Professional Documents
Culture Documents
Flow Meter Product Catalogue
Flow Meter Product Catalogue
Page 2
Overview
JSG provide a range of oval gear flow meters which provide high levels of accuracy and repeatability for a wide range of clean liquids irrespective of viscosity and conductivity.
Metal rotors provide ultimate rotor stability
Features
No requirement for flow conditioning Wide turndown (min.~max. flow) High accuracy, repeatability and reliability Ultimate rotor stability Dual outputs (reed and hall effect) standard Pulse high resolution pulse output Hazardous area versions Bi-directional flow capability Quadrature pulse output option Modular process connections
Pulse with high resolution and dual outputs (standard) Quadrature pulse output option
Applications
Acids Alcohol Water Fuel Oils Diesel Liquid Propane Tallow Paint Pharmaceuticals
Pesticides Solvents Chemicals Beverages Vegetable Oils Inks Adhesives Hydraulic Oil Resins
Modular Process Connections
Principle of Operation
The Oval Gear meters are positive displacement flow meters where the passage of liquid causes two oval gears to rotate within a precision measuring chamber and with each rotation a fixed volume of liquid passes through the meter.
Page 3
General Specifications
Flow range Nominal sizes Linearity Repeatability Temperature Materials Pulse outputs 0.5~550 L/hr 4~8mm ( 1/8~3/8 ) +/-1% of reading +/-0.03% of reading - 40C~+120C (150C max using Hall output) 316 stainless or aluminum Reed switch & Hall effect output (standard)
Standard Options
LCD totaliser LCD flow rate totaliser LCD two stage batch controller Intrinsically Safe (I.S.) instruments (ATEX/IECEX) 4~20mA, scaled pulse and alarm outputs Quadrature pulse output Explosion proof Exd (ATEX/IECEX) Mining Exd (stainless steel meters only) (ATEX/IECEX)
Features
High resolution for precise measurement Simple to install and wire Dual outputs to suit most applications Precision Carbon-Graphite bearing
(See ancillaries for further details on integral and remote options) Note: Not available with Mechanical Registers. Pulse Meter with B11 Totaliser
Page 4
General Specifications
Flow range Nominal sizes Linearity Repeatability Temperature Materials Pulse outputs 1~580 L/min 15~50mm ( ~2 ) +/-0.5% of reading +/-0.03% of reading - 40C~+120C (150C max using Hall output only) 316 stainless or aluminum Reed switch & Hall effect output (standard with pulse meters) Medium Capacity Blind Pulse Meter
Standard Options
Modular process connections LCD totaliser LCD flow rate totaliser LCD two stage batch controller Intrinsically Safe (I.S.) instruments (ATEX/IECEX) 4~20mA, scaled pulse and alarm outputs Integral mechanical totaliser / batch register Quadrature pulse output Explosion proof Exd (ATEX/IECEX) Mining Exd (stainless steel meters only) (ATEX/IECEX)
Features
High flow rangeability Modular construction aids installation Precise batching Easy to read LCD or mechanical displays Choice of output suits most applications
NMI Approved
Pulse meters, sizes 25mm to 100mm Limited to bulk metering of AdBlue and petroleum based products with viscosity less than 20cps at 20C
Page 5
General Specifications
Flow range Nominal sizes Linearity Repeatability Temperature Materials Pulse outputs 35~2500 L/min (13~625 USGPM) 80 & 100mm ( 3 & 4 ) +/-0.5% of reading +/-0.03% of reading - 40C~+120C (-4~250F) (150C max using Hall output only) Aluminum Reed switch & Hall effect output (standard with pulse meters) Large Capacity Blind Pulse Meter
Standard Options
Modular process connections LCD totaliser LCD flow rate totaliser LCD two stage batch controller Intrinsically Safe (I.S.) instruments (ATEX/IECEX) 4~20mA, scaled pulse and alarm outputs Integral mechanical totaliser / batch register Quadrature pulse output Explosion proof Exd (ATEX/IECEX) Mining Exd (stainless steel meters only) (ATEX/IECEX)
