903-2.

Cylinder Lubricators
Checking

3.

Check of Accumulators: 4. Measuring the nitrogen pre-pressure can only be done with stopped engine and pressure-free lubrication system. Stop both oil pumps. Close the inlet valve and open the equalizing valve on the respective lubricator. The nitrogen pressure in the inlet accumulator (0.7 litre) can be checked without dismounting the accumulator. For use of the pressure setting tool, see Step 5. 5. To measure the nitrogen pressure in the outlet accumulator (0.16 litre), the accumulator or the lubricator with accumulator must be dismounted. See Procedure 903-2.2. For nitrogen pressure in the accumulators, see Data. 6. Use of Pressure Setting Tool Assemble the pressure setting tool as shown in Figure 5, and mount the reducing valve on the nitrogen cylinder. If necessary, use a threaded adaptor.

D-2
EN903-2.1 219 04

D-1

5.

NA903-2.1 222 05

Mount a 0-60 bar pressure gauge on the filling valve when the inlet accumulator (0.7 litre) is to be checked, and a 0-10 bar pressure gauge when the outlet accumulator (0.16 litre) is to be checked.

Page 2 (10)

When referring to this page, please quote Procedure M90302 Edition 0226 0$1 % : 'LHVHO $6

Cylinder Lubricators
Checking
6. A C

903-2.1

7. Before mounting the filling valve on the accumulator, check that the accumulator top is clean. Mount the filling valve on the relevant accumulator with the union nut. Check that valves C and F are closed. Loosen the plug screw in the accumulator using a square drive handle in socket E. It is now possible to read the actual nitrogen pressure in the accumulator on the dial gauge on the filling valve. 8. If the accumulator needs to be refilled with nitrogen, open valve A and increase the outlet pressure from valve C on spindle B to 1-2 bar above the pressure stated in Data. Open valve C until the accumulator is filled to the correct pressure. Close valve C and tighten the plug screw with socket E to the torque stated in Data. Release the pressure in the filling valve at bleed screw F. Unscrew the filling valve from the accumulator. Retighten the plug screw to the torque stated in Data. Remount the accumulator.

D-3 F

When referring to this page, please quote Procedure M90302 Edition 0226 0$1 % : 'LHVHO $6

NA903-2.1 222 06

Page 3 (10)

Cylinder Lubricators
Data SAFETY PRECAUTIONS
Special Data S50MC-C 0015 103-2 Cylinder Lubricators

103-2

Standard Tools: See Section 913

X X X X

Stopped engine Block the starting mechanism Shut off starting air supply Engage turning gear Shut off cooling water Shut off fuel oil Shut off lubrication oil Lock turbocharger rotors

Data
Ref. Description Value Unit

D-1

Nitrogen pressure inlet accumulator Nitrogen pressure outlet accumulator Plug screw tightening torque

25-30 bar

D-2

1.5 bar

D-3

30 Nm

When referring to this page, please quote Data D10302 Edition 0015 MAN B&W Diesel A/S

Page 1 (2)

103-2

Cylinder Lubricators
Data

Spare Parts
Plate Item No. Description Qty

90307-xxx 102 90307-xxx 234 90307-xxx 246 90307-xxx 557 90307-xxx 437 90307-xxx 582

O-ring O-ring Feedback sensor (pick-up), complete O-ring O-ring O-ring

2 1 1 1 12 1

Page 2 (2)

When referring to this page, please quote Data D10302 Edition 0015 MAN B&W Diesel A/S