8115165rrev1 PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

TEST REPORT

TufShield a division of Intrigue Services 5863 Leslie St., Suite 431 Toronto, ON M2H 1J8 CANADA DTL REPORT NO REPORT DATE RECEIVE DATE CUSTOMER REF 8115165R1 March 20, 2009 January 22, 2009 PO1008

SAMPLE DESCRIPTION TufShield submitted two (2) types of wood samples (coated) identified as: - Teak - Mahogany DTL provided adhesion tape (3M 898) to TufShield to place on the samples prior to coating and left half of the tape exposed from which to pull from. WORK REQUESTED/TEST SPECIFICATIONS Per Clients Email dated 9/16/08 Salt Spray Testing per ASTM B117-07 - 500hrs Gloss Testing - Pre and Post (for each exposure) Salt Spray QUV Ozone Thermoshock QUV Testing per ASTM G154-06 - 500hrs Ozone Testing per ASTM D1171-99 - 70hrs Thermoshock Testing - 80 cycles

Page 1 of 7
Detroit Testing Laboratory, Inc. letters, reports and data are for the exclusive use of our customers to whom they are addressed and shall not be reproduced, except in full, without the written approval of the laboratory. Our letters and reports apply only to those samples tested, and are not necessarily indicative of the qualities of apparent identical or similar products. Samples not destroyed in testing are retained for a maximum of thirty (30) days. The use of the name Detroit Testing Laboratory, Inc. or its seal or insignia, are not permitted to be used by the customer on their communications, brochures, advertising, reports or other forms of media, without prior written approval. Reported test parameters are generally specified as set points of testing equipment. All documentation and data utilized in the generation of this report are available upon request. QCF1090 12/4/06

TufShield

DTL Report Number: 8115165R1


March 20, 2009

WORK REQUESTED/TEST SPECIFICATIONS CONTINUED Peel Testing - Test Speed: 50 mm/min - Peel As Received and after each exposure Salt Spray QUV Ozone Thermoshock

SAMPLE CONDITIONING Prior to testing, the samples were conditioned at 232C and 505% relative humidity, as applicable. CORRESPONDENCES DTL Photo CD labeled DTL Report 8115165 Test Photographs TEST RESULTS SALT SPRAY TESTING PER ASTM B117-07 Exposure Results Eight (8) specimens (4 Teak and 4 Mahogany) for 500 hours No visual evidence of change after exposure. Refer to photo CD for test photographs Requirements Conclusion None Specified To be determined by TufShield

Page 2 of 7
QCF1090 12/4/06

TufShield

DTL Report Number: 8115165R1


March 20, 2009

GLOSS TESTING Results Gloss Readings at 60 Pre Exposure Post Exposure Sample Exposure (avg.) (avg.) Salt Spray 92.4 91.3 QUV 91.4 91.3 Mahogany Ozone 91.5 91.7 Thermoshock 92.6 93.3 Salt Spray 91.4 90.5 QUV 92.1 93.3 Teak Ozone 91.9 89.4 Thermoshock 92.7 93.3 Requirements Conclusion None Specified To be determined by TufShield Change (%) -1.0 -0.1 0.3 0.7 -1.0 1.4 -2.8 0.6 Retention (%) 99.0 99.9 100.3 100.7 99.0 101.4 97.2 100.6

QUV TESTING PER ASTM G154-06 Exposure Exposure Cycle Results Twelve (12) specimens (6 Teak and 6 Mahogany) for 500 hours. 8 hours of U.V.A. at 70C Followed by 4hrs of condensation at 50C All (12) specimens showed a moderate amount of darkening. Refer to photo CD for test photographs Requirements Conclusion None Specified To be determined by TufShield