Features
Modular process connections Compact and light weight High flow capacity Modular construction aids installation Easy to read LCD or mechanical displays High resolution or Quadrature pulse outputs
NMI Approved
Pulse meters, sizes 50mm to 100mm Limited to bulk metering of AdBlue and petroleum based products with viscosity less than 20cps at 20C
Page 6
Page 7
5 Digit Resettable Totaliser and 8 Digit non resettable totaliser Repeatability: 0.05% of reading over entire range and beyond The mechanical counter registers total volume of liquid Finished in corrosion resistant epoxy, the housing protects the register in demanding environments and extremes in weather Positive action reset knob
Provides an imprinted ticket record of each transaction Printer is incorporated with V1 mechanical register and must be ordered together Tamper proof design seals ticket in printer during delivery Security is provided by before and after imprinting of consecutive sales (transactions) number Magnetic latch and gasketed cover keep out dirt and weather Right hand reset feature Printer accepts standard 128.8 x 196.9mm carbon packs and receipt tickets Reset knob resets both printer and register
Operating Temperature -40C to 80C Preset - 5 Digits 13mm High numbers Register - 5 Digit Reset 19mm high numbers 8 Digit non reset 3mm high numbers
Page 8
M3 Register
General Specifications
Model prefix : Nominal size ( inches ) Materials OM025 1 OM040 1 316 S/S OM050 2 OMO50E 2 OMO80 3 316 S/S Aluminium body Minimum delivery (liters) Maximum flow (L/min) Output options 6 150 15 250 30 500 35 580 35 750 50 1000 75 1500 150 2500 OM080E 3 OM100 4 OM100E 4
Pulse meter with wafer check valve, air eliminator and strainer
Page 9
Viscosity -
N D Shear rate
Liquid SG cp ADHESIVES Box Adhesives PVA 1 1.3 3000 100 BAKERY Butter melted Egg, whole Frosting Lecithin Condensed Milk Yeast Slurry 15% 1.3 1 0.98 0.5 1 10 @ 60C 60 @ 10C 10000 3250 @ 50C 10000 @ 25C 180 BEER Beer Yeast 80% solids 1 1.1 @ 5C 16000 @ 5C CONFECTIONARY Caramel Chocolate Fudge, Hot Toffee 1.2 1.1 1.1 1.2 400 @ 60C 17000 @ 50C 36000 87000 COSMETICS, SOAPS Face Cream Hair Gel Shampoo Toothpaste Hand Cleanser 1.4 10000 5000 5000 20000 20000 DETERGENTS Concentrate 10 DYES & INKS Ink, Printers Dye Solvents 1.38 1.1 0.8~0.9 10000 10 0.5~10 T N N N T T T T T Black Liquor Tar Paper Coating 35% Sulphide 6% Black Liquor Black Liquor Soap Auto Paint Solvents Varnish Turpentine T T T N T N N T T N T Black Bean Paste Cream Style Corn Tomato Sauce Tomato Paste 33% Pablum Pear Pulp Potato Mashed Prune Juice Orange Juice Conc. Mayonnaise Honey Polyester Resin PVA Resin T T Caster Oil Cough Syrup Key Liquid
SG
cp PHARMACEUTICALS
Key
0.96 1.00
N N
1.40 1.30
1.11 1.14
1 1 1.1 1 1.5
0.5~10 140 @ 40C 2 @ 15C PAPER & TEXTILES 2000 @ 150C 400 1600
N T N
1.3
Page 10
Pressure Drop Curves for Standard & Special Cut Oval Rotors
Page 11
Features / Benefits
High accuracy and repeatability, direct reading flow meter No requirement for flow conditioning ( straight pipe runs ) Measures high and low viscosity liquids Quadrature pulse output option and bi-directional flow Integral 4-20mA output option Optional NMI Pattern Approval (Australia Only)
Meter Selection
Blind Pulse Meter
PPS meters are used for non-aromatic/non-halogenated chemicals, water based liquids, Diesel Exhaust Fluid and petroleum products including oils and grease, fuels and fuel oils. PPS meters with standard ceramic rotor pins are suitable for applications where stainless steel is not suited or permitted. Blind pulse meters are available with Reed Switch and Hall Effect outputs. Quadrature pulse and Integral 4-20mA outputs are optional.
