(2) Reducing Corrosion. The two ways to reduce corrosion in in plumbing systems are Dielectric unions. Dielectric unions placed in the cold-and hot-water takeoffs from the tank can control gallvanic corrosion of water tanks. A dielectric union has a fiber washer, which insulates the tank from the rest of the plumbing installations, preventing the flow of current from the tank to the system. Magnesium rods. Magnesium rods are used in some water healers, such as the gas-operated type, to protect against rust and corrosion. They act as elctrolytic cells in which the magnesium particles go into solution, flow through the water, and are deposited on the metal to be protected. The electrolytic action (electrolysis) dissolves the rods. Eighteen months is considered the maximum life of the rods; then they must be replaced. b. Valve Repair. All valves should be checked regularly for leaks. Most leaks are from leaky washers or bonnets. Refer to Chapter 7, paragraph 7-2 (pages 7-3 through 7-6) for repairs. c. Faucet Repair. Refer to Chapter 7, paragraph 7-5 (pages 7-9 through 7-15) for faucet repairs. d. Temporary Repairs for Small Leaks. Small leaks in a system require temporary or emergency repairs. Before making any repairs, shut off the water and relieve the pressure from the system. Pipes can be temporarily repaired with one of the following methods:
3-2. Frozen Pipes. Water supply lines may freeze when exposed to temperatures below 32 F (0C). Outside pipes must be buried below the frost line. In northern zones, this is 4 feet or more. If building temperature falls below freezing, inside pipes may also freeze, causing the pipe to break at the weakest point. Use the procedures in Figure 3-1 for thawing above- and below-ground pipes.
3-2
FM 5-420
3-3
FM 5-420
3-3. Scale. Scale can sharply reduce the flow of water to fixtures. Scale is a result of hard water. Hard water contains a large amount of calcium and magnesium compounds which prevent soap from lathering. This forms a scum, which slows down the flow of water. The scum deposits harden and from scale. a. Reducing Scale. In localities where the water is unusually hard, a water softner is used to reduce the hardness. The softner normally contains zeolite, which must be recharged regularly. The recharge is done by adding sodium chloride (table salt) to the waler. Water softners are programmed to recharge at a set time each day. The softened water is then piped into the distribution system. b. Removing Scale. To remove scum that has formed on the inside of a pipe, do one of the following Flush with hot water. Use lye or lye mixed with a small quantity of aluminum shavings. Only cold water should be used with lye. For a sharp reduction of water flow, you may have to replace the entire pipe. NOTE: Chemical cleaners should not be used in pipes that are completely stopped up because the cleaners must contact the stoppage directly. 3-4. Waste-System Stoppages. A common problem in waste systems is a stoppage. A stoppage can occur in a fixture drain, floor drain, branch line, or main line. The cause can be hair, grease, or other foreign matter that holds back the flow of waste disposal. Use the proper clearing tool to clear the stoppage. These tools (Figure 3-2) are designed to clear stoppages in different areas of the waste system. These areas are a. Water Closets. Use the procedures in Figure 3-3. b. Lavatories and Sinks. Use the procedures in Figure 3-4 (pages 3-6 and 3-7). c. Urinals. A stoppage in a urinal with an exposed P-trap is cleared the same as a lavatory (using a plunger and a 1/4- to l/2-inch snake). A urinal with a waler seal is cleared the same as a water closed (using a plunger and a 1/4- to l/2-inch snake). d. Bathtubs. Use the procedures in Figure 3-5 (pages 3-8 and 3-9). e. Shower Drains. Use the procedures in Figure 3-6 (page 3-10). f. Branch and Main Waste Lines. Stoppages that occur in a branch or main waste line in a building are cleared through a cleanout. Use the procedures in Figure 3-7 (page 3-11). g. Grease Traps. All work is done on the principle that grease is lighter than water and will rise to the top of the water. To clear a grease-trap stoppage Step 1. Remove the top cover and dip out the grease with a ladle. Step 2. After the grease is scooped out, scrape the walls and bottom. Step 3. Flush with clear water.
3-4
FM 5-420
3-5
FM 5-420
3-6
FM 5-420
3-7
FM 5-420
3-8
FM 5-420
3-9
FM 5-420
3-10
FM 5-420
3-11