C264 Barres 225kv Exist
C264 Barres 225kv Exist
C264 Barres 225kv Exist
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
C264 L B 0 I 6 8 1 0 0 0 2 2 0 0 0 0 0 0 A 1 1 1 1 N 1 0 L
6 8 1 0 0
For CPU with 2 serial links: Factory Setted Legacy Ports N 3/4
Port N3: RS232 (non isolated) ; Port N4: RS232 (non isolated) Port N3: RS485(ECU201) ; Port N4: RS485(ECU201) Port N3: Optical(ECU200) ; Port N4: Optical(ECU200)
Manufacturing Process
Automatic affectation (as standard) of the I/O modules in the basic rack
Nominal wetting voltage for digital inputs (DIU200(-) or DIU211(+) or CCU200(-) or DSP210(-))
VA,nom: VA,nom: VA,nom: VA,nom: VA,nom: 24 V DC (- to earth) DIU200-A01 board or CCU200-A01 board or DSP210-A01 48/60 V DC (- to earth) - DIU200-A02 board or CCU200-A02 board or DSP210-A02 110/125 V DC (- to earth) - DIU200-A03 board or CCU200-A03 board or DSP210-A03 220 V DC (- to earth) : DIU200-A04 board or CCU200-A04 board or DSP210-A04 110-125 VDC (-to earth) - DIU200-A03 board or CCU200-A07 board (input setted if > 68% Vn)
Note: With rack 'L' & Wetting Voltage = 110/125 Vdc, 10 x DIU 210 boards maximum
Digital Input Module (16 DI), each with 16 digital inputs (DIU200A0x)
DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = = = = = = = = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Multi Tension-Peak-Current Digital Input Module (16 DI), each with 16 digital inputs DIU211
DIU200 & DIU211 cannot be used in the same rack
Digital Output Module (10 DO), each with 10 digital outputs (DOU200)
DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = 0 1 2 3 4 5 6 7 8
1-4
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
C264 L B 0 I 6 8 1 0 0 0 2 2 0 0 0 0 0 0 A 1 1 1 1 N 1 0 0
Mixed Module (8 DI + 4 DO), each with 8 digital inputs and 4 digital outputs (CCU20x)
CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = = = = = = = = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Note: Additional board count must not exceed 13 : CCU cannot be adjacent to TMU
DC 4 Analog Input Module (C or V transducer connection) each with 4 analogue inputs (AIU201)
AIU201 AIU201 AIU201 AIU201 AIU201 AIU201 AIU201 quantity quantity quantity quantity quantity quantity quantity = = = = = = = 0 1 2 3 4 5 6
Ethernet-based Switch Unit (SWU20x) 0R Redundant Unit (SWR20x) OR Dual Humming Unit (SWD20x)
Without SWU200 - With four 10/100BaseT Ethernet ports (RJ45) SWU202- With two 100BaseF MultiMode Ethernet ports (ST) and four 10/100BaseT Ethernet ports (RJ45) SWU204- With two 100BaseF MonoMode Ethernet ports (SC) and four 10/100BaseT Ethernet ports (RJ45) SWR202 or SWR212 -With two 100BaseF MultiMode Ethernet ports (ST) + four 10/100BaseT Ethernet ports (RJ45) SWR204 or SWR 214 -With two 100BaseF MonoMode Ethernet ports (SC) + four 10/100BaseT Ethernet ports (RJ45) SWD202 or SWD212 - With two 100BaseF MultiMode Ethernet ports (ST) + four 10/100BaseT Ethernet ports (RJ45)
OK
Ethernet-based SCADA Communication Protocol ( to upper levels SCADA, DCS, Master Station, ...)
IEC 60870-5-104
Legacy Serial SCADA Communication Protocol (to upper levels: SCADA, DCS, Master station, etc)
Up to two SCADA links in: IEC 60870-5-101, DNP3, Modbus
1 1 1 N 1 0
Legacy IED communication protocols (To lower levels: Relays, PLC, RTU, etc)
Up to 4 IEDs links in: DNP3, MODBUS, IEC 60870-5-103, IEC 60870-5-101
User Application
Disabled Enabled ISaGRAF run-time for Programmable Logic, Automation, etc.
Built in Application
Disabled Synchrocheck/Voltage Regulation/ Autorecloser enabled