Dust Suppression Sys - Coal Wagon Unloading
Dust Suppression Sys - Coal Wagon Unloading
Dust Suppression Sys - Coal Wagon Unloading
Dt:
Ultratech Cement, MTPA Cement Plant Penta Project Coal Handling System (Specification for Dust Suppression system at Coal unloading hopper) Description Bidder's information Company name Contact person Telephone number Fax number Email Proposal number Revision General Plant Conditions Temperature Maximum Minimum Altitude Units
Required
Vendor's Proposal
C C m above MSL mm % Zone-II (as per IS :1893 part 1 2002) m/s As per IS:875 (part III) 1987
Rainfall (Annual) Relative humidity Seismic Zone Wind (at ground level) Bidder's scope of Supply Water tank Pump Electric motor Pipes incl. fittings
meters Size of Tippler hopper Discharge time for Tippler Railway gauge Angle of tip/rotation Tipping Capacity Operating Material Flow rate Material Properties Material Size Bulk Density Volume Power Moisture Angle of repose Abrasiveness Dust suppression system consist of Water Tank Type Capacity / Volume Ball valve Size Solenoid valve size Float valve size Pumps Incl. mounting skid, inlet and outlet fittings, NRV Discharge @ 9 kg pressure Delivery Head Electric motor kW / rpm (Incl. control panel + on / off start / provision for earth leakage + dry run protection + overload relay. Pressure gauge for online sit pressure calibration > 10 bar Safety relief valve With 1 end connection @ 15 bar pressure Y strainer end connection MOC-MS with SS 250 mesh cleanable filter insert
LxWxH Seconds MM DEG tips/Hr TPH Text mm T/m3 T/m3 % deg Text
SINTEX / RCC m3 mm mm mm
Vendor to specify Vendor to specify Vendor to specify Vendor to specify Vendor to specify
LPM LPM m
Vendor to specify Vendor to specify Vendor to specify Vendor to specify mm Vendor to specify Vendor to specify
2 of 4
Sprinkler Incl. pipe , fitting , valve & supports Guards Provided by Vendor Code used for design (e.g., OSHA, MSHA) Removal method (e.g., bolted) Locations Other Pipes included Fittings included Supports included Recommended spare parts Special tools Vendor to test operation of installed equipment INSTRUMENTATION AND CONTROLS General Information Power supply Voltage / Frequency / Phases Load Control Voltage Voltage / Frequency / Phases
240; 50 Hz; 1 phase VAC for MCC and 24 VDC for PLC control yes
All control voltages internally derived with suitable isolated 100% redundant control transformers Signal types Discrete Type Rating Analog CONTROL SYSTEM - PLC Provided by Vendor Software Provided by Vendor Weights
Water tank Pump (including electric motor) Miscellaneous Total weight of System