Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Silence is

golden
Low Noise, Soil & Waste System
The Plastic Alternative to Cast Iron

Product and Technical Guide

Content
04: Flying the flag in the World 18: Fields of Application

05: Product Range 19: Handling & Storage

06: Quality Assurance and Approvals 20: Recommendations

07: Noise Insulating Properties 23: Jointing

08: Technical Data 25: Fixing Technique

09: Product List 27: Fire Protection Collar

18: Installation
Flying the flag in the World

04
Product Range
PhonEX®AS is a complete low Iron, PhonEX®AS is quick and
noise, soil and waste system easy to install, because of its
made of Astolan®. It is the socket connections.
plastic alternative to Cast Iron.
The pipes are manufactured in a PhonEX®AS is resistant to hot
range of nominal pipe sizes from water and fulfills the
56, 70, 90, 100, 125, 150 and requirements of DIN 1986,
200 mm in diameter. which means 95ºC short term
Complemented by a full range and 90ºC long term temperature The system is designed for drainage. Compared to Cast Iron
of Astolan® fittings, the system loading. PhonEX®AS can be used professional wastewater PhonEX®AS soil and waste
offers flexibility of an extensive for the drainage of wastewater installations in buildings. system provides the specifier,
choice, excellent quality and between pH 2 and pH 12. Moreover it can be used for the plumber and end-user with
reliability. Compared to Cast roof-, estate- and bridge many advantages:

05

Complete Easy installation greasy wastewater, eg from


low noise system quick and economic professional kitchens.
PhonEX®AS pipes and fittings PhonEX®AS is lightweight thus
are produced entirely in easy to handle. Installation is Absolutely
Astolan®, from 56 mm up quick and easy, due to the not selective
to 200 mm in diameter. proven socket connections PhonEX®AS can be fixed with
Of course with the same high and easy pipe cutting. any commercial pipe bracket
wall thickness and overall Time and cost savings. (with rubber insert). Expensive
high density. No improvisation fixing techniques are not
or system change. Sound Long lives necessary.
insulation without gaps. the sound insulation
PhonEX®AS is extremely DN 90 Optimal
Magic robust, resistant to corrosion, for wall mounting
®
formula of Astolan internally very smooth and Dimension DN 90 is our effective solutions to pipe
PhonEX®AS is made of free of incrustations. modern solution for wall system renewal and
Astolan®; a minerally Approved for underground mounting. It is easy to install renovation. In addition to our
reinforced polypropylene. installation. Optimum and prevents damage to floors. own research we work closely
Because of its high specific conditions for a long life. with plumbers and
weight and its special Specialist independent consultants to
molecular structure, Astolan® Hot and greasy? pipe products bring innovative plastic
is able to absorb airborne No problem! KE KELIT constantly strives for materials and installation
sound as well as structure PhonEX®AS has an optimal new and innovative techniques to the building
borne sound. performance with hot and techniques to provide cost industry.
Quality Assurance and Approvals
Rigorous testing and quality building inspection approval
control throughout the entire with the approval number
production process ensures Z.-42.1-228 of the German
that PhonEX®AS pipes and Institute for Building (DiBt).
fittings together build a highly This also allows PhonEX®AS to
reliable and extremely be used as main pipeline for
effective low noise system. underground installations.

They have the RAL – quality


mark of the German
Community of Plastic Pipes
(GKR), Bonn, and a general

06

Worldwide certificates and


approvals:

Denmark: ETA Denmark VA Turkey: Turkish Standards


2.14 DK 6858 Quality Appropriateness
Norway: Godkjenningsnmnda Certificate
vor Sanitärmateriell Nr. 61-090 Poland: Aprobata techniczna
Sweden: Boverket COBRTI INSTAL
DNR 83-4480/90 Nr AT-99-02-0670
Australia: Watermark
Nr.: MP52 Spec 005
Germany: DiBt, Z.-42.1-228
Noise Insulating Properties
With its unsurpassed noise Airborne Structure sound transmits from the
insulating characteristics, sound borne sound shock or impact zone over the
PhonEX®AS is the optimal Sound which diffuses in the Sound which diffuses in solid whole pipe.햵 Due to
solution where noise air.햲 Occurs inside the pipe materials.햴 Structure borne vibration of the pipe
insulation is required. The due to impact and flow noises. sound is created by the additional airborne sounds are
patented raw material Sound energy is absorbed in impact of wastewater on the generated. The special
Astolan® has a high specific the pipe wall.햳 PhonEX®AS pipe wall, especially in vertical molecular structure of
weight and special molecular pipe material provides stacks in the area of bends PhonEX®AS enables the
structure, which enables excellent airborne sound and branches. Structure borne absorbtion of structure borne
absorption of airborne sound absorbing behaviour, because sound.
as well as structure borne of its high specific weight and 햲 햳 Airborne Sound