Integral Instruments
Chemical meter options include integral LCD totalisers, flow rate totalisers and batch controllers. These instruments provide monitoring and control outputs including 4~20mA, scaled pulse, alarms and batch control: Norequirement for flow conditioning (straight pipe runs)
BT LCD 5 digit reset, 8 digit cumulative totaliser. RT12 LCD 6 digit reset, cumulative totaliser and flow rate. Analogue and pulse outputs RT40 LCD 6 digit reset, cumulative totaliser and flow rate. Backlit Display. EB LCD 6 digit 2 stage batcher and cumulative totaliser.
Pulse Meter with LCD Register
(Instruments also available for remote mounting and with I.S. approvals)
General Specification
Flow range Size Meter Body Meter Cap Rotors Rotor Pins 10 ~ 150L/min. (2.6~ 40 US gal/min) 25mm (1NB) Glass Reinforced PPS (Ryton) Glass Reinforced PPS (Ryton) Glass Reinforced/Teflon Filled PPS (Ryton) Ceramic (High Purity Alumina, AL203)
Note: For all inquiries relating to a chemical meter please consult a JSG representative
Page 12
General Specifications
Model prefix : ES025 Nominal size (inches) 1 ES040 1 ES050 2 ES080 3 ES100 4
Materials Aluminium body, 316SS basket, viton seals Strainer mesh sizes 80 mesh (180 micron) Maximum pressure 10 bar (147psi) Air release head Dual port double reed valve Venting capacity @ 10psig 154 CFM (4.36M 3/min@ 70kpa) Note: The strainers and air eliminators are available for use with NMI applications. *National Measurement Institute Australia Air eliminator strainer
Y Type Strainers
General Specification
Body Screen Packing Working Pressure End Connections ASTM A-A-351 Grade CF8M 316 S/S 1mm perforations PTFE 40 bar (580psi) Threaded Female
Materials List
No. 1 2 3 4 5 6 Part Name Body Screen Gasket Bonnet O-Ring Plug Material CF8M SS316 PTFE CF8M Viton CF8M
Mesh Size 200 mesh 200 mesh 100 mesh 100 mesh 100 mesh 100 mesh 40 mesh
Size (mm)
1 3 1
4 (6mm) Note: For information regarding pressure drop across Y type strainers, contact your JSG Representative
8 (8mm) 2 (15mm)
Page 13
ROTORS / BEARINGS
Select based on the viscosity of the fluid and fluid type
Bearings for 316 SS and Aluminium Rotors. No Bearings required for PPS Rotors Register plate
6
CABLE ENTRIES
No cable entry for all mechanical meters
O-RING MATERIAL
To be chosen based on the fluid type
a
PROCESS CONNECTIONS
Based on desired pipe connection
TEMPERATURE LIMITS
80C for all mechanical meters (standard)
V1 REGISTER
Mounted with the gearbox and has a 5 digit resettable display also with an 8 digit cumulative total with an accuracy of 0.5% V-Series Register
GEARBOX ASSEMBLY
All V-series register require a gearbox that mounts directly on the meter.
Note: Body and sizes change with selection. Please refer to page 8 for other V series options and page 15 for coding with meter. Contact you JSG Representative for further assistance.
Page 14
A E S
Body Material Aluminum Extended flow aluminum version (OM050E, OM080E & OM100E only) 316L Stainless Steel Rotor Material PPS - Teflon Filled (Polyphenol Sulfide) PPS Rotors - Keishi cut (for high viscosity fluids) Aluminum (aluminum meters only) Stainless steel (stainless steel meters only) Aluminum - keishi cut for high viscosity liquids Stainless steel - keishi cut for high viscosity liquids Bearing Type No bearing - PPS rotor option only Carbon-graphite bearing (standard with stainless steel rotors) Hardened steel roller bearings (aluminum rotors only) O-ring Material Viton (standard), -15C EPR (Ethylene Propylene Rubber) - for ketones only (-40C) Teflon encapsulated viton - application specific (-15C) Buna-N (Nitrile), -40C Temperature Limits 80C max. Standard across all Mechanical Meters Process Connections BSPP (G) female threaded NPT female threaded Tri-clamp hygienic ferrules (Tri-clamp ferrules are larger than the meter size) ANSI-150 RF flanges ANSI-300 RF flanges PN16 DIN flanges JIS 10kg/cm2 flanges Customer nominated Cable Entries No cable entry. Standard across all Mechanical Meters
0 1 4 5 6 7
0 1 4
1 2 3 4
1 2 3 4 5 6 7 9
6 Totaliser Capacities OM015~025 OM040~100 9999.9 Litres 99999 Litres 7 OM050~100 99999 Litres 99999 Litres 99999 Litres 99999 Litres
M3
Integral Options 4 digit mechanical totaliser - Litres Large Digit Mechanical Registers (V-Series Registers) 5 digit mechanical reset register - Litres 5 digit register + 7888 ticket printer - Litres 5 digit register + preset batch register - Litres 5 digit register + preset + 7888 printer - Litres Specific build requirement
V1 V3 V5 V7 SB
Page 15
ROTORS / BEARINGS
Select based on the viscosity of the fluid and fluid type
Bearings for 316 SS & Aluminium Rotors. No Bearings required for PPS Rotors Magnets in Rotors send signals to PCB Board 3-6mm cable gland. Available with B2/B3 ONLY
O-RING MATERIAL
To be chosen based off the fluid type
a b
PROCESS CONNECTIONS
Based on desired pipe connection
TEMPERATURE LIMITS
Operating and Start-up temperatures required for PCB board selection
CABLE ENTRIES
Choose desired method of cable entry
INTEGRAL OPTIONS
NPT
M20 x 1.5mm
FRT12
FRT40
Note: Body and sizes change with selection. Please refer to page 17 for coding with meter. Contact you JSG Representative for further assistance.
