TELEDYNE ANALYTICAL INSTRUMENTS

Fiber Optic Accessories


P/N 5017 - 1/2 Cross Flow Cell and Optical Interface Detectors (OICs)
The 1/2 fiber optic cross flow cell and two OICs are designed to contain flowing process gases or liquids. The flow cell is supplied with TFE ferrules as well as metallic ferrules so the customer can easily adjust the pathlength (0.1 - 2.5 cm). Inlet and outlet connections are 1/2 tube fittings. Materials of construction are 316SS, Sapphire or quartz, and viton or chemraz o-rings. The OICs can be designed for industrial or sanitary designs.

Covered under US patent #5,408,313

P/N 5014 - 3/8 Cross Flow Cell and Optical Interface Detectors (OICs)
The 3/8 fiber optic cross flow cell and two OICs are designed to contain flowing process gases or liquids. The flow cell is supplied with TFE ferrules as well as metallic ferrules so the customer can easily adjust the pathlength (0.1 - 1.5 cm). Inlet and outlet connections are 3/8 tube fittings. Materials of construction are 316SS, Titanium, Sapphire or quartz, and viton or chemraz orings. The OICs can be designed for sanitary applications.

P/N 5011 OIC, shown out of flow cell. Covered under US patent #5,408,313

P/N 5001 - Micro Flow Cell


The micro flow cell is designed to offer customers very small pathlengths without restricting flow. The micro flow cell offers adjustable OICs to easily adapt to higher absorbance concentration (0-50AU range) without diluting the sample. Typical pathlengths range from 1 mm down to 0.02 mm. Inlet and outlet connections are 3/8 tube fittings. Materials of construction are 316SS and quartz.

P/N 5010 OIC, shown out of flow cell. Covered under exclusive license from Glaxo-Welcome.

Fiber Optic Accessories

P/N 5002 - Bio-Tech End of Column Flow Cell


The bio-tech flow cell consists of a stainless steel block with an electropolished (RA 12 or better) interior, two fiber lensed OICs with 200u core fibers. The OICs and the sample inlet and outlet are held in the flow cell body with standard UPCHURCH fittings. Pathlengths available are from 1 cm down to 0.01 mm.

P/N 5009 OIC, shown out of flow cell.

P/N 5016 - Fluorescence Flow Cell


The process fluorescence flow cell is designed to be operated as a fluorescence and/or transmission flow cell. Standard fluorescence 90 optics are provided if you want to measure fluorescence and a third OIC is supplied if you want to add the transmittance feature. The benefit of this cell is that the customer can add a second spectrometer if both measurements are required simultaneously. Materials of construction are 316 SS, Viton, and quartz or sapphire windows. Adjustable pathlengths are available on the transmission side and micro optics are available on the 90 side if there is an inner filter effect from your samples. Process inlet/ outlet connections are 1/2 tube fittings.

Covered under US patent #5,408,313

P/N 5012F OIC, shown out of flow cell.

Fiber Optic Accessories

P/N 5018-XXX* - Long Pathlength Process Flow Cell


The long pathlength process flow cell is designed to make industrial measurements when longer pathlengths are required. Pathlengths as long as 500mm are available. Materials of construction are sapphire, quartz, viton or chemraz, and 316SS. OICs are provided with replaceable windows.

* designates pathlength in mm Covered under US patent #5,408,313

P/N 5013 OIC, shown out of flow cell.

Optical Interface Couplers


OICs are sold separately as stand alone items in support of spectrometers for industrial applications.

P/N 5013 P/N 5012 P/N 5011 P/N 5010 P/N 5009.

