1Brief Introduction of MP760 ................................................ 3 2Functions and Specifications ................................................ 7 3External Dimension and Installation................................... 11 4Edit Software ...................................................................... 12
2.General Specifications
Input Voltage Power Consumption Momentary Allowance Power Off AC220V Lower than 10W (TYP2.0W) Less than 20ms AC1000V-10mA 0~50 10~60 20~85%No Dew 10~25Hz (X, Y, Z each direction 30 min.2G) Voltage Noise: 1000Vp-p No corrosive gasses Fit with IP65F 1min. (between signal and ground)
Voltage Endurance Insulated resistor Operating Temperature Storage Temperature Ambient Temperature Vibration Endurance Anti-interference Surrounding Atmosphere Protection Structure
Function Keys
Digital keyboard
Label
Communication Port
Download port
Output terminals
Input terminals
Write the modified data into the register, then go on modifying the next register, after the last one been modified, exit the modifying state. Alarm list key, after setting the alarm list functions, press this key to enter alarm list screen quickly.
When modifying the data of the register, clean the selected area.
When modifying the data of the register, set the value to be negative or positive Number keys (0-9), in the state of setting data, the modifying bit turns to be the correspond keys value
Attention: Besides the functions described in the above table, each key can also be defined to be set ON, set OFF, Reverse, or Momentary ON by the user.
6. Download/communication port
(1) Download Port: Both the HMI and XC2 use the same RS232 download port. Pin2 Pin3 Pin4 Pin5 RXD TXD RTS GND
RS-485 Communication Port: be used to connect HMI with the slave equipments Pin1 Pin9 Pin6 Pin8 A B PRT (short connect pin5 and pin6 to enable print function) DOWNLOAD (short connect pin5 and pin8 to force downloading)
2Communication Port: The communication port for XC2 series PLC, RS-232 or RS-485
Port
2. PLC Specifications
(1) Input specifications and wiring
Input Signals Voltage Input Signals Current Input ON Current Input OFF Current Input Response Time Input Signal Form Circuit Insulation Input Action Display V DC24V10% 7mA/DC24V Up to 4.5mA Below 1.5mA About 10ms Contact input or NPN normally ON transistor. Optical- coupling insulation LED be on when input is on
Internal Power Supply Circuit Isolation Action Indication Resistor load Maximum Induction load Load Lamp load Open Circuit Leakage Circuit Minimum Load Response OFFON Time ONOFF
Transistor Output
Below AC250VDC30V Mechanism isolation LED indicator 3A 80VA 100W No DC5V 2mA 10ms 10ms Below DC5~30V
Optional-coupling insulation LED indicator 0.8A 12w/DC24V 1.5W/DC24V < 0.1 mA DC5V 2mA 0.2ms 0.2ms
Internal Power Supply Circuit Isolation Action Indication Maximum Resistor load Load Induction load Lamp load Open Circuit Leakage Circuit Minimum Load OFFON Response ONOFF Time
3Output wiring
Relay output wiring
8
3.Functions Configuration
(1) Input/output format
I/O: 16 inputs 16 outputs Input: optical-Coupling isolation Output: R type (relay output), T type (transistor output)
Input X0 X1 X3 X6 X7
AB phase high-speed counter: 2 channels Channel CHL1 CHL2 Input X0X1 X3X4 Maximum frequency 80KHZ 5KHZ
(3) High-speed pulse RT/T type: Y0Y1, Maximum 200KHZ R typeDo not support (4) External interrupts External interrupt: 2 channels CHL1 CHL2 X2 X5 INT 0 INT 1
10
1. External dimension
2. Mounting dimension