Page 16
*(1) 120C (250F) rating for the pulse meter, 80C (180F) rating with BT, RT & EB options. See temperature code 5 for higher temperature with BT, RT, & EB *(2) Cooling fin is fitted with LCD instruments for operation between 80~120C (180~250F)
4 (100mm) 75 ~ 1500 L/min 20 - 400 GPH 4 extended flow (100mm) 150 ~ 2500 L/min 40 - 660 GPH Body Material - A Aluminum - E Extended flow aluminium version (OM050E,OM080E,OM100E only) - M Intermediate pressure aluminium meter (Only OM025 =138 Bar [2000psi] max.) - S 316 stainless steel - N Intermediate press. 316L SS meter (OM004N ~ 025N = 100bar, OM040N= 50bar, OM050N = 50bar) - H High pressure 316 SS (OM004H ~ 040H = 400bar [5580psi] max. OM050H = 300bar max.) Rotor Material 0 PPS - Teflon Filled (Polyphenylene Sulfide) 1 PPS Rotors - Keishi cut (for high viscosity fluids) 4 Aluminum (aluminium meters only). Only available in models OM015 and larger 5 Stainless steel (all standard OM004 ~ OM008 meters and all stainless steel models only) 6 Aluminum - keishi cut for high viscosity liquids 7 Stainless steel - keishi cut for high viscosity liquids Bearing Type 0 No Bearings (When selecting PPS Rotors) 1 Carbon-graphite bearing (standard with stainless steel rotors) 4 Hardened steel roller bearings (aluminum rotors only) O-ring Material 1 Viton (standard), -15C min. (-5F) 2 EPR (Ethylene Propylene Rubber) - for ketones only -40~+120C (-40~+250F) 3 Teflon encapsulated viton - application specific -15C min. (-5F) 4 Buna-N (Nitrile), -40~+100C (-40~+121F) Temperature Limits - 2 120C max. (Reduced to 80C with integral instrument) - 3 150C (300F) max. - (Hall Effect output only) (OM004~OM080) - For O-ring Code 1 & 3 only, not applicable with PPS - 5 120C (250F) max. (Includes integral cooling fin) see note 2 - 8 80C for OM008 and PPS Process Connections 1 BSP (RP) female threaded 2 NPT female threaded 3 Tri-clamp hygienic ferrules (Triclamp ferrules are larger than the meter size) 4 ANSI-150 RF flanges 5 ANSI-300 RF flanges 6 PN16 DIN flanges 7 JIS 10kg/cm2 flanges 9 Customer nominated Cable Entries 0 3~6mm cable gland (with B2/B3 options) (OM004/008 & high pressure meters only) 1 M20 x 1.5mm 2 NPT Integral Options 00 Nil No Options RS Reed switch only Suit intrinsically safe installations E1 Explosion proof ~ Exd IIB T4/T6 (Aluminium & stainless meters) IECEX & ATEX approved E2 Explosion proof ~ Exd I/IIB T4/T6 (stainless meters only), mines approved IECEX & ATEX mines approved QP Quadrature pulse ( 2 NPN Phased outputs) Not available with high pressure models Q1 Exd with Quadrature pulse IECEX & ATEX approved HR High resolution hall effect output (Hall Effect only) (OM004 & OM006 only) OM004: 11200ppL,OM006: 4200ppL H1 Exd with HR Hi-res. Hall Option.