Professional Documents
Culture Documents
Table PD957, BP220
Table PD957, BP220
MAXIMUM SELLING
PRICE (House & lot
package
PROJECT LOCATION
PD 957
OPEN MARKET HOUSING
BP 200
ECONOMIC HOUSING
Above P150,000 P375,000
BP 220
SOCIALIZED HOUSING
P150,000 & below
Same as PD957
Same as PD957
a. 70% (maximum)
b. 30% (minimum)
a. variable
b. see open space
requirement as per b1, b2
& b3
a. variable
b. see open space
requirement as per b1, b2
& b3
LAND ALOCATION
(Percentage of Gross Area
One Hectare & Above)
a. Saleable area
b. Non-saleable area
Density
(no of Lots/
dwelling unit
per hectare)
% of Gross
% of Project Gross Area
area
allocated for
Parks &
Playgrounds
20 & below
150 & below
3.5%
same as economic housing
21- 25
151-160
4.0%
26- 35
161-175
5.0%
36- 50
176-200
6.0%
51- 65
2001-225
7.0%
above 65
above 225
9.0%
AN ADDITION OF 1% INCREMENT FOR EVERY 10 OR
FRACTION THEREOF ABOVE 225
Note: in no case shall the area be less than 100 square meters
Mandatory allocation for community facilities per tabulation below
b.2 Area Allocated for
Community Facilities
% of Gross
area
allocated for
Parks &
Playgrounds
3.5%
4.0%
5.0%
6.0%
7.0%
9.0%
Variable
Density
(dwelling unit
per hectare)
Density
No. of lots and/or Living
Units per Hectare
150 & below
1.0%
151.225
1.5%
above 225
2.0%
Single Detached
Single Attached/ Duplex/
Semi Detached
Rowhouse
100 sqm.
75 sqm.
72 sqm.
54 sqm/ unit
72 sqm.
54 sqm/ unit
50 sqm
(house & lot)
35 sqm
35 sqm
PARAMETER
MINIMUM LOT
FRONTAGE
SINGLE DETACHED
a. corner lot
b. regular lot
c. irregular lot
DUPLEX/ SINGLE
ATTACHED/ SEMI
DETACHED
ROW HOUSE
LENGTH OF BLOCK
PD 957
OPEN MARKET HOUSING
12 m
10 m
6m
BP 200
ECONOMIC HOUSING
10 m
8m
6m
7.5 m
BP 220
SOCIALIZED HOUSING
10 m
8m
6m
6m
3.5 m
Maximum length is 400m
(for subdivision projects
with lot component only)
3.5 m
Same as PD 957
Same as PD 957
ROADS RIGHT-OF-WAY
a. Major
b. Minor
Note: for row houses there shall be a maximum of 20 units but in no case shall be more
than 100 meters in length
ROW
CARRIAGE ROW
CARRIAGE ROW
CARRIAGE
12.0 m
10.0 m
8.0 m
6.0 m
10.0 m
8.0 m
6.5 m
6.0 m
6.0 m
6.0 m
5.0 m
-
10.0 m
8.0 m
6.5 m
6.0 m
6.0 m
6.0 m
5.0 m
-
c. Motorcourt (Cul de
6.0 m
Sac, branch, loop,
Tee)
d. Alley
4.0 m
3.0 m
3.0 m
e. Footpath
3.0 m
3.0 m
f. ROW access to interior
3.0 m
3.0 m
3.0 m
lot
- Right-of-way (ROW) of major roads shall be increased as project size increases. ROW shall not be lower than Row of
public road.
- Major roads shall maintain a uniform width of road right-of-way. Tapering of road width shall not be allowed
Note: 1. Interior subdivision projects must secure right-of-way to the nearest public road.
2. Subdivision projects with direct access to a main public road must provide sufficient setback to accommodate
loading and unloading passenger.
3. Subdivision project shall provide provision for further expansion.
MAXIMUM SIZES OF
PROJECT PER
HIERARCHY ROADS
Project Size Range
25 hectares & below
above 2.5-5 hectares
above 5- 10 hectares
above 10-15 hectares
above 15-30 hectares
above 30 hectares
PARAMETER
ROAD SPECIFICATIONS
1.Planting Strip (PS)
Sidewalk (SW)
PD 957
OPEN MARKET HOUSING
PS
SW
BP 200
ECONOMIC HOUSING
PS
SW
BP 220
SOCIALIZED HOUSING
PS
SW
concrete/ asphalt
concrete/ asphalt
concrete/ asphalt
concrete/ asphalt
concrete/ asphalt
developed
areas
under dev
areas
conc/asphalt
conc/asphalt
asphalt
asphalt
aggregates
macadam
macadam
macadam
aggregates
aggregates
WATER SUPPLY
Mandatory connection to
appropriate public water
system or community
system if available, or
Centralized water system
If public
Level II 1
water supply communal
system
faucet or
exists,
communal
mandatory
well per 25
connection
dwelling
(level III)
units
Note: each subdivision must have at least an operational deep well and pump sets with
sufficient capacity to provide ADD provided a spare pump and motor set is reserved
Minimum water supply
requirements
Fire Protection
Provision for fire protection shall comply with the requirements of the National Fire
Protection Code
Underground
Underground for major
Lined open canal (sides of
roads, lined open canal for
open canal shall be lined
other roads
with stone rip-rap
DRAINAGE SYSTEM
150 LCPD
for
household
connection
43 LCPD
Handpump
The drainage system must conform with the natural drainage pattern of the subdivision
site and shall drain into appropriate water bodies, public drainage system or natural
outfalls
PARAMETER
PD 957
OPEN MARKET HOUSING
BP 200
ECONOMIC HOUSING
BP 220
SOCIALIZED HOUSING
SEWAGE DISPOSAL
SYSTEM
Septic Tank
Connection to
community sewer
system
POWER SUPPLY
GARBAGE DISPOSAL
SYSTEM
SHELTER COMPONENT
Minimum floor area
a. single-detached
Front
Side
Rear
Abutments
Mandatory individual
household connection if
service is available in the
locality
22 sqm
b. Duplex
c. Rowhouse
Minimum level of
completion
a. single-detached
b. Duplex
c. Rowhouse
STBACKS / EASEMENTS
Individual or communal
septic tank conforming to
standard design of the
Sanitation Code
18 sqm
22 sqm
18 sqm
22 sqm
18 sqm
Note: Minimum floor area shall be in one floor level
exclusive of mezzanine if any.
Complete house
Complete house
Complete house
Complete house
Complete house
Complete house
Shell house
Shell house
Shell house
3
1.5
1.5
2
2.0
2.0
2
2.0
2.0
Maybe allowed per requirements of National Building Code