sound. special molecular structure. PhonEX®AS

Astolan® absorbs sound

햴 햵 Structure Borne Sound


Cast Iron PhonEX®AS

Astolan® absorbs sound

07

Noise Insulating Properties


The Weight Weight per meter: PhonEX®AS has been proven Test results have confirmed
per meter of DN 56 = 1,40 kg/m in extensive comparative that PhonEX®AS gives an
PhonEX®AS DN 70 = 2,10 kg/m measurements at the Institute excellent performance
The weight per meter of a soil DN 90 = 2,30 kg/m for Sound and Heat compared to Cast Iron.
and waste system is of great DN 100 = 3,55 kg/m Protection, Prof. Dr. Zeller,
importance in absorbing DN 125 = 4,40 kg/m Essen, Germany.
airborne and structure borne DN 150 = 5,15 kg/m
sounds. The combination of DN 200 = 7,50 kg/m The sonic behaviour of PhonEX®
AS
Wavin AS
high specific weight and low compared to Cast Iron
elasticity gives the optimal Installation: outside the measuring room
results in damping the The Sonic
transmission of both sounds Behaviour of Cast Iron
through a pipe system. PhonEX®AS 40 dB (A)*
Cast Iron
PhonEX®AS is specifically PhonEX®AS is the modern 34 dB (A)*
developed to make optimal alternative to cast iron. In
Astolan®®
Astolan
use of both properties and contrast to metallic materials, Wavin ®AS
PhonEX AS Astolan®®
Astolan
resulted in relative thick walls Astolan® displays a low level 28 dB
28 dB (A)*
(A)* Wavin ®AS
PhonEX AS
and high specific material of noise transmission. Sound 25dB
25 dB (A)*
(A)*
weight. Therefore pipe energy cannot spread over
weights should not be less the pipe wall. The extreme
than indicated in the following sound insulating behaviour of
table:
Pipe bracket without insert Pipe bracket with insert

Institute for Sound and Heat Protection, Prof. Dr. Zeller, Germany.
Test report of 30-09-1986/15.216. * Installation wall 80 kg/m2
Noise Insulating Properties The sonic
The sonic behaviour
behaviourofofPhonEX
Wavin®AS
AS
Installation: outside the measuring room
In case of correct installation PhonEX ®
Wavin ASAS
of the PhonEX®AS system (see
page 20-21, recommendations) 12,8
extremely low levels of noise PhonEX ®
Wavin ASAS dB (A)*
emission are achieved.
This has been confirmed by 8,5
noise measurements at the dB (A)*
PhonEX ®
Wavin ASAS
Frauenhofer Institute for
Building Physics, Stuttgart,
Noise measurement at 3,9
Germany. Frauenhofer Institute for Building dB (A)*
Physics, Stuttgart, P-BA 130/1997
* Installation wall 220 kg/m2 0.5 L/S water 1.0 L/S water 2.0 L/S water

08

Technical Data
Material:
Astolan®; polypropylene, mineral reinforced, resistant to hot
water, DIN 4102, B2.

Physical characteristics:
Density ~ 1,9 g/cm3 3 DIN 53479
Elongation at break ~ 29%
Tensile strength ~ 13 N/mm2
E-modulus ~ 3800 N/mm2
Coefficient of thermal
linear expansion ~ 0,09 mm/mK
Fire resistancy ~ DIN 4102, B2
Colour: Light grey RAL 7035

Marking:
PhonEX®AS, nominal diameter, production year, quality mark,
approval, material, control mark, fire classification.

Example:
PhonEX®AS, DN 100, 2002,
Z.-42.1-228, ASTOLAN®, Ü DIN 4102, B2.
Product list
AS - plain ended pipe
Dim. Article d s L Weight Standard
DN No. mm mm mm kg/m Packing
56 91.1.0000 58 4,0 3000 1,40 30
70 91.1.0002 78 4,5 3000 2,30 38
90 91.1.0003 90 4,5 2000 2,30 35
100 91.1.0004 110 5,3 3000 3,55 29
125 91.1.0006 135 5,3 3000 4,40 23
150 91.1.0008 160 5,3 3000 5,15 20
200 91.1.0010 200 6,2 3000 7,50 14

AS - socketed short length


Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
56 91.1.0100 150 0,30 672
70 91.1.0102 150 0,70 360
90 91.1.0103 150 0,50 240
100 91.1.0104 150 1,05 196
125 91.1.0106 150 1,40 140
150 91.1.0108 150 1,50 100

Socket dimension
Dim. d d1 s t
DN mm mm mm mm
56 58 75 4,0 54
70 78 96 4,5 56
90 90 110 4,5 55
100 110 132 5,3 61
125 135 161 5,3 64
150 160 181 5,3 66
200 200 227 6,2 85
All fittings with sockets are pre-assembled with sealing rings.
For spare sealing rings see page 15. 09

