Professional Documents
Culture Documents
CITEC - Gen-X Catalogue 2008 Final
CITEC - Gen-X Catalogue 2008 Final
superior performance
01 Gen-X
The Citec GEN-X series of precision air conditioning system is the real
solution for critical space. It is designed for 24/7 and round the clock
operation. Quick reactions to drastic change in heat load always become
its main duty in order to prevent huge temperature fluctuation.
GEN-X
03 Gen-X
3
4
1) Electrical Panel
2) Coil
3) Air Filter
4) Scroll Compressor
7) Heater
05 Gen-X
Features
Plug fan blowers (upflow system – Air Filter Control and monitoring system
backward curve) Protect against airborne contaminants Prevent and reduce costly downtime
More efficient and less noise. within the critical environment which can duration with mature monitoring systems
damage storage media and charged that provide complete supervision all the
Optional EC fan electronics components. time on temperature and humidity.
Energy saving and efficient.
Touch screen display
Heaters Comes with a user friendly menu for ease
2-stage stainless steel heaters of finned of navigation. Displays graphical
design for extended life. Low watt density, information and status of trend and plotted
sheathed elements are made of stainless graphs for both temperature and humidity
steel with integral high efficiency fins, in 3 different languages namely English,
reducing sheath temperatures and Chinese and Thai.
eliminating ionization. It also keeps the
temperature from going too low during
dehumidification cycle.
06 Gen-X
• Capacity ranges from 60kW to 135kW Heaters Microprocessor control with in house
2-stage stainless steel heaters of finned program
• Available in both upflow and downflow design for extended life. Low watt density, Built in auto-sequencing feature enables
configurations sheathed elements are made of stainless interfacing with most of the commonly
steel with integral high efficiency fins, used serial communication standards.
• Cooling, humidification, dehumidification, reducing sheath temperatures and With an optional interface card, it can be
reheating, filtration eliminating ionization. It also keeps the integrated into the most widespread BMS
temperature from going too low during systems.
• Factory pre-piped, wired and tested dehumidification cycle.
Optional EC fan
Energy saving and efficient.
Air Filter
Protect against airborne contaminants
within the critical environment which can
damage storage media and charged
electronics components.
Elegant Range (Air Cooled, Water Cooled and Dual Coil Systems)
The GEN-X Elegant Range of Air Cooled, Water Cooled and Dual Coil air
conditioning systems are designed according to the stringent
requirement of data centers. It provides high sensible cooling to data
center in energy efficient way.
The Elegant Range is easily customizable for larger capacity and capable
for high external static pressure application. The dual coil options
provide redundancy and flexibility with dual cooling source thus enable
even higher energy efficiency.
• Capacity ranges from 50kW to 90kW Belt driven fan blowers (downflow Air Filter
system - forward or backward curve) Protect against airborne contaminants
• Available in both upflow and downflow
Adjustable for varying static requirement. within the critical environment which can
configuration
damage storage media and charged
• Cooling, humidification, dehumidification, Plug fan blowers (upflow system – electronics components.
reheating, filtration backward curve)
More efficient and less noise. Touch screen display
• Factory pre-piped, wired and tested
Comes with a user friendly menu for ease
• Precisely control temperature and of navigation. Displays graphical
humidity to ±1ºC and ±5%RH information and status of trend and plotted
graphs for both temperature and humidity
Features in 3 different languages namely English,
Chinese and Thai.
Scroll compressor (twin circuit)
Efficient and reliable performance with a Microprocessor control with in house
robust design which concern on quiet program
operation and continual smooth compression Built in auto-sequencing feature enables
process. The discharge gas and vibration are interfacing with most of the commonly
kept at a low level. It has internal vibration EC fan as option used serial communication standards.
isolation mountings, pressure safety controls Energy saving and efficient. With an optional interface card, it can be
and built-in overload protection gives integrated into the most widespread BMS
excellent durability. Heaters systems.
2-stage stainless steel heaters of finned
Coil design for extended life. Low watt density, Control and monitoring system
Large face area/low face velocity design for sheathed elements are made of stainless Prevent and reduce costly downtime
precise control of cooling and steel with integral high efficiency fins, duration with mature monitoring systems
dehumidification. reducing sheath temperatures and which provide complete supervision all the
eliminating ionization. It also keeps the time on temperature and humidity.
Electronic expansion valve temperature from going too low during
Provide fast and precise response to changes dehumidification cycle.
in room condition which gives more stable
unit operation and save energy at low load Electrical panel
condition. The real time superheat monitoring High Low voltage segregation and each
enable early detection on refrigerant leakage, components are protected by individual
at the same time ensures proper refrigerant MCB. High voltage compartment contains
charge. the contactors, miniature circuit breaker,
transformer and other components and
protected by a separate over-current
protective device.
