Output Ratings
Generating Set Model Prime* 500.0 kVA 400.0 kW * Refer to ratings definitions on page 4. Ratings at power 0.8 Ratings at .8 power factor. factor Standby* 550.0 kVA 440.0 kW -
380-415V,50Hz
Technical Data
Engine Make & Model: Alternator Model: Base Frame Type: Circuit Breaker Type: Frequency: Engine Speed: RPM Fuel Tank Capacity: litres (US gal) Fuel Consumption, Prime: l/hr (US gal/hr) Fuel Consumption, Standby : l/hr (US gal/hr) 97.2 (25.7) 106.8 (28.2) Perkins 2506A-E15TAG2 LL6114F Heavy Duty Fabricated Steel 3 Pole MCCB 50 Hz 1500 928 (245.2) 60 Hz -
Lubrication system
Oil Filter Type: Total Oil Capacity l (US gal): Oil Pan l (US gal): Oil Type: Cooling Method: Eco, Full Flow 62.0 (16.4) 53.0 (14.0) API CI4 15W-40 Water
Performance
Engine Speed: RPM Gross Engine Power: kW (hp) -Standby: -Prime:
50 Hz
1500 487.0 (653.0) 443.0 (594.0)
60 Hz
-
Fuel System
Fuel Filter Type: Replaceable Element Recommended Fuel: 110% Load
Air System
Air Filter Type: Combustion Air Flow: m/min (cfm) -Standby: -Prime: Max. Combustion Air Intake Restriction: kPa (in H2O) Radiator Cooling Air Flow: m/min (cfm) External Restriction to Cooling Air Flow: Pa (in H2O)
50 Hz
Paper Element 18" 32.0 (1130) 30.5 (1077) 6.2 (24.9) 660.0 (23308) 125 (0.5)
60 Hz
Class A2 Diesel Fuel Consumption: l/hr (US gal/hr) 100% Load 75% Load 50% Load
Prime 50 Hz 60 Hz Standby 50 Hz 60 Hz 106.8 (28.2) 80.7 (21.3) 55.0 (14.5) 106.8 (28.2) 97.2 (25.7) 73.6 (19.4) 50.4 (13.3) -
(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
Cooling System
Cooling System Capacity: l (US gal) Water Pump Type: Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby: -Prime: Heat Radiation to Room: kW (Btu/min) -Standby: -Prime: Radiator Fan Load: kW (hp)
50 Hz
38.3 (10.1)
60 Hz
-
Exhaust System
Silencer Type: Silencer Noise Reduction Pressure Drop Across Silencer System: kPa (in Hg) Silencer Noise Reduction
50 Hz
Level 1
60 Hz
SD150 (1) 0.34 (0.100) 15 6.8 (2.0) 87.0 (3072) 81.0 (2860) 528 (982) 514 (957) -
Centrifugal
166.0 (9440) 157.0 (8928) 49.0 (2787) 47.0 (2673) 16.0 (21.5)
Level: dB Max. Allowable Back Pressure: kPa (in. Hg) Exhaust Gas Flow: m/min (cfm) -Standby: -Prime: Exhaust Gas Temperature: C (F) m/min (cfm) -Standby: -Prime:
Cooling system designed to operate in ambient conditions up to 50C (122F). Contact your local Olympian dealer for power ratings at specific site conditions.
60 Hz
1296
1213
1106
1438
300
300
300
300
300
300
300
300
300
Xd X'd X''d
Reactances shown are applicable to standby ratings. * Based on 30% voltage dip. ** With optional Permanent Magnet generator or AREP excitation.
Operating Data
Overspeed: RPM Voltage Regulation (steady state) (% ): Wave Form NEMA = TIF: Wave Form IEC = THF: Total Harmonic Content LL/LN: Radio Interference: 2250 +/- 0.5 50 2.0% 2.0%
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, RPM
Voltage
kVA
415/240V 400/230V 380/220V 230/115V 220/127V 220/110V 200/115V 500.0 500.0 500.0 500.0 460.0 500.0 500.0
Prime
kW
400.0 400.0 400.0 400.0 368.0 400.0 400.0
Standby
kVA
550.0 550.0 550.0 550.0 506.0 550.0 550.0
Voltage
kW
440.0 440.0 440.0 440.0 404.8 440.0 440.0
Prime
kVA kW
Standby
kVA kW
Dimensions: mm (in)
Length Width Height 3700 (145.7) 1100 (43.3) 2143 (84.4)
Note: General configuration not to be used for installation. See general dimension drawings for detail.
Definitions
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
General Data
Documents
A full set of operation and maintenance manuals and circuit wiring diagrams.
Warranty
All equipment carries full manufacturer's warranty.