Purlin Check

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

BlueScope Buildings Malaysia a division of NS BlueScope Lysaght Malaysia Sdn. Bhd.

Project : Tittle : MRT MAIN FACTORY LOUVERS Purlin Checking-LOUVERS Reference : Date : Designer : YODOFORM catalogue 26-Nov-13 FATIMA

Reference
Purlin Capacity Check DL = LL = WL =
2 0.05 kN/m 2 0.00 kN/m 2 0.65 kN/m

Calculation

Output

4 Ix = 4517000.00 mm

Purlin spacing = Maximum span = Load IN

1.5 10.0

m m

(1.4 DL +1.6 LL) x Purlin spacing Load OUT (DL + 1.4WL) x Purlin spacing Purlin size choose = YZP2020

0.105

kN/m

1.44

kN/m

(simply supported)

IN max = OUT max =

1.05 0.75

kN/m kN/m

0.105 1.44

kN/m kN/m

OK! OK!

OK!

Deflection Check W= Unfactored (dead + imposed load ) x Purlin spacing x Bay spacing= Maximum deflection = 5WL 384EI =
3

0.75 kN mm

10.55

Allowable deflection = span/150

66.666667 mm

OK!

Thus, use purlin size =

YZP2020

Use : YZP2020

Bolt and Weld capacities

You might also like