AS - compensator socket
Dim. Article d1 d2 t t1 t2 L Weight Standard
DN No. mm mm mm mm mm mm kg/pc. Packing
56 91.1.2000 75 72 49 5 15 126 0,20 924
70 91.1.2002 96 84 48 6 16 119 0,30 576
90 91.1.2003 110 104 47 6 16 123 0,30 400
100 91.1.2004 132 116 48 6 16 124 0,49 308
125 91.1.2006 161 141 63 6 16 132 0,66 192
150 91.1.2008 181 166 63 6 16 144 0,75 120
All compensator sockets are pre-assembled with collars and sealing rings.
For spare collars and sealing rings see page 15.

AS - double socketed sleeve,


with central register
Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
200 91.1.2022 168 1,33 75
Connecting element between pipes as well as between pipes and fittings.
Product list
AS - double socketed sleeve
Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
56 91.1.2010 105 0,18 1000
70 91.1.2012 107 0,26 640
100 91.1.2014 117 0,43 336
125 91.1.2016 124 0,56 216
150 91.1.2018 143 0,62 140
200 91.1.2020 168 1,30 140
Only for subsequent installation or repair purposes.

AS - long socket
Dim. Article d1 t te L Weight Standard
DN No. mm mm mm mm kg/pc. Packing
100 91.1.2400 110 127 74 210 0,80 196

For constructing a branch or prefabrication at a later date.

10

AS - long bend 45°


Dim. Article d1 t te Z1 Z2 Weight Standard
DN No. mm mm mm mm mm kg/pc. Packing
100 91.1.2390 110 57 250 24 28 1,30 112

For a simple adjustment of long leg bend ( or long leg elbow 450) in
narrow installation with 450 change of direction, or stepped 900 change
of direction.
Product list
AS - bends
Dim. O
Article z1 z2 Weight Standard 15°, 30°, 45°, 67° and 87°
DN No. mm mm kg/pc. Packing
56 15° 91.1.2200 19 8 0,22 960
56 30° 91.1.2220 24 16 0,21 800
56 45° 91.1.2240 28 17 0,22 800
56 67° 91.1.2260 43 21 0,23 660
56 87° 91.1.2270 47 32 0,25 768
70 15° 91.1.2202 26 10 0,33 500
70 30° 91.1.2222 30 17 0,37 480
70 45° 91.1.2242 37 21 0,39 480
70 67° 91.1.2262 48 31 0,42 400
70 87° 91.1.2272 62 42 0,46 340
90 15° 91.1.2203 8 8 0,33 380
90 30° 91.1.2223 15 14 0,35 340
90 45° 91.1.2243 22 20 0,36 320
90 87° 91.1.2273 49 42 0,41 256
100 15° 91.1.2204 27 15 0,61 220
100 30° 91.1.2224 37 19 0,65 224
100 45° 91.1.2244 44 28 0,71 196
100 67° 91.1.2264 60 44 0,74 168
100 87° 91.1.2274 78 58 0,89 144
125 15° 91.1.2206 29 16 0,81 160
125 30° 91.1.2226 38 45 0,91 120
125 45° 91.1.2246 50 34 0,98 120
125 87° 91.1.2276 96 102 1,37 80
150 15° 91.1.2208 13 19 0,89 100
150 30° 91.1.2228 24 30 1,00 100
150 45° 91.1.2248 36 42 1,10 64
150 87° 91.1.2278 83 89 1,77 48
200 45° 91.1.2250 47 42 1,99 40
200 87° 91.1.2280 103 93 2,51 32

AS - air circulation bend 135°


11
Dim. Article Z1 Z2 Z3 Z4 a Weight Standard
DN No. mm mm mm mm mm kg/pc. Packing
100 91.1.2290 78 58 44 28 19,5 1,24 110

For secondary venting systems

Secondary venting system


with PhonEX®AS
air circulation bend

Smaller
possible
distance
165 mm.
Product list
AS - trap conversion bend
Dim. Article d1 d2 Z1 Z2 Weight Standard
DN No. mm mm mm mm kg/pc. Packing
40/56 91.1.2380 50 58 30,5 25 0,08 800

Seals DN 40/30 B and DN 40/40 C are part of the PhonEX® PP delivery


programme.

