Frequency response analysis is the world wide accepted standard test for detecting electrical and mechanical changes of the core and winding assembly of power transformers without costly de-tanking. It is common to perform this test in the factory and then again following delivery to site to determine and compare the transformer frequency response signature. Megavar engineers use the Omicron FR Analyzer to provide accurate and detailed results for clients including Wilsons Transformers and ABB Transformers. Transformer and Switchgear High Voltage Testing Does your high voltage system require extension or upgrade? Whether it be a transformer replacement or installing a new power station or substation, Megavar has the personnel, expertise, and equipment to perform all necessary protection and high voltage testing. Do you have a high voltage testing and condition monitoring program for your high voltage assets? Have you considered what the direct and indirect costs may be, if a major electrical failure occurs in your HV system? If you answered no or do not know, then perhaps it is time to consider establishing high voltage testing and condition monitoring programs on your critical HV plant. Megavar can assist with the development and scoping of a suitable testing regime, as well as providing all high voltage testing and condition monitoring services.

Dirana Dielectric Loss Angle IR and PI DC Winding resistance Turns Ratio Test

converted by Web2PDFConvert.com

Vector Group Relationship Leakage Reactance/Impedance Excitation Current Tap Changer Continuity High Voltage Applied Testing SFRA (Sweep Frequency Response Analysis)
Footy Tipping

Hire this service

Other services
VT Testing Current Transformer Testing HV Cable Testing HV Circuit Breaker Testing HV Transformer Testing HV Motor & Generator Testing Earth Testing & Design Protection Relay Testing Online Partial Discharge Testing Distribution Design and Construction Cable Jointing Project Services HV Electrical Construction Power System Design SCADA Engineering Thermographic Imaging SF6 Leak Detection - IR Imaging
converted by Web2PDFConvert.com

Line Testing

GENERAL ENQUIRIES
Telephone: 1300 730 499 Enquiries: ofce@megavar.com.au Services: service@megavar.com.au All Technical enquiries and questions relating to prospective projects, jobs and resources. Accounts: accounts@megavar.com.au Please direct all account queries, payable & receivable, to this email.

OFFICES
Hobart - Head Ofce Unit 8/Tech 5 30-38 Innovation Drive, Dowsing Point, TAS 7010 Melbourne Ofce 12/41 Sabre Drive, Port Melbourne, VIC 3207 Perth Ofce 324 Great Eastern Hwy Ascot WA 6104 Brisbane Ofce Level 36, Riperian Plaza 71 Eagle Street, Brisbane QLD 4000 Launceston Ofce 89 Talbot Rd, Launceston, TAS 7249 Maryborough Ofce 388 Kent Street Maryborough, QLD 4650

LICENCES
Tasmania - 947267 Victoria - 21203 Queensland - 73595

Webmail

NS Login

SP Login

Privacy Policy

Scroll to top Copyright 2013 Megavar Pty Ltd. All rights reserved

converted by Web2PDFConvert.com

converted by Web2PDFConvert.com

You might also like