08 Gen-X
Commander Range
Technical Specifications
Airflow m³/s 4.2 5.0 5.0 5.8 6.7 6.7 7.4 8.4
m³/hr 15120 18000 18000 20880 24120 24120 26640 30240
Electric Reheat
No. of Steps - 2 2 2 2 3 3 3 4
Capacity kW 12 18 18 18 27 27 27 36
Humidifier
Connections
Chilled Water In mm 42 42 54 54 63 63 63 63
Chilled Water Out mm 42 42 54 54 63 63 63 63
Humidifier Feed mm 15 15 15 15 15 15 15 15
Drain mm 22 22 22 22 22 22 22 22
Dimensions
Unit Depth mm 885 885 885 885 885 885 885 885
Width mm 1550 1800 1800 2050 2300 2300 2550 2800
Height mm 1954 1954 1954 1954 1954 1954 1954 1954
Weight kgs 455 535 570 785 850 890 935 980
Note: All the cooling performances are based on Air On: 24˚C, 45%RH
Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
10 Gen-X
Deluxe Range
Technical Specifications
Electric Reheat
No. of Steps - 2 2 2 3 3 4
Capacity kW 12 18 18 27 27 36
Humidifier
Connections
Chilled Water In mm 42 54 54 54 63 63
Chilled Water Out mm 42 54 54 54 63 63
Humidifier Feed mm 15 15 15 15 15 15
Drain mm 22 22 22 22 22 22
Dimension
Note: All the cooling performances are based on Air On: 24˚C, 45%RH
Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
11 Gen-X
Elegant Range
Technical Specifications
Models EXD / U _ _ A / W / DA / DW 50 65 70 80 90
Airflow m³/s 3.5 4.2 5.0 5.8 6.7
m³/hr 12600 15120 18000 20880 24120
“A” Version
Total kW 49.55 56.85 70.02 74.54 87.23
Sensible kW 44.10 51.43 62.57 68.53 79.44
S.H.R. - 0.89 0.90 0.89 0.92 0.91
Connections
Air Cooled CACR 326 326 506 506 506
Condensers Model
Liquid Line inch 5/8” 5/8” 3/4” 3/4” 7/8”
Discharge Line inch 1 1/8” 1 1/8” 1 1/8” 1 1/8” 1 3/8’
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22
Compressors Model ZR108 ZR125 ZR144 ZR160 ZR190
“W” Version
Total kW 52.25 61.39 71.33 78.96 95.32
Sensible kW 45.62 54.02 63.29 71.36 84.74
S.H.R - 0.87 0.88 0.89 0.90 0.89
Connections
Water Cooled B10/60 B10/60 B10/80 B10/80 B80/60
Condensers Model
Condenser Water - mm 42 42 54 54 54
In / Out
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22
Chilled Water Coil Performance of “DA” and “DW” Version
Total kW 50.30 59.96 70.98 83.50 93.78
Sensible kW 45.20 53.96 64.00 75.02 84.70
S.H.R - 0.90 0.90 0.90 0.90 0.90
Water Flow Rate I/s 2.40 2.86 3.40 3.98 4.48
Connections
Chilled Water In mm 42 42 54 54 54
Chilled Water Out mm 42 42 54 54 54
Electric Reheat
No. of Steps - 2 2 2 2 3
Capacity kW 12 18 18 18 27
Humidifier
Humidifier Capacity kg/hr 8 15 15 15 15
Capacity Power kW 6.00 11.25 11.25 11.25 11.25
Dimension
Unit Depth mm 885 885 885 885 885
Width mm 1800 2050 2300 2550 2800
Height mm 1954 1954 1954 1954 1954
Weight kgs 620 725 810 910 985
Note: All the cooling performances are based on Air On: 24˚C, 45%RH
Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
12 Gen-X
Performer Range
Technical Specifications
“A” Version
Connections
“W” Version
Connections
Water Cooled B10/60 B10/80 B10/80 B80/60 B80/75
Condensers Model
Condenser Water - mm 42 54 54 54 63
In / Out
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22
Electric Heat
No. of Steps - 2 2 2 2 3
Capacity kW 12 18 18 18 27
Humidifier
Dimension
Note: All the cooling performances are based on Air On: 24˚C, 45%RH
Due to our policy of continuous development and improvement, the specifi cations and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
13 Gen-X
Notes
www.citec.com.my