Professional Documents
Culture Documents
Flexi Multiradio Base Station Alarm Reclassification PDF
Flexi Multiradio Base Station Alarm Reclassification PDF
Page 1 of 2
Figure 7:
Fault situation 1:
1. TRX 1 becomes faulty and ceases to operate. 7606 TRX FAULTY alarm is issued.
Fault situation 2:
1. 2. 3. TRX 1 becomes faulty and ceases to operate. 7606 TRX FAULTY alarm is issued. TRX 2 becomes faulty and ceases to operate. Now both TRXs are not operating, which causes BTS 1 cease to operate. A BTS alarm, 7603 BTS FAULTY, is issued.
http://127.0.0.1:43231/NED/NED?service=printview&library=a25003a0000a770117...
07-06-2013
Page 2 of 2
When the TRX-2 becomes faulty, it raises a BTS object level alarm and not a 7606 TRX ALARM. Similarly for example, in a situation with 12 TRXs per BTS and all 12 TRXs going faulty, the 12th TRX that goes faulty raises a BTS object level alarm.
Fault situation 3:
1. 2. 3. TRX 1 becomes faulty and ceases to operate. 7606 TRX FAULTY alarm is issued. The performance of TRX 2 becomes degraded but calls are still possible with it. Now the sector is partially faulty, and a BTS alarm, 7604 BTS OPERATION DEGRADED, is issued.
Fault situation 4:
1. 2. 3. TRX 1 becomes partially faulty but calls are getting through. 7607 TRX DEGRADED alarm is issued. TRX 2 becomes faulty and ceases to operate. 7606 TRX FAULTY alarm is issued for TRX 2. 7607 TRX DEGRADED alarm is cancelled for TRX 1. Now the sector is partially faulty and a BTS alarm, 7604 BTS OPERATION DEGRADED, is issued.
http://127.0.0.1:43231/NED/NED?service=printview&library=a25003a0000a770117...
07-06-2013