Page 3 of 7
QCF1090 12/4/06

TufShield

DTL Report Number: 8115165R1


March 20, 2009

OZONE TESTING PER ASTM D1171-99 Exposure Results Ten (10) specimens (5 Teak and 5 Mahogany) for 70hrs at 50pphm ozone/40C. All (10) specimens showed no visual evidence of change after exposure. Refer to photo CD for test photographs Test Note: Requirements Conclusion Deviation of Procedure: Specimens were not elongated due to their rigid nature. None Specified To be determined by TufShield

THERMOSHOCK TESTING Exposure Twelve (12) specimens (6 Teak and 6 Mahogany) for 80 cycles, one (1) cycle consisting of the following exposures 1hr at -40C 1hr at 110C Ramp time of <60 seconds Repeat for a total of 80 cycles All (12) specimens showed a moderate amount of darkening after exposure. Refer to photo CD for test photographs Requirements Conclusion None Specified To be determined by TufShield

Results

Page 4 of 7
QCF1090 12/4/06

TufShield

DTL Report Number: 8115165R1


March 20, 2009

PEEL TESTING Procedure TufShield prepared Specimens were peel tested to determine the effects of the conditioning on the coating and tape as applied to the wooden specimens. See Attachment A (10 pages) Sample Exposure Peak Peel Strength (lbf/in) (N/cm) 3.71 6.50 3.35 5.86 5.59 9.79 3.61 6.31 5.67 9.93 3.22 5.63 3.46 6.06 2.81 4.93 3.13 5.48 2.50 4.38

Results

As Received Salt Spray Mahogany QUV Ozone Thermoshock As Received Salt Spray Teak QUV Ozone Thermoshock Requirements Conclusion TEST EQUIPMENT None Specified

To be determined by TufShield

Detroit Testing Laboratory, Inc.s calibration system meets the requirements of ISO 17025:2005.
Mitutoyo Corp, Digital Caliper, M/N CD-6, ID: 09350, calibrated to: 7/09 Instron Corp; Load Cell (20 lbs), M/N 2518-807, ID: 07669, calibrated to: 7/09 Instron Corp; Tensile/Compression Machine, M/N 4201, ID: 07133, calibrated to: 7/09 Ozone Research & Equipment Corp.; Ozone Chamber, M/N 03DM-100, ID: EC069, Monitor ID: 07200, calibrated to: 10/09 Q-Panel Co.;QUV Cabinet Accelerated Weathering,M/N QUV, ID: EC078,calibrated to: 4/09 Gardner; Portable Glossmeter, M/N Micro-Tri-Gloss 4525, ID: 08628, calibrated to: 11/11 Environmental Test Chamber; DTL ID: EC118; calibrated to: 3/09 Singleton Salt Spray Cabinet (A-4); M/N 22, ID: EC122, calibrated to: 6/09

Page 5 of 7
QCF1090 12/4/06

TufShield

DTL Report Number: 8115165R1


March 20, 2009

Attachment A
(10 pages to follow)

Peel Testing - Data Sheets

Attachment A - Page 7 of 7
QCF1090 12/4/06

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Teak Conditioning: Post Thermal Shock Cycling Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
14 12 10

Load (N)

8 6 4 2 0 -2 0 10 20 30 40 50

Specimen # 1 2 3

Extension (mm)

Specimen ID 1 2 3 Average 10 11 12

Peak Load per Width (lbf/in) 1.99 3.26 2.26 2.50

Peak Load per Width (N/cm) 3.48 5.70 3.96 4.38

Tufshield 8115165 - Peel - Thermal Shock - Teak-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Mahogany Conditioning: Post Thermal Shock Cycling Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
30

20

Load (N)

Specimen # 10 1 2 3

-10 0 10 20 30 40 50

Extension (mm)

Specimen ID 1 2 3 Average 10 11 12

Peak Load per Width (lbf/in) 5.19 4.82 7.01 5.67

Peak Load per Width (N/cm) 9.09 8.44 12.27 9.93

Tufshield 8115165 - Peel - Thermal Shock - Mahogany-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Teak Conditioning: Post Salt Spray Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
20