AS - branches 45°, 67°, 87°


Dim. ° Article Z1 Z2 Z3 Weight Standard
DN No. mm mm mm kg/pc. Packing
56/56 45° 91.1.2030 28 74 74 0,43 424
56/56 67° 91.1.2060 36 45 45 0,38 400
56/56 87° 91.1.2080 48 32 32 0,37 336
70/56 45° 91.1.2032 17 83 79 0,58 280
70/56 67° 91.1.2062 31 54 46 0,51 280
70/56 87° 91.1.2082 48 42 28 0,49 320
70/70 45° 91.1.2034 38 99 99 0,75 216
70/70 67° 91.1.2064 47 61 60 0,64 252
70/70 87° 91.1.2084 62 43 43 0,59 240
90/56 45° 91.1.2037 -3 97 84 0,70 224
90/90 45° 91.1.2035 19 113 106 0,70 168
100/56 45° 91.1.2036 1 110 97 0,94 140
100/56 67° 91.1.2066 24 75 52 0,82 140
100/56 87° 91.1.2086 47 61 27 0,78 160
100/70 45° 91.1.2038 21 122 115 1,22 112
100/70 67° 91.1.2068 40 81 67 1,00 120
100/70 87° 91.1.2088 60 61 43 0,94 140
100/100 45° 91.1.2040 44 136 136 1,50 88
12
100/100 67° 91.1.2070 58 84 84 1,20 96
100/100 87° 91.1.2090 78 58 58 1,10 112
125/100 45° 91.1.2042 31 155 152 1,79 62
125/100 87° 91.1.2092 78 73 59 1,39 72
125/125 45° 91.1.2044 49 169 169 2,04 56
125/125 87° 91.1.2094 90 72 72 1,56 60
150/100 45° 91.1.2046 2 168 159 1,80 46
150/150 45° 91.1.2048 36 194 194 2,20 24
200/200 45° 91.1.2050 42 247 239 4,40 16

AS - double branche 87°


Dim. Article Z1 Z2 Z3 Weight Standard
DN No. mm mm mm kg/pc. Packing
100/100/100 91.1.2100 78 58 58 1,40 72
Product list
AS - corner branche 87°
Dim. Article Z1 Z2 Z3 Weight Standard
DN No. mm mm mm kg/pc. Packing
100/100/100 91.1.2110 78 58 58 1,58 80

AS - parallel branche
Dim. Article Z1 Z2 Z3 Z4 Z5
DN No. mm mm mm mm mm
100/100 91.1.2120 44 136 136 44 28

a b L Weight Standard
mm mm mm kg/pc. Packing
129 19,5 320 1,93 70

13

Smallest connection Smallest connection


height 260 mm height 195 mm

AS - socket plug
Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
56 91.1.2340 49 0,11 1000
70 91.1.2342 52 0,20 1000
90 91.1.2343 40 0,18 800
100 91.1.2344 57 0,37 500
125 91.1.2346 60 0,51 200
150 91.1.2348 49 0,54 300
Product list
AS - reducer
Dim. Article z1 L Weight Standard
DN No. mm mm kg/pc. Packing
56/ 40 91.1.2300 -18 60 0,03 1000
70/ 56* 91.1.2302 -28 76 0,05 1000
70/ 56 91.1.2304 -28 76 0,20 1012
90/ 56 91.1.2303 -32 84 0,30 864
90/ 70 91.1.2305 -29 82 0,40 800
100/ 56 91.1.2306 -10 87 0,45 360
100/ 70 91.1.2308 -10 87 0,47 336
100/ 90 91.1.2309 -35 87 0,47 540
125/100 91.1.2310 -13 90 0,63 240
150/100** 91.1.2312 -44 115 0,98 112
150/125** 91.1.2314 -33 125 1,00 120
200/150** 91.1.2316 32 142 1,32 60

*Internal diameter of socket: 50 mm (PP)


** long version

AS - access pipe type RU


Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
56 91.1.2320 151 0,30 480
70 91.1.2322 208 0,87 196

With round access lid.

AS - access pipe type RE


Dim. Article L Weight Standard
DN No. mm kg/pc. Packing
14
100 91.1.2330 298 1,12 72
125 91.1.2332 316 1,46 60
150 91.1.2334 345 3,52 40

With rectangular access lid.

Safety clip for socket plug


Dim. Article Standard
DN No. Packing
56 91.1.2491 1
70 91.1.2493 1
100 91.1.2496 1
125 91.1.2497 1
150 91.1.2498 1
200 91.1.2499 1

Axially fixed.
Product list
Fire protection collar
Dim. Article h D di Standard type NE/Compact
DN No. mm mm mm Packing
56-70 91.1.2530 20 108 88 2
90-100 91.1.2532 30 150 120 2
125-150 91.1.2534 40 210 170 2
200 on request - - - -

Easy installation below the ceiling or on the wall by a folding system.


Approval nr.: Z-19.17-1390

Coating for wall duct


Dim. Article Standard
DN No. Packing
50 91.1.2540 10
70 91.1.2542 10
100 91.1.2544 10
125 91.1.2546 10
150 91.1.2548 10
200 91.1.2550 -
ARMAFLEX.

