Copiar en WOR Detailed Report, Cross Section, Rating Curve (para una familia de curvas de al menos 5 pendientes diferentes).
Input Data
Roughness Coefficient Channel Slope Bottom Width Discharge 0.015 0.20000 3.00 15.00 % m m/s
Results
Normal Depth Flow Area Wetted Perimeter Hydraulic Radius Top Width Critical Depth Critical Slope Velocity Velocity Head Specific Energy Froude Number Flow Type Subcritical 1.89 5.67 6.78 0.84 3.00 1.37 0.00471 2.65 0.36 2.25 0.61 m m m m m m m/m m/s m m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:10:29 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
2. Disear un canal triangular con paredes con una inclinacin de 70 con la horizontal, con una pendiente del 3 por mil de csped, para un caudal de 4 m/s. Copiar en WORD Detailed Report, Cross Section, Rating Curve (para una familia de curvas de al menos 5 pendientes diferentes).
Input Data
Roughness Coefficient Channel Slope Left Side Slope Right Side Slope Discharge 0.024 0.30000 0.36 0.36 4.00 % m/m (H:V) m/m (H:V) m/s
Results
Normal Depth Flow Area Wetted Perimeter Hydraulic Radius Top Width Critical Depth Critical Slope Velocity Velocity Head Specific Energy Froude Number Flow Type Subcritical 2.82 2.87 6.00 0.48 2.03 1.91 0.02431 1.40 0.10 2.92 0.38 m m m m m m m/m m/s m m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:23:42 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
3. Disear un canal trapezoidal de base 2 metros, con una pendiente del 2 por mil de tierra, con paredes laterales con una inclinacin de 55 con la horizontal, para un caudal de 7.5 m/s. Copiar en WORD Detailed Report, Cross Section, Rating Curve (para una familia de curvas de al menos 4 pendientes diferentes).
Input Data
Roughness Coefficient Channel Slope Left Side Slope Right Side Slope Bottom Width Discharge 0.030 0.20000 0.70 0.70 2.00 7.50 % m/m (H:V) m/m (H:V) m m/s
Results
Normal Depth Flow Area Wetted Perimeter Hydraulic Radius Top Width Critical Depth Critical Slope Velocity Velocity Head Specific Energy Froude Number Flow Type Subcritical 1.71 5.46 6.17 0.88 4.39 1.00 0.01361 1.37 0.10 1.80 0.39 m m m m m m m/m m/s m m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:28:32 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 16:57:51 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
4. Disear una tubera circular de 800mm de dimetro de PVC, con una pendiente del 1.5%, para un caudal de 700 L/s. Copiar en WORD Detailed Report, Cross Section, Rating Curve (para una familia de curvas de al menos 4 pendientes diferentes).
Input Data
Roughness Coefficient Channel Slope Diameter Discharge 0.010 1.50000 800.00 700.00 % mm L/s
Results
Normal Depth Flow Area Wetted Perimeter Hydraulic Radius Top Width Critical Depth Percent Full Critical Slope Velocity Velocity Head Specific Energy Froude Number Maximum Discharge Discharge Full Slope Full Flow Type SuperCritical 0.32 0.19 1.09 0.17 0.78 0.51 39.7 0.00308 3.77 0.72 1.04 2.47 2.26 2.11 0.00166 m/s m/s m/m m m m m m m % m/m m/s m m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:32:06 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 16:58:34 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
Input Data
Channel Slope Discharge Section Definitions Station (m) 0+00 0+00 0+01 0+01 0+02 0+02 0+03 0+03 Roughness Segment Definitions Start Station (0+00, 2.40) Ending Station Roughness Coefficient 0.015 Elevation (m) 2.40 1.20 1.20 0.00 0.00 1.20 1.20 2.40 0.10000 4800.00 % L/s
(0+03, 2.40)
Options
Current Roughness Weighted Open Channel Weighting Method Closed Channel Weighting Method Pavlovskii's Method Pavlovskii's Method Pavlovskii's Method
Results
Normal Depth Elevation Range Flow Area Wetted Perimeter Hydraulic Radius
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:44:51 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 2
m m m m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 16:59:13 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
Segundo canal.-
Input Data
Channel Slope Discharge Section Definitions 0.10000 4.80 % m/s
Options
Current Roughness Weighted Open Channel Weighting Method Closed Channel Weighting Method Pavlovskii's Method Pavlovskii's Method Pavlovskii's Method
Results
Normal Depth Elevation Range Flow Area Wetted Perimeter Hydraulic Radius Top Width Normal Depth 0.00 to 1.70 m 3.40 6.20 0.55 2.00 2.10 m m m m m 2.10 m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 0:55:10 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 17:02:19 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
6. Disear los canales, con una pendiente de 2 por mil, para un caudal de 6500 l/s (a=c=1.00m; d=D=1.20m; m=1.0m; n=0.80m; e=1.50m). Copiar en WORD Detailed Report, Cross Section, Rating Curve (para una familia de curvas de al menos 4 pendientes diferentes). Primer canal.-
Input Data
Channel Slope Discharge Section Definitions Station (m) 0+00 0+00 0+01 0+02 0+03 0+03 Roughness Segment Definitions Start Station (0+00, 1.80) Ending Station Roughness Coefficient 0.015 Elevation (m) 1.80 1.00 1.00 0.00 0.00 1.80 0.20000 6.50 % m/s
(0+03, 1.80)
Options
Current Roughness Weighted Open Channel Weighting Method Closed Channel Weighting Method Pavlovskii's Method Pavlovskii's Method Pavlovskii's Method
Results
Normal Depth Elevation Range Flow Area Wetted Perimeter Hydraulic Radius Top Width Normal Depth 0.00 to 1.80 m 3.16 5.53 0.57 3.20 1.46 m m m m m 1.46 m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 1:17:49 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 17:03:02 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
Segundo canal.-
Input Data
Channel Slope Discharge Section Definitions 0.20000 6.50 % m/s
Station (m) 0+00 0+00 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+01 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02
Elevation (m) 2.10 0.60 0.60 0.55 0.50 0.44 0.39 0.35 0.30 0.26 0.21 0.18 0.14 0.11 0.08 0.06 0.04 0.02 0.01 0.00 0.00 0.00 0.01 0.02 0.04 0.06 0.08
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 16:30:02 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
1 of
Station (m) 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+02 0+03 0+03
Elevation (m) 0.11 0.14 0.18 0.21 0.26 0.30 0.35 0.39 0.44 0.50 0.55 0.60 0.60 2.10
Options
Current Roughness Weighted Open Channel Weighting Method Closed Channel Weighting Method Pavlovskii's Method Pavlovskii's Method Pavlovskii's Method
Results
Normal Depth Elevation Range Flow Area Wetted Perimeter 0.00 to 2.10 m 3.13 5.40 m m 1.46 m
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 17:04:17 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
Page
2 of
Bentley Systems, Inc. Haestad Methods Solution Center Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 15/09/2013 17:04:17 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666