(OM004 and OM006 only) IECEX & ATEX approved PF Pulsating flow option (hall effect output only) For injected combustion engines P1 Exd with PF pulsating flow option IECEX & ATEX approved B2 BT11 dual totaliser with pulse output With scaleable pulse output B3 Intrinsically safe BT11 ( I.S. ) IECEX & ATEX approved R0 RT12 Flow Rate Totaliser with all outputs in Aluminium Enclosure With scaleable pulse output R2 FRT12 Flow Rate Totaliser with all outputs With scaleable pulse output R3 Intrinsically safe FRT12 ( I.S. ) IECEX & ATEX approved E0 EB10 batch controller Two stage DC batcher and totaliser F1 Loop powered 4 ~ 20mA analog output (80C max) SB Specific build requirement
Page 17
B OPTION GRN Housing FRT12/FEB Alloy Housing FRT12 FBT Cover Aluminium Pulse (Kg) Stainless Steel Pulse (Kg) OM004 122 125 113 92 0.8 1.5
C All 124 96 94 72 -
OM015~OM050
A Modular Fitting A.N.S.I. 150 DIN 16 JIS 10K B.S.P. N.P.T. OM015-A 110 110 B Configuration GRN Housing FRT12/FEB FBT Register Alloy Housing FRT12 Cover Mechanical Register OM015-A 154 145 157 106 178
A OM025-A 198 198 198 137 137 B OM025-A 168 160 171 120 188
A OM025-S 237 237 237 176 176 B OM025-S 165 157 168 117 214
A OM040-A 252 252 252 188 188 B OM040-A 203 195 206 155 227
A OM040-S 252 252 252 188 188 B OM040-S 194 186 197 146 222
A OM050-E 277 277 277 212 212 B OM050-E 268 260 271 220 286
OM050-A OM050-S 277 277 277 212 212 B OM050-A 218 210 221 170 237 277 277 277 212 212 B OM050-S 218 210 221 170 237
OM040 7.6 5 15 12
OM050-E 11 10 -
Page 18
A Modular Fitting A.N.S.I 150 DIN 16 JIS 10K B.S.P N.P.T OM080-A 354 354 354 266 266
OM080-E OM100-A 382 382 382 294 294 388 388 388 294 294
B Configuration GRN Housing FRT12/FEB FBT Register Alloy Housing FRT12 Cover Mech. Register OM080-A 260 252 264 213 270
Weight (kg) Aluminium Mechanical Aluminium Pulse S/Steel Mechanical S/Steel Pulse
OM080 15 14 32 30
OM080-E 22 20 -
OM100-A 24 23 -
OM100-E 28 26 -
Page 19
Specifications
Capacity group Model prefix: Nominal size (inches) *Flow Range(LPH) L/min **Accuracy @ 3cp Repeatability Temperature range 41- OM004 4mm ( /8)
3
SMALL CAPACITY 41- OM006 6mm () (2 ~ 100) 41- OM008 10mm ( /8)
3
MEDIUM CAPACITY 41- OM015 13mm () 1 ~ 40 41- OM025 25mm (1) 10 ~ 150 41- OM040 40mm (1) 15 ~ 250 41- OM050 50mm (2) 30 ~ 450 41- OM050E 50mm (2) 35 ~ 580 41- OM080 80mm (3) 35 ~ 750
LARGE CAPACITY 41- OM080E 80mm (3) 50 ~ 1000 41- OM100 100mm (4) 75 ~ 1500 41- OM100E 100mm (4) 150 ~ 2500
(0.5 ~ 36)
(15 ~ 550)
1% of reading
0.5% of reading
0.5% of reading
