Heat Exchanger Application Data Sheet


Davidson Sales Company
SALES OFFICE

Date:

839 Bill France Blvd


ADDRESS

Daytona Beach, FL 32117


CITY/STATE/ZIP

386-274-2079
TELEPHONE

386-274-2279
FAX

dsc@davidsonales.com
EMAIL

Please complete the following installation and product information and forward to your Young Touchstone sales office for a heat exchanger to meet your specifications.
NAME CITY TELEPHONE COMPANY STATE FAX ZIP EMAIL

Heat Exchanger Type:

F Style F-800-R4 Fixed Tube Bundle

HF High Pressure HI-FIN Finned Tube Bundle

SSF Stainless Steel RFF Finned Tube Bundle

Please provide your cooling system needs and installation requirements in the following selections:
Application Details:
Heat Load Shell Fluid Type

Program Field
BTU/MIN FCS

Units
BTU/Min SAE-10 Water Polyglycol Ethylene Glycol SAE-20 MIL-H-5606 Phosphate Ester % Propylene Glycol % SAE-30 MIL-L-23699 SAE-40 #2 Diesel Fuel SAE-50

Other (if other is selected, please complete Shell Side Optional Tube Fluid Properties fields below) Shell Fluid Flow Rate Shell Fluid Inlet Temperature Shell Fluid Outlet Temperature Shell Side Maximum Pressure Drop Shell Side Fouling Factor Tube Fluid Type GPMS TSI TSO MXDPS FFS FCT GPM F O F psi hr-ft2-F/Btu
O

SAE-10 Water Polyglycol Ethylene Glycol

SAE-20 MIL-H-5606 Phosphate Ester %

SAE-30 MIL-L-23699

SAE-40 #2 Diesel Fuel

SAE-50

Propylene Glycol

Tube Fluid Flow Rate Tube Fluid Inlet Temperature Tube Fluid Outlet Temperature Tube Side Maximum Pressure Drop Tube Side Fouling Factor

GPMT TTI TTO MXDPT FFT

Other (if other is selected, please complete Tube Side Optional Tube Fluid Properties fields below) GPM O F O F psi hr-ft2-F/Btu

Optional Tube Fluid Properties: (NOTE: Fluid properties are required for any fluids not currently on file at YT.) Shell Side: Tube Side Fluid Specific Gravity SGS Fluid Specific Gravity Fluid Specific Heat CPS Btu/lb-F Fluid Specific Heat Fluid Thermal Conductivity KS Btu/hr-ft-F Fluid Thermal Conductivity Fluid Viscosity MS Centipoise Fluid Viscosity Please complete the following if tube fluid is: Compressed Air Relative Humidity Inlet Air Temperature Compressed Air Pressure Saturated Steam Steam Pressure

SGT CPT KT MT

Btu/lb-F Btu/hr-ft-F Centipoise

%RH TAMB PRES

% O F psig

PRES

psig

Please describe any additional design requirements:

168423038.xls.ms_office Revised October, 2005

Procedures to Utilize the C ooling System Application Data Sheet


Overview The Data Sheet has been designed to capture all necessary data for Young Touchstone to provide a cooling system solution based on various selections entered by the end user. The Data Sheet has several cells that are protected in order to prevent any accidental data entry. When entering information in the Data Sheet, use the following as a guide to easily maneuver through the document: 1) Use the Tab key and scroll left to right from one field to the next. (You can also position your mouse in the field you would like to go to, however, if you attempt to click into a cell that is protected, it will not allow you to do so). 2) Where there are Check Boxes, position your cursor over the check box and left click once to select. To remove the check mark, left click again and it will be removed.