Fiber Optic Accessories

P/N 3503* - ATR Probe


The ATR probe is used when the absorbance of the sample is in the 4000 - 5000 AU/cm range. The ATR probe can be inserted directly into the sample and spectra taken without dilution. Typically the ATR probe is used on pure inks, dyes, and crude oil samples. Additionally the probe can be used as a general deposition probe if the RI of the material depositing on the probe tip is greater than the sapphire crystal. (Consult factory for application engineering assistance). The ATR probe is designed for process applications and has been tested up to 10,000 psig. The ATR probe can withstand temperatures up to 315 C. The ATR probe is a three bounce probe and the penetration of the evanescent wave is a function of the wavelength at which the measurements are made. Evanescent wave absorption permits the user to measure very high 3000 - 5000 AU/CM) absorbance samples.

* Patent pending

P/N 3502* - Front Surface Probe (Fluorescence or Reflectance)


The fluorescence / reflectance probe is used to determine the fluorescence or spectral reflectance (diffuse and specular) from the surface of a liquid, solid, past, or slurry. The probe is a special optical configuration designed to have a very sharp focus at the window and does not need to penetrate into the sample for a reading. The reflectance probe is 12 mm in diameter and can be inserted into a standard bench top fermenter via a PG-13.5 fitting. Front surface design focuses the energy at the distal tip of the probe.

* Patent pending

Fiber Optic Accessories

P/N 3501* - Transmission Probe


The transmission probe is a double pass probe that sends light energy from a source through the sample by folding the beam 180 back via a protected reflector. The amount of transmitted/ absorbed light is measured by the detectors, read out locally and a retransmitted 4-20mA output proportional to concentration is supplied. Transmission probes have traditionally been favored over transflection probes because of their increased linearity. Materials of construction are 316SS, viton or Kalrez, sapphire or quartz. Probe length can be increased if automatic retractable devices are required. Please inquire at factory.

Transmission probe*

* Patent pending

P/N 3800 - Automatic Probe Retraction Device, (APRD)


Designed for automatic insertion and removal of any of the Teledyne family of insitu probes. The APRD (designed by Welker Engineering) can be retracted hydraulically, via process fluids, or by an external air supply to insert and/or retract the probe from the process without shutting down the process. In addition, the APRD is supplied with a means of cleaning the probe with either steam or solvent. Cleaning can be done automatically based on spectral baseline shifting or on a fixed time basis ensuring continuous monitoring inside of a process line. Designed for ANSI 600 or 1200 lb flanges.

Fiber Optic Accessories

P/N 9002 - Fiber Optic Cuvette Holder


The fiber optic cuvette holder is used when running sample measurements in a traditional cuvette (up to 1, 2, 5 10 mm pathlength) remotely due to potentially hazardous consequences of sample exposure. The cuvette holder has a locking mechanism to hold the cuvette securely in place. Fiber connections are standard SMA-905 fittings.

P/N 9001 - Fiber Optic Coupler


Teledyne offers a simple transfer optic for the Agilent spectrometer. The fiber optic coupler easily fits into the same foot print as the existing sample cuvette holder supplied with the existing spectrophotometer. The fiber optic coupler is used to couple all of the energy from the spectrometer source into and out of fibers. Proper adjustment of this is via two XYZ axis adjustments. Attachment of any of the above fiber optic accessories now permits measurements to be made under remote (sample) conditions.

P/N 9003-XX - Laboratory Fiber Optic Dip Probe


Teledyne offers a laboratory fiber optic dip probe with replaceable tips. The dip probe is 1/4 in diameter and approximately 7 in length. The probe is supplied with two one meter fibers that connect to either spectrophotometers or other photometric devices. Replaceable tips are available in 2, 5, and 10 mm pathlengths. Materials of construction are 316SS and the optics are sealed with epoxy.

Fiber Optic Accessories


P/N 55T - Photo-X VIS Photometric Transmitter
The Model 55T covers all visible applications spanning 400nm up to 700nm. The unit can be supplied with either LEDs or a tungsten halogen lamp source. As shown, the transmitter can be packaged in a NEMA 4X enclosure, however it can also be supplied for Class I, Div 1 or Zone 1 areas. The transmitter is supplied with window fouling and automatic traceable reference filter for calibration. In addition the unit can operate in Absorbance or Linear Mode.