Typically 0.03% of reading (accuracy is 0.2% of reading with optional RT12 with non-linearity correction) -40 ~ +120C ( -4F ~ +250F ) refer JSG for lower temperature (150C max. using Hall effect) Max 80C Mechanical Meter Bar (psi) 15 (220) 34 (500) 100 (1450) 400 (5880) 100 (1450) 400 (5880) 100 (1450) 400 (5880) 68 (990) 100 (1450) 400 (5880) P-68 (990) M-40 (580) P-68 (990) M-40 (580) 138 (2000) 68 (990) 100 (1450) 400 (5880) Pulses / L 2800 (10600) 2800 (10600) 2800 (10600) 11200 (42392) 1050 (3975) 1050 (3975) 1050 (3975) 4200 (15897) 355 (1345) 710 (2690) 708 (2680) 84 (318) 168 (636) 168 (636) 27 (102) 107 (405) 54 (204) 30 (440) 50 (725) 400 (5880) P-38 (550) M-20 (285) 50 (725) 300 (4200) 12 (180) 30 (440) 20 (285) 20 (285) 12 (180) 12 (180) 10 (150) 10 (150)
Intermediate press. SS meter High pressure models Output pulse resolution Reed switch Hall effect Quadrature Hall option High resolution Hall effect Reed switch output Hall effect output (NPN) Optional outputs Physical Protection class Overall dimensions Recommended filtration
(pulses / US gal) - nominal 14 (53) 56 (212) 28 (106) 6.5 (24.7) 26 (99) 13 (49) 4.8 (18) 19 (72) 9.3 (36) 2.65 (10) 10.65 (40.5) 5.33 (20) 1.5 (5.68) 6.0 (23.7) 3.0 (11.36) 1.1 (4.15) 4.4 (16.6) 2.2 (8.3) 0.56 (2.1) 2.24 (8.5) 1.12 (4.24)
30Vdc x 200mA max. (maximum thermal shock 10C (50F) / minute 3 wire open collector, 5-24Vdc max., 20mA max. 4~20mA, scaled pulse, quadrature pulse, flow alarms or two stage batch control
IP66/67 (NEMA4X), optional Exd 1 / IIB T4/T6, integral ancillaries can be supplied I.S. (intrinsically safe) Refer pages 18~19 75 microns (200 mesh) 150 microns (100 mesh) 350 microns (40 mesh)
* Maximum flow rate is to be reduced as viscosity increases, see flow de-rating guide. Max. Allowable pressure drop is 100Kpa. (15psi) ** Accuracy 1% of reading with M series and V series 0.5% of reading on mechanical register
Flange mount : Optional For specific flow meters and part numbers refer to your JSG representative
Page 20
Installation Points
PD Meters do not work well with silty or dirty fluids (Use Strainers before meter) Straight Pipe not necessary before and after the meter Teflon Tape can cause rotor stoppages, use loctite thread sealant or similar High Velocity flows can cause rotor destruction (Slowly ramp up flow on start up) Avoid Water Hammer caused by closing valves quickly in batch applications Flush Pipe Lines prior to meter installation
Is the minimum and maximum flow rate? (continuous or Intermittent) Are the minimum and maximum pressures? Is the viscosity of the fluid? Is the fluid being measured (Acid, Resin etc)? Is the maximum and minimum temperature? Is the preferred connection type (BSPP, NPT etc)? Type of display do you require (Mechanical meter, Pulse meter etc)? Type of output is required (4 digit Mechanical, Pulse output with LCD)? Type of strainer is required (Particles in the fluid)?