15

Load (N)

10

Specimen # 1 2 3

-5 0 10 20 30 40 50

Extension (mm)

Specimen ID 1 2 3 Average 1 2 3

Peak Load per Width (lbf/in) 4.24 3.62 2.53 3.46

Peak Load per Width (N/cm) 7.42 6.34 4.43 6.06

Tufshield 8115165 - Peel - Salt Spray - Teak-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Mahogany Conditioning: Post Salt Spray Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
20

15

Load (N)

10

Specimen # 1 2 3

-5 0 10 20 30 40 50

Extension (mm)

Specimen ID 1 2 3 Average 1 2 3

Peak Load per Width (lbf/in) 3.09 2.84 4.11 3.35

Peak Load per Width (N/cm) 5.42 4.97 7.20 5.86

Tufshield 8115165 - Peel - Salt Spray - Mahogany-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Teak Conditioning: Post QUV Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
14 12 10

Load (N)

8 6 4 2 0 0 10 20 30 40 50

Specimen # 1 2 3

Extension (mm)

Specimen ID 1 2 3 Average 4 5 6

Peak Load per Width (lbf/in) 2.67 2.57 3.20 2.81

Peak Load per Width (N/cm) 4.68 4.50 5.60 4.93

Tufshield 8115165 - Peel - QUV - Teak-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Mahogany Conditioning: Post QUV Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
30

20

Load (N)

Specimen # 10 1 2 3

-10 0 10 20 30 40 50

Extension (mm)

Specimen ID 1 2 3 Average 4 5 6

Peak Load per Width (lbf/in) 4.81 6.99 4.97 5.59

Peak Load per Width (N/cm) 8.42 12.24 8.70 9.79

Tufshield 8115165 - Peel - QUV - Mahogany-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Teak Conditioning: Post Ozone Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
16 14 12

Load (N)

10 8 6 4 2 0 -2 -10 0 10 20 30 40 50 Specimen # 1 2 3

Extension (mm)

Specimen ID 1 2 3 Average 7 8 9

Peak Load per Width (lbf/in) 3.00 3.39 3.00 3.13

Peak Load per Width (N/cm) 5.25 5.93 5.25 5.48

Tufshield 8115165 - Peel - Ozone - Teak-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Mahogany Conditioning: Post Ozone Exposure

Operator: Don LeHue Conditions: 22F, 48%RH

Specimen 1 to 3
20

15

Load (N)

10

Specimen # 1 2 3

-5 0 10 20 30 40 50

Extension (mm)

Specimen ID 1 2 3 Average 7 8 9

Peak Load per Width (lbf/in) 4.59 3.61 2.62 3.61

Peak Load per Width (N/cm) 8.04 6.32 4.58 6.31

Tufshield 8115165 - Peel - Ozone - Mahogany-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Teak Conditioning: None - Tested as Received

Operator: Don LeHue Conditions: 22F, 50%RH

Specimen 1 to 1
16 14 12

Load (N)

10 8 6 4 2 0 -2 0 10 20 30 40 50 Specimen # 1

Extension (mm)

1 Average

Peak Load per Width (lbf/in) 3.22 3.22

Peak Load per Width (N/cm) 5.63 5.63

Tufshield 8115165 - AR - Teak-a.is_ptf

Detroit Testing Laboratory

Thursday, March 19, 2009

180 Peel Strength Testing Job Number: 8115165 Customer: TufShield, Inc. Substrate ID: Mahogany Conditioning: None - Tested as Received

Operator: Don LeHue Conditions: 22F, 50%RH

Specimen 1 to 1
25

20

Load (N)

15 Specimen # 10 1

0 0 10 20 30 40 50

Extension (mm)

1 Average

Peak Load per Width (lbf/in) 3.71 3.71

Peak Load per Width (N/cm) 6.50 6.50

Tufshield 8115165 - AR - Mahogany-a.is_ptf