P/N 58T - Photo-X NIR Photometric Transmitter


The Model 58T covers all NIR applications spanning between 700nm up to 2000nm. The unit can be supplied with either LEDs or a tungsten halogen lamp source. The transmitter can be packaged in a NEMA 4X enclosure, however it can also be supplied for Class I, Div 1 or Zone 1 areas. The transmitter is supplied with window fouling and automatic traceable reference filter for calibration. In addition the unit can operate in Absorbance or Linear Mode.

P/N 53T - Photo-X UV-VIS Photometric Transmitter


The Model 53T covers all UV applications spanning between 200nm up to 650nm. The unit can be supplied with either LEDs or a Xenon flash lamp. The transmitter can be packaged in a NEMA 4X enclosure, however it can also be supplied for Class I, Div 1 or Zone 1 areas. The transmitter is supplied with window fouling and automatic traceable reference filter for calibration.

Fiber Optic Accessories

P/N 53F - Photo-X Fluorescence Transmitter


The Model 53F fluorometer covers the range of fluorescence excitation wavelengths between 210 - 550nm and emission wavelengths between 220 - 650nm. The fluorometer can be supplied with either a xenon flash lamp or a LED depending on the application. Packaging as shown to the right is in explosion proof purged SS enclosure but can be supplied in a NEMA 4X enclosure or on a stand for general purpose applications. The transmitter is supplied with window fouling and automatic traceable reference filter for calibration.

P/N 53P - Photo-X UV Portable Suitcase


The Model 53P portable suitcase can be either a fluorometer or a standard absorbance based device. The suitcase is supplied with preconfigured optics that specifically suits the need of the application. The transmitter is supplied with window fouling and automatic traceable reference filter for calibration.

P/N 5241 - Tungsten Halogen Lamp


The Model 5241 is a temperature controlled, optically regulated continuous tungsten halogen source that covers the range of 380nm to 2200nm. The unit is supplied with lamp diagnostics (LEDs that turn from Green to Red) alerting the user to lamp failure, pre-lamp failure / PM required, and a lamp low voltage warning. The unit is supplied in a general purpose housing but can be supplied for installation in specific area classifications. The 5241 can complement either the Photo-X VIS or NIR transmitters, or can act as a stand along device.

Fiber Optic Accessories

P/N 5249 - Du Lamp Assembly


The Du lamp assembly is the housing to hold the Du lamp and the fiber optic coupler that captures the light from the lamp and sends it down the fiber optic cable. The entire assembly is temperature compensated for stability of the lamp output. Fiber optic connections to the lamp are made with standard SMA-905 fittings.

P/N 5250 - Du Power Supply


The Du Power supply supplies a stable amount of power to the lamp. The power supply is powered by a 24V source.

P/N 5241 - Du Lamp


The Du Lamp is inserted into the lamp assembly by removing the four screws holding the lamp in place. The lamp is designed to be installed in one position and is keyed so proper alignment is insured. Lamps produce UV-VIS energy between 190 - 750nm.

Fiber Optic Accessories

P/N UVF-100 - Xenon Flash Lamp


This UV light source (200 - 850nm) is used for Fluorescence, Absorbance, or Reflectance applications. If the lamp is to be used for fluorescence, it is supplied with a filter holder which is attached to the lamp and allows the user to filter the specific excitation wavelengths. For other applications, the lamp can be supplied with special filters or lenses. The lamp and lamp power supply are sent as an integral unit. The Xenon Flash Lamp will operate continuously for a period of 2 to 4 years, depending on the flash rate. Fiber optic connections to the lamp are made with standard SMA-905 fittings.

P/N UV-200 - Mercury Lamp


The Mercury Lamp is designed to deliver 254nm energy onto a fiber optic cable. The lamp is held in place with a solid aluminum block. A separate power supply is required when this lamp is selected. Fiber optic connections to the lamp are made with standard SMA-905 fittings.