/in.2):
ROOF DESIGN Basic standard 650 (yes/no): Appendix G (Aluminium dome) (yes/no): Appendix C (External floating) (yes/no): Appendix H (Internal floating) (yes/no): Frangible roof joint? (yes/no):
ROOF DESIGN INFORMATION Uniform live load, kPa (lbf/ft2): Special loads (provide sketch), kPa (lbf/ft2): Insulation load, kPa (lbf/ft2): Maximum design roof temperature, C (F): Gases in the vapor space:
EARTHQUAKE DESIGN (Appendix E) Seismic zone: Zone factor (Table E-2): Roof tie rods (3.10.4.5) (yes/no): Importance Factor: Site coefficient (Table E-3):
WIND LOAD Velocity, km/h (mph): Provide intermediate wind girder (3.9.7) (yes/no):
ENVIRONMENTAL EFFECTS Maximum rainfall, mm/h (in./h): Total snow accumulation, mm/h (in./h):
2/6
N. of shell courses:
1. 2. 3.
4. 5. 6.
7. 8. 9.
TANK BOTTOM Plate thickness, mm (in.): Slope, mm/m (in/ft): Lap To Butt Seams From center
Roof-to-shell detail (Figure F-1): Intermediate wind girder? (yes/no) : Top wind girder for use as walkway? (yes/no):
ROOF TYPE Supported, self-supported or floating?: Slope or radius, mm (in.): Roof plate Thickness, mm (in.): Lap Butt Joint
3/6
PAINT Shell: Exterior? (yes/no): Surface preparation: Bottom Underside? (yes/no): Surface preparation: Structural Steel Exterior? (yes/no): Surface preparation: Interior? (yes/no): Interior? (yes/no): Interior? (yes/no):
Shop:
TANK SIZE Diameter Height Internal, m (ft): Internal, m (ft): External, m (ft): External, m (ft):
4/6
BOLTED DOOR SHEET Required? (yes/no - Appendix A Tanks only): Raised Flush
Scaffold Hitch:
INTERNAL PIPING Swing line: Suction line: Heating coil surface area, m2 (ft2):
(See figures 3-4B, 3-5, and 3-7 and tables 3-8, 3-9 and 3-10)
Threaded B C D E
Orientation N=0
5/6
ROOF NOZZLES, INCLUDING VENTING CONNECTIONS Mark / Size / Service Flanged Threaded
(See figures 3-14 and 3-15 and tables 3-16 and 3-17)
Reinforcement
Orientation N=0
Note: Sketches and/or separate sheets may be attached to cover special requirements
Thank you for taking the time to fill out this form. Please email this form with the rest of information that you have to info@mechanical-projects.com. We will send you a price quote as soon as possible. If you have any further questions please do not hesitate to contact us at info@mechanical-projects.com - phone: 1.281.201.0302