Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Pre-Construction Report

GlenMartin Holding Co., LLC


SITE VISIT INFORMATION
Site Name:
Site Number:
Contractor Name:
Address:
City/State:
Inspection Completed By:
Date of Inspection:
Contact Phone Number:
Client/Customer Name:
Address:
City/State:
Contact Name:
Contact Phone Number:

BLUE MT
TX-5076
GlenMartin Holding Co., LLC
1604A Business Loop I-70W
Columbia, MO 65202
Jack Ray, Above All Tower Climbing, LLC
2/14/2013
314-496-2406
Global Tower Partners
www.gtpsites.com

866-487-8977

GENERAL SITE INFORMATION


Global Tower Partners
www.gtpsites.com

Site Owner Name:


Address:
City/State:
Contact Name:
Contact Phone Number:
Site Address:
City/Sate
Latitude:
Longitude:
Gate Combo:

866-487-8977
Blue Mountain Peak Ranch Rd
Mason, TX
30.56472222
-99.45361111
1801

TOWER INFORMATION
Structure Type:
Tower Height:
Overall Structure Height:
Tower Manufacturer:
Number of Tower Legs:
Climbing/Safety Device:
FCC/ASR Number:
AM Detuning ? :

Guyed
199'
201'
Unknown
3
Pegs on one side of "A" Leg with Safe Climb Cable
1047020
N/A

ADDITIONAL INFORMATION
Notes: Inspected tower to measure for diminsions for installation of structural reinforcement. Also noted is additional maintenance that needs to be addressed, see below fo
more detail. Site is approximately 1.8 miles from gate and sign. Must access through a second gate, then proceed an additional 1/4 to 1/2 mile to tower.

Regardingstructuralreinforcement: Existinghorizontalsareflat,anglesteel.Thehorizontalsinthespecifiedareaareallunobstructedwiththeexceptionof
one ThehorizontalontheA/BFaceofthetower,facingnorth@185'hasthreecoaxlinesattachedtoit.

Additionalmaintenanceneededtobeaddressed:(1) Towerpainthasdeterioratedtoapproximatelyonly5%to10%ofthetowercovered.Ref.picTX
5076.2. (2)Noneofthecoaxispainted.Ref.picTX5076.2(3) Thereisnoicebridgeprotectingthecoaxrunningfrombuilding#2.Ref.picTX5076.4.(4)
Climbingpegsareonlylocatedonthesouthsideofthe"A"leg.Thismakesitextremelydifficult,almostcounterproductivetousethesafeclimbcablewhen
ascendingthetower.Notallholesarepresentforpegsonthenorthsideofthe"A"leg.Holesmustbedrilledtoinstallpegs. (5) Guywiresafetycableoffof
the"A"legwastooshortandnotconnected.Atemporarycablewasinstalled.Ref.picAddt'l1and10.(6) UBoltmissingfromhorizontalbrace@5'.Ref.pic
Addt'l2(7) Concreteonsurfaceoffoundationhasdeterioratedtothepointoftherebarbeingexposed.Ref.picAddt'l3and4(8)Severaloftheholesonthe
guymountsonthetoweraremismatchedandtheboltsarenotflush.Holesshouldbedrilledoutandappropriatesizedboltsplacedinholesthatwill
properlytighten.Ref.picAddt'l6andTX5076.8.(9)Severalboltsaremissingfromtheguymountsonthetower.Thisismostlikelyduetothemissmatched
holes.Ref.picAddt'l7,Addt'l8,andAddt'l11.

Guyed Tower
Site Name:
Site Number:
Inspection Completed By:
Date of Inspections:

BLUE MT
TX-5076
Jack Ray, Above All Tower Climbing, LLC
2/14/2013

GlenMartin Holding Co., LLC

Tower Base Information


Foundation Shape:
Foundation Size:
Base Plate Shape:
Base Plate Dimensions:
Base Plate Thickness:
Base Plate Grouted?:
Base Plate Stiffeners?:
Quantity:
Height:
Width:
Thickness

Tri-Angle
3'x3'x3'
Square
6"X6"
1/2"
No
No
N/A
N/A
N/A
N/A

Anchor Bolt Size:


5/8"
Anchor Bolt Quantity:
3
Anchor Bolt Pattern:
Single bolt per plate
Anchor Bolt Separation:
N/A
Which leg/face is the ladder/pegs on?
A
Height of pivot section:
N/A
Azimuth of "A" Leg?:
270 degrees
Center to center face width @ bottom:
36"
Face width @ taper change:
N/A
Elevation of taper change:
N/A
Face width @ top:
36"
Leg splice type (flange, lap, butt)
Flange with 1/2" Bolts

Tower Section Diagrams


See Additional

Site Name:
Site Number:
Inspection Completed By:
Date of Inspection:

BLUE MT
TX-5076
Jack Ray, Above All Tower Climbing, LLC
2/14/2013

GlenMartin Holding Co., LLC


PHOTO LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

TX-5076.1- Site Sign


TX-5076.2- Over All Site
TX-5076.3- Site Building 1
TX-5076.4- Site Building 2
TX-5076.5- Tower Foundation
TX-5076.6- Tower Section Connecting Flange with bolt spacing
TX-5076.7- Bottom of Guy Mount at 184'
TX-5076.8- Top of Guy Mount at 189"
TX-5076.9- 180' Mark on Tower
TX-5076.10- 191' Mark on "A" Leg with Safe Climb Attachment
TX-5076.11- Coax Mounted on North Side of "A" Leg @ 185'
TX-5076.12- Antenna Mount @ 185'-8" on "B" Leg
TX-5076.13- Antenna @ 185'-8" on "B" Leg
Addt'l 1 Guy Safety Cable not connected
Addt'l 2 U-Bolt missing from add-on horizontal
Addt'l 3 Foundation deteriorated on "A" corner, re-bar exposed
Addt'l 4 Foundation deteriorated on "C" face, re-bar exposed
Addt'l 5 No ice bridge protecting coax from Building 2 to tower
Addt'l 6 Bolt Holes misaligned on guy mounts
Addt'l 7 Bolts Missing from lower guy mount
Addt'l 8 Bolts missing from upper leg of guy mount
Addt'l 9 Coax not secured below topmost antenna (blowing in wind)
Addt'l 10 Temporary safety cable installed on guy anchors
Addt'l 11 Secured Coax to tower

72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141

TX5076.1TX5076.2

TX5076.3TX5076.4

TX5076.5TX5076.6

TX5076.7TX5076.8

TX5076.9TX5076.10

TX5076.11TX5076.12

TX5076.13Addtl1

Addtl2Addtl3

Addtl4Addtl5


Addtl6

Addtl7

Addtl8

Addtl9

Addtl10

Addtl11

45"

You might also like