13 Series Electronic Step Relays 10 - 16 A

A range of step relays with an electronic circuit driving a relay output Rail 35 mm (EN 50022) or flange mount No internal wiring Control circuit can be used continuosly Longer mechanical and electrical life, and much quieter than electromechanical step relays Suitable for SELV applications (according to IEC 364 for type 13.21) 35 mm rail (EN 50022) or flange mount (13.21) Conforms to EN 60669-1 and EN 60669-2-1 Approvals (according to type): SEV

13

13 Series Electronic Step Relays 10 - 16 A

13.21

13.71

ELECTRONIC STEP RELAY 16 A TYPE 13.21 1 NO (SPST-NO) - Supply circuit, contact circuit and control circuit all separated and insulated from each other (SELV applications, IEC 364) - Connections: 6 wires - Low voltage electric control - Automatic reset after power cut - 35 mm rail (EN 50022) - LED indication: green = power ON red = relay ON - Ordering information: see page 16

ELECTRONIC STEP RELAY 10 A TYPE 13.71 1 NO (SPST-NO) - Can connect up to 15 ( 1 mA) illuminated push buttons - No wiring inside - Mounting bracket using two 3 mm screws - No-bounce electronics in the control circuit - Automatic reset after power cut - Ordering information: see page 16

58.6 36 45.6 13

50 39 22

19.6

86.9

44.8

84

49.5

SEQUENCES
TYPE 13.21 number of step 2 SEQUENCES
1 2 3 4

13.71
14

19.6

6.5

7.2

8.2

8.2

8.2

4.5

13 Series Electronic Step Relays 10 - 16 A


WIRING DIAGRAMS FOR TYPE 13.21 RELAY
110/230 V VERSIONS (AC only) L N L N 12/24 V VERSIONS (AC/DC)

A2 A1

A2- A1+ 1

13.21
ON

13.21
ON

P1 P2

P1 P2

Relay with SELV supply control circuit

Relay suitable for SELV supply voltage

WIRING DIAGRAMS FOR TYPE 13.71 RELAY


L N L N

13.71

13.71

max 15 illuminated push-buttons ( 1 mA)

max 15 illuminated push-buttons ( 1 mA)

3 - wire connection

4 - wire connection

15

13 Series Electronic Step Relays 10 - 16 A


TECHNICAL DATA
13.21 SUPPLY VOLTAGE UN OPERATING RANGE DIELECTRIC STRENGTH - between control circuit and supply: - between control circuit and contacts: - between supply and contacts: - between open contacts: MAXIMUM SWITCHING FREQUENCY - without load: - at rated load: MECHANICAL LIFE MAXIMUM IMPULSE DURATION AMBIENT TEMPERATURE PROTECTION CATEGORY POWER LOST IN THE ENVIRONMENT - without load: - at full load: 1.5 W 3.5 W 0.5 W 2.9 W 3,600 operations/h 900 operations/h 20 106 cycles continuous (10...+60)C IP 20 3,600 operations/h 1,800 operations/h 5 105 cycles continuous (10...+60)C IP 20 3,750 V (versions 110/230 V) 3,750 V 3,750 V 1,000 V 1,000 V 12 - 24 V AC (50/60 Hz)/DC 110 - 230 V AC (50/60 Hz) AC: (0.8...1.1)UN DC: (0.9...1.1)UN 13.71 230 V AC (50/60 Hz) (0.85...1.15)UN

CONTACT SPECIFICATIONS
13.21 RATED CURRENT MAX PEAK CURRENT RATED VOLTAGE MAX SWITCHING VOLTAGE NOMINAL RATE IN AC1 NOMINAL RATE IN AC15 (230 V) NOMINAL RATE of lamps at 230 V AC - compensated fluorescent lamps - uncompensated fluorescent lamps: - incandescence lamps: - halogen lamps: ELECTRICAL LIFE CONTACT MATERIAL 750 W 1,000 W 2,000 W 2,000 W 100 103 cycles AgSnO2 350 W 500 W 1,000 W 1,000 W 100 103 cycle AgSnO2 16 A 30 A 250 V AC 400 V AC 4,000 VA 750 VA 13.71 10 A 20 A 230 V AC 2,300 VA 450 VA

ORDERING INFORMATION
Example: a 13 series, electronic step relay, rail 35 mm (EN 50022) mount and 1 NO (SPST-NO) - 16 A contact, with 230 V AC supply.

1 3
Series

2 3 0

No. of poles 1 = Single phase switch 1 NO (SPST-NO)

Coil version 0 = AC (50/60 Hz)/DC* 8 = AC (50/60 Hz)

Type 2 = 35 mm rail (EN 50022) mount 7 = Panel mount (3 or 4 wires)

Coil voltage 012 = 12 V AC/DC ** 024 = 24 V AC/DC ** 110 = 110 V AC ** 230 = 230 V AC

* for 13.21.0.012 and 13.21.0.024 only ** for 13.21 only