Please refer to the Flow Meter Selection Form on page 27. This form is designed to assist in the selecting the appropriate model required for the application. Use this form in conjunction with pages 14 to 17. For further assistance please contact a JSG representative
Page 21
0.3~10 m/sec (1~33 feet/sec) Typically 1.5% with well established flow profile -40C~+100C (-40F~+212F) 150C max 80 bar (1200 psig) 316SS body & rotor shaft, PVDF rotor (option peak rotor)
Features
IP68 (NEMA6) submersible 316SS construction Low cost of ownership, wide flow range Rugged and compact design Intrinsically safe hazardous area versions Integral or remote pre-amplifiers and flow instruments DP525 version suitable for hot tap installation BI-Directional Flow Measurement
*Maximum thermal shock 10C (50F) /min. applies to the reed switch
Page 22
1 2
with scaleable pulse output IECEx & ATEX mines approved scaled pulse, alarms & 4~20mA IECEx & ATEX mines approved scaled pulse, alarms & 4~20mA dc powered 2 stage batch controller Requires electrical connection
M o d e l N o. E x a m p l e 2 1 41 - DP490 - S
R2
Page 23
General Specifications
Model Prefix Nominal sizes Accuracy @ 1cp Temperature range Maximum pressure 316 stainless steel High pressure SS Peek Protection Class 10 bar (147 psi) N/A 10 bar (147 psi) 250 bar (3680 psi) 10cst. max 400 bar (5580 psi), 68cst max N/A TM - Turbopulse mini 6mm ( BSPF) 1~2% FSD or 0.75% o.r 5~125C (40~250F) TP - Turbopulse 12~500mm (~20) 0.5% or (10:1 turndown) -40~+250C (-40~+460F)
Electrical (see also optional outputs - Turbopulse pick-off types) Standard output Hall effect sensor Pick off Coil
Flanged Process connections Explosion proof Integral and remote preamplifier LCD totaliser-batch totaliser Flow rate totalisers Scaled pulse 4~20mA and flow alarm outputs Electronic batch controllers and pulse processing modules
size
Features
3 4
High accuracy and repeatability Low cost of ownership, wide flow range Rugged and compact design Certified Exd and I.S hazardous area versions Quadrature pulse output option Integral or remote pre-amplifiers and flow instruments 0.15% custody transfer models available
6 8 10 12 16 20
Page 24
Junction Box, EXD Preamplifier EXD F/I Converter Option MS Connector FRT12/EB Register
316 stainless steel - 250 bar (3500 psi) max. High pressure SS, 400 bar (5580 psi) - 68cst max. (available up to TP040) Process Connections BSPP male threaded NPT male threaded *Tri-clamp ferrules (316SS) ANSI-150 RF Flanges ANSI-300 RF Flanges PN10 DIN flanges PN16 DIN flanges PN25 DIN flanges Customer nominated connections *Tri-clamp ferrules are 1/2" larger than the meter size Process Connection Material threaded stainless steel T C carbon steel flanges ( TP080+ ) 316 stainless steel flanged process connections S No. of Pick-offs one 1 two x 90 degree electricity offset ( TP100+ ) 2 Pick-off Style 1 2 MS (militiary style) connector FL (flying leads for integral mounting) Pick-off Type 1 standard coil (120C [250F] max.) 2 hermetically sealed or high temp coil 3 intrinsically safe coil - ATEX Approved 4 preamplified (MS connector only) 1 2 +/-0.5% (standard) +/-0.15% (custody transfer TP100+) Nil Junction box - ATEX Approved Exd preamplifier - ATEX Approved BT11 dual totaliser I.S. intrinsically safe BT11 RT12 rate totaliser I.S. intrinsically safe RT12 FRT12 Flow rate totaliser in Aluminium Enclosure EB10 dc batch controller Specific build requirement
1 2 3 4 5 6 7 8 9
FLANGED METERS AVAILABLE WITH ANSI OR DIN FLANGES. SEE APPLICABLE STANDARD FOR FLANGE DIMENSIONS
Flanged Meters
Model No. 41 - TP010 41 - TP012 41 - TP015 41 - TP020 41 - TP025 41 - TP040 41 - TP050 41 - TP080 41 - TP100 41 - TP150 41 - TP200 41 - TP250 41 - TP300 41 - TP400 41 - TP500 A 127mm (5.0) 127mm (5.0) 127mm (5.0) 140mm (5.0) 152mm (6.0) 178mm (7.0) 197mm (7.8) 254mm (10.0) 356mm (14.0) 368mm (14.5) 457mm (18.0) 457mm (18.0) 457mm (18.0) 610mm (24.0) 610mm (24.0) Option fitted FRT12/EB Register (R2) FRT12 Register (RO) BT Register EX Junction Box MS Connector MS Connector with Pre-Amo H 210mm 185mm 190mm 150mm 118mm 138mm
41 - TP025 S
OO JB PA B2 with scaleable pulse output B3 IECEx & ATEX approved R2 scaled pulse, alarms & 4~20mA R3 IECEx & ATEX approved R0 scaled pulse, alarms & 4~20mA dc powered 2 stage batch controller E0 SB M o d e l N o. E x a m p l e 1 T 1 -