Spare collar and sealing ring


Dim. Collar Standard Sealing rings Standard
DN Art.-No. Packing Art.-No. Packing
40 - - 91.1.2440 20
56 (50 mm) 91.1.2461 10 91.1.2441 20
56 (58 mm) 91.1.2462 10 91.1.2442 20
70 (75 mm) 91.1.2463 10 91.1.2443 20
70 (78 mm) 91.1.2464 10 91.1.2444 20
90 91.1.2465 10 91.1.2445 20
100 91.1.2466 10 91.1.2446 20
125 91.1.2467 10 91.1.2447 20 15
150 91.1.2468 10 91.1.2448 20
200 - - 91.1.2450 20

Lubricant
Contents per Article Standard
bottle No. Packing
500 ml 91.1.2480 648

Dimension Consumption
DN of lubricant per/500ml
56 approx. 40 connections
70 approx. 35 connections
90 approx. 32 connections
100 approx. 30 connections
125 approx. 25 connections
150 approx. 20 connections
200 approx. 10 connections

It is recommended to use the KE KELIT Lubricant.


When using a local lubricant, always use a clear lubricant.
Product list
Bracket with rubber insert
Fixed bracket

Dim. Article Note: This bracket can be used both as a


DN No. fixed bracket and as a sliding bracket.
56 11.5.1800
70 11.5.1802 The only difference is the small plastic rings.
90 11.5.1804 When the bracket is used as a fixed bracket;
Bracket with rubber insert 100 11.5.1806 the plastic rings should be removed. When
Sliding bracket 125 11.5.1808 using the bracket as a sliding bracket; the
150 11.5.1810 plastic rings should be put in place
200 11.5.1812 (see picture sliding bracket).

Transition Fittings to other Soil & Waste Systems


Connection to PP, PVC-U
and PE spigot end Dim. Article te L Weight Standard
DN No. mm mm kg/pc. Packing
56* 91.1.2360 - 50 0,04 2000
70 91.1.2361 77 130 0,07 720
* Short version

PhonEX®AS Other Plastic Systems


16
DN OD
56 X 50
70 X 75

Connection to PP, PVC-U


and PE spigot end
Dim. Article t L Weight Standard
DN No. mm mm kg/pc. Packing
125 91.1.2370 82 245 1,34 120

PhonEX®AS Other Plastic Systems


DN OD
125 X 110

Connection from other Plastic Systems to PhonEX®AS

Other PhonEX®AS PhonEX®AS


Plastic System Transition Fitting
Product list
Connection from Cast Iron to PhonEX®AS Compression Coupler
PhonEX®AS Dim. Article Standard
DN No. Packing
PhonEX®AS
56 91.1.2420 1320
70 91.1.2421 960
100 91.1.2422 540
125 91.1.2423 360
150 91.1.2424 240
200 91.1.2425 -

Can also be used for subsequent


installation of pipes and fittings.

Connection from PhonEX®AS to PVC-U


Description Article Dim.
PhonEX PVC-U
PhonEX AS
®
PhonEX PVC-U No. DN
PhonEX PVC-U 91.1.2620 125
Transition Fitting

Direct connection from PhonEX®AS to other Plastic Systems

PhonEX®AS Other Plastic


Systems
DN OD
90 X 90
100 X 110
150 X 160
200 X 200
17
Flexible transition fittings with Konfix from PhonEX®AS to PP, PE-HD and Cast Iron Connection with Konfix

Dim. Article
DN No.
56 91.1.2600
70 91.1.2602
90 91.1.2604
100 91.1.2606
125 91.1.2608
Installation
Fields - Hotels - Collector pipes
of application - Hospitals - Stack pipes
This product and installation - Shopping Malls - Ventilation pipes
guide is valid for soil and - Office Buildings - Rain stack pipes
waste installations in buildings - Residential homes - Underground pipes up to
and dwellings which are - Apartments inspection chamber / manhole
constructed in PhonEX®AS - Schools and Universities
pipes and fittings – raw
material: Astolan®. PhonEX®AS pipes and fittings
can be installed in the
Multiple storey buildings following fields of application:
requiring noise insulation: - Single waste or drain pipes

18

Waste
2 1 and ventilation pipes
4
3
Examples
1. Rain stack pipe
2. Main ventilation
3. Single drain / waste pipe
5
4. Vents for collector pump
cellars
6
5. Collector pipe
6. Stack pipe for waste water
7. Connecting sewer pipe
(PVC-U)
8. Soil pipe
acces pipe acces pipe inspection chambers 9. Collector pipe
10. Rising sewer pipe (PVC-U)
11. Underground collector
9
10 pipeline
8 7
12. Faecal collection
(cellar) pit

