East Campus
Critical Environment Management
Award-winning Operations Team
State of the art control and monitoring
Physical security audits and assessments
Mission critical responsiveness
Pursuing SSAE 16 certifcation
Overview
Modular effciency for mid-sized data center users. At $.056/kWh, SDC offers the lowest electrical
rate of any major metropolitan area
Infrastructure Power plus connectivity
26 KV from redundant distribution
switchgear
Designed at 150 Watts / SF
Tier 3 Design up to 4,500 kW of IT load
Tier 1 Design up to 800 kW of IT load
Design PUE of 1.18
Concurrently maintainable
(in Tier 3 Modules)
Redundant UPS and Caterpillar 2.5 MW
generators N+1 (in Tier 3 Modules)
STS with separate UPS modules feeding
A & B power to cabinets (in Tier 3 Modules)
12 fber carriers to serve site through
redundant access
Emergency backup 72 hours on-site fuel
with emergency fuel contract
Dual fuel delivery/return system with
monitoring
Effcient free-cooling system is backed-up
by N + 1 chillers
Security
24/7/365 monitoring & control
Mantraps with dual authentication access
Ballistic-rated building access points
Dual interlocked pre-action sprinklers
Incipient smoke detection (VESDA)
Design Effciency
On-deck mounting for racks, cabinets &
SAN devices
Overhead cable tray & power distribution
Modular for easy, cost-effective expansion
Hot Aisle Encapsulation
OFFICE
4202
4201
TURNKEY 1
4203
TURNKEY
2
1,500 kW
per
module
Filter Intake louvers Exhaust fans
Outside Air Exhaust
Evaporative
cooling
90 Return air
from hot aisle
70 Supply air
to cold aisle
Supply fans
ot
old
Roof
The Cooling System -
Effcient, Reliable and Inexpensive
Seattles mild climate helps deliver ample
cooling capacity at a fraction of the cost
elsewhere. Cool, relatively dry ambient air
fows from outside into a direct evaporative
system with airside economizers to deliver
optimally conditioned air to the server foor.
Virtually the only electricity consumed is
through the Fan Wall which makes air
handling more effcient. Variable speed
motors adjust airfow as heating requirements
change. A closed loop system supplies the
chillers with water as needed, minimizing loss
through evaporation.
Modular chillers allow staged expansion
to accommodate customers growth
requirements.
No data center space is wasted on bulky
CRAC units.
Superior air fow management through hot/
cold aisle design
Seattle City Light, the nations only carbon-neutral electrical utility, recognized
SDCs saving of up to 6 million kWs of energy annually with the awarding of its
largest ever Power Players award and utility incentive.
Heat passes into a hot
aisle containment
Our turnkey modular free-cooling system directs more electricity to the real work of
the data center processing data rather than cooling.
Free-Cooling 90% of the Year
Airside economizers use
a series of dampers and
fans to mix air to the
ideal state
Cool air is supplied
around the server racks,
evenly cooling the
servers inside.
Outside air passes
through dual sets of
flters and then a wet
evaporative medium
within the indoor air-
stream producing cool,
humid air
1
2
3
Hot return air is
ducted outdoors
or reused.
5
4
About Sabey Data Center Properties
For more than 25 years, Sabey Data Centers (SDC) has been building
relationships while developing some of the worlds fnest multi-tenant
data centers. With a portfolio of three million square feet of mission
critical space and another million under development, SDC is one of the
top privately owned-multi-tenant data center developers and operators
in the world.
SDC specializes in scalable, highly effcient, custom-built solutions
including data center-ready powered shell, turnkey and build to suit
data centers. Our turnkey spaces are operated by an award-winning
critical environment management team consistently recognized
for its disciplined performance and sustained data center uptime.
Some of the worlds most uncompromising enterprises rely on
SDC were proud of our long relationships with our customers,
our most important asset.
509 99
99
509
509
E
M
a
r
g
in
a
l W
a
y
518
518





T
u
k
w
ila

I
n
t
e
r
n
a
t
i
o
n
a
l

B
l
v
d
M
i
l
i
t
a
r
y

R
d

S
8
t
h

A
v
e

S
8
t
h

A
v
e

S
4
2
n
d

A
v
e

S
B
e
a
c
o
n
A
v
e

S
S 136th St
Starfire Sports
Complex
S
W
G
rady Way
S
W
Sunset Blv
d
Foster Golf
Course
M
i
l
i
t
a
r
y

R
d

S
W

V
a
l
l
e
y

R
d
O
a
k
s
d
a
l
e

A
v
e

S
W
SW 7th
R
e
n
to
n
A
v
e
S
Westfield
Southcenter
SeaTac
Seattle-Tacoma
International
Airport
S 154th St
Sunset
Park
Hilltop
Park
Boeing Field
King County
International
Airport
South
Beacon Hill
W

M
a
r
g
in
a
l
W
a
y
E

M
a
r
g
i
n
a
l

W
a
y
Rainier
Beach
S Othello St
Bryn
Mawr-Skyway
M
a
r
t
in

L
u
t
h
e
r

K
in
g

J
r

W
a
y

S
R
a
in
ie
r
A
v
e
S
S 128th St
D
e
s

M
o
i
n
e
s

M
e
m
o
r
i
a
l

D
r
M
a
r
t
i
n

L
u
t
h
e
r

K
i
n
g

J
r

W
a
y

S
SDC42
6 minutes to SeaTac
Airport, 12 minutes to
Downtown Seattle
Intergate.Seattle is Sabey Data Centers fagship data center. Its 1.2 m square feet comprise
both East and West campuses. SDCs Seattle turnkey locations are highlighted in blue.
1
0
.
1
3
12201 Tukwila International Blvd. 4
th
Floor
Seattle, WA 98168 | Main 206.281.8700
sabeydatacenters.com
For more information contact:
info@sabeydatacenters.com

You might also like