R2
Threaded Meters
Model No. 41 - TP010 41 - TP012 41 - TP015 41 - TP020 41 - TP025 41 - TP040 41 - TP050 B 64mm (2.5) 64mm (2.5) 64mm (2.5) 83mm (3.3) 89mm (3.5) 115mm (4.5) 133mm (5.5) C BSP or NPT BSP or NPT BSP or NPT BSP or NPT 1 BSP or NPT 1 BSP or NPT 2 BSP or NPT
Page 25
The next picture shows what will happen to a rotor when the fluid that is being pumped through does not have a filter. The particles run through the meter and cause damage to the rotors. This will eventually prevent the rotors from operating smoothly causing them to seize. This can result in expensive downtime that could have been avoided by an in expensive strainer. Solution: For dirty/unclean fluids always use a filter or strainer
This is a great example of a turbine flow meter that has been installed with absolutely no flow-conditioning. In order for the meter to provide accurate results the flow in the pipe must be laminar and therefore a measured straight run (x10 pipe diameter) must installed before and after the meter. When installing turbine flow meters and paddlewheel (insertion meters), flow conditioning is crucial to obtain a steady smooth laminar flow for accurate readings. Solution: Calculate and install meter with appropriate straight run either side of the meter (Turbo pulse and paddle wheel meters only)
To the right you will see a large capacity meter being installed on its back. The bearings installed have a small amount either side of the rotor to provide a very small thrust gap. This is crucial for smooth operation. When laying on its back the weight of the rotors close this gap and eventually have the rotors spinning against the body of the meter. The rotor will eventually wear away against the body and seize as it will no longer spin. Solution: Always position the meter facing perpendicular to the ground
If at any time you are uncertain of how to install a meter please contact your JSG representative.
Page 26
1. What is the minimum and maximum flow rate? (Check fluid compatibility)
Body Material
4. What is the fluid being measured by the flow meter? (Fuel, Resin etc - Check compatibility)
O-Ring Material
5. What is the maximum & minimum temperatures? (Operating in low or high temps)
Temperature Limits
6. What is the pipe size & process connections? (eg. BSP, NPT, ANSI etc)
Process Connections
7. What type cable entry are you after? Are you after a register to be mounted on the meter?
Cable Entries
8. Do you require a direct mount, remote display or batching option? Signal output?
Integral Options
9. Does the fluid have particles? If Yes what is the size of the particles (mesh size)?
Strainer Type
Page 27
Sydney Unit 1, 21 Amour St Revesby NSW 2212 PO Box 333 Milperra NSW 2214 Ph: (02) 9914 8720 Email: jsgindustrial@jsg.com.au
Melbourne 3/62-68 Garden Drive Tullamarine VIC 3043 Ph: (03) 8809 1300 Email: jsgvic@jsg.com.au
Perth 2 Holder Way Malaga WA 6090 Ph: (08) 6240 5800 Email: jsgwa@jsg.com.au
Brisbane Unit 1/20 Lancashire St Acacia Ridge QLD 4110 Ph: (07) 3273 3433 Email: jsgqld@jsg.com.au
Adelaide Suite 7, 8 Greenhill Rd Wayville SA 5034 Ph: (08) 8372 9503 Email: jsgsa@jsg.com.au
Cessnock Level 1/426 Macdonalds Rd Pokolbin NSW 2325 Ph: 0447 277 755 Email: jsghv@jsg.com.au
Townsville Level 1, 1/5 Woolcock St Hyde Park Townsville QLD 4810 Ph: 0419 021 892 Email: jsgfnq@jsg.com.au
Mackay C03 216 Harbour Rd Mackay QLD 4740 Ph: (07) 4944 0588 Email: techcq@jsg.com.au
Indonesia PT JSG International Jl. Ciputat Raya, No. 1C RT.003/RW. 010 Kebayoran Lama Selatan, Kebayoran Lama, Jakarta Selatan 12240 Ph: (62-21) 7239 511 Email: sales@ptjsg.co.id
Every effort has been made to ensure all information and photographs contained in this publication were correct and accurate at time of printing, however no warranty is given in respect of this publication and JSG Industrial Systems Pty Ltd (JSG) shall not be liable for any error therein. Technical information, specifications and products shown may be subject to change without prior notice. Pictures shown are for illustration purposes only. WARNING: For sale and proper use consult instructions, the supplier or JSG. Contact your nearest JSG Distributor for latest information. 2013 JSG Industrial Systems Pty Ltd., All rights reserved.