11

12
Handling & Storage
Packing standardized 3 metre length PhonEX®AS fittings are packed
PhonEX®AS pipes and fittings of all pipes there is only one in practical carton box pallets.
are packed ready for transport pallet type for each dimension
in a customer friendly way. (DN 56, DN 70, DN 100,
The packing guarantees DN 125, DN 150 and DN 200).
optimal security, efficient This saves space in the
storage and easy handling. warehouse. Further, KE KELIT
offers DN 90 (wall mounting)
Standard delivery unit for in 2 metre length.
pipes is per pallet. It contains The pallets can be handled
14 to 38 pipes depending on with a forklift truck.
the pipe diameter. Due to the

19

Storage
If stored correctly no lasting The stack of loose pipes
deformations or damage to should never be higher than
pipes and fittings will occur. 1,5 metre.
Factory bundled pipe pallets The elastomeric sealing rings
can be stacked. should peferably not be
stored in the open air.

Transport length during transport.


PhonEX®AS pipes – when no Bending of the pipes should
1,50 m

longer packed in original be avoided. Impact stress on


pallets – must lie fully pipes and fittings must be
supported over their total prevented.
Recommendations
Sound clear German Standards and at least 220 kg/m2. It is recommended to wrap a
insulation Regulations (eg DIN 4109 and layer of mineral wool around
National / Local building DIN 1053). The same requirement also the pipe, where contact with
regulations should be applies when installed in a the plaster layer cannot be
observed where applicable. Waste pipes should not be shaft and fixed on the avoided.햶
In order to achieve optimal used in living, sleeping and intermediate wall. Shafts can
sound insulation it is highly working rooms. Should the be closed with a minimum 1,5 햶
recommended to implement waste pipe system be fixed on cm plaster layer on an
the following instructions. massive walls adjacent to appropriate support. The
These instructions are based living, sleeping and working PhonEX®AS pipe system must
on years of experience in rooms, the specific area be free from the plaster layer,
compliance with strict and weight of that wall should be avoiding sound bridges.

Mineral wool

20

햷 Emitted sounds depend highly a short piece of straight pipe


on the course of the pipe. with a minimum length of
The prevention or reduction 25 cm.햷 For this purpose the
of impact zones leads to less 45° long bend is included in
sound emission. It is the PhonEX®AS program
therefore recommended to (see page 10).
prevent abrupt directional
changes. Instead of installing For optimal sound insulation,
a 90° elbow it is far better to use full encircling brackets
change the direction from with inserts of corrugated
vertical to horizontal with two rubber.햸
45° elbows, interconnected by


cm
25

WAVIN
PhonEXAS-Socket
®
AS-Socketcompensator
compensator
Recommendations
Installation As long as stability and bearing eg central heating pipes as well
in walls capacity are not impaired, it is as hot tap water pipes.
In case PhonEX®AS is to be allowed to cut shafts and
installed against a wall with channels in brick work walls. Pipe and shaft dimensions to be
separate decorative top layer External heating of PhonEX®AS taken from the table below and
(e.g. plaster boards), it is pipes should be limited by heat figure 8.
required that the brackets are insulating the source;
fixed to the construction wall
and not to the decorative layer. Table: Space requirement for PhonEX®AS pipes DN 56 upto DN 100 mm
Passing holes in the decorative DN OD of pipe OD of Min. required
layer can be mended by using
da socket dm spacing*, terf
elastic filler.
(mm) (mm) (mm) (mm)
56 58 79 125
70 78 96 142
90 90 110 156
100 110 132 179
* The stated depths are not including pipe crossings

21

Installation Roof 햺
in concrete drainage pipes
PhonEX®AS pipes and fittings Roof drainage pipes projected
can be casted in concrete. through living, sleeping and
Thermal induced lateral working rooms can be
movements to be dealt with, installed as pictured in figure 9.
according to previous The specific area weight of the
instructions. Pipes and fittings casting should be at least
must be secured properly in equal to the wall and Casing 11,5 cm brick + plaster
order to prevent lateral preferably for both at least
movement during casting of 220 kg/m2. Although the
the concrete. Close the formation of condensation on
annular gap between pipe and the outside of PhonEX®AS
socket with sealing tape to pipes is less than on metallic
prevent ingres of mortar in pipes, it is recommended to
the sealing ring. insulate the pipes and fittings. Wall weight > 220 kg/m2
Recommendations
Floor
crossings
Floor crossings should be
made leak resistant and sound
absorbent. In the case of the
floor being concreted,
PhonEX®AS pipes and fittings
should be protected by using
a protection sleeve or heat
insulating wrapping material.

