Professional Documents
Culture Documents
Programmable Transmitter
Programmable Transmitter
5116A
PROGRAMMABLE TRANSMITTER
Application:
Applications
Input signals:
Current
Potentiometer
2-wire
transmitter
53
TC
54
V>
2.5V
+
+
Voltage
V<=
2.5V
+
52
44
43
42
51
41
Output signals:
Relays
Technical characteristics:
Within a few seconds the user can program
PR5116A to suit the specific application.
24
14
2-wire transmitter
output
23
13
mA
12
mA
22
mA
V
21
11
Analogue, 0/4...20 mA and voltage
Supply:
33
21.6...253 VAC
or
19.2...300 VDC
32
31
Order: 5116A
*NB! Please remember to order CJC connector
type 5910 in connection with TC input with
internal CJC.
Electrical specifications:
Specifications range:
-20C to +60C
Common specifications:
Supply voltage, universal................... 21.6...253 VAC, 50...60 Hz
or 19.2...300 VDC
Max. consumption.............................. 3 W
Fuse.................................................... 400 mA SB / 250 VAC
Isolation voltage, test / operation....... 3.75 kVAC / 250 VAC
Communications interface................. Loop Link
Signal / noise ratio.............................. Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%), programmable:
Temperature / mV input............... 400 ms to 60 s
mA / V / mV input.......................... 250 ms to 60 s
Signal dynamics, input....................... 22 bit
Signal dynamics, output..................... 16 bit
Calibration temperature...................... 20...28C
Accuracy, the greater of the general and basic values:
General values
Absolute
accuracy
Temperature
coefficientc
0.05% of span
0.01% of span / C
Input type
All
Basic values
Basic
accuracy
Temperature
coefficient
mA
4 A
0.4 A / C
Volt
10 V
1 V / C
RTD
0.2C
0.01C / C
Lin.R
Input type
0.1
10 m / C
TC type:
E, J, K, L, N, T, U
1C
0.05C / C
TC type: B, R, S,
W3, W5, LR
2C
0.2C / C
Auxiliary supplies:
Reference voltage..............................
2-wire supply, pin 54...52...................
Max. wire size.....................................
Screw terminal torque........................
Relative humidity................................
Dimensions (HxWxD)..........................
Protection degree...............................
Weight................................................
Electrical specifications, INPUT:
Max. offset..........................................
TC input:
Type
Min.
value
Max.
value
B
E
J
K
L
N
R
S
T
U
W3
W5
LR
+400C
-100C
-100C
-180C
-100C
-180C
-50C
-50C
-200C
-200C
0C
0C
-200C
+1820C
+1000C
+1200C
+1372C
+900C
+1300C
+1760C
+1760C
+400C
+600C
+2300C
+2300C
+800C
Min.
span
200C
50C
50C
50C
50C
100C
200C
200C
50C
75C
200C
200C
50C
Standard
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
ASTM E988-90
ASTM E988-90
GOST 3044-84
mV input:
Measurement range........................... -2500...+2500 mV
Min. measurement range (span)......... 5 mV
Input resistance.................................. > 5 M
RTD and linear resistance input:
Type
Min. value
Pt100
Ni100
Lin. R
-200C
-60C
0
Max. value
+850C
+250C
5000
Min. span
Standard
25C
25C
30
IEC 60751
DIN 43760
-----
5116AY103-UK (1003)