22

Pipe the ends of the PhonEX®AS


cutting pipes must be chamfered.
PhonEX®AS can be cut simply (Note: Does not apply for
with a commercial pipe cutter PVC-U fittings with
or saw. Always cut the pipe elastomeric sealing ring as
straight. Remove all swarf and well as PP pipes and fittings).
burrs from the cut end and
clean the pipe end. Bevel
sharp cutting edge – do not
chamfer! (figure 10)

For connections to socketed


pipe systems with roll-rings,
Jointing
Joints with the expansion length. This is not
compensator socket required for PhonEX®AS, as
The PhonEX®AS compensator the compensator socket
socket is used to connect two adapts to temperature
pipes as well as a pipe and changes in the system. This
fitting where compensation not only saves working time,
for axial movements is but also gives additional
required. For conventional technical security to the
plastic soil and waste pipe system.
systems the expansion margin
is created by marking and
withdrawing the pipe to the

쐃 쐇

쐋 쐏

23

Mounting - Apply KE KELIT lubricant*


instructions sparsely inside compensator
When making the connection socket of fitting (2).
with the compensator socket - Apply and distribute
쐄 쐂 the following instruction rules KE KELIT lubricant* evenly
should be adhered to: on outside of elastomeric
- Clean pipe end. compensator collar (3).
- Check the position and - Push fitting over compensator
condition of the elastomeric collar to full insertion depth.
sealing ring in the groove. Check final position of
Further check the condition compensator collar** (4-6).
of the elastomeric - Apply KE KELIT lubricant on
expansion collar. the next pipe end or spigot
햽 If necessary, clean fitting, fitting and insert in the
DN L t t1 t2
sealing ring and collar. socket end to full depth.
(mm) (mm) (mm) (mm) (mm)
- Push the expansion collar
56 126 49 5 15
over the pipe end (1). *) Never use oil or grease
70 119 48 6 16 ATTENTION: The expansion **)Insertion depth for pipe with
90 123 47 6 16 collar may only be pushed collar into the compensator
100 124 48 6 16 over the plain pipe ends, socket, see figure 11
125 132 63 6 16 never over the spigot end of
150 144 63 6 16 fittings.
Jointing
Joints without In case no use is made of the Socket connections between 햾
the compensator compensator socket, the fittings only, need no
socket required lateral expansion consideration for lateral
Push-fit joints between pipes tolerance can be created by compensation due to
of maximum 3 metre lengths inserting the pipe end to full temperature differences and
and fittings must be capable of depth and subsequently can therefore be fully inserted.
absorbing lateral thermal withdrawing the pipe end by
expansion of up to 10 mm. 10 mm. (figure 12).

24

Installation In case of vertical installation 2. Cut required pass length


PhonEX®AS socket of pipes, the individual pipe 3. Deburr and bevel cutting
connection lengths must be fixed edges.
The socket connection is to immediately after assembly 4. Slide branch or access pipe
be installed as follows: with pipe brackets, in order to on upper pipe end
- Check the position and avoid the pipe from sliding 5. Fit one double socketed 헀
condition of the elastomeric downwards and eliminating sleeve, over its full length,
sealing ring in the groove. the 10 mm expansion / on pass length
If necessary, clean fitting contraction allowance. 햿 6. Fit one double socketed
and sealing ring. sleeve, over its full length,
- Clean pipe end or spigot Making a on lower pipe end
fitting. connection on an 7. Fit in pass length and close Double socketed
sleeve
- Apply KE KELIT lubricant* in already installed the pipe by sliding the
a thin and equal layer on pipe double socketed sleeves in
Min. 2,5 x OD

pipe end. This can easily be executed position Fixed bracket


Pass
- Insert pipe end straight to using standard PhonEX®AS 8. Fix double socketed sleeves length

the central register of the fittings. as pictured in figure 14. Double socketed
sleeve
socket.
- Withdraw pipe by 10 mm. Installation instructions using Alternatively KE KELIT
– never the fitting – double socketed sleeves: compression couplers or
Fixed bracket
1. Cut out a sufficient length PhonEX®AS long socket (only
*) Never use oil or grease of pipe (length of fitting DN 100) can also be used.
plus 2,5x OD of pipe)
Fixing Technique
General inserts of corrugated rubber, prevent the joints from sliding 헁
instructions which are fixed to the wall by apart. 헂 Alternatively the
In principle PhonEX®AS soil screws and plastic plugs*. 헁 fixing brackets can be
and waste systems should be arranged appropriately.
installed tension free and with For pipe systems in which
free lateral allowance for inner-pressures can arise, *) Metal plugs can be used, but
temperature compensation. the joints have to be secured will lead to disadvantageous
Use sound absorbing to avoid them from sliding sound emission.
brackets, dimensionally apart and deviating from the
compatible to the pipe centre axis.
diameter. Recommended are 헂
screw-pipe brackets with The KE KELIT safety clips

25

Fixing way: brackets – in the vertical as


Fixed bracket well as in the horizontal
The fixed bracket creates a installation – must be sliding
fixed point in the pipe brackets. The prescribed
system. With fixed brackets bracket distances should not
the pipe or fitting cannot be be exceeded.
moved through the bracket
after the screws are tightened Fixing way:
(no longitudinal movement is Sliding bracket
possible). In order to prevent By using sliding brackets the
sliding down of the vertical pipe can still be moved
stack, each individual pipe through the bracket after the
length must be secured on screws are tightened
one point by a fixed bracket. (longitudinal movement is
Fittings or groups of fittings possible once installed).
must always be shaped as
fixed points.

Also every horizontally


installed pipe should always
be fixed with one fixed
bracket. All remaining pipe
Fixing Technique 

Arrangement 1-2 metre (1).


of the brackets - Generally pipe brackets Wavin
PhonEXAS
®
AS
During installation of PhonEX® should not be installed in Compensator socket
AS pipes, the following should impact areas. (eg diameter
be considered: reductions and changes of
- In case of horizontal directions in the system).
installation, the pipe - Pipe brackets to be fixed to Sliding bracket

1–2m
bracket distances 10X the building materials with high
outside diameter of the specific area weight.
pipe. In case of vertical - For stack pipes in open Fixed bracket
pipe installation, depending mounting shafts and high
on outside diameter, rooms (storey height over PhonEX
Wavin ®
ASAS
Compensator socket

26

 2,5 metres) it is advised to or short pipes are to be


PhonEX AS Compensator socket
® use one fixed bracket and secured in such short
one sliding bracket per pipe distances with pipe
Sliding bracket
length. brackets, that they cannot
- The fixed bracket must be slide apart.
installed directly above the
fitting at the bottom of the In exceptional cases, where
PhonEX®AS short pipe end. The sliding connecting elements other
socketed length bracket must be installed at than the compensator socket
as stack pipe
support a distance of maximum of are used (eg double socketed
Fixed bracket 2 metres above the fixed sleeve), per maximum
bracket . allowable pipe length
- In multiple storey buildings (3 metres), one fixed bracket
(from 3 storeys and more) and one sliding bracket
the stack pipes of DN 100 should be installed in line
or bigger must be secured with the illustrations  and 
by additional fixing shown on this page of this
(stack pipe support) against manual. The double socketed
sliding . In this case we sleeves to be fixed.
advise using the PhonEX®AS
PhonEX®AS
Compensator socket socketed short length with a
fixed bracket.
Stack segments with fittings
Fire Protection Collar
Fire mechanical pipe seal. Thus to DIN 4102-part 11) - Only three articles cover the
Protection preventing fire transmission - For installation at a later range from DN 56 to DN
In exceptional cases where and providing a smoke tight date on walls and ceilings 150 mm
fire protecting measures are lock for at least 90 minutes. - Optimally attuned to - Easy, Quick and Safe
necessary, the PhonEX®AS Fire PhonEX®AS, as part of the installation
Protection Collar (Type Type NE / low noise soil & waste
NE/compact) is the integral Compact system
solution in the PhonEX®AS - For fire isolation, of minimal - Approved by the German
System. 90 minutes, in PhonEX®AS Institute for Building
systems crossing walls and (Approval nr.: Z-19.17-1390)
The fireproof blowing material floors (fire protection - Small and compact – only
inside the collar creates a classification F90, according 3cm high for DN 100 mm

Fire protection
Installation of PhonEX®AS fire protection collar at ceiling
crossing

27

Assembly fire 5. Mark the three holes for


protection collar: fixing on the ceiling or wall
1. Lead PhonEX®AS pipe and drill the holes with a
through ceiling or wall and drilling machine.
insulate against structure 6. Fix the collar with three
borne sound (material screws, and the assembly is
thickness ≤ 15 mm completed.
Fire protection Armaflex or non-
Installation of PhonEX®AS fire protection collar at combustible mineral wool) Note:
wall crossing 2. Fill the annular gap between This is only a short description
insulation and ceiling or of the assembly instruction.
wall with concrete. Please take notice of the
3. Open fire protection collar extensive instruction which
NE Compact (loosen screw will be enclosed in the
on the side) and bend the packing of the fire protection
three fixing straps by 900. collar.
4. Bend up fire protection
collar and put it around the
PhonEX®AS pipe, close it
and secure it with the screw
on the side.
Quality Assurance system certified
by ÖQS
ÖNORM EN ISO 9001: 2000
Reg.Nr.366/0

Member of
Austrian Working group for
PLASTIC PIPE RECYCLING

KE KELIT
Kunststoffwerk GesmbH.
A-4017 Linz, Ignaz-Mayer-Straße 17
Austria – Europe Innovative Pipesystems
Tel. +43/73 2/77 92 06-0
Fax +43/73 2/77 92 06-118
e-mail: office@kekelit.com
www.kekelit.com

You might also like